Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Acta ortop. mex ; 36(4): 216-222, jul.-ago. 2022. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1519957

RESUMO

Resumen: Introducción: las fracturas del radio distal son las más comunes en extremidades superiores. Estandarizar las mediciones radiográficas para su abordaje quirúrgico es importante. Este estudio midió la reproducibilidad intra/interobservador de parámetros radiográficos asociados al éxito quirúrgico en estas fracturas. Material y métodos: diseño transversal retrospectivo con datos secundarios de expedientes clínicos. Se evaluaron radiografías de 112 fracturas en planos posteroanterior y lateral por dos traumatólogos estandarizados en toma de mediciones para calcular cinco parámetros indicativos de éxito postquirúrgico: altura radial, inclinación radial, inclinación volar, varianza cubital y escalón articular. La reproducibilidad de distancias y ángulos se evaluó con el método de Bland-Altman calculando: diferencia media entre mediciones, rango a ± 2 DE y proporción de mediciones fuera de ± 2 DE. El éxito postquirúrgico se comparó en pacientes con/sin obesidad según la media de las dos mediciones de cada evaluador. Resultados: el evaluador 1 tuvo la mayor diferencia intraobservador en altura radial (0.16 mm) y la mayor proporción fuera de ± 2 DE en varianza cubital (8.1%); el evaluador 2 tuvo la mayor diferencia en inclinación volar (1.92o) y la mayor proporción en inclinación radial (10.7%). La mayor diferencia interobservador fue en varianza cubital (1.02 mm) y la mayor proporción fuera de ± 2 DE en altura radial (5.4%). La inclinación radial tuvo la mayor diferencia (1.41o) con 4.5% de mediciones fuera de ± 2 DE. La varianza cubital y la inclinación volar tuvieron la mayor diferencia de éxito postquirúrgico entre evaluadores, sobre todo en pacientes con obesidad. Conclusión: mejorar la calidad radiográfica y estandarizar las mediciones resulta en indicadores más reproducibles.


Abstract: Introduction: distal radius fractures are the most common in upper extremities. Therefore, it is important to standardize radiographic measures for their surgical approach. This study assessed the intra/interobserver reproducibility of radiographic parameters associated with surgical success of distal radius fractures. Material and methods: retrospective cross-sectional design of secondary data extracted from clinical records. Posteroanterior and lateral X-rays of 112 distal radius fractures were assessed by two trauma specialists standardized in the measurements required to compute five parameters indicative of postoperative success: radial height, radial inclination, volar tilt, ulnar variance, and articular stepoff. The reproducibility of distances and angles was evaluated using the Bland-Altman method, calculating the mean of the difference between measurements, the range at ± 2 SD, and the proportion of measurements outside ± 2 SD. Postoperative success was also compared between patients with and without obesity according to the mean of the two measures made by each evaluator. Results: evaluator 1 had the largest intra-observer difference in radial height (0.16 mm) and the largest proportion outside ± 2 SD in ulnar variance (8.1%); evaluator 2 had the largest difference in volar tilt (1.92o) and the highest proportion in radial inclination (10.7%). The largest inter-observer difference was for ulnar variance (1.02 mm) and the largest proportion outside ± 2 SD. for radial height (5.4%). Radial tilt had the largest difference (1.41o) with 4.5% of measurements outside ± 2 SD. Ulnar variance and volar tilt had the largest difference in postoperative success between evaluators, especially in patients with obesity. Conclusion: improving the radiographic quality and standardizing the measurements results in more reproducible indicators.

2.
Acta Ortop Mex ; 36(4): 216-222, 2022.
Artigo em Espanhol | MEDLINE | ID: mdl-36977640

RESUMO

INTRODUCTION: distal radius fractures are the most common in upper extremities. Therefore, it is important to standardize radiographic measures for their surgical approach. This study assessed the intra/interobserver reproducibility of radiographic parameters associated with surgical success of distal radius fractures. MATERIAL AND METHODS: retrospective cross-sectional design of secondary data extracted from clinical records. Posteroanterior and lateral X-rays of 112 distal radius fractures were assessed by two trauma specialists standardized in the measurements required to compute five parameters indicative of postoperative success: radial height, radial inclination, volar tilt, ulnar variance, and articular stepoff. The reproducibility of distances and angles was evaluated using the Bland-Altman method, calculating the mean of the difference between measurements, the range at ± 2 SD, and the proportion of measurements outside ± 2 SD. Postoperative success was also compared between patients with and without obesity according to the mean of the two measures made by each evaluator. RESULTS: evaluator 1 had the largest intra-observer difference in radial height (0.16 mm) and the largest proportion outside ± 2 SD in ulnar variance (8.1%); evaluator 2 had the largest difference in volar tilt (1.92o) and the highest proportion in radial inclination (10.7%). The largest inter-observer difference was for ulnar variance (1.02 mm) and the largest proportion outside ± 2 SD. for radial height (5.4%). Radial tilt had the largest difference (1.41o) with 4.5% of measurements outside ± 2 SD. Ulnar variance and volar tilt had the largest difference in postoperative success between evaluators, especially in patients with obesity. CONCLUSION: improving the radiographic quality and standardizing the measurements results in more reproducible indicators.


INTRODUCCIÓN: las fracturas del radio distal son las más comunes en extremidades superiores. Estandarizar las mediciones radiográficas para su abordaje quirúrgico es importante. Este estudio midió la reproducibilidad intra/interobservador de parámetros radiográficos asociados al éxito quirúrgico en estas fracturas. MATERIAL Y MÉTODOS: diseño transversal retrospectivo con datos secundarios de expedientes clínicos. Se evaluaron radiografías de 112 fracturas en planos posteroanterior y lateral por dos traumatólogos estandarizados en toma de mediciones para calcular cinco parámetros indicativos de éxito postquirúrgico: altura radial, inclinación radial, inclinación volar, varianza cubital y escalón articular. La reproducibilidad de distancias y ángulos se evaluó con el método de Bland-Altman calculando: diferencia media entre mediciones, rango a ± 2 DE y proporción de mediciones fuera de ± 2 DE. El éxito postquirúrgico se comparó en pacientes con/sin obesidad según la media de las dos mediciones de cada evaluador. RESULTADOS: el evaluador 1 tuvo la mayor diferencia intraobservador en altura radial (0.16 mm) y la mayor proporción fuera de ± 2 DE en varianza cubital (8.1%); el evaluador 2 tuvo la mayor diferencia en inclinación volar (1.92o) y la mayor proporción en inclinación radial (10.7%). La mayor diferencia interobservador fue en varianza cubital (1.02 mm) y la mayor proporción fuera de ± 2 DE en altura radial (5.4%). La inclinación radial tuvo la mayor diferencia (1.41o) con 4.5% de mediciones fuera de ± 2 DE. La varianza cubital y la inclinación volar tuvieron la mayor diferencia de éxito postquirúrgico entre evaluadores, sobre todo en pacientes con obesidad. CONCLUSIÓN: mejorar la calidad radiográfica y estandarizar las mediciones resulta en indicadores más reproducibles.


Assuntos
Fraturas do Rádio , Fraturas do Punho , Humanos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Estudos Transversais , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Rádio (Anatomia) , Fixação Interna de Fraturas/métodos , Placas Ósseas , Amplitude de Movimento Articular , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA