Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 16.812
Filtrer
1.
Small ; : e2402067, 2024 Aug 02.
Article de Anglais | MEDLINE | ID: mdl-39092685

RÉSUMÉ

Additive manufacturing (AM) will empower the next breakthroughs in nanotechnology by combining unmatched geometrical freedom with nanometric resolution. Despite recent advances, no micro-AM technique has been able to synthesize functional nanostructures with excellent metal quality and sub-100 nm resolution. Here, significant breakthroughs in electrohydrodynamic redox 3D printing (EHD-RP) are reported by directly fabricating high-purity Cu (>98 at.%) with adjustable voxel size from >6µm down to 50 nm. This unique tunability of the feature size is achieved by managing in-flight solvent evaporation of the ion-loaded droplet to either trigger or prevent the Coulomb explosion. In the first case, the landing of confined droplets on the substrate allows the fabrication of high-aspect-ratio 50 nm-wide nanopillars, while in the second, droplet disintegration leads to large-area spray deposition. It is discussed that the reported pillar width corresponds to the ultimate resolution achievable by EHD printing. The unrivaled feature size and growth rate (>100 voxel s-1) enable the direct manufacturing of 30 µm-tall atom probe tomography (APT) tips that unveil the pristine microstructure and chemistry of the deposit. This method opens up prospects for the development of novel materials for 3D nano-printing.

2.
Technol Health Care ; 2024 Jul 15.
Article de Anglais | MEDLINE | ID: mdl-39093089

RÉSUMÉ

BACKGROUND: Current treatments do not support direct exposure of fracture fragments, resulting in the inability to directly observe the articular surface during surgery for accurate reduction and firm fixation. OBJECTIVE: The aim of the study was to explore the treatment effect of digital virtual reduction combined with individualized guide plate of lateral tibial condyle osteotomy on tibial plateau fracture involving the lateral posterior condyle collapse. METHODS: 41 patients with tibial plateau fracture involving the lateral posterior condyle collapse were recruited in the trial. All patients underwent Computed Tomography (CT) scanning before operation. After operation, fracture reduction was evaluated using Rasmussen score and function of knee joint was assessed using hospital for special surgery (HSS) score. RESULTS: 41 patients were followed-up 6-26 months (mean, 15.2 months). Fracture reduction was good after operation, with an average of 13.3 weeks of fracture healing without serious complications. The excellent and good rate was 97.6%. The joint movement degree was -5∘∼0∘∼135∘ with an average of 125.5∘. CONCLUSIONS: Digital virtual reduction combined with individualized guide plate of lateral tibial condyle osteotomy was effectively for treating tibial plateau fracture involving the lateral posterior condyle collapse.

3.
Acta Biomater ; 2024 Jul 30.
Article de Anglais | MEDLINE | ID: mdl-39089351

RÉSUMÉ

Scaffolds for bone defect treatment should ideally support vascularization and promote bone formation, to facilitate the translation into biomedical device applications. This study presents a novel approach utilizing 3D-printed water-dissolvable polyvinyl alcohol (PVA) sacrificial molds to engineer polymerized High Internal Phase Emulsion (polyHIPE) scaffolds with microchannels and distinct multiscale porosity. Two sacrificial mold variants (250 µm and 500 µm) were generated using fused deposition modeling, filled with HIPE, and subsequently dissolved to create polyHIPE scaffolds containing microchannels. In vitro assessments demonstrated significant enhancement in cell infiltration, proliferation, and osteogenic differentiation, underscoring the favorable impact of microchannels on cell behavior. High loading efficiency and controlled release of the osteogenic factor BMP-2 were achieved, with microchannels facilitating release of the growth factor. Evaluation in a mouse critical-size calvarial defect model revealed enhanced vascularization and bone formation in microchanneled scaffolds containing BMP-2. This study not only introduces an accessible method for creating multiscale porosity in polyHIPE scaffolds but also emphasizes its capability to enhance cellular infiltration, controlled growth factor release, and in vivo performance. The findings suggest promising applications in bone tissue engineering and regenerative medicine, and are expected to facilitate the translation of this type of biomaterial scaffold. STATEMENT OF SIGNIFICANCE: This study holds significance in the realm of biomaterial scaffold design for bone tissue engineering and regeneration. We demonstrate a novel method to introduce controlled multiscale porosity and microchannels into polyHIPE scaffolds, by utilizing 3D-printed water-dissolvable PVA molds. The strategy offers new possibilities for improving cellular infiltration, achieving controlled release of growth factors, and enhancing vascularization and bone formation outcomes. This microchannel approach not only marks a substantial stride in scaffold design but also demonstrates its tangible impact on enhancing osteogenic cell differentiation and fostering robust bone formation in vivo. The findings emphasize the potential of this methodology for bone regeneration applications, showcasing an interesting advancement in the quest for effective and innovative biomaterial scaffolds to regenerate bone defects.

4.
Emerg Med Australas ; 2024 Aug 01.
Article de Anglais | MEDLINE | ID: mdl-39091126

RÉSUMÉ

OBJECTIVE: Intra-articular injection of local anaesthetic provides safe and effective analgesia for patients with shoulder dislocation. We designed a three-dimensional-printed ultrasound model of the shoulder to educate ED clinicians on use of this technique. We aimed to evaluate the impact of a 1-h training session using this model on participants' knowledge, skills and clinical practice. METHODS: This was a prospective study of the clinicians working at two EDs in New Zealand. Participants (n = 20) took part in a 1-h educational session. We tested participants' performance before the session, afterwards and at 3 months using a 10-point objective structured clinical examination. We reviewed clinical records to determine whether there was increased utilisation of this technique among ED patients before and after the training. RESULTS: There was improvement in participants' OCSE performance (median pre-training score = 4.00, median 3-month post-training score = 7.00, P = 0.044) and self-reported competence and knowledge, which were sustained to the end of the study. There was increased use of intra-articular injection among ED patients with shoulder dislocation: 2 of 68 patients (3%) before and 11 of 76 patients (14.5%) after the study. Notably, most were performed by clinicians who did not take part in the study (n = 9). CONCLUSION: A 1-h training session using a three-dimensional-printed model improved participants objective structured clinical examination performance in ultrasound-guided injection of the shoulder joint. Although there was minimal change in the practice of participating clinicians, overall use of the procedure increased.

5.
Article de Anglais | MEDLINE | ID: mdl-39086207

RÉSUMÉ

A lack of sustainability in the design of electronic components contributes to the current challenges of electronic waste and material sourcing. Common materials for electronics are prone to environmental, economic, and ethical problems in their sourcing, and at the end of their life often contribute to toxic and nonrecyclable waste. This study investigates the inkjet printing of flexible humidity sensors and includes biosourced and biodegradable materials to improve the sustainability of the process. Humidity sensors are useful tools for monitoring atmospheric conditions in various fields. Here, an aqueous dispersion of black soldier fly melanin was optimized for printing with a cosolvent and deposited onto interdigitated silver electrodes on flexible substrates. Impedance spectroscopy demonstrated that adding choline chloride increased the ion concentration and AC conductivity by more than 3 orders of magnitude, resulting in a significant improvement in sensing performance and reduced hysteresis. The devices exhibit fast detection (0.8 ± 0.5 s) and recovery times (0.8 ± 0.3 s), with a 170 ± 40-fold decrease in impedance for relative humidity changes from 30% to 90%. This factor is lowered upon prolonged exposure to high humidity in tests over 72 h during which a stable operation is reached. The low embodied energy of the sensor, achieved through material-efficient deposition and the use of waste management byproducts, enhances its sustainability. In addition, approaches for reusability and degradability are presented, rendering the sensor suitable for wearable or agricultural applications.

6.
Small ; : e2403525, 2024 Aug 01.
Article de Anglais | MEDLINE | ID: mdl-39087369

RÉSUMÉ

Living organisms in nature possess diverse and vibrant structural colors generated from their intrinsic surface micro/nanostructures. These intricate micro/nanostructures can be harnessed to develop a new generation of colorful materials for various fields such as photonics, information storage, display, and sensing. Recent advancements in the fabrication of photonic crystals have enabled the preparation of structurally colored materials with customized geometries using 3D printing technologies. Here, a comprehensive review of the historical development of fabrication methods for photonic crystals is provided. Diverse 3D printing approaches along with the underlying mechanisms, as well as the regulation methods adopted to generate photonic crystals with structural color, are discussed. This review aims to offer the readers an overview of the state-of-the-art 3D printing techniques for photonic crystals, present a guide and considerations to fabricate photonic crystals leveraging different 3D printing methods.

7.
Cureus ; 16(7): e63680, 2024 Jul.
Article de Anglais | MEDLINE | ID: mdl-39092373

RÉSUMÉ

Early loss of deciduous teeth is a challenging situation to handle. In recent years, the loss of deciduous teeth has become very frequent because of the increased risk of caries. Space maintainers play a vital role in preventing space loss. Lingual arch space maintainers are effectively used to maintain space in the lower arch. In order to retain the length of the lower arch and to prevent mesial migration of the mandibular first permanent molar, lingual arch space maintainers are often indicated. Conventional lingual arch fabrication is technique-sensitive and cumbersome. Additionally, it has many documented drawbacks like solder breakage, cement loss, soft tissue lesions, etc. With the advent of newer technology like three-dimensional (3D) printing, the fabrication of appliances and prostheses has become more predictable, accurate, and relatively easier. The present case report highlights the technique and advantages of 3D printing to fabricate lingual arch space maintainers, which has the potential to revolutionize preventive orthodontics in pediatric dentistry.

8.
Article de Anglais | MEDLINE | ID: mdl-39094590

RÉSUMÉ

PURPOSE: Secondary skin collimation (SSC) is essential for shielding normal tissues near tumors during electron and orthovoltage radiation treatments. Traditional SSC fabrication methods, such as crafting in-house lead sheets, are labor-intensive and produce SSCs with low geometric accuracy. This study introduces a workflow that integrated 3D scanning and 3D printing technologies with an in-house mold process, enabling the production of patient-specific SSCs within six hours. Methods: An anthropomorphic head phantom was scanned with a handheld 3D scanner. The resulting scan data was imported into 3D modeling software for design. The completed model was exported to a 3D printer as a printable file. Subsequently, molten Cerrobend was poured into the mold and allowed to set, completing the SSC production. Geometric accuracy was assessed using CT images, and the shielding effectiveness was evaluated through film dosimetry. Results: The 3D printed mold achieved submillimeter accuracy (0.5 mm) and exhibited high conformity to the phantom surface. It successfully endured the weight and heat of the Cerrobend during pouring and curing. Dosimetric analysis conducted with radiochromic film demonstrated good agreement between the measured and expected attenuation values of the SSC slab, within ±3%. Conclusions: This study presents a proof of concept for novel mold room workflows that produce patient-specific SSCs within six hours, a significant improvement over the traditional SSC fabrication process, which takes 2-3 days. The submillimeter accuracy and versatility of 3D scanning and printing technologies afford greater design freedom and enhanced delivery accuracy for cases involving irregular geometries.

9.
Int J Biol Macromol ; : 134402, 2024 Jul 31.
Article de Anglais | MEDLINE | ID: mdl-39094885

RÉSUMÉ

3D printed scaffolds have revolutionized the field of regenerative medicine by overcoming the lacunas such as precision, customization, and reproducibility observed through traditional methods of scaffold preparation such as freeze-drying, electrospinning, etc. Combining the advantages of 3D printed scaffolds along with bioactive cues such as signaling molecules can be an effective treatment approach. In the present study, cellulose nanocrystals (CNCs) along with gelatin, in different ratios, were used for scaffold preparation through the direct ink writing technique and thoroughly characterized. The scaffolds showed porous microstructure, high swelling ratio (~390 to 590), degradability and porosity (~65 %). In vitro biocompatibility assays showed high biocompatibility and no toxicity through live-dead, proliferation and hemolysis assay. Further, the optimum formulation was functionalized with nitric oxide (NO)-releasing modified gelatin to enhance the scaffold's biomedical applicability. Functionality assays with this formulation, scratch, and neurite outgrowth showed positive effects of NO on cell migration and neurite length. The study presents the fabrication, modification, and biomedical applicability of the aforementioned inks, which paves new pathways in the field of 3D printing of scaffolds with significant potential for biomedical applications, soft tissue engineering, and wound dressing, for example.

10.
Int J Pharm ; : 124543, 2024 Jul 31.
Article de Anglais | MEDLINE | ID: mdl-39094921

RÉSUMÉ

Gastrointestinal (GI) environment is influenced by several factors (gender, genetics, sex, disease state, food) leading to oral drug absorption variability or to low bioavailability. In this scenario, gastroretentive drug delivery systems (GRDDS) have been developed in order to solve absorption problems, to lead to a more effective local therapy or to allow sustained drug release during a longer time period than the typical oral sustained release dosage forms. Among all GRDDS, floating systems seem to provide a promising and practical approach for achieving a long intra-gastric residence time and sustained release profile. In the last years, a novel technique is being used to manufacture this kind of systems: three-dimensional (3D) printing technology. This technique provides a versatile and easy process to manufacture personalized drug delivery systems. This work presents a systematic review of the main 3D printing based designs proposed up to date to manufacture floating systems. We have also summarized the most important parameters involved in buoyancy and sustained release of the systems, in order to facilitate the scale up of this technology to industrial level. Finally, a section discussing about the influence of materials in drug release, their biocompatibility and safety considerations have been included.

11.
Dent Mater ; 2024 Aug 02.
Article de Anglais | MEDLINE | ID: mdl-39095245

RÉSUMÉ

OBJECTIVE: To formulate an experimental methacrylate-based photo-polymerizable resin for 3D printing with ytterbium trifluoride as filler and to evaluate the mechanical, physicochemical, and biological properties. METHODS: Resin matrix was formulated with 60 wt% UDMA, 40 wt% TEGDMA, 1 wt% TPO, and 0.01 wt% BHT. Ytterbium Trifluoride was added in concentrations of 1 (G1 %), 2 (G2 %), 3 (G3 %), 4 (G4 %), and 5 (G5 %) wt%. One group remained without filler addition as control (GC). The samples were designed in 3D builder software and printed using a UV-DLP 3D printer. The samples were ultrasonicated with isopropanol and UV cured for 60 min. The resins were tested for degree of conversion (DC), flexural strength, Knoop microhardness, softening in solvent, radiopacity, colorimetric analysis, and cytotoxicity (MTT and SRB). RESULTS: Post-polymerization increased the degree of conversion of all groups (p < 0.05). G2 % showed the highest DC after post-polymerization. G2 % showed no differences in flexural strength from the G1 % and GC (p > 0.05). All groups showed a hardness reduction after solvent immersion. No statistical difference was found in radiopacity, softening in solvent (ΔKHN%), colorimetric spectrophotometry, and cytotoxicity (MTT) (p > 0.05). G1 % showed reduced cell viability for SRB assay (p < 0.05). SIGNIFICANCE: It was possible to produce an experimental photo-polymerizable 3D printable resin with the addition of 2 % ytterbium trifluoride as filler without compromising the mechanical, physicochemical, and biological properties, comparable to the current provisional materials.

12.
Ann Biomed Eng ; 2024 Aug 02.
Article de Anglais | MEDLINE | ID: mdl-39095638

RÉSUMÉ

PURPOSE: Flow diverting stents (FDS) are used to treat cerebral aneurysms, by promoting thrombosis and occlusion of the aneurysm sac. However, retreatment is required in some cases, and the biologic basis behind treatment outcome is not known. The goal of this study was to understand how changes in hemodynamic flow after FDS placement affect aneurysmal endothelial cell (EC) activity. METHODS: Three-dimensional models of patient-specific aneurysms were created to quantify the EC response to FDS placement. Computational fluid dynamic simulations were used to determine the hemodynamic impact of FDS. Two identical models were created for each patient; into one a FDS was inserted. Each model was then populated with human carotid ECs and subjected to patient-specific pulsatile flow for 24 h. ECs were isolated from aneurysm dome from each model and bulk RNA sequencing was performed. RESULTS: Paired untreated and treated models were created for four patients. Aneurysm dome EC analysis revealed 366 (2.6%) significant gene changes between the untreated and FDS conditions, out of 13909 total expressed genes. Gene set enrichment analysis of the untreated models demonstrated enriched gene ontology terms related to cell adhesion, growth/tensile activity, cytoskeletal organization, and calcium ion binding. In the FDS models, enriched terms were related to cellular proliferation, ribosomal activity, RNA splicing, and protein folding. CONCLUSION: Treatment of cerebral aneurysms with FDS induces significant EC gene transcription changes related to aneurysm hemodynamics in patient-specific in vitro 3D-printed models subjected to pulsatile flow. Further investigation is needed into the relationship between transcriptional change and treatment outcome.

13.
Macromol Biosci ; : e2400136, 2024 Aug 03.
Article de Anglais | MEDLINE | ID: mdl-39096155

RÉSUMÉ

The complex anatomy of the cornea and the subsequent keratocyte-fibroblast transition have always made corneal stromal regeneration difficult. Recently, 3D printing has received considerable attention in terms of fabrication of scaffolds with precise dimension and pattern. In the current work, 3D printable polymer hydrogels made of GelMA/agarose are formulated and its rheological properties are evaluated. Despite the variation in agarose content, both the hydrogels exhibited G'>G'' modulus. A prototype for 3D stromal model is created using Solid Works software, mimicking the anatomy of an adult cornea. The fabrication of 3D-printed hydrogels is performed using pneumatic extrusion. The FTIR analysis speculated that the hydrogel is well crosslinked and established strong hydrogen bonding with each other, thus contributing to improved thermal and structural stability. The MTT analysis revealed a higher rate of cell proliferation on the hydrogels. The optical analysis carried out on the 14th day of incubation revealed that the hydrogels exhibit transparency matching with natural corneal stromal tissue. Specific protein marker expression confirmed the keratocyte phenotype and showed that the cells do not undergo terminal differentiation into stromal fibroblasts. The findings of this work point to the potential of GelMA/A hydrogels as a novel biomaterial for corneal stromal tissue engineering.

14.
Forensic Sci Int ; 362: 112183, 2024 Aug 02.
Article de Anglais | MEDLINE | ID: mdl-39096794

RÉSUMÉ

The development of 3D printing technology has brought new risks and challenges to stamp impression identification. To prevent potential risks, a total of 45 stamps were printed using three types of 3D printers: fused deposition molding (FDM) printer, stereo lithography (SLA) printer, and liquid crystal display (LCD)-based SLA 3D printer, including 6 stamps replicated using LCD-based SLA 3D printer. A preliminary study was conducted on the printed stamps and stamped impressions, and the results showed that stamp are influenced by various factors such as printer type, printing material, the technology level of the producer, mold parameters such as font, size, printing parameters, slicing direction, and polishing process, etc., resulting in significant differences in characteristics. However, there are some obviously common characteristics such as missing of strokes, exposure of white and mottled phenomenon in the impression stamped by the 3D produced stamp. The impression of stamp replicated with an LCD 3D printer can be easily identified since it is difficult to achieve consistency with the real impression in detail characteristics.

15.
Int J Biol Macromol ; : 134427, 2024 Aug 01.
Article de Anglais | MEDLINE | ID: mdl-39097050

RÉSUMÉ

Salivary glands are the principal organs responsible for secreting saliva in the oral cavity. Tumors, trauma, inflammation, and other factors can cause functional or structural damage to the glands, leading to reduced saliva secretion. In this study, we innovatively prepared a acinar-mimetic silk fibroin-collagen-astragalus polysaccharide (SCA) scaffold using low-temperature three-dimensional (3D) printing and freeze-drying techniques. We evaluated the material properties and cell compatibility of the scaffold in vitro and implanted it into the damaged parotid glands (PG) of rats to assess its efficacy in tissue reconstruction and functional repair. The results demonstrated that the SCA scaffold featured a porous structure resembling natural acini, providing an environment conducive to cell growth and orderly aggregation. It exhibited excellent porosity, water absorption, mechanical properties, and biocompatibility, fulfilling the requirements for tissue engineering scaffolds. In vitro, the scaffold facilitated adhesion, proliferation, orderly polarization, and spherical aggregation of PG cells. In vivo, the SCA scaffold effectively recruited GECs locally, forming gland-like acinar structures that matured gradually, promoting the regeneration of damaged PGs. The SCA scaffold developed in this study supports tissue reconstruction and functional repair of damaged PGs, making it a promising implant material for salivary gland regeneration.

16.
Foot Ankle Surg ; 2024 Aug 02.
Article de Anglais | MEDLINE | ID: mdl-39097425

RÉSUMÉ

BACKGROUND: Collapse of the talus and peri-talar arthritis pose treatment challenges due to the anatomy and location of the talus as a keystone of the foot and ankle. Custom 3D-printed total talus replacement (TTR) and combined total ankle total talus replacement (TATTR) have emerged as treatment options for these pathologies. However, the safety and efficacy of these implants is unknown due to the limited number of cases and short follow-up durations. METHODS: This was a retrospective study to assess surgical outcomes of patients who underwent a TTR and TATTR with or without subtalar fusion. Patient demographics, intraoperative parameters, device related surgical and non-surgical events, imaging and clinical evaluations, and patient reported outcome (PRO) measures were compiled. RESULTS: A total of 38 patients received a custom 3D-printed implant with mean follow-up time of 22.1 (range: 12-45) months. In this cohort, 7 (18.4 %) required secondary surgery and 3 (7.9 %) required implant removal. Multivariate logistic regression revealed that patient diagnosis of depression was a significant predictor of secondary surgery with an OR 17.50 (p = 0.037). Significant postoperative improvements were observed in the talocalcaneal height (p = 0.005) and talar declination angle (p = 0.013) for the TATTR group. VAS and PROMIS pain interference (PI) scores demonstrated an initial significant improvement in pain, but this improvement did not maintain significance at most recent follow-up. However, there was a significant increase in the PROMIS physical function (PF) scores (p = 0.037) at most recent follow-up. CONCLUSION: These results demonstrate that TTR and TATTR provide significant improvement in post-operative radiographic foot and ankle alignment and physical function at the two-year timepoint. PRO findings suggest that patients are more active after surgery. Surgeons considering proceeding with either of these procedures should counsel patients about pain and functional outcomes as well as realistic expectations in patients with depression. LEVEL OF EVIDENCE: Level 3.

17.
J Cardiothorac Surg ; 19(1): 431, 2024 Jul 10.
Article de Anglais | MEDLINE | ID: mdl-38987804

RÉSUMÉ

Closed chest drainage is typically necessary following Lobar and Sublobar resections to evacuate gases and fluids from the thoracic cavity, eliminate residual pleural space for lung expansion, and maintain negative pressure. Currently, three conventional closed chest drainage systems are commonly employed: single-chamber, double-chamber, and triple-chamber systems; each system has its own advantages and disadvantages. Despite the emergence of digital drainage systems in recent years, their high cost hinders their widespread adoption. Based on this premise, our research team has achieved a patent for a micro air pump-integrated chest closed drainage bottle, which has been further developed into a novel device integrating a three-chamber system with negative pressure control and power supply capabilities. This device enables patients undergoing perioperative lung procedures to ambulate freely while simultaneously receiving chest suction therapy-a concept that theoretically promotes rapid postoperative recovery. Moreover, this device offers economic benefits and holds potential for clinical implementation (particularly in economically underdeveloped regions). In this article, we modified the thoracic closed drainage device based on our patent and presented this novel thoracic closed drainage device after 3D printing and assembly.


Sujet(s)
Drainage , Conception d'appareillage , Humains , Drainage/instrumentation , Drainage/méthodes , Drains thoraciques , Pneumonectomie/instrumentation , Pneumonectomie/méthodes , Impression tridimensionnelle , Aspiration (technique)/instrumentation
18.
J Control Release ; 373: 161-171, 2024 Jul 13.
Article de Anglais | MEDLINE | ID: mdl-38996922

RÉSUMÉ

Achieving precise control of nanoparticle size while maintaining consistency and high uniformity is of paramount importance for improving the efficacy of nanoparticle-based therapies and minimizing potential side effects. Although microfluidic technologies are widely used for reliable nanoparticle synthesis, they face challenges in meeting critical homogeneity requirements, mainly due to imperfect mixing efficiency. Furthermore, channel clogging during continuous operation presents a significant obstacle in terms of quality control, as it progressively impedes the mixing behavior necessary for consistent nanoparticle production for therapeutic delivery and complicates the scaling-up process. This study entailed the development of a 3D-printed novel micromixer embedded with hemispherical baffle microstructures, a dual vortex mixer (DVM), which integrates Dean vortices to generate two symmetrical counter-rotating intensified secondary flows. The DVM with a relatively large mixer volume showed rapid mixing characteristics even at a flow rate of several mL min-1 and produced highly uniform lipids, liposomes, and polymer nanoparticles in a size range (50-130 nm) and polydispersity index (PDI) values below 0.15. For the evaluation of products, SARS-CoV-2 Spike mRNA-loaded lipid nanoparticles were examined to verify protein expression in vitro and in vivo using firefly luciferase (FLuc) mRNA. This showed that the performance of the system is comparable to that of a commercial toroidal mixer. Moreover, the vigorous in-situ dispersion of nanoparticles by harnessing the power of vortex physically minimizes the occurrence of aggregation, ensuring consistent production performance without internal clogging of a half-day operation and facilitating quality control of the nanoparticles at desired scales.

19.
Adv Mater ; : e2408374, 2024 Jul 25.
Article de Anglais | MEDLINE | ID: mdl-39049689

RÉSUMÉ

Advances in additive manufacturing in composites have transformed aerospace, medical devices, tissue engineering, and electronics. A key aspect of enhancing properties of 3D-printed objects involves fine-tuning the material by embedding and orienting reinforcement within the structure. Existing methods for orienting these reinforcements are limited by pattern types, alignment, and particle characteristics. Acoustics offers a versatile method to control the particles independent of their size, geometry, and charge, enabling intricate pattern formations. However, integrating acoustics into 3D printing has been challenging due to the scattering of the acoustic field between polymerized layers and unpolymerized resin, resulting in unwanted patterns. To address this challenge, SonoPrint, an innovative acoustically assisted volumetric 3D printer is developed that enables simultaneous reinforcement patterning and printing of the entire structure. SonoPrint generates mechanically tunable composite geometries by embedding reinforcement particles, such as microscopic glass, metal, and polystyrene, within the fabricated structure. This printer employs a standing wave field to create targeted particle motifs-including parallel lines, radial lines, circles, rhombuses, hexagons, and polygons-directly in the photosensitive resin, completing the print in just a few minutes. SonoPrint enhances structural properties and promises to advance volumetric printing, unlocking applications in tissue engineering, biohybrid robots, and composite fabrication.

20.
Article de Anglais | MEDLINE | ID: mdl-39049741

RÉSUMÉ

INTRODUCTION: Microneedles (MNs) are miniaturized, painless, and minimally invasive platforms that have attracted significant attention over recent decades across multiple fields, such as drug delivery, disease monitoring, disease diagnosis, and cosmetics. Several manufacturing methods have been employed to create MNs; however, these approaches come with drawbacks related to complicated, costly, and time-consuming fabrication processes. In this context, employing additive manufacturing (AM) technology for MN fabrication allows for the quick production of intricate MN prototypes with exceptional precision, providing the flexibility to customize MNs according to the desired shape and dimensions. Furthermore, AM demonstrates significant promise in the fabrication of sophisticated transdermal drug delivery systems and medical devices through the integration of MNs with various technologies. AREAS COVERED: This review offers an extensive overview of various AM technologies with great potential for the fabrication of MNs. Different types of MNs and the materials utilized in their fabrication are also discussed. Recent applications of 3D-printed MNs in the fields of transdermal drug delivery and biosensing are highlighted. EXPERT OPINION: This review also mentions the critical obstacles, including drug loading, biocompatibility, and regulatory requirements, which must be resolved to enable the mass-scale adoption of AM methods for MN production, and future trends.

SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE