Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Res Pract Thromb Haemost ; 7(2): 100083, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36915865

RESUMEN

Background: During percutaneous transluminal coronary angioplasty (PTCA), activated clotting time (ACT) measurements are recommended to attest a correct anticoagulation level and, if needed, to administer further unfractionated heparin (UFH) to obtain a therapeutic ACT value. Our clinical routine led us to observe that smokers had lower ACT values after standardized UFH administration during PTCA. Procoagulant status in smokers is well documented. Objectives: To determine whether tobacco negatively affects UFH anticoagulation during PTCA when evaluated by ACT. Methods: The ACT-TOBACCO trial is a single-center, noninterventional, prospective study. The primary end point is the comparison of ACT values after standardized UFH administration between active smokers and nonsmokers (active smoker group vs nonsmoker group) requiring coronary angiography followed by PTCA. The main secondary end points include ACT comparison after the first and second standardized UFH administration according to the patient's smoking status (active, ex-, or nonsmoker) and the clinical presentation of ischemic cardiomyopathy: stable (silent ischemia or stable angina) or unstable (unstable angina or acute coronary syndrome without or with ST-segment elevation). Conclusions: To the best of our knowledge, ACT values during PTCA between smokers and nonsmokers have not previously been compared. As current PTCA procedures increase in complexity and duration, the understanding of procoagulant risk factors such as smoking and the need for reliable anticoagulation monitoring becomes essential to balance hemorrhagic risk against thrombotic risk.

2.
Saudi J Biol Sci ; 30(3): 103582, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36852413

RESUMEN

Antimicrobial susceptibility testing is an essential task for selecting appropriate antimicrobial agents to treat infectious diseases. Constant evolution has been observed in methods used in the diagnostic microbiology laboratories. Disc diffusion or broth microdilution are classical and conventional phenotypic methods with long turnaround time and labour-intensive but still widely practiced as gold-standard. Scientists are striving to develop innovative, novel and faster methods of antimicrobial susceptibility testing to be applicable for routine microbiological laboratory practice and research. To meet the requirements, there is an increasing trend towards automation, genotypic and micro/nano technology-based innovations. Automation in detection systems and integration of computers for online data analysis and data sharing are giant leaps towards versatile nature of automated methods currently in use. Genotypic methods detect a specific genetic marker associated with resistant phenotypes using molecular amplification techniques and genome sequencing. Microfluidics and microdroplets are recent addition in the continuous advancement of methods that show great promises with regards to safety and speed and have the prospect to identify and monitor resistance mechanisms. Although genotypic and microfluidics methods have many exciting features, however, their applications into routine clinical laboratory practice warrant extensive validation. The main impetus behind the evolution of methods in antimicrobial susceptibility testing is to shorten the overall turnaround time in obtaining the results and to enhance the ease of sample processing. This comprehensive narrative review summarises major conventional phenotypic methods and automated systems currently in use, and highlights principles of some of the emerging genotypic and micro/nanotechnology-based methods in antimicrobial susceptibility testing.

3.
Sens Actuators B Chem ; 351: 130975, 2022 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-36568876

RESUMEN

As the world has been facing several deadly virus crises, including Zika virus disease, Ebola virus disease, severe acute respiratory syndrome (SARS), Middle East respiratory syndrome (MERS), and Coronavirus disease 2019 (COVID-19), lateral flow assays (LFAs), which require minimal equipment for point-of-care of viral infectious diseases, are garnering much attention. Accordingly, there is an increasing demand to reduce the time and cost required for manufacturing LFAs. The current study introduces an equipment-free method of salt-mediated immobilization of nucleic acids (SAIoNs) for LFAs. Compared to general DNA immobilization methods such as streptavidin-biotin, UV-irradiation, and heat treatment, our method does not require special equipment (e.g., centrifuge, UV-crosslinker, heating device); therefore, it can be applied in a resource-limited environment with reduced production costs. The immobilization process was streamlined and completed within 30 min. Our method improved the color intensity signal approximately 14 times compared to the method without using SAIoNs and exhibited reproducibility with the long-term storage stability. The proposed method can be used to detect practical targets (e.g., SARS-CoV-2) and facilitates highly sensitive and selective detection of target nucleic acids with multiplexing capability and without any cross-reactivity. This novel immobilization strategy provides a basis for easily and inexpensively developing nucleic acid LFAs combined with various types of nucleic acid amplification.

4.
Eur J Radiol Open ; 9: 100452, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36420119

RESUMEN

Objective: To prospectively evaluate the image quality and diagnostic performance of a compact flat-panel detector (FD) scanner for thoracic diseases compared to a clinical CT scanner. Materials and methods: The institutional review board approved this single-center prospective study, and all participants provided informed consent. From December 2020 to May 2021, 30 patients (mean age, 67.1 ± 8.3 years) underwent two same-day low-dose chest CT scans using clinical state-of-art and compact FDCT scanners. Image quality was assessed visually and quantitatively. Two readers evaluated the diagnostic performance for nodules, parenchymal opacifications, bronchiectasis, linear opacities, and pleural abnormalities in 40 paired CT scans. The other 20 paired CT scans were used to examine the agreement of semi-quantitative CT scoring regarding bronchiectasis, bronchiolitis, nodules, airspace consolidations, and cavities. Results: FDCT images had significantly lower visual image quality than clinical CT images (all p < 0.001). The two CT image sets showed no significant differences in signal-to-noise and contrast-to-noise ratios (56.8 ± 12.5 vs. 57.3 ± 15.2; p = 0.985 and 62.9 ± 11.7 vs. 60.7 ± 16.9; p = 0.615). The pooled sensitivity was comparable for nodules, parenchymal opacifications, linear opacities, and pleural abnormalities (p = 0.065-0.625), whereas the sensitivity was significantly lower in FDCT images than in clinical CT images for micronodules (p = 0.007) and bronchiectasis (p = 0.004). The specificity was mostly 1.0. Semi-quantitative CT scores were similar between the CT image sets (p > 0.05), and intraclass correlation coefficients were around 0.950 or higher, except for bronchiectasis (0.869). Conclusion: Compact FDCT images provided lower image quality but comparable diagnostic performance to clinical CT images for nodules, parenchymal opacifications, linear opacities, and pleural abnormalities.

5.
JHEP Rep ; 4(10): 100533, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36052221

RESUMEN

Background & Aims: Strategies to implement HBV screening and treatment are critical to achieve HBV elimination but have been inadequately evaluated in sub-Saharan Africa (sSA). Methods: We assessed the feasibility of screen-and-treat interventions in 3 real-world settings (community, workplace, and hospital) in Senegal. Adult participants were screened using a rapid HBsAg point-of-care test. The proportion linked to care, the proportion who had complete clinical staging (alanine transaminase [ALT], viral load, and FibroScan®), and the proportion eligible for treatment were compared among the 3 intervention groups. Results: In 2013-2016, a total of 3,665 individuals were screened for HBsAg in the community (n = 2,153) and in workplaces (n = 1,512); 199/2,153 (9.2%) and 167/1,512 (11%) were HBsAg-positive in the community and workplaces, respectively. In the hospital setting (outpatient clinics), 638 HBsAg-positive participants were enrolled in the study. All infected participants were treatment naïve. Linkage to care was similar among community-based (69.9%), workplace-based (69.5%), and hospital-based interventions (72.6%, p = 0.617). Of HBV-infected participants successfully linked to care, full clinical staging was obtained in 47.5% (66/139), 59.5% (69/116), and 71.1% (329/463) from the community, workplaces, and hospitals, respectively (p <0.001). The proportion eligible for treatment (EASL criteria) differed among community- (9.1%), workplace- (30.4%), and hospital-based settings (17.6%, p = 0.007). Acceptability of antiviral therapy, adherence, and safety at 1 year were very good. Conclusions: HBV screen-and-treat interventions are feasible in non-hospital and hospital settings in Senegal. However, the continuum of care is suboptimal owing to limited access to full clinical staging. Improvement in access to diagnostic services is urgently needed in sSA. Lay summary: Hepatitis B infection is highly endemic in Senegal. Screening for infection can be done outside hospitals, in communities or workplaces. However, the hepatitis B continuum of care is suboptimal in Senegal and needs to be simplified to scale-up diagnosis and treatment coverage.

6.
Mayo Clin Proc Innov Qual Outcomes ; 6(5): 484-487, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35966031

RESUMEN

Although corticosteroid therapy is the standard of care for all patients hospitalized with severe coronavirus disease 2019 (COVID-19), the studies demonstrating the mortality-benefit ratio of corticosteroids were limited to fully evaluate their adverse effects. To determine the severity of corticosteroid-induced hyperglycemia in patients with and without diabetes mellitus, we retrospectively collected data from the medical records of patients hospitalized with COVID-19 before and after corticosteroids were the standard of care. Corticosteroid-induced hyperglycemia was more severe in patients hospitalized with COVID-19 with diabetes than those without diabetes. Additionally, patients with diabetes required higher doses of correctional insulin per day when on corticosteroid therapy, suggesting that intensive point-of-care glucose monitoring could be limited in patients without diabetes mellitus and support cautionary use of corticosteroids in patients with COVID-19 discharged with supplemental oxygen.

8.
Explor Res Clin Soc Pharm ; 6: 100147, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35733607

RESUMEN

Background: Explicit consideration of implementation factors in community pharmacy service development may facilitate widespread implementation and sustainability. Objectives: This study involved mapping the methodology for the pilot study of point-of-care C-reactive protein (CRP) testing to support pharmacists' management of respiratory tract infections in Western Australian pharmacies against an implementation factor framework, focussing on the resources and training program provided to participating pharmacy staff. Methods: Phase 1 involved post hoc mapping of the pilot study methodology against the framework previously described by Garcia-Cardenas et al.; phase 2 was an a priori evaluation of the resources and training program, involving pre-training, post-training, and post-pilot questionnaires administered to pharmacists and pharmacy assistants/interns. A mixed model analysis compared pharmacists' responses at the three time points. Results: Employment of comprehensive strategies to optimise service feasibility and sustainability was demonstrated across the five domains of 'professional service', 'pharmacy staff', 'pharmacy', 'local environment' and 'system'; further consideration of 'consumer' or 'patient' factors is needed to address issues such as patient refusal. Study pharmacists (n = 10) and pharmacy assistants/interns (n = 5) reported high levels of satisfaction with the training (100% 'good'/'excellent'). Pharmacists reported significantly improved attitudes towards, confidence in, and knowledge about CRP testing and service provision from pre- to post-training (p < 0.05). Positive perceptions were maintained at the post-pilot time point. Conclusions: Post hoc mapping of implementation factors highlighted potential strengths and deficiencies of the current service model. Systematic, prospective mapping, coupled with strategies to explicitly emphasise the patient perspective, may have value in optimising service implementation or modifying future service delivery models.

9.
Sens Actuators B Chem ; 362: 131764, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35370362

RESUMEN

The pandemic of the novel coronavirus disease 2019 (COVID-19) is continuously causing hazards for the world. Effective detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can relieve the impact, but various toxic chemicals are also released into the environment. Fluorescence sensors offer a facile analytical strategy. During fluorescence sensing, biological samples such as tissues and body fluids have autofluorescence, giving false-positive/negative results because of the interferences. Fluorescence near-infrared (NIR) nanosensors can be designed from low-toxic materials with insignificant background signals. Although this research is still in its infancy, further developments in this field have the potential for sustainable detection of SARS-CoV-2. Herein, we summarize the reported NIR fluorescent nanosensors with the potential to detect SARS-CoV-2. The green synthesis of NIR fluorescent nanomaterials, environmentally compatible sensing strategies, and possible methods to reduce the testing frequencies are discussed. Further optimization strategies for developing NIR fluorescent nanosensors to facilitate greener diagnostics of SARS-CoV-2 for pandemic control are proposed.

10.
EClinicalMedicine ; 45: 101308, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35224472

RESUMEN

BACKGROUND: The current SARS-CoV-2 pandemic created an urgent need for rapid, infection screening applied to large numbers of asymptomatic individuals. To date, nasal/throat swab polymerase chain reaction (PCR) is considered the "gold standard". However, this is inconducive to mass, point-of-care (POC) testing due to person discomfort during sampling and a prolonged result turnaround. Breath testing for disease specific organic compounds potentially offers a practical, rapid, non-invasive, POC solution. The study compares the Breath of Health, Ltd. (BOH) breath analysis system to PCR's ability to screen asymptomatic individuals for SARS-CoV-2 infection. The BOH system is mobile and combines Fourier-transform infrared (FTIR) spectroscopy with artificial intelligence (AI) to generate results within 2 min and 15 s. In contrast to prior SARS-CoV-2 breath analysis research, this study focuses on diagnosing SARS-CoV-2 via disease specific spectrometric profiles rather than through identifying the disease specific molecules. METHODS: Asymptomatic emergency room patients with suspected SARS-CoV-2 exposure in two leading Israeli hospitals were selected between February through April 2021. All were tested via nasal/throat-swab PCR and BOH breath analysis. In total, 297 patients were sampled (mean age 57·08 ± SD 18·86, 156 males, 139 females, 2 unknowns). Of these, 96 were PCR-positive (44 males, 50 females, 2 unknowns), 201 were PCR-negative (112 males, 89 females). One hundred samples were used for AI identification of SARS-CoV-2 distinguishing spectroscopic wave-number patterns and diagnostic algorithm creation. Algorithm validation was tested in 100 proof-of-concept samples (34 PCR-positive, 66 PCR-negative) by comparing PCR with AI algorithm-based breath-test results determined by a blinded medical expert. One hundred additional samples (12 true PCR-positive, 85 true PCR-negative, 3 confounder false PCR-positive [not included in the 297 total samples]) were evaluated by two blinded medical experts for further algorithm validation and inter-expert correlation. FINDINGS: The BOH system identified three distinguishing wave numbers for SARS-CoV-2 infection. In the first phase, the single expert identified the first 100 samples correctly, yielding a 1:1 FTIR/AI:PCR correlation. The two-expert second-phase also yielded 1:1 FTIR/AI:PCR correlation for 97 non-confounders and null correlation for the 3 confounders. Inter-expert correlation was 1:1 for all results. In total, the FTIR/AI algorithm demonstrated 100% sensitivity and specificity for SARS-CoV-2 detection when compared with PCR. INTERPRETATION: The SARS-CoV-2 method of breath analysis via FTIR with AI-based algorithm demonstrated high PCR correlation in screening for asymptomatic individuals. This is the first practical, rapid, POC breath analysis solution with such high PCR correlation in asymptomatic individuals. Further validation is required with a larger sample size. FUNDING: Breath of Health Ltd, Rehovot, Israel provided study funding.

11.
Resusc Plus ; 9: 100204, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35141573

RESUMEN

OBJECTIVES: Hyperglycemia is associated with poor outcomes in critically-ill patients. This has implications for prognostication of patients with out-of-hospital cardiac arrest (OHCA) and for post-resuscitation care. We assessed the association of hyperglycemia, on field point-of-care (POC) testing, with survival and neurologic outcome in patients with return of spontaneous circulation (ROSC) after OHCA. METHODS: This was a retrospective analysis of data in a regional cardiac care system from April 2011 through December 2017 of adult patients with OHCA and ROSC who had a field POC glucose. Patients were excluded if they were hypoglycemic (glucose <60 mg/dl) or received empiric dextrose. We compared hyperglycemic (glucose >250 mg/dL) with euglycemic (glucose 60-250 mg/dL) patients. Primary outcome was survival to hospital discharge (SHD). Secondary outcome was survival with good neurologic outcome (cerebral performance category 1 or 2 at discharge). We determined the adjusted odds ratios (AORs) for SHD and survival with good neurologic outcome. RESULTS: Of 9008 patients with OHCA and ROSC, 6995 patients were included; 1941 (28%) were hyperglycemic and 5054 (72%) were euglycemic. Hyperglycemic patients were more likely to be female, of non-White race, and have an initial non-shockable rhythm compared to euglycemic patients (p < 0.0001 for all). Hyperglycemic patients were less likely to have SHD compared to euglycemic survivors, 24.4% vs 32.9%, risk difference (RD) -8.5% (95 %CI -10.8%, -6.2%), p < 0.0001. Hyperglycemic survivors were also less likely to have good neurologic outcome compared to euglycemic survivors, 57.0% vs 64.6%, RD -7.6% (95 %CI -12.9%, -2.4%), p = 0.004. The AOR for SHD was 0.72 (95 %CI 0.62, 0.85), p < 0.0001 and for good neurologic outcome, 0.70 (95 %CI 0.57, 0.86), p = 0.0005. CONCLUSION: In patients with OHCA, hyperglycemia on field POC glucose was associated with lower survival and worse neurologic outcome.

12.
Sensors (Basel) ; 22(4)2022 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-35214519

RESUMEN

The early diagnosis of infectious diseases is critical because it can greatly increase recovery rates and prevent the spread of diseases such as COVID-19; however, in many areas with insufficient medical facilities, the timely detection of diseases is challenging. Conventional medical testing methods require specialized laboratory equipment and well-trained operators, limiting the applicability of these tests. Microfluidic point-of-care (POC) equipment can rapidly detect diseases at low cost. This technology could be used to detect diseases in underdeveloped areas to reduce the effects of disease and improve quality of life in these areas. This review details microfluidic POC equipment and its applications. First, the concept of microfluidic POC devices is discussed. We then describe applications of microfluidic POC devices for infectious diseases, cardiovascular diseases, tumors (cancer), and chronic diseases, and discuss the future incorporation of microfluidic POC devices into applications such as wearable devices and telemedicine. Finally, the review concludes by analyzing the present state of the microfluidic field, and suggestions are made. This review is intended to call attention to the status of disease treatment in underdeveloped areas and to encourage the researchers of microfluidics to develop standards for these devices.


Asunto(s)
COVID-19 , Sistemas de Atención de Punto , COVID-19/diagnóstico , Humanos , Dispositivos Laboratorio en un Chip , Microfluídica , Calidad de Vida , SARS-CoV-2
13.
Chem Eng Sci ; 251: 117430, 2022 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-35043022

RESUMEN

Loop-mediated isothermal amplification (LAMP) is widely used in detection of pathogenic microorganisms including SARS-CoV-2. However, the performance of LAMP assay needs further exploration in the emerging SARS-CoV-2 variants test. Here, we design serials of primers and select an optimal set for LAMP-based on SARS-CoV-2 N gene for a robust and visual assay in SARS-CoV-2 diagnosis. The limit of detectable template reaches 10 copies of N gene per 25 µL reaction at isothermal 58℃ within 40 min. Importantly, the primers for LAMP assay locate at 12 to 213 nt of N gene, a highly conservative region, which serves as a compatible test in emerging SARS-CoV-2 variants. Comparison to a commercial qPCR assay, this LAMP assay exerts the high viability in diagnosis of 41 clinical samples. Our study optimizes an advantageous LAMP assay for colorimetric detection of SARS-CoV-2 and emerging variants, which is hopeful to be a promising test in COVID-19 surveillance.

14.
Contemp Clin Trials Commun ; 26: 100889, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36684692

RESUMEN

Point-of-care (POC) Testing (POCT) is a medical diagnostic approach carried out outside the clinical laboratory and close to the patient. The results are used for the immediate clinical decision to improve patient care. Accreditation Canada and Diagnostic Accreditation Programs regulatory standards and the College of the American Pathologists for POCT have implemented several guidelines and certifications. POC in heart failure (POC-HF) will demonstrate that it is helpful to develop a preliminary understanding of the value of serial N-terminal pro-B-type natriuretic peptide (NT-proBNP) measurements in the diagnostic and therapeutic process in patients hospitalized with acute decompensation of heart failure. In addition, POC-HF will hopefully answer questions on the workability of this approach in clinical routine and the usefulness and justification to perform larger-scale studies investigating this strategy.

15.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-961132

RESUMEN

Background@#The search for simple clinical and laboratory markers to help predict the clinical severity of patients presenting with COVID-19 has prompted this study to look at the predictive value of urine L-FABP (Liver Type-Fatty Acid Binding Protein) point-of-care test kit at the initial presentation of COVID-19 patients to the hospital.@*Methods@#The validation study prospectively included 109 consecutive patients with mild to moderate COVID-19, mean age of 52.2 years (range 19-84) presenting at the Emergency Rooms of 4 participating Metro-Manila hospitals from February to April 2021, with available data for analysis for 103 patients. Urine L-FABP POC (Point-of-Care) test and other clinical parameters and the level of severity of COVID-19 were determined at Day 0, Day 4 and Day 7. Computations for Sensitivity, Specificity, Positive and Negative Predictive values and Likelihood ratios were performed.@*Results@#Twenty-three patients tested positive for urine L-FABP, out of the 103 patients analyzed, while 80 tested negative. Of the 23 patients who tested positive for urine L-FABP, 6 has progressed in severity, while 17 did not progressed. Of the 80 patients who tested negative for urine L-FABP, 13 progressed, while 67 did not progressed in severity. Giving a Sensitivity of 31.58%, Specificity of 79.76%, Positive predictive value of 26.09%, Negative predictive value of 83.75%. Combining urine L-FABP and initial clinical parameters like SIRS (Systemic Inflammatory Response Syndrome) criteria to predict progression of severity yielded a higher Specificity of 91.67 % and Negative Predictive value of 84.62%.@*Conclusions@#The study shows the utility of initial urine L-FABP POC test as a negative screening test in triaging adult patients presenting to the ER with mild to moderate COVID-19. Patients at the ER with a negative urine L-FABP test, will most likely not progressed to severe COVID-19. Combining clinical parameters like SIRS Criteria with the urine L-FABP result can increase the negative predictive value.


Asunto(s)
COVID-19
16.
Front Cell Infect Microbiol ; 11: 681063, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34222049

RESUMEN

Malaria is a serious public health problem that affects mostly the poorest countries in the world, killing more than 400,000 people per year, mainly children under 5 years old. Among the control and prevention strategies, the differential diagnosis of the Plasmodium-infecting species is an important factor for selecting a treatment and, consequently, for preventing the spread of the disease. One of the main difficulties for the detection of a specific Plasmodium sp is that most of the existing methods for malaria diagnosis focus on detecting P. falciparum. Thus, in many cases, the diagnostic methods neglect the other non-falciparum species and underestimate their prevalence and severity. Traditional methods for diagnosing malaria may present low specificity or sensitivity to non-falciparum spp. Therefore, there is high demand for new alternative methods able to differentiate Plasmodium species in a faster, cheaper and easier manner to execute. This review details the classical procedures and new perspectives of diagnostic methods for malaria non-falciparum differential detection and the possibilities of their application in different circumstances.


Asunto(s)
Malaria Falciparum , Malaria , Plasmodium , Niño , Preescolar , Humanos , Malaria/diagnóstico , Plasmodium falciparum , Prevalencia , Sensibilidad y Especificidad
17.
AACE Clin Case Rep ; 7(4): 239-242, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34307844

RESUMEN

OBJECTIVE: To create awareness among health care professionals and nurses regarding interference with point-of-care (POC) blood glucose (BG) meter by high-dose intravenous vitamin C and other potential substances. We report a case that probably resulted in the death of a patient from an erroneous interpretation of POC-BG readings due to interference from high-dose vitamin C. METHODS: Retrospective case review. RESULTS: Our patient was admitted following a syncopal episode associated with an acute non-ST elevation myocardial infarction. She was found to have significant hyperglycemia with blood glucose >600 mg/dL on POC testing, associated with moderate ketoacidosis. She was treated with intravenous insulin as a case of diabetic ketoacidosis (DKA). She developed severe hypoglycemia, which was confirmed on a venous BG, and her condition was complicated by an apparent stroke-like state. The patient deteriorated and subsequently died. We found no report of vitamin C causing apparent DKA, as seen in our case. CONCLUSION: POC-BG monitoring is very commonly used in intensive care unit settings to monitor BG as they are minimally invasive, convenient, and quick. However, physicians and nurses need to be aware that certain substances can interfere with and alter POC-BG levels, leading to incorrect diagnosis of pseudohyperglycemia or pseudohypoglycemia. This may potentially lead to catastrophic consequences and result in increased morbidity and mortality in intensive care unit settings. The Food and Drug Administration advises against the use of POC-BG meters in critical settings, and they should never be used to diagnose DKA.

18.
Acta Pharm Sin B ; 11(8): 2344-2361, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34150486

RESUMEN

Recent infectious disease outbreaks, such as COVID-19 and Ebola, have highlighted the need for rapid and accurate diagnosis to initiate treatment and curb transmission. Successful diagnostic strategies critically depend on the efficiency of biological sampling and timely analysis. However, current diagnostic techniques are invasive/intrusive and present a severe bottleneck by requiring specialist equipment and trained personnel. Moreover, centralised test facilities are poorly accessible and the requirement to travel may increase disease transmission. Self-administrable, point-of-care (PoC) microneedle diagnostic devices could provide a viable solution to these problems. These miniature needle arrays can detect biomarkers in/from the skin in a minimally invasive manner to provide (near-) real-time diagnosis. Few microneedle devices have been developed specifically for infectious disease diagnosis, though similar technologies are well established in other fields and generally adaptable for infectious disease diagnosis. These include microneedles for biofluid extraction, microneedle sensors and analyte-capturing microneedles, or combinations thereof. Analyte sampling/detection from both blood and dermal interstitial fluid is possible. These technologies are in their early stages of development for infectious disease diagnostics, and there is a vast scope for further development. In this review, we discuss the utility and future outlook of these microneedle technologies in infectious disease diagnosis.

19.
Microchem J ; 167: 106305, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33897053

RESUMEN

Since December 2019, we have been in the battlefield with a new threat to the humanity known as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). In this review, we describe the four main methods used for diagnosis, screening and/or surveillance of SARS-CoV-2: Real-time reverse transcription polymerase chain reaction (RT-PCR); chest computed tomography (CT); and different complementary alternatives developed in order to obtain rapid results, antigen and antibody detection. All of them compare the highlighting advantages and disadvantages from an analytical point of view. The gold standard method in terms of sensitivity and specificity is the RT-PCR. The different modifications propose to make it more rapid and applicable at point of care (POC) are also presented and discussed. CT images are limited to central hospitals. However, being combined with RT-PCR is the most robust and accurate way to confirm COVID-19 infection. Antibody tests, although unable to provide reliable results on the status of the infection, are suitable for carrying out maximum screening of the population in order to know the immune capacity. More recently, antigen tests, less sensitive than RT-PCR, have been authorized to determine in a quicker way whether the patient is infected at the time of analysis and without the need of specific instruments.

20.
Sens Actuators B Chem ; 329: 129214, 2021 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-36568647

RESUMEN

This review reports the recent advances in surface-enhanced Raman scattering (SERS)-based lateral flow assay (LFA) platforms for the diagnosis of infectious diseases. As observed through the recent infection outbreaks of COVID-19 worldwide, a timely diagnosis of the disease is critical for preventing the spread of a disease and to ensure epidemic preparedness. In this regard, an innovative point-of-care diagnostic method is essential. Recently, SERS-based assay platforms have received increasing attention in medical communities owing to their high sensitivity and multiplex detection capability. In contrast, LFAs provide a user-friendly and easily accessible sensing platform. Thus, the combination of LFAs with a SERS detection system provides a new diagnostic modality for accurate and rapid diagnoses of infectious diseases. In this context, we briefly discuss the recent application of LFA platforms for the POC diagnosis of SARS-CoV-2. Thereafter, we focus on the recent advances in SERS-based LFA platforms for the early diagnosis of infectious diseases and their applicability for the rapid diagnosis of SARS-CoV-2. Finally, the key issues that need to be addressed to accelerate the clinical translation of SERS-based LFA platforms from the research laboratory to the bedside are discussed.

SELECCIÓN DE REFERENCIAS