1.
Eur J Radiol ; 169: 111191, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37976761

RESUMEN

PURPOSE: Diagnostic reference levels (DRL) and achievable doses (AD) are important tools for radiation dose optimization. Therefore, a prospective study was performed which aimed to establish a multi-parametric, clinical indication based - DRL(DRLCI) and clinical indication - AD (ADCI) for adult CT in Brazil. METHODS: The prospective study included 4787 patients (50 ± 18 years old; male:female 2041:2746) at 13 Brazilian sites that have been submitted to head, paranasal sinus, cervical spine, chest, or abdomen-pelvis CT between January and October 2021 for 13 clinical indications. The sites provided the following information: patient age, gender, weight, height, body mass index[BMI], clinical indications, scanner information(vendor, model, detector configuration), scan parameters (number of scan phases, kV, mA, pitch) and dose-related quantities (CT dose index volume- CTDIvol, dose length product- DLP). Median(AD) and 75th(DRL) percentile CTDIvol and DLP values were estimated for each body region and clinical indications. Non-normal data were analyzed with the Kruskal-Wallis test. RESULTS: In majority of Brazilian sites, body region and clinical indications based DRLs were at or lower than the corresponding DRLs in the US and higher than Europe. Although radiation doses varied significantly for patients in different body mass index groups (p < 0.001), within each body region, there were no differences in radiation doses for different clinical indications (p > 0.1). Radiation doses for 7/13 clinical indications were higher using iterative reconstruction technique than for the filtered back projection. CONCLUSIONS: There was substantial variation in Brazil DRLCI across different institutions with higher doses compared to the European standards. There was also a lack of clinical indication-based protocol and dose optimization based on different clinical indications for the same body region.


Asunto(s)
Niveles de Referencia para Diagnóstico , Tomografía Computarizada por Rayos X , Adulto , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Dosis de Radiación , Estudios Prospectivos , Brasil/epidemiología , Valores de Referencia , Tomografía Computarizada por Rayos X/métodos
2.
Radiat Prot Dosimetry ; 197(3-4): 135-145, 2021 Dec 30.
Artículo en Inglés | MEDLINE | ID: mdl-34875692

RESUMEN

We assessed variations in chest CT usage, radiation dose and image quality in COVID-19 pneumonia. Our study included all chest CT exams performed in 533 patients from 6 healthcare sites from Brazil. We recorded patients' age, gender and body weight and the information number of CT exams per patient, scan parameters and radiation doses (volume CT dose index-CTDIvol and dose length product-DLP). Six radiologists assessed all chest CT exams for the type of pulmonary findings and classified CT appearance of COVID-19 pneumonia as typical, indeterminate, atypical or negative. In addition, each CT was assessed for diagnostic quality (optimal or suboptimal) and presence of artefacts. Artefacts were frequent (367/841), often related to respiratory motion (344/367 chest CT exams with artefacts) and resulted in suboptimal evaluation in mid-to-lower lungs (176/344) or the entire lung (31/344). There were substantial differences in CT usage, patient weight, CTDIvol and DLP across the participating sites.


Asunto(s)
COVID-19 , Brasil , Humanos , Dosis de Radiación , SARS-CoV-2 , Tomografía Computarizada por Rayos X
3.
Radiat Prot Dosimetry ; 195(2): 92-98, 2021 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-34386818

RESUMEN

Computed tomography (CT) provides useful information in patients with known or suspected COVID-19 infection. However, there are substantial variations and challenges in scanner technologies and scan practices that have negative effect on the image quality and can increase radiation dose associated with CT. OBJECTIVE: In this article, we present major issues and challenges with use of CT at five Brazilian CT facilities for imaging patients with known or suspected COVID-19 infection and offer specific mitigating strategies. METHODS: Observational, retrospective and prospective study of five CT facilities from different states and regions of Brazil, with approval of research and ethics committees. RESULTS: The most important issues include frequent use of CT, lack of up-to-date and efficient scanner technologies, over-scanning and patient off-centring. Mitigating strategies can include updating scanner technology and improving scan practices.


Asunto(s)
COVID-19 , Pandemias , Brasil/epidemiología , Humanos , Estudios Prospectivos , Dosis de Radiación , Estudios Retrospectivos , SARS-CoV-2
4.
Phys Med ; 84: 125-131, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33894582

RESUMEN

PURPOSE: Optimization of CT scan practices can help achieve and maintain optimal radiation protection. The aim was to assess centering, scan length, and positioning of patients undergoing chest CT for suspected or known COVID-19 pneumonia and to investigate their effect on associated radiation doses. METHODS: With respective approvals from institutional review boards, we compiled CT imaging and radiation dose data from four hospitals belonging to four countries (Brazil, Iran, Italy, and USA) on 400 adult patients who underwent chest CT for suspected or known COVID-19 pneumonia between April 2020 and August 2020. We recorded patient demographics and volume CT dose index (CTDIvol) and dose length product (DLP). From thin-section CT images of each patient, we estimated the scan length and recorded the first and last vertebral bodies at the scan start and end locations. Patient mis-centering and arm position were recorded. Data were analyzed with analysis of variance (ANOVA). RESULTS: The extent and frequency of patient mis-centering did not differ across the four CT facilities (>0.09). The frequency of patients scanned with arms by their side (11-40% relative to those with arms up) had greater mis-centering and higher CTDIvol and DLP at 2/4 facilities (p = 0.027-0.05). Despite lack of variations in effective diameters (p = 0.14), there were significantly variations in scan lengths, CTDIvol and DLP across the four facilities (p < 0.001). CONCLUSIONS: Mis-centering, over-scanning, and arms by the side are frequent issues with use of chest CT in COVID-19 pneumonia and are associated with higher radiation doses.


Asunto(s)
COVID-19 , Protección Radiológica , Adulto , Brazo , Humanos , Irán , Italia/epidemiología , Pandemias , Dosis de Radiación , SARS-CoV-2