A large proportion of patients referred for transcatheter tricuspid valve intervention (TTVI) will have the presence of a cardiac implantable electronic device (CIED). In such patients, surgical correction of tricuspid regurgitation (TR) is associated with high rates of morbidity and mortality. Transvenous lead extraction (TLE) could potentially ameliorate CIED-induced TR; however, it carries inherent risks and frequently does not result in TR improvement. As multiple TTVI devices are in trial to gain regulatory approval, understanding which therapy is most appropriate among patients with a CIED is essential. This review centers on the nonsurgical treatment, including TLE and transcatheter tricuspid valve repair and replacement options, aimed at enhancing outcomes in patients with TR who also have concurrent CIEDs.

3.
Struct Heart ; 8(4): 100301, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39100585

RESUMEN

Although existing guidelines offer strong recommendations for single valvular dysfunction, the growing prevalence of multiple valvular heart disease (MVHD) in our aging population is challenging the clarity of clinical guidance. Traditional diagnostic modalities, such as echocardiography, face inherent constraints in precisely quantifying valvular dysfunction due to the hemodynamic interactions that occur with multiple valve involvement. Therefore, many patients with MVHD present at a later stage in their disease course and with an elevated surgical risk. The expansion of transcatheter therapy for the treatment of valvular heart disease has added new opportunities for higher-risk patients. However, the impact of isolated valve therapies on patients with MVHD is still not well understood. This review focuses on the etiology, diagnostic challenges, and therapeutic considerations for some of the most common concomitant valvular abnormalities that occur in our daily clinic population.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38952304

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has become an established method of aortic stenosis treatment but suffers from the risk of heart block and pacemaker requirement. Risk stratification for patients who may develop heart block remains imperfect. Simultaneously, myocardial fibrosis as measured by cardiac magnetic resonance imaging (CMR) has been demonstrated as a prognostic indicator of ventricular recovery and mortality following TAVR. However, the association of CMR-based measures of myocardial fibrosis with post-TAVR conduction disturbances has not yet been explored. AIMS: We evaluated whether myocardial fibrosis, as measured by late gadolinium enhancement and extracellular volume (ECV) from CMR would be associated with new conduction abnormalities following TAVR. METHODS: One hundred seventy patients who underwent CMR within 2 months before TAVR were retrospectively reviewed. Septal late gadolinium enhancement (LGE) and ECV measurements were made as surrogates for replacement and interstitial fibrosis respectively. New conduction abnormalities were defined by the presence of transient or permanent atrioventricular block, new bundle branch blocks, and need for permanent pacemaker. Association of myocardial fibrosis and new conduction derangements were tested using receiver operator curve (ROC) and regression analysis in patients with and without pre-existing conduction issues. RESULTS: Forty-six (27.1%) patients developed post-TAVR conduction deficits. ECV was significantly higher among patients who experienced new conduction defects (26.2 ± 3.45% vs. 24.7% ± 4.15%, p value: 0.020). A greater fraction of patients that had new conduction defects had an elevated ECV of ≥26% (54.3% vs. 36.3%, p value: 0.026). ECV ≥ 26% was independently associated with the development of new conduction defects (odds ratio [OR]: 2.364, p value: 0.030). ROC analysis revealed a significant association of ECV with new conduction defects with an area under the receiver operating characteristic curve (AUC) of 0.632 (95% confidence interval: 0.555-0.705, p value: 0.005). The combination of prior right bundle branch block (RBBB) and ECV revealed a greater AUC of 0.779 (0.709-0.839, p value: <0.001) than RBBB alone (Delong p value: 0.049). No association of LGE/ECV with new conduction defects was observed among patients with pre-existing conduction disease. Among patients without baseline conduction disease, ECV was independently associated with the development of new conduction deficits (OR: 3.685, p value: 0.008). CONCLUSION: The present study explored the association of myocardial fibrosis, as measured by LGE and ECV with conduction deficits post-TAVR. Our results demonstrate an association of ECV, and thereby interstitial myocardial fibrosis, with new conduction derangement post-TAVR and introduce ECV as a potentially new risk stratification tool to identify patients at higher risk for needing post-TAVR surveillance and/or permanent pacemaker.

5.
Catheter Cardiovasc Interv ; 103(6): 995-1003, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38662126

RESUMEN

BACKGROUND: Limited data exists regarding incidence, progression, and predictors of left atrial appendage (LAA) sealing after transcatheter LAA closure. We aimed to evaluate the incidence, progression, and predictive factors associated with LAA sealing after LAA closure. METHODS: This study includes patients who underwent successful LAA closure with Watchman FLX device and had both pre- and postprocedural computed tomography (CT). Postprocedural CT was performed 45 days after LAA closure and used to evaluate residual LAA patency. Patient who had residual LAA patency at 45 days underwent 1-year follow-up CT. RESULTS: A total of 105 patients (mean age: 75.2 ± 9.6 years; 53.3% female) who underwent successful LAA closure with Watchman FLX device and had pre- and postprocedural CT at 45 days were included. Residual patency was observed in 35 (33.3%) patients: 21 (20.0%) patients showed complete contrast opacification in LAA (complete LAA patency) while 14 (13.3%) patients showed contrast opacification only in the distal LAA (distal LAA patency). Among patients with residual LAA patency at 45 days, the rate of LAA sealing at 1 year was significantly higher in the distal LAA patency group than in the complete LAA patency group (75.0% vs. 16.7%; p = 0.019). Increased depth oversizing was associated with both distal LAA patency and complete LAA patency. CONCLUSION: Postprocedural CT at 45 days detected patent LAA in one-third of patients after LAA closure. LAA sealing was more frequently observed at 1 year among the distal LAA patency group than the complete LAA patency group.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Cateterismo Cardíaco , Valor Predictivo de las Pruebas , Diseño de Prótesis , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/fisiopatología , Femenino , Masculino , Anciano , Anciano de 80 o más Años , Factores de Riesgo , Resultado del Tratamiento , Factores de Tiempo , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Estudios Retrospectivos , Incidencia , Tomografía Computarizada por Rayos X , Tomografía Computarizada Multidetector
7.
JACC Case Rep ; 29(9): 102298, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38550912

RESUMEN

Coronary reaccess can be difficult after valve-in-valve transcatheter aortic valve replacement. We present a case whereby prior valve-in-valve transcatheter aortic valve replacement created difficulty with coronary reaccess. Computed tomography-fluoroscopy fusion imaging was used for guidance to successfully engage the coronary arteries and perform percutaneous coronary intervention.

8.
Catheter Cardiovasc Interv ; 103(6): 1035-1041, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38545668

RESUMEN

A distinctive complication with balloon-expandable (BE) THV platforms such as the Edwards Sapien (Edwards Lifescience) is the possibility of balloon rupture during THV deployment. Balloon rupture is a rare occurrence that can result in stroke due to fragment embolism, incomplete THV expansion, and/or vascular injury upon retrieval of the balloon. Careful evaluation of preoperative computed tomography is essential to identify high-risk cases. While annular and left ventricular outflow tract (LVOT) calcification are widely acknowledged as common risks for balloon injury, it's essential to note that balloon injury can manifest at various anatomical sites. In this review, we discuss the mechanism behind balloon rupture, methods to identify cases at a heightened risk of balloon injury, approaches to mitigate the risk of rupture, and percutaneous retrieval strategies.


Asunto(s)
Valvuloplastia con Balón , Falla de Equipo , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Valvuloplastia con Balón/instrumentación , Catéteres Cardíacos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento
9.
Cardiovasc Revasc Med ; 63: 23-30, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38267285

RESUMEN

BACKGROUND: Percutaneous left atrial appendage occlusion (LAAO) has emerged as a non-pharmacologic alternative to oral anticoagulation in reducing stroke risk in AF patients. However, patients with mitral valve disease (MVD), who are expected to have a significantly greater risk of left atrium (LA) thrombus formation and embolic stroke were excluded from randomized trials examining percutaneous LAAO. To address this gap, we present a national registry analysis of the use of LAAO among patients with MVD. METHODS: Using the National Readmissions Database, we performed a retrospective review of all hospitalizations for LAAO identified between September 2015 and November 2019. Of these, patients with ICD-10 codes for MVD were identified. Propensity matched (PSM) analysis was used to compare patients with MVD with a matched sample of patients undergoing LAAO with non-valvular AF. Outcomes examined included all-cause mortality, stroke, major bleeding, pericardial effusion (PE), and tamponade. RESULTS: 51,540 patients who underwent LAAO without a history of MVD and 3777 with a history of MVD were identified. Crude analysis demonstrated the odds of mortality, PE, and cardiac tamponade during index hospitalization to be higher in the MVD group. The length of stay and cost of index hospitalization were also slightly greater for the MVD group. A sample of 7649 patients (MVD: 3777 MVD and no MVD: 3872) were selected for PSM analysis with similar comorbidities across the two groups. In the PSM comparison, MVD was associated with higher risk of PE. The MVD group had a slightly higher rate of readmissions the association with PE remained at 30-day readmission (OR: 2.099 [1.360-3.238], p-value: <0.001). CONCLUSION: To our knowledge, this is the first study examining the use of LAAO among MVD patients. Our findings suggest that patients with MVD who underwent LAAO had a higher risk of post-procedural PE without an increase in mortality, stroke, or major bleeding. These results provide a rationale for considering LAAO as part of the stroke prevention strategy among patients with valvular AF.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Cateterismo Cardíaco , Bases de Datos Factuales , Válvula Mitral , Readmisión del Paciente , Sistema de Registros , Accidente Cerebrovascular , Humanos , Apéndice Atrial/fisiopatología , Masculino , Femenino , Estudios Retrospectivos , Anciano , Factores de Riesgo , Resultado del Tratamiento , Válvula Mitral/fisiopatología , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Estados Unidos/epidemiología , Persona de Mediana Edad , Factores de Tiempo , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Medición de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/mortalidad , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/mortalidad , Fibrilación Atrial/terapia , Fibrilación Atrial/complicaciones , Anciano de 80 o más Años , Enfermedades de las Válvulas Cardíacas/mortalidad , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/fisiopatología , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Costos de Hospital
10.
Catheter Cardiovasc Interv ; 103(1): 129-136, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37786977

RESUMEN

BACKGROUND: While studies have shown the advantages of computed tomography angiography (CTA) over transesophageal echocardiography (TEE) in left atrial appendage closure (LAAC) preprocedural planning for WATCHMAN™ legacy and FLX devices, there has been no reported long-term data for this approach. OBJECTIVES: We sought to evaluate long-term outcomes using CTA-based preprocedural planning for LAAC using the WATCHMAN™ device. METHODS: A prospective analysis of 231 consecutive patients who underwent LAAC in a single, large academic hospital in the United States was conducted over a 5-year period. CTA-guided preprocedural planning was performed in all. Procedural success, adverse events, length of procedure, number of devices used, and length of stay were evaluated. Rates of death, cerebral embolism, systemic embolism, and major and minor bleeding were recorded. Adjusted predicted stroke and major bleeding rates were derived from CHA2DS2-Vasc and HAS-BLED scores, respectively. RESULTS: From January 26, 2017, to November 23, 2021, 231 patients underwent LAAC with CTA preprocedural planning by two operating physicians. The mean age of patients was 76.5 ± 8.4. 59.7% of patients were male. Mean CHA2DS2VASc and HAS-BLED scores were 4.5 ± 1.4 and 3.9 ± 0.9, respectively. All procedures were performed with intracardiac echo (100%). The procedural success rate was 99.1%. The CTA sizing strategy accurately predicted the implant size in 93.5% of patients. Mean number of devices used was 1.10 ± 0.3. Peri-procedural complication rate was 2.2%. 6 patients were lost to follow-up. Mean follow-up was 608.94 days with a total of 377.04 patient years. Median follow-up period of 368 days (interquartile range: 209-1067 days). There were 51 deaths from all causes (13.52 per 100 patient-years), 10 cases of cerebral embolism (2.65 per 100 patient-years), 2 cases of systemic embolism (0.53 per 100 patient-years), 17 cases of major bleeding (4.50 per 100 patient-years), and 31 cases of minor bleeding (8.2 per 100 patient-years). All-cause mortality at 1, 2, and 3 years was 12.7%, 20.9%, and 29.2%, respectively. CV event rates at 1, 2, and 3 years were 2.1%, 6.6%, and 10.5%, respectively. CONCLUSIONS: CTA-based preprocedural planning is accurate in predicting device size for LAAC and associated with excellent clinical outcomes at 5 years.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Embolia , Embolia Intracraneal , Accidente Cerebrovascular , Humanos , Masculino , Femenino , Estudios de Seguimiento , Cierre del Apéndice Auricular Izquierdo , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Fibrilación Atrial/complicaciones , Angiografía por Tomografía Computarizada , Resultado del Tratamiento , Embolia Intracraneal/diagnóstico por imagen , Embolia Intracraneal/etiología , Embolia Intracraneal/prevención & control , Apéndice Atrial/diagnóstico por imagen , Accidente Cerebrovascular/etiología , Hemorragia , Ecocardiografía Transesofágica/efectos adversos
12.
Catheter Cardiovasc Interv ; 103(1): 226-229, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37870093

RESUMEN

Peri-device leak after left atrial appendage closure (LAAC) is often treated with endovascular coils, plugs, or second occluders. This is the first study reporting the Amulet device used for peri-device leak. An 80-year-old male with paroxysmal atrial fibrillation and recurrent falls with head trauma who underwent LAAC with a 24 mm Watchman 2.5 device 3 years ago at another institution was referred to our clinic for management of the peri-device leak. Transesophageal echocardiogram showed persistent residual peri-device leak with 5 mm width along the Coumadin ridge aspect of the device. Computed tomography (CT) also showed the peri-device leak with width of 6 mm and complete opacification of left atrial appendage (LAA). Importantly, CT demonstrated that the Watchman 2.5 device was deployed at distal LAA, leaving the proximal part of LAA with length of 10 mm from ostium. Under general anesthesia, a 22 mm Amulet device was deployed successfully with complete sealing of LAA. Procedure planning is the key to minimize the risk of peri-device leak or device-related thrombosis. Careful assessment of LAA anatomy using multimodality images for peri-device leak after LAAC helped optimal treatment strategy including second LAAC with different type of devices.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Masculino , Humanos , Anciano de 80 o más Años , Cierre del Apéndice Auricular Izquierdo , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Warfarina , Ecocardiografía Transesofágica , Apéndice Atrial/diagnóstico por imagen
13.
J Cardiovasc Electrophysiol ; 34(10): 2076-2083, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37592406

RESUMEN

INTRODUCTION: We studied the impact of the use of three-dimensional multidetector computed tomography (3D-MDCT) and fluoroscopy fusion on percutaneous left atrial appendage occlusion (LAAO) procedures in relation to procedure time, contrast volume, fluoroscopy time, and total radiation. METHODS: This was a single-center, prospective, single-blinded, randomized control trial. Patients meeting criteria for LAAO were randomized to undergo LAAO with the WATCHMAN FLXTM device with and without 3D-MDCT-fluoroscopy fusion guidance using a prespecified protocol using computed tomography angiography for WATCHMAN FLXTM sizing, moderate sedation, and intracardiac echocardiography for procedural guidance. RESULTS: Overall, 59 participants were randomly assigned to the fusion (n = 33) or no fusion (n = 26) groups. The median (interquartile range) age was 79 (75-83) years, 24 (41%) were female, and 55 (93%) were Caucasian. The median CHA2 DS2 VASc and HASBLED scores were 5 (4-6) and 3 (3-4), respectively. At the time of the study, 51 (53%) patients were on a direct acting oral anticoagulant. There were no significant differences between the fusion and no fusion groups in procedure time (52.4 ± 15.4 vs. 56.8 ± 19.5 min, p = .36), mean contrast volume used (33.8 ± 12.0 vs. 29.6 ± 11.5 mls, p = .19), mean fluoroscopy time (31.3 ± 9.9 vs. 28.9 ± 8.7 min, p = .32), mean radiation dose (1177 ± 969 vs. 1091 ± 692 mGy, p = .70), and radiation dose product curve (23.9 ± 20.5 vs. 35.0 ± 49.1 Gy cm2 , p = .29). There was no periprosthetic leak in the two groups in the immediate 1-month postprocedure follow-up periods. CONCLUSIONS: There was no significant difference with and without 3D-MDCT-fluoroscopy fusion in procedure time, contrast volume use, radiation dose, and radiation dose product.

14.
Am J Cardiol ; 202: 176-181, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37441832

RESUMEN

Atrial fibrillation is the most common arrhythmia in patients with underlying malignancy. Patients with cancer have a higher risk of bleeding, and at the same time, carry an elevated risk of thromboembolism related to the hypercoagulable state, type of cancer, and anticancer treatment, rendering safe anticoagulation challenging in this population. Left atrial appendage closure is an alternative treatment option in patients with atrial fibrillation and high bleeding risk; however, the data on patients with cancer are limited. Our study aimed to compare the long-term outcomes in patients with cancer receiving left atrial appendage closure using the WATCHMAN device. This is a prospective, single-center study comparing outcomes in 389 patients who underwent percutaneous left atrial appendage closure using the WATCHMAN device over 5 years in a single, large academic hospital in the United States. The postprocedural outcomes of mortality, stroke, and major bleeding were evaluated in patients with and without cancer. Our study included 57 patients with cancer and 332 without cancer. The baseline characteristics were similar between the 2 groups. Metastatic disease was present in 16.4% of patients, and 25% were receiving active treatment at the time of the procedure. The median follow-up time was 354 (interquartile range 85 to 790) days. There was no difference in mortality (hazard ratio [HR] 1.3, 95% confidence interval [CI] 0.72 to 2.35, p = 0.38), major bleeding episodes (HR 1.2, 95% CI 0.45 to 3.33, p = 0.68), and stroke (HR 0.64, 95% CI 0.19 to 2.21, p = 0.49) at 3 years after the procedure in patients with and without cancer. There was no difference in the composite outcome (postprocedural mortality, stroke, and major bleeding) between the 2 groups (HR 1.25, CI 0.75 to 2.07, p = 0.38). Percutaneous left atrial appendage closure in patients with cancer appears to be safe and has a similar long-term risk compared with patients without cancer.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Neoplasias , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Anticoagulantes/uso terapéutico , Apéndice Atrial/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Hemorragia/inducido químicamente , Neoplasias/complicaciones , Neoplasias/patología
15.
JACC Cardiovasc Interv ; 16(13): 1626-1635, 2023 07 10.
Artículo en Inglés | MEDLINE | ID: mdl-37438029

RESUMEN

BACKGROUND: The latest-generation Evolut FX TAVR system (Medtronic) offers several potential design improvements over its predecessors, but early reported experience has been limited. OBJECTIVES: This study sought to report our multicenter, limited market release, first-in-human experience of transcatheter aortic valve replacement (TAVR) with the Evolut FX system and compare it with a single-center PRO+ (Medtronic) experience. METHODS: From June 27 to September 16, 2022, 226 consecutive patients from 9 US centers underwent transfemoral TAVR with the Evolut FX system for native aortic stenosis (89.4%) or prosthetic valve degeneration (10.6%). Commissural alignment was defined as 0° to 30° between native and FX commissures. Patient, anatomical, and procedural characteristics were retrospectively reviewed, and 30-day clinical and echocardiographic outcomes per Valve Academic Research Consortium-3 definitions were reported. RESULTS: Of 226 patients, 34.1% were low risk, 4% had a bicuspid valve, and 11.5% had a horizontal root (≥60°). Direct Inline sheath (Medtronic) was used in 67.6% and Lunderquist stiff wire (Cook Medical) in 35.4% of cases. Optimal hat marker orientation during deployment was achieved in 98.4%, with commissural alignment in 96.5%. At 30 days, 14.3% mild, 0.9% moderate, and no severe paravalvular leak were observed. Compared with the Evolut PRO+ experience from 1 center, FX had a more symmetrical implantation with shallower depth at the left coronary cusp (P < 0.001), fewer device recaptures (26.1% vs 39.5%; P = 0.004), and improved commissural alignment (96.5% vs 80.2%; P < 0.001). CONCLUSIONS: The Evolut FX system demonstrated favorable 30-day outcomes with a significant improvement over PRO+ in achieving commissural alignment, fewer device recaptures, and more symmetrical implantation. These features may benefit younger patients undergoing TAVR with the supra-annular, self-expanding valve, where lifetime management would be important.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Catéteres
18.
J Invasive Cardiol ; 35(2): E108-E109, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36735874

RESUMEN

The Cor-Knot surgical tying device (LSI Solutions) is an automated suture fastener with a titanium-crimpable sleeve that facilitates a fast and secure knot. The device is an alternative to hand tying, minimizing operation time, and its increasing use is anticipated for minimally invasive cardiac surgeries or in patients with small surgical anatomy. As its use expands, the likelihood of encountering this knotting device during structural interventions may increase. In this case, during the TAVR procedure, the coplanar angle estimated from preoperative computed tomography scan was easily adjusted referencing the line of Cor-Knot in her aortic annulus without administrating contrast despite poor radiodensity from the Trifecta valve. In the coplanar view, the TAVR valve depth was well appreciated in reference to the Cor-Knot line and the TAVR valve was deployed under controlled pacing without contrast use. We achieved mean aortic pressure gradient of 9 mm Hg without paravalvular leakage or conduction abnormalities. She was discharged to home the next day without renal injury.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Femenino , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo
19.
Europace ; 25(4): 1441-1450, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36794441

RESUMEN

AIMS: Patients who undergo permanent pacemaker (PPM) implantation after transcatheter aortic valve replacement (TAVR) have a worse outcome. The aim of this study was to identify risk factors of worse outcomes in patients with post-TAVR PPM implantation. METHODS AND RESULTS: This is a single-centre, retrospective study of consecutive patients who underwent post-TAVR PPM implantation from 11 March 2011 to 9 November 2019. Clinical outcomes were evaluated by landmark analysis with cut-off at 1 year after the PPM implantation. Of the 1389 patients underwent TAVR during the study duration and a total of 110 patients were included in the final analysis. Right ventricular pacing burden (RVPB) ≥ 30% at 1 year was associated with a higher likelihood of heart failure (HF) readmission [adjusted hazard ratio (aHR): 6.333; 95% confidence interval [CI]: 1.417-28.311; P = 0.016] and composite endpoint of overall death and/or HF (aHR: 2.453; 95% CI: 1.040-5.786; P = 0.040). The RVPB ≥30% at 1 year was associated with higher atrial fibrillation burden (24.1 ± 40.6% vs. 1.2 ± 5.3%; P = 0.013) and a decrease in left ventricular ejection fraction (-5.0 ± 9.8% vs. + 1.1 ± 7.9%; P = 0.005). The predicting factors of the RVPB ≥30% at 1 year were the presence of RVPB ≥40% at 1 month and the valve implantation depth measured from non-coronary cusp ≥4.0 mm (aHR: 57.808; 95% CI: 12.489-267.584; P < 0.001 and aHR: 6.817; 95% CI: 1.829-25.402; P = 0.004). CONCLUSIONS: The RVPB ≥30% at 1 year was associated with worse outcomes. Clinical benefit of minimal RV pacing algorithms and biventricular pacing needs to be investigated.


Asunto(s)
Estenosis de la Válvula Aórtica , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estimulación Cardíaca Artificial/efectos adversos , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Función Ventricular Izquierda , Factores de Riesgo , Válvula Aórtica/cirugía