Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Resuscitation ; 192: 109964, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37683997

RESUMO

AIM: To evaluate neuron-specific enolase (NSE) thresholds for prediction of neurological outcome after cardiac arrest and to analyze the influence of hemolysis and confounders. METHODS: Retrospective analysis from a cardiac arrest registry. Determination of NSE serum concentration and hemolysis-index (h-index) 48-96 hours after cardiac arrest. Evaluation of neurological outcome using the Cerebral Performance Category score (CPC) at hospital discharge. Separate analyses considering CPC 1-3 and CPC 1-2 as good neurological outcome. Analysis of specificity and sensitivity for poor and good neurological outcome prediction with and without exclusion of hemolytic samples (h-index larger than 50). RESULTS: Among 356 survivors three days after cardiac arrest, hemolysis was detected in 28 samples (7.9%). At a threshold of 60 µg/L, NSE predicted poor neurological outcome (CPC 4-5) in all samples with a specificity of 92% (86-95%) and sensitivity of 73% (66-79%). In non-hemolytic samples, specificity was 94% (89-97%) and sensitivity 70% (62-76%). At a threshold of 100 µg/L, specificity was 98% (95-100%, all samples) and 99% (95-100%, non-hemolytic samples), and sensitivity 58% (51-65%) and 55% (47-63%), respectively. Possible confounders for elevated NSE in patients with good neurological outcome were ECMO, malignancies, blood transfusions and acute brain diseases. Nine patients with NSE below 17 µg/L had CPC 5, all had plausible death causes other than hypoxic-ischemic encephalopathy. CONCLUSIONS: NSE concentrations higher than 100 µg/L predicted poor neurological outcome with high specificity. An NSE less than 17 µg/L indicated absence of severe hypoxic-ischemic encephalopathy. Hemolysis and other confounders need to be considered. INSTITUTIONAL PROTOCOL NUMBER: The local ethics committee (board name: Ethikkommission der Charité) approved this study by the number: EA2/066/23, approval date: 28th June 2023, study title "'ROSC' - Resuscitation Outcome Study."


Assuntos
Parada Cardíaca , Hipóxia-Isquemia Encefálica , Parada Cardíaca Extra-Hospitalar , Humanos , Biomarcadores , Parada Cardíaca/terapia , Hemólise , Parada Cardíaca Extra-Hospitalar/terapia , Fosfopiruvato Hidratase , Prognóstico , Estudos Prospectivos , Estudos Retrospectivos
2.
J Neurol ; 270(12): 5999-6009, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37639017

RESUMO

OBJECTIVE: Bilaterally absent cortical somatosensory evoked potentials (SSEPs) reliably predict poor outcome in comatose cardiac arrest (CA) patients. Cortical SSEP amplitudes are a recent prognostic extension; however, amplitude thresholds, inter-recording, and inter-rater agreement remain uncertain. METHODS: In a retrospective multicenter cohort study, we determined cortical SSEP amplitudes of comatose CA patients using a standardized evaluation pathway. We studied inter-recording agreement in repeated SSEPs and inter-rater agreement by four raters independently determining 100 cortical SSEP amplitudes. Primary outcome was assessed using the cerebral performance category (CPC) upon intensive care unit discharge dichotomized into good (CPC 1-3) and poor outcome (CPC 4-5). RESULTS: Of 706 patients with SSEPs with median 3 days after CA, 277 (39.2%) had good and 429 (60.8%) poor outcome. Of patients with bilaterally absent cortical SSEPs, one (0.8%) survived with CPC 3 and 130 (99.2%) had poor outcome. Otherwise, the lowest cortical SSEP amplitude in good outcome patients was 0.5 µV. 184 (42.9%) of 429 poor outcome patients had lower cortical SSEP amplitudes. In 106 repeated SSEPs, there were 6 (5.7%) with prognostication-relevant changes in SSEP categories. Following a standardized evaluation pathway, inter-rater agreement was almost perfect with a Fleiss' kappa of 0.88. INTERPRETATION: Bilaterally absent and cortical SSEP amplitudes below 0.5 µV predicted poor outcome with high specificity. A standardized evaluation pathway provided high inter-rater and inter-recording agreement. Regain of consciousness in patients with bilaterally absent cortical SSEPs rarely occurs. High-amplitude cortical SSEP amplitudes likely indicate the absence of severe brain injury.


Assuntos
Coma , Parada Cardíaca , Humanos , Estudos de Coortes , Coma/diagnóstico , Coma/etiologia , Parada Cardíaca/complicações , Estudos Retrospectivos , Potenciais Somatossensoriais Evocados/fisiologia , Prognóstico
3.
Crit Care Med ; 49(12): e1212-e1222, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34374503

RESUMO

OBJECTIVES: Prognostication of outcome is an essential step in defining therapeutic goals after cardiac arrest. Gray-white-matter ratio obtained from brain CT can predict poor outcome. However, manual placement of regions of interest is a potential source of error and interrater variability. Our objective was to assess the performance of poor outcome prediction by automated quantification of changes in brain CTs after cardiac arrest. DESIGN: Observational, derivation/validation cohort study design. Outcome was determined using the Cerebral Performance Category upon hospital discharge. Poor outcome was defined as death or unresponsive wakefulness syndrome/coma. CTs were automatically decomposed using coregistration with a brain atlas. SETTING: ICUs at a large, academic hospital with circulatory arrest center. PATIENTS: We identified 433 cardiac arrest patients from a large previously established database with brain CTs within 10 days after cardiac arrest. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Five hundred sixteen brain CTs were evaluated (derivation cohort n = 309, validation cohort n = 207). Patients with poor outcome had significantly lower radiodensities in gray matter regions. Automated GWR_si (putamen/posterior limb of internal capsule) was performed with an area under the curve of 0.86 (95%-CI: 0.80-0.93) for CTs taken later than 24 hours after cardiac arrest (similar performance in the validation cohort). Poor outcome (Cerebral Performance Category 4-5) was predicted with a specificity of 100% (95% CI, 87-100%, derivation; 88-100%, validation) at a threshold of less than 1.10 and a sensitivity of 49% (95% CI, 36-58%, derivation) and 38% (95% CI, 27-50%, validation) for CTs later than 24 hours after cardiac arrest. Sensitivity and area under the curve were lower for CTs performed within 24 hours after cardiac arrest. CONCLUSIONS: Automated gray-white-matter ratio from brain CT is a promising tool for prediction of poor neurologic outcome after cardiac arrest with high specificity and low-to-moderate sensitivity. Prediction by gray-white-matter ratio at the basal ganglia level performed best. Sensitivity increased considerably for CTs performed later than 24 hours after cardiac arrest.


Assuntos
Encéfalo/diagnóstico por imagem , Parada Cardíaca/complicações , Aprendizado de Máquina/normas , Tomografia Computadorizada por Raios X/instrumentação , Idoso , Estudos de Coortes , Feminino , Parada Cardíaca/diagnóstico por imagem , Humanos , Aprendizado de Máquina/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Curva ROC , Tomografia Computadorizada por Raios X/métodos , Estudos de Validação como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...