Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Asunto principal
Intervalo de año de publicación
1.
Res Sq ; 2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38746125

RESUMEN

Chronic Obstructive Pulmonary Disease (COPD) is a common, costly, and morbid condition. Pulmonary rehabilitation, close monitoring, and early intervention during acute exacerbations of symptoms represent a comprehensive approach to improve outcomes, but the optimal means of delivering these services is uncertain. Logistical, financial, and social barriers to providing healthcare through face-to-face encounters, paired with recent developments in technology, have stimulated interest in exploring alternative models of care. The Healthy at Home study seeks to determine the feasibility of a multimodal, digitally enhanced intervention provided to participants with COPD longitudinally over six months. This paper details the recruitment, methods, and analysis plan for the study, which is recruiting 100 participants in its pilot phase. Participants were provided with several integrated services including a smartwatch to track physiological data, a study app to track symptoms and study instruments, access to a mobile integrated health program for acute clinical needs, and a virtual comprehensive pulmonary support service. Participants shared physiologic, demographic, and symptom reports, electronic health records, and claims data with the study team, facilitating a better understanding of their symptoms and potential care needs longitudinally. The Healthy at Home study seeks to develop a comprehensive digital phenotype of COPD by tracking and responding to multiple indices of disease behavior and facilitating early and nuanced responses to changes in participants' health status. This study is registered at Clinicaltrials.gov (NCT06000696).

2.
Ann Intern Med ; 176(7): 975-982, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37399548

RESUMEN

BACKGROUND: The performance of rapid antigen tests (Ag-RDTs) for screening asymptomatic and symptomatic persons for SARS-CoV-2 is not well established. OBJECTIVE: To evaluate the performance of Ag-RDTs for detection of SARS-CoV-2 among symptomatic and asymptomatic participants. DESIGN: This prospective cohort study enrolled participants between October 2021 and January 2022. Participants completed Ag-RDTs and reverse transcriptase polymerase chain reaction (RT-PCR) testing for SARS-CoV-2 every 48 hours for 15 days. SETTING: Participants were enrolled digitally throughout the mainland United States. They self-collected anterior nasal swabs for Ag-RDTs and RT-PCR testing. Nasal swabs for RT-PCR were shipped to a central laboratory, whereas Ag-RDTs were done at home. PARTICIPANTS: Of 7361 participants in the study, 5353 who were asymptomatic and negative for SARS-CoV-2 on study day 1 were eligible. In total, 154 participants had at least 1 positive RT-PCR result. MEASUREMENTS: The sensitivity of Ag-RDTs was measured on the basis of testing once (same-day), twice (after 48 hours), and thrice (after a total of 96 hours). The analysis was repeated for different days past index PCR positivity (DPIPPs) to approximate real-world scenarios where testing initiation may not always coincide with DPIPP 0. Results were stratified by symptom status. RESULTS: Among 154 participants who tested positive for SARS-CoV-2, 97 were asymptomatic and 57 had symptoms at infection onset. Serial testing with Ag-RDTs twice 48 hours apart resulted in an aggregated sensitivity of 93.4% (95% CI, 90.4% to 95.9%) among symptomatic participants on DPIPPs 0 to 6. When singleton positive results were excluded, the aggregated sensitivity on DPIPPs 0 to 6 for 2-time serial testing among asymptomatic participants was lower at 62.7% (CI, 57.0% to 70.5%), but it improved to 79.0% (CI, 70.1% to 87.4%) with testing 3 times at 48-hour intervals. LIMITATION: Participants tested every 48 hours; therefore, these data cannot support conclusions about serial testing intervals shorter than 48 hours. CONCLUSION: The performance of Ag-RDTs was optimized when asymptomatic participants tested 3 times at 48-hour intervals and when symptomatic participants tested 2 times separated by 48 hours. PRIMARY FUNDING SOURCE: National Institutes of Health RADx Tech program.


Asunto(s)
COVID-19 , Humanos , COVID-19/diagnóstico , Estudios Prospectivos , SARS-CoV-2 , Reacción en Cadena de la Polimerasa , Cognición , Sensibilidad y Especificidad
3.
J Clin Transl Sci ; 7(1): e120, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37313378

RESUMEN

Background: Rapid antigen detection tests (Ag-RDT) for SARS-CoV-2 with emergency use authorization generally include a condition of authorization to evaluate the test's performance in asymptomatic individuals when used serially. We aim to describe a novel study design that was used to generate regulatory-quality data to evaluate the serial use of Ag-RDT in detecting SARS-CoV-2 virus among asymptomatic individuals. Methods: This prospective cohort study used a siteless, digital approach to assess longitudinal performance of Ag-RDT. Individuals over 2 years old from across the USA with no reported COVID-19 symptoms in the 14 days prior to study enrollment were eligible to enroll in this study. Participants throughout the mainland USA were enrolled through a digital platform between October 18, 2021 and February 15, 2022. Participants were asked to test using Ag-RDT and molecular comparators every 48 hours for 15 days. Enrollment demographics, geographic distribution, and SARS-CoV-2 infection rates are reported. Key Results: A total of 7361 participants enrolled in the study, and 492 participants tested positive for SARS-CoV-2, including 154 who were asymptomatic and tested negative to start the study. This exceeded the initial enrollment goals of 60 positive participants. We enrolled participants from 44 US states, and geographic distribution of participants shifted in accordance with the changing COVID-19 prevalence nationwide. Conclusions: The digital site-less approach employed in the "Test Us At Home" study enabled rapid, efficient, and rigorous evaluation of rapid diagnostics for COVID-19 and can be adapted across research disciplines to optimize study enrollment and accessibility.

4.
medRxiv ; 2023 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-36865199

RESUMEN

Background: The performance of rapid antigen tests for SARS-CoV-2 (Ag-RDT) in temporal relation to symptom onset or exposure is unknown, as is the impact of vaccination on this relationship. Objective: To evaluate the performance of Ag-RDT compared with RT-PCR based on day after symptom onset or exposure in order to decide on 'when to test'. Design Setting and Participants: The Test Us at Home study was a longitudinal cohort study that enrolled participants over 2 years old across the United States between October 18, 2021 and February 4, 2022. All participants were asked to conduct Ag-RDT and RT-PCR testing every 48 hours over a 15-day period. Participants with one or more symptoms during the study period were included in the Day Post Symptom Onset (DPSO) analyses, while those who reported a COVID-19 exposure were included in the Day Post Exposure (DPE) analysis. Exposure: Participants were asked to self-report any symptoms or known exposures to SARS-CoV-2 every 48-hours, immediately prior to conducting Ag-RDT and RT-PCR testing. The first day a participant reported one or more symptoms was termed DPSO 0, and the day of exposure was DPE 0. Vaccination status was self-reported. Main Outcome and Measures: Results of Ag-RDT were self-reported (positive, negative, or invalid) and RT-PCR results were analyzed by a central laboratory. Percent positivity of SARS-CoV-2 and sensitivity of Ag-RDT and RT-PCR by DPSO and DPE were stratified by vaccination status and calculated with 95% confidence intervals. Results: A total of 7,361 participants enrolled in the study. Among them, 2,086 (28.3%) and 546 (7.4%) participants were eligible for the DPSO and DPE analyses, respectively. Unvaccinated participants were nearly twice as likely to test positive for SARS-CoV-2 than vaccinated participants in event of symptoms (PCR+: 27.6% vs 10.1%) or exposure (PCR+: 43.8% vs. 22.2%). The highest proportion of vaccinated and unvaccinated individuals tested positive on DPSO 2 and DPE 5-8. Performance of RT-PCR and Ag-RDT did not differ by vaccination status. Ag-RDT detected 78.0% (95% Confidence Interval: 72.56-82.61) of PCR-confirmed infections by DPSO 4. For exposed participants, Ag-RDT detected 84.9% (95% CI: 75.0-91.4) of PCR-confirmed infections by day five post-exposure (DPE 5). Conclusions and Relevance: Performance of Ag-RDT and RT-PCR was highest on DPSO 0-2 and DPE 5 and did not differ by vaccination status. These data suggests that serial testing remains integral to enhancing the performance of Ag-RDT.

5.
medRxiv ; 2023 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-35982663

RESUMEN

Background: Rapid antigen tests (Ag-RDT) for SARS-CoV-2 with Emergency Use Authorization generally include a condition of authorization to evaluate the test's performance in asymptomatic individuals when used serially. Objective: To describe a novel study design to generate regulatory-quality data to evaluate serial use of Ag-RDT in detecting SARS-CoV-2 virus among asymptomatic individuals. Design: Prospective cohort study using a decentralized approach. Participants were asked to test using Ag-RDT and molecular comparators every 48 hours for 15 days. Setting: Participants throughout the mainland United States were enrolled through a digital platform between October 18, 2021 and February 15, 2022. Ag-RDTs were completed at home, and molecular comparators were shipped to a central laboratory. Participants: Individuals over 2 years old from across the U.S. with no reported COVID-19 symptoms in the 14 days prior to study enrollment were eligible to enroll in this study. Measurements: Enrollment demographics, geographic distribution, and SARS-CoV-2 infection rates are reported. Key Results: A total of 7,361 participants enrolled in the study, and 492 participants tested positive for SARS-CoV-2, including 154 who were asymptomatic and tested negative to start the study. This exceeded the initial enrollment goals of 60 positive participants. We enrolled participants from 44 U.S. states, and geographic distribution of participants shifted in accordance with the changing COVID-19 prevalence nationwide. Limitations: New, complex workflows required significant operational and data team support. Conclusions: The digital site-less approach employed in the 'Test Us At Home' study enabled rapid, efficient, and rigorous evaluation of rapid diagnostics for COVID-19, and can be adapted across research disciplines to optimize study enrollment and accessibility.

6.
medRxiv ; 2023 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-35982680

RESUMEN

Background: Performance of rapid antigen tests for SARS-CoV-2 (Ag-RDT) varies over the course of an infection, and their performance in screening for SARS-CoV-2 is not well established. We aimed to evaluate performance of Ag-RDT for detection of SARS-CoV-2 for symptomatic and asymptomatic participants. Methods: Participants >2 years old across the United States enrolled in the study between October 2021 and February 2022. Participants completed Ag-RDT and molecular testing (RT-PCR) for SARS-CoV-2 every 48 hours for 15 days. This analysis was limited to participants who were asymptomatic and tested negative on their first day of study participation. Onset of infection was defined as the day of first positive RT-PCR result. Sensitivity of Ag-RDT was measured based on testing once, twice (after 48-hours), and thrice (after 96 hours). Analysis was repeated for different Days Post Index PCR Positivity (DPIPP) and stratified based on symptom-status. Results: In total, 5,609 of 7,361 participants were eligible for this analysis. Among 154 participants who tested positive for SARS-CoV-2, 97 were asymptomatic and 57 had symptoms at infection onset. Serial testing with Ag-RDT twice 48-hours apart resulted in an aggregated sensitivity of 93.4% (95% CI: 89.1-96.1%) among symptomatic participants on DPIPP 0-6. Excluding singleton positives, aggregated sensitivity on DPIPP 0-6 for two-time serial-testing among asymptomatic participants was lower at 62.7% (54.7-70.0%) but improved to 79.0% (71.0-85.3%) with testing three times at 48-hour intervals. Discussion: Performance of Ag-RDT was optimized when asymptomatic participants tested three-times at 48-hour intervals and when symptomatic participants tested two-times separated by 48-hours.

7.
JAMA Netw Open ; 5(8): e2228885, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-36018589

RESUMEN

Importance: Widespread distribution of rapid antigen tests is integral to the US strategy to address COVID-19; however, it is estimated that few rapid antigen test results are reported to local departments of health. Objective: To characterize how often individuals in 6 communities throughout the United States used a digital assistant to log rapid antigen test results and report them to their local departments of health. Design, Setting, and Participants: This prospective cohort study is based on anonymously collected data from the beneficiaries of the Say Yes! Covid Test program, which distributed more than 3 000 000 rapid antigen tests at no cost to residents of 6 communities (Louisville, Kentucky; Indianapolis, Indiana; Fulton County, Georgia; O'ahu, Hawaii; Ann Arbor and Ypsilanti, Michigan; and Chattanooga, Tennessee) between April and October 2021. A descriptive evaluation of beneficiary use of a digital assistant for logging and reporting their rapid antigen test results was performed. Interventions: Widespread community distribution of rapid antigen tests. Main Outcomes and Measures: Number and proportion of tests logged and reported to the local department of health through the digital assistant. Results: A total of 313 000 test kits were distributed, including 178 785 test kits that were ordered using the digital assistant. Among all distributed kits, 14 398 households (4.6%) used the digital assistant, but beneficiaries reported three-quarters of their rapid antigen test results to their state public health departments (30 965 tests reported of 41 465 total test results [75.0%]). The reporting behavior varied by community and was significantly higher among communities that were incentivized for reporting test results vs those that were not incentivized or partially incentivized (90.5% [95% CI, 89.9%-91.2%] vs 70.5%; [95% CI, 70.0%-71.0%]). In all communities, positive tests were less frequently reported than negative tests (60.4% [95% CI, 58.1%-62.8%] vs 75.5% [95% CI, 75.1%-76.0%]). Conclusions and Relevance: These results suggest that application-based reporting with incentives may be associated with increased reporting of rapid tests for COVID-19. However, increasing the adoption of the digital assistant may be a critical first step.


Asunto(s)
COVID-19 , Recolección de Datos , Georgia , Humanos , Estudios Prospectivos , Autoevaluación , Estados Unidos
8.
medRxiv ; 2022 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-35411338

RESUMEN

Importance: Wide-spread distribution of rapid-antigen tests is integral to the United States' strategy to address COVID-19; however, it is estimated that few rapid-antigen test results are reported to local departments of health. Objective: To characterize how often individuals in six communities throughout the United States used a digital assistant to log rapid-antigen test results and report them to their local Department of Health. Design: This prospective cohort study is based on anonymously collected data from the beneficiaries of The Say Yes! Covid Test program, which distributed 3,000,000 rapid antigen tests at no cost to residents of six communities between April and October 2021. We provide a descriptive evaluation of beneficiaries' use of digital assistant for logging and reporting their rapid antigen test results. Main Outcome and Measures: Number and proportion of tests logged and reported to the Department of Health through the digital assistant. Results: A total of 178,785 test kits were ordered by the digital assistant, and 14,398 households used the digital assistant to log 41,465 test results. Overall, a small proportion of beneficiaries used the digital assistant (8%), but over 75% of those who used it reported their rapid antigen test results to their state public health department. The reporting behavior varied between communities and was significantly different for communities that were incentivized for reporting test results (p < 0.001). In all communities, positive tests were less reported than negative tests (60.4% vs 75.5%; p<0.001). Conclusions and Relevance: These results indicate that app-based reporting with incentives may be an effective way to increase reporting of rapid tests for COVID-19; however, increasing the adoption of the digital assistant is a critical first step.

9.
Front Mol Biosci ; 8: 752824, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34692773

RESUMEN

Protein splicing is a post-translational process by which an intervening polypeptide, or intein, catalyzes its own removal from the flanking polypeptides, or exteins, concomitant with extein ligation. Although inteins are highly abundant in the microbial world, including within several human pathogens, they are absent in the genomes of metazoans. As protein splicing is required to permit function of essential proteins within pathogens, inteins represent attractive antimicrobial targets. Here we review key proteins interrupted by inteins in pathogenic mycobacteria and fungi, exciting discoveries that provide proof of concept that intein activity can be inhibited and that this inhibition has an effect on the host organism's fitness, and bioanalytical methods that have been used to screen for intein activity. We also consider potential off-target inhibition of hedgehog signaling, given the similarity in structure and function of inteins and hedgehog autoprocessing domains.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...