1.
Eur J Oral Sci ; 131(4): e12937, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37212743

RESUMEN

This study evaluated the influence of different implant diameters, insertion torques, and transmucosal heights on the loosening of abutments installed on short implants, after mechanical cycling. The Morse taper connection implants (n = 96) tested were 5 mm high, divided according to the platform diameter: 4 or 6 mm. A universal abutment was coupled to each implant (with different transmucosal heights: 1 or 5 mm). The sets were subdivided into 20- and 32-Ncm torque. After the cycle fatigue test, the detorque values were measured with a digital torque indicator. After mechanical cycling, the mean detorque values obtained for the abutment with 20-Ncm insertion torque were lower than for implants with 32-Ncm insertion torque, regardless of the platform diameter or transmucosal height. In the 20-Ncm torque group, there was no statistically significant difference in the detorque values between platform diameters or transmucosal heights. Otherwise, for 32-Ncm sets, a smaller platform diameter (4 mm), and a longer transmucosal height (5 mm) showed the lowest detorque values. In conclusion, implants placed with 32-Ncm insertion torque and abutments with 1 mm transmucosal height and a 6 mm implant diameter demonstrated the highest detorque values.


Asunto(s)
Diseño de Implante Dental-Pilar , Implantes Dentales , Torque , Pilares Dentales , Ensayo de Materiales , Estrés Mecánico , Tornillos Óseos , Análisis del Estrés Dental
2.
J Oral Implantol ; 44(6): 423-426, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30011229

RESUMEN

The aim of this study was to measure and record the universal transmucosal abutment height, and then evaluate whether it influenced loosening of the abutment screw by analyzing the torque and detorque values after mechanical cycling. Thirty-six implants, model CM Unitite, with internal conical connections (3.5 × 10 mm) and respective universal prosthetic abutments (n = 36, 3.25 × 6 mm), were divided into three groups (n = 12 each) with respective transmucosal heights of 0.8, 3.5, and 5.5 mm. Insertion torque of 20 Ncm was used in accordance with the manufacturer's specifications. Afterward, the samples were submitted to fatigue tests consisting of 500,000 cycles at a frequency of 2Hz, a dynamic compressive load of 120N, and an angle of 30°. The detorque values were measured with a digital torque meter and tabulated to perform statistical analyses; a level of significance of 5% was adopted. The mean detorque values (SD) obtained were 22.83 (6.30), 22.5 (5.45), and 19.41 (4.69) Ncm for transmucosal abutments with heights of 0.8, 3.5, and 5.5 mm, respectively, and showed no statistically significant difference ( P = .262). The authors of this study concluded that the transmucosal height of prosthetic abutments submitted to mechanical fatigue did not influence the detorque values.


Asunto(s)
Pilares Dentales , Diseño de Implante Dental-Pilar , Implantes Dentales , Análisis del Estrés Dental , Estrés Mecánico , Torque