Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
Más filtros










Intervalo de año de publicación
1.
Clin Ophthalmol ; 18: 1095-1102, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38707769

RESUMEN

Purpose: To assess the surgical efficiency in cataract surgery comparing two phacoemulsification systems. Methods: Prospective, consecutive-comparative study in a two-site private practice. Three hundred and one eyes undergoing standard or femtosecond laser-assisted (FLACS) cataract surgery with either the R-Evo Smart (BVI, Waltham, USA) and/or the Centurion Vision System (Alcon, Fort Worth, USA). Preoperative eye characteristics (degree of cataract using the lens opacities classification system LOCS III grading) and intraoperative outcomes (total ultrasound time and total estimated fluid aspirated/drainage bag weighting) were registered in all cases. Results: One hundred and fifty-five eyes undergone cataract surgery with the R-Evo Smart and 146 eyes with the Centurion Vision System phacoemulsification systems. Mean cataract grade was 3.07 ± 0.78 and 2.96 ± 0.85 for the R-Evo Smart and Centurion Vision System groups, respectively (p = 0.12). Mean total ultrasound time was 18.99 ± 12.85 and 40.24 ± 21.91 seconds for the R-Evo Smart and Centurion Vision System groups, respectively (p < 0.01). Mean total estimated fluid aspirated/drainage bag weighting was 53.00 ± 14.56 g and 54.33 ± 14.88 cc for the R-Evo Smart and Centurion Vision System groups, respectively (p = 0.21). Considering non-FLACS surgery (98 eyes with the R-Evo Smart and 63 eyes with the Centurion Vision System), mean cataract grade was 2.95 ± 0.74 and 2.97 ± 0.91 for the R-Evo Smart and Centurion Vision System groups, respectively (p = 0.44). Mean total ultrasound time was 19.96 ± 11.20 and 42.84 ± 28.35 seconds for the R-Evo Smart and Centurion Vision System groups, respectively (p < 0.01). Mean total estimated fluid aspirated/drainage bag weighting was 55.95 ± 14.76 g and 55.97 ± 13.62 cc for the R-Evo Smart and Centurion Vision System groups, respectively (p = 0.49). No adverse events were found in the two groups of eyes. Conclusion: The objective measurement of surgical efficiency through total ultrasound time during lens removal and fluid consumption during both lens removal and irrigation/aspiration proved R-Evo Smart to be an efficient phacoemulsification platform, in comparison with the current standard of care Centurion Vision System.

2.
Eye Vis (Lond) ; 11(1): 14, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38556883

RESUMEN

BACKGROUND: To assess clinical outcomes after implanting toric, extended-depth-of-focus intraocular lenses (IOLs) to correct low corneal astigmatism in eyes with cataracts. METHODS: 47 eyes were implanted with the AcrySof IQ Vivity Toric DFT215 IOL. Main outcome measures were refractive error, monocular uncorrected and corrected distance (UDVA/CDVA), uncorrected and distance-corrected intermediate (UIVA/DCIVA), and uncorrected near and distance-corrected near (UNVA/DCNVA) visual acuities, monocular defocus curve, rotational stability, and IOLSAT and QUVID questionnaires. Patients were assessed at 3 months postsurgery. RESULTS: All eyes had a postoperative spherical equivalent (SE) within ± 0.50 D and 97.87% (n = 46) had a refractive cylinder ≤ 0.50 D. The mean SE and refractive cylinder were - 0.10 ± 0.17 D and - 0.16 ± 0.24 D, respectively. The CDVA was ≥ 20/25 and ≥ 20/32 in 95.74% (n = 45) and 97.87% (n = 46) of eyes, respectively. The DCIVA was ≥ 20/32 in 85.11% (n = 40) of eyes and the DCNVA was ≥ 20/40 in 74.47% (n = 35). The mean values of CDVA, DCIVA, and DCNVA were - 0.02 ± 0.08, 0.14 ± 0.09, and 0.23 ± 0.12 logMAR, respectively. The defocus curve revealed good visual acuity at far and intermediate distances with a depth-of-focus of about 1.75 D. IOL rotation was 0.74 ± 1.13 degrees and all eyes had a rotation of less than 5 degrees. Patients reported either good or very good postoperative vision without eyeglasses under bright-light-conditions at distance (87.80%, 36/41) and intermediate distance (92.68%, 38/41). Between about 63.83%-72.34% (30-34) of patients reported no starburst, halos, or glare, or if experienced, were not bothersome. CONCLUSIONS: The Vivity toric IOL implanted in eyes with low-astigmatism provides accurate refractive outcomes, good visual acuity at different distances and excellent rotational stability. Trial Registration The study was registered with the German Clinical Trials Register (DRKS00030579).

3.
Clin Ophthalmol ; 18: 27-40, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38192579

RESUMEN

Purpose: To assess refractive and visual outcomes post-cataract surgery with bilateral implantation of a bi-aspheric diffractive trifocal intraocular lens (IOL). Methods: A total of 24 patients who underwent bilateral implantation with the Asqelio Trifocal IOL TFLIO130C were evaluated at the 6 months postoperative mark. Key outcome measures included refractive error, photopic monocular and binocular uncorrected and corrected distance visual acuity (UDVA, CDVA), uncorrected and corrected intermediate visual acuity (UIVA, CDIVA) at 60 cm, and uncorrected and corrected near visual acuity (UNVA, CDNVA) at 40 cm. Additionally, monocular and binocular CDNVA were assessed under mesopic conditions. Monocular and binocular defocus curves, and binocular contrast sensitivity under photopic and mesopic conditions, with and without glare, were measured. Catquest-9SF and visual symptoms questionnaires were also administered. Results: Postoperative average values of binocular logMAR photopic CDVA, photopic CDIVA, photopic CDNVA and mesopic CDNVA were -0.01±0.06, 0.03±0.09, 0.02±0.05 and 0.19±0.13, respectively. About 100% of patients showed cumulative CDVA and CDNVA ≥20/25, and CDIVA ≥20/32. The average absolute depth-of-focus was about 4.50D. The average postoperative spherical equivalent was 0.05±0.30D and 100% and 93.75% eyes were within ±1.00D and ±0.50D, respectively. Contrast sensitivity was either within or above normal levels under both photopic and mesopic conditions, both with and without glare, except for 12 cpd under mesopic conditions with glare where the mean falls just below the normal range. Questionnaires revealed that 87.5% of patients were either satisfied or very satisfied with their vision after the surgery, and higher percentages for no difficulty in performing different activities, ranging from 70.83% to 95.83%, were reported. Conclusion: This study demonstrates that the bi-aspheric diffractive trifocal IOL yields very good visual performance across distances, fostering high satisfaction levels and minimal difficulties in daily activities.

4.
Clin Ophthalmol ; 17: 3397-3407, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37954911

RESUMEN

Purpose: To evaluate the refractive and visual outcomes following cataract surgery and implantation of a diffractive trifocal intraocular lens (IOL) with a 7.0 mm optical zone. Methods: A total of 23 patients who underwent bilateral implantation with the Triva-aXAY IOL were analyzed at 6 months post-surgery. The main outcome measures were refractive error, monocular and binocular uncorrected and corrected-distance visual acuity (UDVA, CDVA), uncorrected and corrected-distance intermediate visual acuity (UIVA, CDIVA) at 60 cm, uncorrected and corrected-distance near visual acuity (UNVA, CDNVA) at 40 cm, and binocular defocus curve. Patients also completed the Catquest-9SF questionnaire. Results: All eyes were within ±1.00D, and 91.30% of eyes within ±0.50D, with a mean postoperative spherical equivalent of -0.14±0.29D. Similarly, 95.65% of patients showed a binocular UDVA ≥20/25, compared to 100% for CDVA, and the mean binocular UDVA and CDVA were 0.02±0.06 and 0.00±0.05 logMAR, respectively. At intermediate vision, 65.22% of patients showed a binocular UIVA ≥20/25, compared to 86.96% for CDIVA, and the mean binocular UIVA and CDIVA were 0.07±0.06 and 0.06±0.06 logMAR, respectively. At near, 95.65% of patients showed a binocular UNVA and CDNVA ≥20/25, with a mean binocular UDNVA and CDNVA of 0.04±0.07 and 0.02±0.05 logMAR, respectively. Finally, 95.65% of patients reported being quite satisfied to very satisfied with their vision and about 74% did not report any difficulty with their vision in their everyday life. Between 65.22% and 100% of patients reported no difficulty performing different tasks. Conclusion: Our study shows good visual and refractive outcomes with high satisfaction in patients implanted with the Triva-aXAY IOL with a 7.0 mm optical zone.

5.
Clin Ophthalmol ; 17: 2765-2776, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37750099

RESUMEN

Purpose: To show the visual and refractive outcomes in cataract patients with corneal astigmatism when bilaterally implanted with a biconvex aspheric toric monofocal intraocular lens (IOL) with a double C-loop haptic-design. Methods: Forty-seven cataract patients (94 eyes) with corneal astigmatism (≥0.75D) were implanted with the monofocal PODEYE toric IOL and assessed for 4-6 months post-surgery. Measurements included monocular and binocular uncorrected-distance visual acuity (UDVA) and corrected-distance visual acuity (CDVA), under both photopic and mesopic lighting conditions. Refraction, photopic and mesopic contrast sensitivity (with and without glare), and rotational stability were also recorded at the last postoperative visit. Results: At 4-6 months, 78.2% and 98.9% of eyes were within ±0.50D and ±1.00D of the target refraction, respectively. The mean spherical equivalent and refractive cylinder values were 0.09±0.35D and -0.36±0.35D, respectively. 76.5% and 98.8% of eyes presented a postoperative refractive cylinder of ≤0.50D and ≤1.00D, respectively. 91.5% and 100% of patients had a binocular UDVA and CDVA of ≥20/25, respectively. The mean binocular UDVA and CDVA were 0.02±0.08 and -0.02±0.07 logMAR, respectively. Under mesopic conditions, 78.7% and 83.0% of patients presented a binocular UDVA and CDVA ≥20/32, respectively. The mean binocular UDVA and CDVA were 0.15±0.11 and 0.12±0.11 logMAR, respectively. The patients showed good contrast sensitivity under photopic and mesopic conditions. The mean absolute IOL rotation was 1.22±2.21 degrees with 97.87% of eyes having a rotation of <10 degrees. Conclusion: This study shows good visual and refractive outcomes for the PODEYE toric IOL when implanted bilaterally in cataract patients with corneal astigmatism.

6.
Eye Vis (Lond) ; 10(1): 35, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37653460

RESUMEN

BACKGROUND: To evaluate the axial length acquisition success rates and agreement between various biometric parameters obtained with different biometers in dense cataracts. METHODS: Fifty-one eyes were measured using Anterion®, Argos® and IOLMaster® 700 swept-source optical coherence tomography (SS-OCT) biometers, a Pentacam® AXL partial coherence interferometry (PCI) biometer, and an OcuScan® RxP ultrasound biometer. We measured keratometry (K1, flattest keratometry and K2, steepest keratometry), white-to-white (WTW), anterior chamber depth (ACD), lens thickness (LT) and axial length. Cataracts were classified according to the Lens Opacities Classification System III grading system, the dysfunctional lens index (DLI) and Pentacam® nucleus staging (PNS) metrics. Percentage of acquisition success rate and a Bland-Altman analysis for the agreement between biometers were calculated. RESULTS: The mean LOCS III score was 3.63 ± 0.92, the mean DLI was 2.95 ± 1.30 and the mean PNS was 2.36 ± 1.20. The acquisition success rates for the Anterion®, Argos®, IOLMaster® 700, Pentacam® AXL and OcuScan® RxP biometers were 94.12%, 100%, 98.04%, 60.78% and 100%, respectively. There were significant differences in the success rates between biometers (P = 0.014). There were statistically significant differences between biometers for all parameters evaluated (P < 0.05). The range of the limit of agreement (LoA) for all comparisons of K1 and K2 were > 1.00 D. The LoA for WTW ranged from 0.095 to 1.050 mm. The LoA for ACD and LT ranged from 0.307 to 0.114 mm and from 0.378 to 0.108 mm, respectively. The LoA for axial length ranged from 0.129 to 2.378 mm. CONCLUSIONS: Among optical biometers, those based on SS-OCT technology are more successful at measuring axial length in eyes with dense cataracts. TRIAL REGISTRATION: The study was registered with the National Institutes of Health (clinical trial identifier NCT05239715, http://www. CLINICALTRIALS: gov ).

7.
Clin Ophthalmol ; 17: 1245-1253, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37152638

RESUMEN

Purpose: To assess the agreement in automated corneal diameter (CD) and anterior chamber depth (ACD, measured from corneal epithelium to lens) distances measurements between the IOLMaster 500 and 700 optical biometers in myopic eyes. Methods: One hundred and sixteen eyes of 116 myopic patients aged between 21 to 60 years were included in this study. Measurements of CD and ACD distances were taken with each biometer for all patients in the same session. A t-test and a p-value less than 0.05 was considered statistically significant when the measurements were compared. The agreement between biometers was studied by applying a Bland-Altman analysis. Results: The mean CD values obtained using the IOLMaster 500 and 700 biometers were 12.26±0.35 mm and 12.13±0.34 mm, respectively. The mean ACD distance values were 3.61±0.29 mm and 3.62±0.31, for the IOLMaster 500 and 700 biometers, respectively. There were statistically significant differences between the two devices only for CD measurements (p<0.001), but not for ACD measurements (p=0.26). The limits of agreement obtained were wide in both types of measurements, being 0.422 mm for the CD distance and 0.389 mm for the ACD distance. Conclusion: There were statistically significant differences between the IOLMaster 500 and 700 biometers regarding CD but not in ACD measurements in healthy myopic eyes. These differences could be clinically significant in some cases. According to these results, medical judgement should be used to assess whether the two devices could be used interchangeably for CD and ACD measurements during the clinical practice.

8.
J Refract Surg ; 39(4): 229-234, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37040209

RESUMEN

PURPOSE: To analyze the refractive and visual outcomes following cataract surgery and implantation of a trifocal toric intraocular lens (IOL) in eyes with high degrees of corneal astigmatism. METHODS: A total of 29 eyes from 21 patients who underwent implantation of a trifocal toric IOL (FineVision PODFT; PhysIOL) were evaluated in this study. Phacoemulsification with femto-second laser and intraoperative aberrometry were performed in all cases. All IOLs used exhibited a cylinder power of 3.75 diopters (D) or greater. The main outcome measures were refractive error and corrected distance visual acuity (CDVA) and uncorrected distance visual acuity (UDVA) values. Eyes were evaluated during a follow-up period of 5 years. RESULTS: A total of 96.30%, 100%, 95.83%, and 89.47% of eyes were within ±1.00 D at 1, 2, 3, and 5 years postoperatively, respectively. Furthermore, 92.31%, 86.36%, 82.61%, and 84.21% of eyes showed a refractive cylinder value of ±1.00 D at 1, 2, 3, and 5 years postoperatively, respectively. During the entire follow-up period, between 81.48% and 91.30% of eyes showed a CDVA of 20/25 or better. The mean monocular Snellen decimal CDVA values were 0.90 ± 0.12, 0.90 ± 0.11, 0.91 ± 0.11, and 0.90 ± 0.12 at 1, 2, 3, and 5 years postoperatively, respectively. No significant rotation was reported in any eye during follow-up. CONCLUSIONS: The current study suggests that use of this trifocal toric IOL in eyes with high amounts of corneal astigmatism provides accurate refractive outcomes with good distance visual acuity. [J Refract Surg. 2023;39(4):229-234.].


Asunto(s)
Astigmatismo , Enfermedades de la Córnea , Lentes Intraoculares , Humanos , Astigmatismo/cirugía , Implantación de Lentes Intraoculares , Refracción Ocular , Agudeza Visual , Enfermedades de la Córnea/cirugía
9.
J Refract Surg ; 39(3): 150-157, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36892241

RESUMEN

PURPOSE: To evaluate refractive and visual outcomes at different distances after implantation of an isofocal optic design intraocular lens (IOL) following cataract surgery. METHODS: This multicentric, retrospective/prospective, open-label, observational study considered 183 eyes of 109 patients who were implanted with the ISOPURE 123 (PhysIOL) IOL. The main outcome measures were refractive error and monocular and binocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), and distance-corrected intermediate visual acuity (DCIVA) at 66 and 80 cm, uncorrected near visual acuity (UNVA), and distance-corrected near visual acuity (DCNVA) at 40 cm. Binocular visual acuity at different vergences (defocus curve) was also measured. Patients were evaluated at least 120 days postoperatively. RESULTS: A total of 95.7% of the eyes were within ±1.00 diopter (D) and 73.2% of the eyes were within ±0.50 D; the mean postoperative spherical equivalent was -0.12 ± 0.42 D. There were 90.54% and 98.57% of patients presenting a cumulative binocular UDVA and CDVA value of 20/25 or better, respectively; 80.65% and 50.0% of patients presented a binocular DCIVA value of 20/25 or better at 80 and 66 cm, respectively; and 41.94% of patients presented a binocular DCNVA value of 20/40 or better. The through-focus curve showed good visual acuity at far and intermediate distances with a depth of focus value of 1.50 D. No adverse events were reported. CONCLUSIONS: The current study shows that this isofocal optic design IOL provides excellent visual performance for far vision and functional intermediate vision with an extended range of vision. This lens is an effective option for providing functional intermediate vision and correcting aphakia. [J Refract Surg. 2023;39(3):150-157.].


Asunto(s)
Lentes Intraoculares , Facoemulsificación , Humanos , Implantación de Lentes Intraoculares , Seudofaquia , Estudios Prospectivos , Estudios Retrospectivos , Visión Binocular , Refracción Ocular , Diseño de Prótesis
10.
Eur J Ophthalmol ; 33(5): 1773-1785, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36788496

RESUMEN

The purpose of this report is to summarize the visual and refractive outcomes of patients with trifocal toric intraocular lens (IOL) implants. A peer-reviewed literature search in different databases was carried out to identify clinical publications reporting outcomes of patients with this type of implant. The analysis considered information on the sample of eyes, type and power of the trifocal toric IOLs, biometric preoperative data, postoperative refraction, rotational stability, visual acuity at different distances and other analyses undertaken, such as contrast sensitivity or quality of vision questionnaires. 20 clinical studies, encompassing a total of 1404 eyes implanted with three commercially available trifocal toric IOLs, were included in this review. The analysis assessed the outcomes reported for the AT LISA tri toric 939MP IOL, involving 3 articles and 313 eyes; the FineVision toric POD FT IOL, with 7 articles studying 370 eyes, and the AcrySof IQ PanOptix toric IOL, involving 11 articles and 721 eyes. Our assessment of the outcomes of the various studies indicates that the efficacy of the refractive correction (both sphere and cylinder) and visual acuity at different distances was similar between the IOL models. The same was found for the patients' quality of vision and satisfaction levels, in addition to photic phenomena reported. The outcomes summarized in this report lead us to conclude that the use of trifocal toric IOLs allows complete visual restoration over a wide range of distances.


Asunto(s)
Lentes Intraoculares , Facoemulsificación , Humanos , Seudofaquia/cirugía , Satisfacción del Paciente , Diseño de Prótesis , Estudios Prospectivos , Refracción Ocular
11.
Clin Ophthalmol ; 17: 247-258, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36698852

RESUMEN

Purpose: To assess contrast sensitivity and patient reported outcomes after uncomplicated cataract surgery with a new bi-aspheric diffractive trifocal intraocular lens (IOL) implantation. Methods: Twenty-five patients who underwent bilateral implantation with the Asqelio Trifocal TFLIO130C IOL (AST Products Inc., Billerica, MA, USA) were analyzed at 6 months post-surgery. Binocular contrast sensitivity with and without glare was measured under photopic conditions (85 cd/m2) and mesopic conditions (3 cd/m2). Patients were asked to complete the Catquest-9SF patient outcomes questionnaire and a visual symptoms questionnaire. Results: Photopic contrast sensitivity values were either within or above normal levels without glare; when glare was induced, the mean sensitivity values dropped just below normal range. Mesopic contrast sensitivity values were above or within normal range both with and without glare, except for 12 cpd with glare, where the mean fell just below the normal range. Differences in binocular contrast sensitivity threshold values with and without glare were significant for all spatial frequencies tested under both photopic and mesopic conditions (p<0.05). The Catquest-9SF questionnaire outcomes showed that 88% of patients were either satisfied or very satisfied with their sight after the surgery, and in all cases, the results indicated no difficulty in performing different daily activities. The visual symptoms questionnaire indicated no relevant visual symptoms regarding frequency, intensity, or bothersomeness after implantation of the trifocal IOL. Conclusion: This novel bi-aspheric diffractive trifocal IOL provides good contrast sensitivity outcomes under bright and dim lighting conditions. Patients were satisfied with the surgery, with no relevant visual symptoms.

12.
Expert Rev Med Devices ; 19(8): 633-640, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36062739

RESUMEN

INTRODUCTION: Ocular dimensions measurement is extremely important in cataract procedures and refractive surgery. The use of optical techniques for axial measurements has been developed in recent years. AREAS COVERED: The purpose was to summarize the outcomes reported when swept-source optical coherence tomography (SS-OCT) optical biometry failed during axial length measurement. A peer-reviewed literature search was carried out to identify publications reporting clinical outcomes for cataractous eyes measured with SS-OCT optical biometers available on the market. A comprehensive analysis of the available data was performed, focusing on parameters such as the sample of eyes evaluated, failure rates, and specifically, the cataract type when the measurement was not possible. 27 studies were included in this review. In general, SS-OCT biometers lead to only small failure rates when measuring axial length (but in some cases up to 38.49%). In the few cases where the measurement was not possible, the cataract type of the eyes was mainly mature white or grade ≥ IV. SS-OCT optical biometers show good outcomes when measuring axial length in eyes with advanced cataracts. EXPERT OPINION: We believe that the use of SS-OCT technology may be considered the gold standard for measuring axial length in any type of cataract.


Asunto(s)
Longitud Axial del Ojo , Catarata , Humanos , Longitud Axial del Ojo/anatomía & histología , Interferometría/métodos , Reproducibilidad de los Resultados , Biometría/métodos , Catarata/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos
13.
Clin Ophthalmol ; 16: 2521-2530, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35974903

RESUMEN

Purpose: To evaluate the refractive and visual outcomes following cataract surgery and implantation of a new monofocal non-constant aberration aspheric intraocular lens (IOL). Methods: Ninety eyes of 86 patients who underwent implantation the CT LUCIA 621P IOL (Carl Zeiss Meditec AG) were retrospectively analyzed in this study. Main outcome measures were refractive error and monocular corrected distance visual acuity (CDVA) and monocular uncorrected distance visual acuity (UDVA) values. Patients were evaluated at 1-month post-surgery and intra- and post-operative complications were recorded. Results: Eighty percent of the eyes showed a CDVA of 20/25 or better before surgery. The postoperative mean values of monocular distance Snellen decimal UDVA and CDVA were 0.64±0.22 and 0.89±0.13, respectively. All eyes showed the same or better difference between UDVA and CDVA. In relation to the postoperative spherical equivalent, the highest percentage of eyes, 31.11%, was for the range between -0.50 and -0.14D followed by 22.22% for the ±0.13D range. Ninety percent of the eyes were within ±1.00 D and 73.33% of eyes within ±0.50 D. The mean postoperative spherical equivalent was -0.18±0.55D. 37.78% and 76.67% of the eyes showed a value ≤0.50 D and ≤1.00D, respectively, being the mean postoperative refractive cylinder -0.81±0.50D. No adverse events were reported in whole sample intra and postoperatively. Conclusion: The present study shows that cataract surgery with an monofocal non-constant aberration aspheric IOL implantation resulted in good visual performance and refractive outcomes. This lens may be considered as a valid choice for patients in a standard-routine cataract surgery practice.

14.
J Glaucoma ; 31(7): 557-566, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35583510

RESUMEN

PRCIS: The Preserflo Microshunt (PSM) is a safe and effective glaucoma microfiltering implant that significantly reduces the intraocular pressure (IOP), either alone or in combination with phacoemulsification, during the first year after surgery. PURPOSE: The purpose of this study was to assess the safety and efficacy of the PSM for the treatment of open angle glaucoma with 0.2 mg/mL mitomycin C, either alone or in combination with cataract surgery. METHODS: A retrospective, open-label study of 64 eyes with primary open angle glaucoma that underwent PSM implantation and were followed up for at least 9 months. Success was defined as IOP 6-17 mm Hg and a reduction of at least 20%, complete without hypotensive medication, and qualified with medication. Safety was assessed by the incidence of adverse events. Secondary endpoints included mean hypotensive medications, visual acuity, and incidence of needling and surgical revision. RESULTS: A total of 51 eyes underwent PSM alone and 13 underwent PSM+phacoemulsification. In the overall population of the study, the mean IOP was significantly reduced from 22.03±0.7 mm Hg at baseline to 12.7±0.4 mm Hg at the final visit, P <0.0001 (mean follow-up: 11±1.4 mo). The IOP was significantly reduced in both groups ( P <0.0001). Ocular hypotensive medication was reduced significantly from 2.7±0.7 to 0.2±0.5 ( P <0.0001). No significant differences were found in IOP-lowering medication between groups (PSM alone, 0.2±0.08; PSM+phacoemulsification, 0.1±0.1; P =0.2). At the final visit, 70.3% were considered as complete success and 12.5% as qualified success. The most common adverse event was clinical hypotony (7.8%) followed by hyphema (4.7%), and anterior chamber reformation (1.6%). Overall, 1.6% required needling and 15.6% surgical revision to restore the flow. CONCLUSION: Glaucoma surgery with the PSM and mitomycin C was efficacious and safe in the short term, either alone or in combination with cataract surgery, and may be considered a surgical option for lowering IOP in primary open angle glaucoma.


Asunto(s)
Catarata , Glaucoma de Ángulo Abierto , Glaucoma , Facoemulsificación , Antihipertensivos/uso terapéutico , Catarata/complicaciones , Glaucoma/cirugía , Glaucoma de Ángulo Abierto/complicaciones , Glaucoma de Ángulo Abierto/tratamiento farmacológico , Glaucoma de Ángulo Abierto/cirugía , Humanos , Presión Intraocular , Mitomicina , Estudios Retrospectivos , Resultado del Tratamiento
15.
J Refract Surg ; 38(4): 229-234, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35412927

RESUMEN

PURPOSE: To evaluate peripheral refraction and contrast detection sensitivity in pseudophakic patients implanted with a new type of inverted meniscus intraocular lens (IOL) (Art25; Voptica SL) that was designed to provide better peripheral optics. METHODS: One month after cataract surgery, in 87 eyes implanted with the Art25 IOL, peripheral contrast detection sensitivity was measured psychophysically at 40° visual angle, both horizontally and vertically, and compared with a control group of 51 eyes implanted with standard biconvex IOLs. Thirty-one eyes with the Art25 IOL and 28 eyes from the control group were randomly selected to also measure peripheral refraction using a scanning Hartmann-Shack wavefront sensor along 80° in the horizontal meridian. RESULTS: Most patients achieved emmetropia and good visual acuity, and no significant adverse events were observed after cataract surgery with Art25 IOLs. Peripheral contrast detection sensitivity was significantly better (P < .01) in the group with the Art25 IOL in both directions (7.78 ± 3.24 vs 5.74 ± 2.60 vertical, 10.98 ± 5.09 vs 7.47 ± 3.96 horizontal), which was in agreement with the optical quality improvement in the periphery due to a reduction of defocus (1.97 and 1.21 diopters [D] at 40° temporal and nasal sides) and astigmatism (1.17 and 0.37 D at 40° temporal and nasal sides) that was statistically significant (P < .01) from 20° of eccentricity. CONCLUSIONS: Patients implanted with a new inverted meniscus IOL present a reduced amount of peripheral defocus and astigmatism compared to patients implanted with standard biconvex IOLs. This improvement in optical quality leads to better contrast detection sensitivity measured at 40° of eccentricity. [J Refract Surg. 2022;38(4):229-234.].


Asunto(s)
Astigmatismo , Catarata , Lentes Intraoculares , Menisco , Facoemulsificación , Astigmatismo/cirugía , Sensibilidad de Contraste , Humanos , Implantación de Lentes Intraoculares , Seudofaquia/cirugía , Refracción Ocular , Agudeza Visual
16.
J. optom. (Internet) ; 15(1): 1-12, January-March 2022. tab, graf
Artículo en Inglés | IBECS | ID: ibc-204384

RESUMEN

Purpose: To measure lens vault (LV) and to assess its correlation with various ocular parameters in healthy eyes, using for all measurements the same high-resolution swept-source optical coherence tomographer (SS-OCT).Methods: We prospectively recruited 67 Caucasian healthy patients whose mean age was 41.9 ± 12.4 years; only their right eye was included in the study. Data were all recorded with the ANTERION SS-OCT and comprised, for each patient, 5 consecutive measurements of LV, anterior chamber depth (ACD), lens thickness (LT), axial length (AL), white-to-white (WTW) distance, central corneal thickness (CCT), anterior chamber volume (ACV) and spur-to-spur (STS) distance.Results: Mean LV was 0.26 ± 0.23 mm (ranging from -0.24 to 0.78 mm). Data analysis revealed a statistically significant negative correlation between LV and ACD (R=-0.80, p < 0.001), AL (R = -0.36, p = 0.002), and ACV (R = -0.68, p < 0.001), and a positive correlation between LV and LT (R = 0.67, p < 0.001), and age (R = 0.53, p < 0.001). In contrast, no statistically significant correlation was found between LV and WTW (R=-0.17, p = 0.15), CCT (R = 0.11, p = 0.36) or STS (R=-0.10, p = 0.41).Conclusions: Taking into account our findings about intra-parameter correlation levels, we believe that LV should be measured and analyzed together with other ocular parameters in clinical routine practice both for diagnosis and for some refractive surgeries. (AU)


Asunto(s)
Humanos , Adulto , Longitud Axial del Ojo , Cámara Anterior/anatomía & histología , Cámara Anterior/diagnóstico por imagen , Biometría , Cápsula del Cristalino/anatomía & histología , Reproducibilidad de los Resultados , Tomografía de Coherencia Óptica
17.
J Optom ; 15(1): 88-99, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34736867

RESUMEN

PURPOSE: To measure lens vault (LV) and to assess its correlation with various ocular parameters in healthy eyes, using for all measurements the same high-resolution swept-source optical coherence tomographer (SS-OCT). METHODS: We prospectively recruited 67 Caucasian healthy patients whose mean age was 41.9 ±â€¯12.4 years; only their right eye was included in the study. Data were all recorded with the ANTERION SS-OCT and comprised, for each patient, 5 consecutive measurements of LV, anterior chamber depth (ACD), lens thickness (LT), axial length (AL), white-to-white (WTW) distance, central corneal thickness (CCT), anterior chamber volume (ACV) and spur-to-spur (STS) distance. RESULTS: Mean LV was 0.26 ± 0.23 mm (ranging from -0.24 to 0.78 mm). Data analysis revealed a statistically significant negative correlation between LV and ACD (R=-0.80, p < 0.001), AL (R = -0.36, p = 0.002), and ACV (R = -0.68, p < 0.001), and a positive correlation between LV and LT (R = 0.67, p < 0.001), and age (R = 0.53, p < 0.001). In contrast, no statistically significant correlation was found between LV and WTW (R=-0.17, p = 0.15), CCT (R = 0.11, p = 0.36) or STS (R=-0.10, p = 0.41). CONCLUSIONS: Taking into account our findings about intra-parameter correlation levels, we believe that LV should be measured and analyzed together with other ocular parameters in clinical routine practice both for diagnosis and for some refractive surgeries.


Asunto(s)
Cristalino , Tomografía de Coherencia Óptica , Adulto , Cámara Anterior/anatomía & histología , Cámara Anterior/diagnóstico por imagen , Longitud Axial del Ojo , Biometría , Humanos , Cristalino/anatomía & histología , Persona de Mediana Edad , Reproducibilidad de los Resultados
18.
Int Ophthalmol ; 42(1): 177-189, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34424437

RESUMEN

PURPOSE: To assess refractive and visual outcomes following phacoemulsification with femtosecond laser-assisted cataract surgery (FLACS) using intraoperative aberrometry and implantation of a toric intraocular lens (IOL) in eyes with different degrees of astigmatism. METHODS: One hundred two eyes of 70 patients who underwent implantation of the transitional toric 565 Precizon IOL (Ophtec BV) were enrolled. FLACS, capsular tension ring insertion, and intraoperative aberrometry were performed. Main outcome measures were refractive error, uncorrected- and corrected distance snellen decimal visual acuity values (UDVA and CDVA, respectively), and IOL rotation. Specifically, a vector analysis was carried out with J0 and J45 evaluation. Eyes were evaluated 1-year after surgery. RESULTS: Overall, 94.12% (96 eyes) and 100% (102 eyes) of the eyes showed a spherical equivalent (SE) within ± 0.50D and ± 1.00D, respectively. The mean SE and refractive cylinder were - 0.06 ± 0.29D and - 0.23 ± 0.37D, respectively. Vector analysis revealed that 100% of the eyes were within ± 0.50D for the J0 and J45 cylindrical components. The mean toric axis rotation was 1.10 ± 1.71° (from 0° to 5°), 77% (79 eyes), and 100% (102 eyes) of the eyes showed UDVA and CDVA of 20/25, respectively. The postoperative mean values of monocular UDVA and CDVA were 0.88 ± 0.17 and 0.96 ± 0.07 (about 20/20), respectively. No patient required IOL realignment during the postoperative follow-up. CONCLUSIONS: The present study suggests that the use of the Precizon IOL after FLACS, using intraoperative aberrometry in patients with different amounts of astigmatism, provides good visual acuity, accurate refractive outcomes, and excellent rotational stability.


Asunto(s)
Astigmatismo , Catarata , Lentes Intraoculares , Facoemulsificación , Aberrometría , Astigmatismo/diagnóstico , Astigmatismo/etiología , Astigmatismo/cirugía , Humanos , Rayos Láser , Implantación de Lentes Intraoculares , Estudios Prospectivos , Refracción Ocular
19.
Acta Ophthalmol ; 100(1): e192-e203, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33838021

RESUMEN

PURPOSE: To analyse the morphological evolution of filtering blebs with anterior-segment OCT (AS-OCT) and its correlation with intraocular pressure after ab externo SIBS microshunt implantation with mitomycin C (MMC) during a 3-month follow-up period. METHODS: Twenty-eight filtering blebs of 28 patients with open-angle glaucoma were measured horizontally and vertically in the sub-Tenon space with AS-OCT after ab externo SIBS microshunt implantation with MMC. The intraocular pressure (IOP) was monitored simultaneously at each visit. Maturation of and morphological changes in the blebs and correlations with the IOP were recorded. RESULTS: The average median preoperative IOP of 20.7 (range, 12-30) mmHg decreased to 8.5 (range, 4-17), 8.9 (range, 5-17), 10.4 (range, 8-16) and 10.9 (range, 9-15) mmHg at 24 hr, 1 week, 1 month and 3 months, respectively (p < 0.001). A multiform morphology on AS-OCT prevailed at all time points, with a 3.5% rate of a uniform bleb morphology at the first week. The horizontal and vertical diameters of the blebs increased from baseline to the third month. The horizontal expansion (406 ± 127 µm on day 7, p = 0.04, 712 ± 211 µm on day 30, p = 0.02 and 952 ± 218 µm on day 90, p < 0.001) was greater than the vertical expansion (16 ± 18 µm, p = 0.3 on day 1, 63 ± 27 µm, p = 0.02 on day 30 and 137 ± 34 µm, p < 0.001 on day 90) without correlation with the IOP (r = -0.3, p = 0.2). CONCLUSION: Anterior-segment OCT (AS-OCT) of the filtering blebs formed after ab externo SIBS microshunt implantation showed progressive horizontal and vertical expansion of the blebs in the sub-Tenon space, with a significant peak at the first month not significantly correlated with the decrease in the IOP.


Asunto(s)
Segmento Anterior del Ojo/diagnóstico por imagen , Implantes de Medicamentos/administración & dosificación , Cirugía Filtrante/métodos , Glaucoma de Ángulo Abierto/terapia , Presión Intraocular/fisiología , Mitomicina/administración & dosificación , Anciano , Reactivos de Enlaces Cruzados/administración & dosificación , Femenino , Estudios de Seguimiento , Glaucoma de Ángulo Abierto/diagnóstico , Glaucoma de Ángulo Abierto/fisiopatología , Humanos , Masculino , Periodo Posoperatorio , Estudios Prospectivos , Tomografía de Coherencia Óptica/métodos
20.
Ophthalmol Ther ; 11(1): 293-310, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34837167

RESUMEN

INTRODUCTION: To analyze the effects of PRESERFLO on corneal endothelial cell density (ECD). METHODS: Forty-six eyes that underwent PRESERFLO implantation were followed up for 12 months. Specular microscopy was performed preoperatively and at 1, 3, 6, and 12 months postoperatively to measure central ECD and mean monthly reduction (MMR). Anterior segment optical coherence tomography (AS-OCT) was applied to measure the tube-endothelium (TE < 200 µm, 201-500 µm, > 500 µm) distance. The relationship between TE distance and ECD was analyzed with a linear mixed-effects model. RESULTS: Central ECD decreased significantly at 1 year (7.4%, p = 0.04), with an MMR of -15 ± 25 cells/mm2. Regarding TE distance groups, there was an 18% ECD reduction in the < 200 µm group vs. 1% in the > 500 µm group (p = 0.08). Endothelial cell loss was related to TE distance (mean 482.9 ± 238 µm), with a higher rate at 1 month in comparison to 12 months for the same tube position in the anterior chamber (-174.8 ± 65.2 cells/mm2 at 1 month vs. 30.2 ± 11.3 cells/mm2 at 12 months, p < 0.01). From month 6, tubes located > 600 µm from the endothelium showed EC loss close to zero. CONCLUSIONS: The PRESERFLO implant is associated with a loss of EC from the immediate postoperative period that continues over time at lower rates. A shorter TE distance appears to cause more severe ECD loss.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...