Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Exp Biol Med (Maywood) ; 242(16): 1617-1632, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28409533

RESUMEN

This article describes our next generation human Liver Acinus MicroPhysiology System (LAMPS). The key demonstration of this study was that Zone 1 and Zone 3 microenvironments can be established by controlling the oxygen tension in individual devices over the range of ca. 3 to 13%. The oxygen tension was computationally modeled using input on the microfluidic device dimensions, numbers of cells, oxygen consumption rates of hepatocytes, the diffusion coefficients of oxygen in different materials and the flow rate of media in the MicroPhysiology System (MPS). In addition, the oxygen tension was measured using a ratiometric imaging method with the oxygen sensitive dye, Tris(2,2'-bipyridyl) dichlororuthenium(II) hexahydrate (RTDP) and the oxygen insensitive dye, Alexa 488. The Zone 1 biased functions of oxidative phosphorylation, albumin and urea secretion and Zone 3 biased functions of glycolysis, α1AT secretion, Cyp2E1 expression and acetaminophen toxicity were demonstrated in the respective Zone 1 and Zone 3 MicroPhysiology System. Further improvements in the Liver Acinus MicroPhysiology System included improved performance of selected nonparenchymal cells, the inclusion of a porcine liver extracellular matrix to model the Space of Disse, as well as an improved media to support both hepatocytes and non-parenchymal cells. In its current form, the Liver Acinus MicroPhysiology System is most amenable to low to medium throughput, acute through chronic studies, including liver disease models, prioritizing compounds for preclinical studies, optimizing chemistry in structure activity relationship (SAR) projects, as well as in rising dose studies for initial dose ranging. Impact statement Oxygen zonation is a critical aspect of liver functions. A human microphysiology system is needed to investigate the impact of zonation on a wide range of liver functions that can be experimentally manipulated. Because oxygen zonation has such diverse physiological effects in the liver, we developed and present a method for computationally modeling and measuring oxygen that can easily be implemented in all MPS models. We have applied this method in a liver MPS in which we are then able to control oxygenation in separate devices and demonstrate that zonation-dependent hepatocyte functions in the MPS recapitulate what is known about in vivo liver physiology. We believe that this advance allows a deep experimental investigation on the role of zonation in liver metabolism and disease. In addition, modeling and measuring oxygen tension will be required as investigators migrate from PDMS to plastic and glass devices.


Asunto(s)
Hepatocitos/metabolismo , Hígado/metabolismo , Procedimientos Analíticos en Microchip/métodos , Microfluídica/métodos , Consumo de Oxígeno/fisiología , Oxígeno/metabolismo , Acetaminofén/toxicidad , Línea Celular , Hígado Graso/patología , Glucosa/metabolismo , Glucólisis/fisiología , Humanos , Interleucina-6/metabolismo , Dispositivos Laboratorio en un Chip , Lipopolisacáridos , Macrófagos/citología , Monocitos/citología , Fosforilación Oxidativa , Factor de Necrosis Tumoral alfa/metabolismo , Células U937
2.
Anal Bioanal Chem ; 406(26): 6455-68, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25168111

RESUMEN

This review covers recent advances in sampling fluid from the extracellular space of brain tissue by electroosmosis (EO). Two techniques, EO sampling with a single fused-silica capillary and EO push-pull perfusion, have been developed. These tools were used to investigate the function of membrane-bound enzymes with outward-facing active sites, or ectoenzymes, in modulating the activity of the neuropeptides leu-enkephalin and galanin in organotypic-hippocampal-slice cultures (OHSCs). In addition, the approach was used to determine the endogenous concentration of a thiol, cysteamine, in OHSCs. We have also investigated the degradation of coenzyme A in the extracellular space. The approach provides information on ectoenzyme activity, including Michaelis constants, in tissue, which, as far as we are aware, has not been done before. On the basis of computational evidence, EO push-pull perfusion can distinguish ectoenzyme activity with a ~100 µm spatial resolution, which is important for studies of enzyme kinetics in adjacent regions of the rat hippocampus.


Asunto(s)
Electroósmosis/instrumentación , Espacio Extracelular/metabolismo , Hipocampo/enzimología , Perfusión/instrumentación , Animales , Coenzima A/metabolismo , Diseño de Equipo , Hipocampo/metabolismo , Humanos , Proteínas de la Membrana/metabolismo , Neuropéptidos/metabolismo
3.
Anal Chem ; 85(24): 12020-7, 2013 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-24215585

RESUMEN

We have developed an approach that integrates electroosmotic perfusion of tissue with a substrate-containing solution and online microfluidic analysis of products, in this case thiols. Using this approach we have tracked the metabolism of cystamine, pantethine and CoA in the extracellular space of organotypic hippocampal slice cultures (OHSCs). Currently, little is known about coenzyme A (CoA) biodegradation and even less is known about the regulation and kinetic characteristics for this sequential multienzyme reaction. We found that the steady state percentage yields of cysteamine from cystamine and pantethine during the transit through OHSCs were 91% ± 4% (SEM) and 0.01%-0.03%, respectively. The large difference in the yields of cysteamine can be used to explain the drugs' different toxicities and clinical effectiveness against cystinosis. The kinetic parameters of the enzyme reaction catalyzed by the ectoenzyme pantetheinase are KM,C/α = 4.4 ± 1.1 mM and Vmax,C = 29 ± 3 nM/s, where α is the percentage yield of pantethine to pantetheine through disulfide exchange. We estimate that the percentage yield of pantethine to pantetheine through disulfide exchange is approximately 0.5%. Based on the formation rate of cysteamine in the OHSCs, we obtained the overall apparent Michaelis constant and maximum reaction rate for sequential, extracellular CoA degradation in an in situ environment, which are K'M = 16 ± 4 µM, V'max = 7.1 ± 0.5 nM/s. Kinetic parameters obtained in situ, although difficult to measure, are better representations of the biochemical flux in the living organism than those from isolated enzymes in vitro.


Asunto(s)
Coenzima A/metabolismo , Cistamina/metabolismo , Electroósmosis/métodos , Técnicas Analíticas Microfluídicas/métodos , Panteteína/análogos & derivados , Perfusión/métodos , Integración de Sistemas , Calibración , Espacio Extracelular/metabolismo , Hipocampo/citología , Panteteína/metabolismo
4.
Anal Chem ; 85(6): 3095-103, 2013 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-23330713

RESUMEN

We demonstrate an all-electric sampling/derivatization/separation/detection system for the quantitation of thiols in tissue cultures. Extracellular fluid collected from rat organotypic hippocampal slice cultures (OHSCs) by electroosmotic flow through an 11 cm (length) × 50 µm (i.d.) sampling capillary is introduced to a simple microfluidic chip for derivatization, continuous flow-gated injection, separation, and detection. With the help of a fluorogenic, thiol-specific reagent, ThioGlo-1, we have successfully separated and detected the extracellular levels of free reduced cysteamine, homocysteine, and cysteine from OHSCs within 25 s in a 23 mm separation channel with a confocal laser-induced fluorescence (LIF) detector. Attention to the conductivities of the fluids being transported is required for successful flow-gated injections. When the sample conductivity is much higher than the run buffer conductivities, the electroosmotic velocities are such that there is less fluid coming by electroosmosis into the cross from the sample/reagent channel than is leaving by electroosmosis into the separation and waste channels. The resulting decrease in the internal fluid pressure in the injection cross pulls flow from the gated channel. This process may completely shut down the gated injection. Using a glycylglycine buffer with physiological osmolarity but only 62% of physiological conductivity and augmenting the conductivity of the run buffers solved this problem. Quantitation is by standard additions. Concentrations of cysteamine, homocysteine, and cysteine in the extracellular space of OHSCs are 10.6 ± 1.0 nM (n = 70), 0.18 ± 0.01 µM (n = 53), and 11.1 ± 1.2 µM (n = 70), respectively. This is the first in situ quantitative estimation of endogenous cysteamine in brain tissue. Extracellular levels of homocysteine and cysteine are comparable with other reported values.


Asunto(s)
Cisteamina/análisis , Cisteína/análisis , Electroósmosis/métodos , Hipocampo/química , Homocisteína/análisis , Técnicas Analíticas Microfluídicas/métodos , Animales , Animales Recién Nacidos , Espacio Extracelular/química , Técnicas de Cultivo de Órganos , Ratas , Ratas Sprague-Dawley
5.
Anal Chem ; 82(17): 7267-73, 2010 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-20698502

RESUMEN

Reduced glutathione (GSH) has been determined by fluorescence detection after derivatization together with a variety of separations. The reactions between GSH and fluorescent reagents usually are carried out during the sample pretreatment and require minutes to hours for complete reactions. For continuous monitoring of GSH, it would be very convenient to have an integrated microdevice that could perform online precolumn derivatization, separation, and detection. Heretofore, thiol-specific fluorogenic reagents require fairly long reaction times, preventing effective online precolumn derivatization. We demonstrate here that the fluorogenic, thiol-specific reagent, ThioGlo-1, reacts rapidly enough for efficient precolumn derivatization. The second order rate constant for the reaction of GSH and reagent (pH 7.5, room temperature) is 2.1 x 10(4) M(-1)s(-1). The microchip integrates this precolumn derivatization, continuous flow gated sampling, separation, and detection on a single device. We have validated this device for monitoring GSH concentration continuously by studying the kinetics of glutathione reductase (EC 1.8.1.7), an enzyme that catalyzes the reduction of oxidized glutathione (GSSG) to GSH in the presence of beta-NADPH (beta-nicotinamide adenine dinucleotide phosphate, reduced form) as a reducing cofactor. During the experiment, GSH being generated in the enzymatic reaction was labeled with ThioGlo-1 as it passed through a mixing channel on the microfluidic chip. Derivatization reaction products were introduced into the analysis channel every 10 s using flow gated injections of 0.1 s. Baseline separation of the internal standard, ThioGlo-1, and the fluorescently labeled GSH was successfully achieved within 4.5 s in a 9 mm separation channel. Relative standard deviations of the peak area, peak height, and full width at half-maximum (fwhm) for the internal standard were 2.5%, 2.0%, and 1.0%, respectively, with migration time reproducibility for the internal standard of less than 0.1% RSD in any experiment. The GSH concentration and mass detection limit were 4.2 nM and approximately 10(-18) mol, respectively. The Michaelis constants (K(m)) for GSSG and beta-NADPH were found to be 40 +/- 11 and 4.4 +/- 0.6 muM, respectively, comparable with those obtained from UV/vis spectrophotometric measurements. These results show that this system is capable of integrating derivatization, injection, separation, and detection for continuous GSH determinations.


Asunto(s)
Colorantes Fluorescentes/química , Glutatión/análisis , Naftalenos/química , Pirroles/química , Espectrometría de Fluorescencia/métodos , Glutatión/química , Glutatión/aislamiento & purificación , Concentración de Iones de Hidrógeno , Cinética , Técnicas Analíticas Microfluídicas , NADP/química , Oxidación-Reducción , Temperatura
7.
J Chromatogr A ; 1127(1-2): 207-13, 2006 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-16820153

RESUMEN

A comprehensive two-dimensional liquid chromatography system was constructed on the combination of size exclusion chromatography (SEC) and reverse phase liquid chromatography (RPLC). The first dimension used a SEC column with 300 mm x 8mm i.d., packed with Toyopearl HW-40S. The column was eluted with 0.05 mol/l Tris-HCl (pH 6.9) at a flow rate of 0.4 ml/min. The second dimension used a RPLC column with 100 mm x 4.6mm i.d., which was operated in gradient form at a flow rate of 1.0 ml/min. An automatic switching valve was used to collect the effluent of the SEC column every 3 min, and the effluent was automatically injected into the RPLC column. Mass spectrometer was used for peak identification. This system was used to separate Qingkailing injection, a traditional Chinese medicine (TCM). The result showed that the total peak capacity of this system could reach 1134 and the qualitative analysis of seven chemical components of the Qingkailing injection was accomplished by this system. The results show that comprehensive two-dimensional liquid chromatography system is of great importance and high value in the separation of complex TCM.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Medicamentos Herbarios Chinos/aislamiento & purificación , Cromatografía Líquida de Alta Presión/instrumentación , Medicamentos Herbarios Chinos/análisis , Espectrometría de Masas
8.
Artículo en Inglés | MEDLINE | ID: mdl-16490406

RESUMEN

Two non-self-complementary 17-mer double-stranded DNA (dsDNA) with four different central base pairs were designed to systematically investigate the binding affinity and sequence specificity of berberine with dsDNA by capillary zone electrophoresis (CZE). The data analysis with the Kenndler model proved only low affinity between dsDNA and berberine and suggested some weak binding preference of berberine for AATT-containing to GGCC-containing dsDNA. The binding constant, Ka, between berberine and dsDNA(AB) was about (1.0 +/- 0.7) x 10(3) M(-1). In addition, the separation of single-stranded DNA (ssDNA) from dsDNA under simple electrophoretic conditions enabled CZE to be a potentially alternative tool to check the extent of DNA annealing, which is usually done by the time-consuming and labor-intensive slab electrophoresis.


Asunto(s)
Berberina/química , ADN/química , Electroforesis Capilar/métodos , Secuencia de Bases , Cartilla de ADN
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...