Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Cardiovasc Comput Tomogr ; 12(3): 257-260, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29486988

RESUMEN

AIM: To assess the association of coronary artery geometry with the severity of coronary artery disease (CAD). METHODS: 73 asymptomatic individuals at increased risk of CAD due to peripheral vascular disease (18 women, mean age 63.5 ±â€¯8.2 years) underwent coronary computed tomography angiography (coronary CTA) using first generation dual-source CT. Curvature and tortuosity of the coronary arteries were quantified using semi-automatically generated centerlines. Measurements were performed for individual segments and for the entire artery. Coronary segments were labeled according to the presence of significant stenosis, defined as >70% luminal narrowing, and the presence of plaque. Comparisons were made by segment and by artery, using linear mixed models. RESULTS: Overall, median curvature and tortuosity were, respectively, 0.094 [0.071; 0.120] and 1.080 [1.040; 1.120] on a per-segment level, and 0.096 [0.078; 0.118] and 1.175 [1.090; 1.420] on a per-artery level. Curvature was associated with significant stenosis at a per-segment (p < 0.001) and per-artery level (p = 0.002). Curvature was 16.7% higher for segments with stenosis, and 13.8% higher for arteries with stenosis. Tortuosity was associated with significant stenosis only at the per-segment level (p = 0.002). Curvature was related to the presence of plaque at the per-segment (p < 0.001) and per-artery level (p < 0.001), tortuosity was only related to plaque at the per-segment level (p < 0.001). CONCLUSION: Coronary artery geometry as derived from coronary CTA is related to the presence of plaque and significant stenosis.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/tratamiento farmacológico , Vasos Coronarios/diagnóstico por imagen , Anciano , Enfermedad de la Arteria Coronaria/patología , Estenosis Coronaria/patología , Vasos Coronarios/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Placa Aterosclerótica , Valor Predictivo de las Pruebas , Interpretación de Imagen Radiográfica Asistida por Computador , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
2.
Eur Radiol ; 27(1): 138-148, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27108299

RESUMEN

OBJECTIVES: To meta-analyze complication rate in computed tomography (CT)-guided transthoracic lung biopsy and associated risk factors. METHODS: Four databases were searched from 1/2000 to 8/2015 for studies reporting complications in CT-guided lung biopsy. Overall and major complication rates were pooled and compared between core biopsy and fine needle aspiration (FNA) using the random-effects model. Risk factors for complications in core biopsy and FNA were identified in meta-regression analysis. RESULTS: For core biopsy, 32 articles (8,133 procedures) were included and for FNA, 17 (4,620 procedures). Pooled overall complication rates for core biopsy and FNA were 38.8 % (95 % CI: 34.3-43.5 %) and 24.0 % (95 % CI: 18.2-30.8 %), respectively. Major complication rates were 5.7 % (95 % CI: 4.4-7.4 %) and 4.4 % (95 % CI: 2.7-7.0 %), respectively. Overall complication rate was higher for core biopsy compared to FNA (p < 0.001). For FNA, larger needle diameter was a risk factor for overall complications, and increased traversed lung parenchyma and smaller lesion size were risk factors for major complications. For core biopsy, no significant risk factors were identified. CONCLUSIONS: In CT-guided lung biopsy, minor complications were common and occurred more often in core biopsy than FNA. Major complication rate was low. For FNA, smaller nodule diameter, larger needle diameter and increased traversed lung parenchyma were risk factors for complications. KEY POINTS: • Minor complications are common in CT-guided lung biopsy • Major complication rate is low in CT-guided lung biopsy • CT-guided lung biopsy complications occur more often in core biopsy than FNA • Major complication rate is similar in core biopsy and FNA • Risk factors for FNA are larger needle diameter, smaller lesion size.


Asunto(s)
Biopsia Guiada por Imagen/efectos adversos , Neoplasias Pulmonares/diagnóstico , Pulmón/diagnóstico por imagen , Neumotórax/epidemiología , Tomografía Computarizada por Rayos X/métodos , Biopsia con Aguja Fina/efectos adversos , Biopsia con Aguja Gruesa/efectos adversos , Salud Global , Humanos , Incidencia , Estudios Retrospectivos
3.
Int J Cardiovasc Imaging ; 27(6): 787-94, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20972707

RESUMEN

To assess the accuracy of (semi-)automatic measurements of left ventricular (LV) functional parameters in cardiac dual-source computed tomography (DSCT) compared to manually adjusted measurements in three different workstations. Forty patients, who underwent cardiac DSCT, were included (31 men, mean age 58 ± 14 years). Multiphase reconstructions were made with ten series at every 10% of the RR-interval. LV function analysis was performed on three different, commercially available workstations. On all three workstations, end-systolic volume (ESV), end-diastolic volume (EDV), LV ejection fraction (LVEF) and myocardial mass (MM) were calculated as automatically as possible. With the same DSCT datasets, LV functional parameters were also calculated with as many manual adjustments as needed for accurate assessment for all three software tools. For both semi-automatic as well as manual methods, time needed for evaluation was recorded. Paired t-tests were employed to calculate differences in LV functional parameters. Repeated measurements were performed to determine intra-observer and inter-observer variability. (Semi-)automatic measurements revealed a good correlation with manually adjusted measurements for Vitrea (LVEF r = 0.93, EDV r = 0.94, ESV r = 0.98 and MM r = 0.94) and Aquarius (LVEF r = 0.96, EDV r = 0.94, ESV r = 0.98 and MM r = 0.96). Also, good correlation was obtained for Circulation, except for LVEF (LVEF r = 0.45, EDV r = 0.93, ESV r = 0.92 and MM r = 0.86). However, statistically significant differences were found between (semi-)automatically and manually adjusted measurements for LVEF (P < 0.05) and ESV (P < 0.001) in Vitrea, all LV functional parameters in Circulation (P < 0.001) and EDV, ESV and MM (<0.001) in Aquarius Workstation. (Semi-)automatic measurement of LV functional parameters is feasible, but significant differences were found for at least two different functional parameters in all three workstations. Therefore, expert manual correction is recommended at all times.


Asunto(s)
Interpretación de Imagen Radiográfica Asistida por Computador , Programas Informáticos , Tomografía Computarizada por Rayos X , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Adulto , Anciano , Anciano de 80 o más Años , Automatización de Laboratorios , Femenino , Humanos , Masculino , Persona de Mediana Edad , Países Bajos , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Volumen Sistólico , Disfunción Ventricular Izquierda/fisiopatología
4.
Eur J Radiol ; 80(3): 755-66, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21112169

RESUMEN

PURPOSE: To compare left ventricular (LV) function assessment using five different software tools on the same dual source computed tomography (DSCT) datasets with the results of MRI. MATERIALS AND METHODS: Twenty-six patients, undergoing cardiac contrast-enhanced DSCT were included (20 men, mean age 59±12 years). Reconstructions were made at every 10% of the RR-interval. Function analysis was performed with five different, commercially available workstations. In all software tools, semi-automatic LV function measurements were performed, with manual corrections if necessary. Within 0-22 days, all 26 patients were scanned on a 1.5 T MRI-system. Bland-Altman analysis was performed to calculate limits of agreement between DSCT and MRI. Pearson's correlation coefficient was calculated to assess the correlation between the different DSCT software tools and MRI. Repeated measurements were performed to determine intraobserver and interobserver variability. RESULTS: For all five DSCT workstations, mean LV functional parameters correlated well with measurements on MRI. Bland-Altman analysis of the comparison of DSCT and MRI showed acceptable limits of agreement. Best correlation and limits of agreement were obtained by DSCT software tools with software algorithms comparable to MRI software. CONCLUSION: The five different DSCT software tools we examined have interchangeable results of LV functional parameters compared to regularly analysed results by MRI. The best correlation and the narrowest limits of agreement were found when the same software algorithm was used for both DSCT and MRI examinations, therefore our advice for clinical practice is to always evaluate images with the same type of post-processing tools in follow-up.


Asunto(s)
Algoritmos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Programas Informáticos , Tomografía Computarizada por Rayos X/métodos , Disfunción Ventricular Izquierda/diagnóstico , Adolescente , Adulto , Anciano , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Validación de Programas de Computación , Adulto Joven
5.
Eur Radiol ; 19(12): 2919-30, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19588147

RESUMEN

The purpose of the study was to assess the reliability of (semi-) automatic left ventricular (LV) function measurements using three different software packages on the same dual-source computed tomography (DSCT) datasets and to compare agreement among the software packages. Forty consecutive patients, undergoing cardiac DSCT were included (31 men, mean age 58±14 years). LV function analysis was performed with all three software packages. ANOVA testing was used to determine the difference among the repeated measurements and the difference among the software packages. Bland-Altman plots were computed to describe the agreement among the software packages. No significant difference was found among the repeated measurements. In the comparison of the three software packages, a significant difference was observed when measurements were used with minimal user interaction. When end-diastolic and end-systolic phases were manually set, there was no overall significant difference, but in 12.5% of patients a large (>10%) difference in LVEF was found. All three software packages have good intraobserver variability, but the results of the three packages were significantly different. For clinical use, one should be aware of the clinical impact of possible segmentation flaws when (semi-)automatic LV function assessment is used.


Asunto(s)
Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
Eur Radiol ; 18(11): 2425-32, 2008 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18651148

RESUMEN

The purpose of this study is to assess the capability of dual-source computed tomography (DSCT) in evaluating coronary artery anomalies. Early detection and evaluation of coronary artery anomalies is essential because of their potential association with myocardial ischemia and sudden death. In 16 patients (12 men, mean age 50 +/- 14 years), anomalous coronary arteries were detected on contrast-enhanced DSCT in a patient cohort of 230 individuals (incidence of 7%). Six different types of anomalies were diagnosed (three fistula, four anomalies of the circumflex artery, four anomalous right coronary arteries, three anomalies of the left coronary artery, one absent left main coronary artery, and one left coronary artery arising from the pulmonary trunk). Of the 16 patients, 10 also underwent conventional coronary angiography (CAG). Retrospective evaluation of the CAGs by an experienced interventional cardiologist resulted in a precise diagnosis in 50% of patients. With DSCT, sufficient image quality and exact visualization of the aberrant anatomy were achieved in all patients. Therefore, DSCT seems to be an accurate diagnostic tool for examining the precise origin, course, and shape of aberrant coronary arteries.


Asunto(s)
Angiografía Coronaria/métodos , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
7.
Eur Radiol ; 18(9): 1800-8, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18491099

RESUMEN

Therapy advice based on dual-source computed tomography (DSCT) in comparison with coronary angiography (CAG) was investigated and the results evaluated after 1-year follow-up. Thirty-three consecutive patients (mean age 61.9 years) underwent DSCT and CAG and were evaluated independently. In an expert reading (the "gold standard"), CAG and DSCT examinations were evaluated simultaneously by an experienced radiologist and cardiologist. Based on the presence of significant stenosis and current guidelines, therapy advice was given by all readers blinded from the results of other readings and clinical information. Patients were treated based on a multidisciplinary team evaluation including all clinical information. In comparison with the gold standard, CAG had a higher specificity (91%) and positive predictive value (PPV) (95%) compared with DSCT (82% and 91%, respectively). DSCT had a higher sensitivity (96%) and negative predictive value (NPV) (89%) compared with CAG (91% and 83%, respectively). The DSCT-based therapy advice did not lead to any patient being denied the revascularization they needed according to the multidisciplinary team evaluation. During follow-up, two patients needed additional revascularization. The high NPV for DSCT for revascularization assessment indicates that DSCT could be safely used to select patients benefiting from medical therapy only.


Asunto(s)
Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/cirugía , Revascularización Miocárdica/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Femenino , Humanos , Masculino , Selección de Paciente , Cuidados Preoperatorios/métodos , Pronóstico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Cirugía Asistida por Computador/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...