Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Neurosci ; 17: 1186558, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37404469

RESUMEN

Dynamic oxygen-17 (17O) magnetic resonance imaging (MRI) is an imaging method that enables a direct and non-invasive assessment of cerebral oxygen metabolism and thus potentially the distinction between viable and non-viable tissue employing a three-phase inhalation experiment. The purpose of this investigation was the first application of dynamic 17O MRI at 7 Tesla (T) in a patient with stroke. In this proof-of-concept experiment, dynamic 17O MRI was applied during 17O inhalation in a patient with early subacute stroke. The analysis of the relative 17O water (H217O) signal for the affected stroke region compared to the healthy contralateral side revealed no significant difference. However, the technical feasibility of 17O MRI has been demonstrated paving the way for future investigations in neurovascular diseases.

2.
Magn Reson Med ; 85(6): 3112-3124, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33368649

RESUMEN

PURPOSE: The aim of this study was to develop a high-resolution 3D oxygen-17 (17 O) MRI method to delineate the kinetics of 17 O-enriched water (H217 O) across the entire mouse brain after a bolus injection via the tail vein. METHODS: The dynamic 17 O signal was acquired with a golden-means-based 3D radial sampling scheme. To achieve adequate temporal resolution with preserved spatial resolution, a k-space-weighted view sharing strategy was used in image reconstruction with an adaptive window size tailored to the kinetics of the 17 O signal. Simulation studies were performed to determine the adequate image reconstruction parameters. The established method was applied to delineating the kinetics of intravenously injected H217 O in vivo in the post-stroke mouse brain. RESULTS: The proposed dynamic 17 O-MRI method achieved an isotropic resolution of 1.21 mm (0.77 mm nominal) in mouse brain at 9.4T, with the temporal resolution increased gradually from 3 s at the initial phase of rapid signal increase to 15 s at the steady-state. The high spatial resolution enabled the delineation of the heterogeneous H217 O uptake and washout kinetics in stroke-affected mouse brain. CONCLUSION: The current study demonstrated a 3D 17 O-MRI method for dynamic monitoring of 17 O signal changes with high spatial and temporal resolution. The method can be utilized to quantify physiological parameters such as cerebral blood flow and blood-brain barrier permeability by tracking injected H217 O. It can also be used to measure oxygen consumption rate in 17 O-oxygen inhalation studies.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Animales , Aumento de la Imagen , Imagen por Resonancia Magnética , Ratones , Isótopos de Oxígeno
3.
Magn Reson Med ; 79(1): 256-263, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28295552

RESUMEN

PURPOSE: The current study aimed to develop a three-dimensional (3D) dynamic oxygen-17 (17 O) MR imaging method with high temporal and spatial resolution to delineate the kinetics of 17 O water uptake and washout in the brains of mice with glioblastoma (GBM). METHODS: A 3D imaging method with a stack-of-stars golden-ratio-based radial sampling scheme was employed to acquire 17 O signal in vivo. A k-space-weighted image reconstruction method was used to improve the temporal resolution while preserving spatial resolution. Simulation studies were performed to validate the method. Using this method, the kinetics of 17 O water uptake and washout in the brains of mice with GBM were delineated after an intravenous bolus injection of 17 O water. RESULTS: The proposed 17 O imaging method achieved an effective temporal resolution of 7.56 s with a nominal voxel size of 5.625 µL in the mouse brain at 9.4 T. Reduced uptake and prolonged washout of 17 O water were observed in tumor tissue, suggesting compromised cerebral perfusion. CONCLUSION: This study demonstrated a promising dynamic 17 O imaging approach that can delineate 17 O water kinetics in vivo with high temporal and spatial resolution. It can also be used to image cerebral oxygen consumption rate in oxygen-17 inhalation studies. Magn Reson Med 79:256-263, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Glioblastoma/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador , Isótopos de Oxígeno/química , Agua/química , Algoritmos , Animales , Simulación por Computador , Medios de Contraste , Aumento de la Imagen , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Cinética , Imagen por Resonancia Magnética , Masculino , Ratones , Ratones Desnudos , Fantasmas de Imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA