Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Invest Ophthalmol Vis Sci ; 65(5): 39, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38787546

RESUMO

Purpose: Post-saccadic oscillations (PSOs) reflect movements of gaze that result from motion of the pupil and lens relative to the eyeball rather than eyeball rotations. Here, we analyzed the characteristics of PSOs in subjects with age-related macular degeneration (AMD), retinitis pigmentosa (RP), and normal vision (NV). Our aim was to assess the differences in PSOs between people with vision loss and healthy controls because PSOs affect retinal image stability after each saccade. Methods: Participants completed a horizontal saccade task and their gaze was measured using a pupil-based eye tracker. Oscillations occurring in the 80 to 200 ms post-saccadic period were described with a damped oscillation model. We compared the amplitude, decay time constant, and frequency of the PSOs for the three different groups. We also examined the correlation between these PSO parameters and the amplitude, peak velocity, and final deceleration of the preceding saccades. Results: Subjects with vision loss (AMD, n = 6, and RP, n = 5) had larger oscillation amplitudes, longer decay constants, and lower frequencies than subjects with NV (n = 7). The oscillation amplitudes increased with increases in saccade deceleration in all three groups. The other PSO parameters, however, did not show consistent correlations with either saccade amplitude or peak velocity. Conclusions: Post-saccadic fixation stability in AMD and RP is reduced due to abnormal PSOs. The differences with respect to NV are not due to differences in saccade kinematics, suggesting that anatomic and neuronal variations affect the suspension of the iris and the lens in the patients' eyes.


Assuntos
Fixação Ocular , Degeneração Macular , Pupila , Retinose Pigmentar , Movimentos Sacádicos , Humanos , Movimentos Sacádicos/fisiologia , Retinose Pigmentar/fisiopatologia , Feminino , Masculino , Fixação Ocular/fisiologia , Pessoa de Meia-Idade , Degeneração Macular/fisiopatologia , Idoso , Pupila/fisiologia , Cristalino/fisiopatologia , Adulto , Acuidade Visual/fisiologia
2.
Clin Exp Ophthalmol ; 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38812454

RESUMO

BACKGROUND: To examine whether the clinical performance of predicting late age-related macular degeneration (AMD) development is improved through using multimodal imaging (MMI) compared to using colour fundus photography (CFP) alone, and how this compares with a basic prediction model using well-established AMD risk factors. METHODS: Individuals with AMD in this study underwent MMI, including optical coherence tomography (OCT), fundus autofluorescence, near-infrared reflectance and CFP at baseline, and then at 6-monthly intervals for 3-years to determine MMI-defined late AMD development. Four retinal specialists independently assessed the likelihood that each eye at baseline would progress to MMI-defined late AMD over 3-years with CFP, and then with MMI. Predictive performance with CFP and MMI were compared to each other, and to a basic prediction model using age, presence of pigmentary abnormalities, and OCT-based drusen volume. RESULTS: The predictive performance of the clinicians using CFP [AUC = 0.75; 95% confidence interval (CI) = 0.68-0.82] improved when using MMI (AUC = 0.79; 95% CI = 0.72-0.85; p = 0.034). However, a basic prediction model outperformed clinicians using either CFP or MMI (AUC = 0.85; 95% CI = 0.78-91; p ≤ 0.002). CONCLUSIONS: Clinical performance for predicting late AMD development was improved by using MMI compared to CFP. However, a basic prediction model using well-established AMD risk factors outperformed retinal specialists, suggesting that such a model could further improve personalised counselling and monitoring of individuals with the early stages of AMD in clinical practice.

3.
Sleep Breath ; 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38504043

RESUMO

PURPOSE: Obstructive sleep apnoea (OSA) is common, yet often undiagnosed. Self-administered, overnight pulse oximetry (OPO) could screen for OSA in asymptomatic, older populations. However, the inter-night variability of OPO in an asymptomatic, older population is unknown. We determined the inter-night variability of home OPO parameters in an older population and correlated with sleep questionnaires. METHODS: Participants > 50 years without a diagnosis of OSA undertook home OPO for three consecutive nights and completed two sleep questionnaires (STOP-BANG (SBQ) and Epworth Sleepiness Score (ESS)). Analysis was performed with linear mixed models and Spearman's correlation coefficient. RESULTS: There was no difference in oxygen desaturation index (ODI), MeanSpO2, MinimumSpO2, and time spent with SpO2 < 90% (T90) across two or three nights (P ≥ 0.282). However, the variability of all parameters across nights increased with the magnitude of departure from normal values (P ≤ 0.002). All OPO parameters were associated with age (P ≤ 0.034) and body mass index (P ≤ 0.049). There was a weak correlation between three OPO parameters and SBQ (absolute ρ = 0.22 to 0.32; P ≤ 0.021), but not ESS (P ≥ 0.254). CONCLUSION: Inter-night variability of home OPO was minimal when values were near-normal in an older population. However, as values depart from normal, the inter-night variability increases, indicating the need for multiple night recordings. Low correlation to sleep questionnaires suggest the need for more robust OSA questionnaires in an asymptomatic population.

4.
Retina ; 44(2): 214-221, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37831941

RESUMO

PURPOSE: To investigate the prognostic value of quantifying optical coherence tomography (OCT)-defined hyperreflective foci (HRF) that do not correspond to hyperpigmentary abnormalities (HPAs) on color fundus photographs (CFPs)-HRF (OCT+/CFP-) -when considered in addition to HPA extent, for predicting late age-related macular degeneration development. This study sought to understand the impact of HRF (OCT+/CFP-) extent on visual sensitivity. METHODS: Two hundred eighty eyes from 140 participants with bilateral large drusen underwent imaging and microperimetry at baseline, and then 6-monthly for 3-years. The extent of HPAs on CFPs and HRF (OCT+/CFP-) on OCT was quantified at baseline. Predictive models for progression to late age-related macular degeneration, accounting for drusen volume and age, were developed using HPA extent, with and without HRF (OCT+/CFP-) extent. The association between HPA and HRF (OCT+/CFP-) extent with sector-based visual sensitivity was also evaluated. RESULTS: Incorporating HRF (OCT+/CFP-) extent did not improve the predictive performance for late age-related macular degeneration development ( P ≥ 0.32). Increasing HPA and HRF (OCT+/CFP-) extent in each sector were independently and significantly associated with reduced sector-based visual sensitivity ( P ≤ 0.004). CONCLUSION: The addition of HRF (OCT+/CFP-) extent to HPA extent did not improve the prediction of late age-related macular degeneration development. HRF (OCT+/CFP-) extent was also independently associated with local reductions in visual sensitivity, after accounting for HPAs.


Assuntos
Degeneração Macular , Drusas Retinianas , Humanos , Degeneração Macular/diagnóstico , Retina , Fundo de Olho , Técnicas de Diagnóstico Oftalmológico , Prognóstico , Tomografia de Coerência Óptica/métodos , Drusas Retinianas/diagnóstico
5.
Invest Ophthalmol Vis Sci ; 64(3): 1, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36857076

RESUMO

Purpose: Most eye-movement studies in patients with visual field defects have examined the strategies that patients use while exploring a visual scene, but they have not investigated saccade kinematics. In healthy vision, saccade trajectories follow the remarkably stereotyped "main sequence": saccade duration increases linearly with saccade amplitude; peak velocity also increases linearly for small amplitudes, but approaches a saturation limit for large amplitudes. Recent theories propose that these relationships reflect the brain's attempt to optimize vision when planning eye movements. Therefore, in patients with bilateral retinal damage, saccadic behavior might differ to optimize vision under the constraints imposed by the visual field defects. Methods: We compared saccadic behavior of patients with central vision loss, due to age-related macular degeneration (AMD), and patients with peripheral vision loss, due to retinitis pigmentosa (RP), to that of controls with normal vision (NV) using a horizontal saccade task. Results: Both patient groups demonstrated deficits in saccade reaction times and target localization behavior, as well as altered saccade kinematics. Saccades were generally slower and the shape of the velocity profiles were often atypical, especially in the patients with RP. In the patients with AMD, the changes were far less dramatic. For both groups, saccade kinematics were affected most when the target was in the subjects' blind field. Conclusions: We conclude that defects of the central and peripheral retina have distinct effects on the saccade main sequence, and that visual inputs play an important role in planning the kinematics of a saccade.


Assuntos
Degeneração Macular , Doenças Retinianas , Retinose Pigmentar , Humanos , Movimentos Sacádicos , Movimentos Oculares , Escotoma
6.
Transl Vis Sci Technol ; 12(3): 20, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36943168

RESUMO

Purpose: Accurate mapping of phosphene locations from visual prostheses is vital to encode spatial information. This process may involve the subject pointing to evoked phosphene locations with their finger. Here, we demonstrate phosphene mapping for a retinal implant using eye movements and compare it with retinotopic electrode positions and previous results using conventional finger-based mapping. Methods: Three suprachoroidal retinal implant recipients (NCT03406416) indicated the spatial position of phosphenes. Electrodes were stimulated individually, and the subjects moved their finger (finger based) or their eyes (gaze based) to the perceived phosphene location. The distortion of the measured phosphene locations from the expected locations (retinotopic electrode locations) was characterized with Procrustes analysis. Results: The finger-based phosphene locations were compressed spatially relative to the expected locations all three subjects, but preserved the general retinotopic arrangement (scale factors ranged from 0.37 to 0.83). In two subjects, the gaze-based phosphene locations were similar to the expected locations (scale factors of 0.72 and 0.99). For the third subject, there was no apparent relationship between gaze-based phosphene locations and electrode locations (scale factor of 0.07). Conclusions: Gaze-based phosphene mapping was achievable in two of three tested retinal prosthesis subjects and their derived phosphene maps correlated well with the retinotopic electrode layout. A third subject could not produce a coherent gaze-based phosphene map, but this may have revealed that their phosphenes were indistinct spatially. Translational Relevance: Gaze-based phosphene mapping is a viable alternative to conventional finger-based mapping, but may not be suitable for all subjects.


Assuntos
Movimentos Oculares , Próteses Visuais , Humanos , Fosfenos , Transtornos da Visão , Retina/cirurgia
8.
Transl Vis Sci Technol ; 11(9): 4, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36066322

RESUMO

Purpose: The electrode to retina (ER) distance is an important contributory factor to the safety and efficacy of a suprachoroidal retinal prosthesis. Measuring ER distance may be performed by different observers during multisite studies. The aim of this study was to assess the interobserver agreement in measuring ER distance. Methods: Three independent, trained observers measured ER distance from the center of each suprachoroidal electrode to the inner retinal pigment epithelium in spectral-domain optical coherence tomography (SD-OCT) B-scans. A total of 121 ER distance measurements from 77 B-scans collected over 5 months from one subject implanted with a second-generation 44-channel suprachoroidal retinal prosthesis (NCT03406416) were made by each observer. Results: ER distance ranged from 208 to 509 µm. Pearson's correlation coefficient (ρ) showed agreement of 0.99 (95% confidence interval [CI] = 0.98-0.99) in measuring ER for each pairwise comparison. The mean difference in ER distance between observers ranged from 2.4 to 6.4 µm with pairwise limits of agreement (95% CI) of ±20 µm (5.5% of mean). Intraclass correlation coefficient (ICC) showed agreement of 0.98 (95% CI = 0.97-0.99) between observers. Conclusions: There is high agreement in measuring ER distances for suprachoroidal retinal prostheses using our systematic approach between multiple, trained observers, supporting the use of a single observer for each image. Translational Relevance: High interobserver agreement outcomes indicate that multiple, trained observers can be used to take ER measurements across different images in suprachoroidal retinal prosthesis studies. This improves multisite study efficiency and gives confidence in interpreting results relating to the safety and efficacy of suprachoroidal retinal prostheses.


Assuntos
Próteses Visuais , Eletrodos , Humanos , Variações Dependentes do Observador , Retina/diagnóstico por imagem , Retina/cirurgia , Tomografia de Coerência Óptica/métodos
9.
Ophthalmology ; 129(10): e150-e151, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35863962
10.
Transl Vis Sci Technol ; 11(6): 12, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35696133

RESUMO

Purpose: To report the long-term observations of the electrode-tissue interface and perceptual stability in humans after chronic stimulation with a 44-channel suprachoroidal retinal implant. Methods: Four subjects (S1-4) with end-stage retinitis pigmentosa received the implant unilaterally (NCT03406416). Electrode impedances, electrode-retina distance (measured using optical coherence tomography imaging), and perceptual thresholds were monitored up to 181 weeks after implantation as the subjects used the prosthesis in the laboratory and in daily life. Stimulation charge density was limited to 32 µC/cm2 per phase. Results: Electrode impedances were stable longitudinally. The electrode-retina distances increased after surgery and then stabilized, and were well-described by an asymptotic exponential model. The stabilization of electrode-retina distances was variable between subjects, stabilizing after 45 weeks for S1, 63 weeks for S2, and 24 weeks for S3 (linear regression; Pgradient > 0.05). For S4, a statistically significant increase in electrode-retina distance persisted (P < 0.05), but by the study end point the rate of increase was clinically insignificant (exponential model: 0.33 µm/wk). Perceptual electrical thresholds were stable in one subject, decreased over time in two subjects (linear model; P < 0.05), and increased slightly in one subject but remained within the predefined charge limits (P = 0.02). Conclusions: Chronic stimulation with the suprachoroidal retinal prosthesis over 3 years resulted in stable impedances, small individual changes in perceptual electrical thresholds, and no clinically significant increase in electrode-retina distances after a period of settling after surgery. Translational Relevance: Chronic stimulation with the 44-channel suprachoroidal retinal implant with a charge density of up to 32 µC/cm2 per phase is suitable for long-term use in humans.


Assuntos
Retinose Pigmentar , Próteses Visuais , Estimulação Elétrica/métodos , Humanos , Microeletrodos , Retina/diagnóstico por imagem , Retina/cirurgia , Retinose Pigmentar/cirurgia
11.
Ophthalmology ; 129(6): 653-660, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35120992

RESUMO

PURPOSE: To determine the prognostic significance and impact on visual function of the cuticular drusen phenotype in a cohort with intermediate age-related macular degeneration (AMD). DESIGN: Longitudinal, observational study. PARTICIPANTS: Participants aged 50 years or older, with bilateral large conventional drusen, without late AMD. METHODS: Multimodal imaging (MMI) and microperimetry were performed at baseline and then every 6 months for up to 3 years. Eyes were graded for the MMI-based presence of cuticular drusen at baseline. Color fundus photographs were used to grade for the presence of pigmentary abnormalities. OCT scans were used to calculate drusen volume. The associations between cuticular drusen and progression to MMI-defined late AMD (including OCT signs of atrophy) and the impact on visual sensitivity were examined with and without adjustment for the confounders of baseline age, pigmentary abnormalities, and drusen volume. MAIN OUTCOME MEASURES: Time to develop MMI-defined late AMD and change in mean visual sensitivity. RESULTS: A total of 280 eyes from 140 participants were included, with 70 eyes from 35 individuals (25%) having cuticular drusen at baseline. Cuticular drusen were not significantly associated with an increased rate of progression to late AMD with and without adjustment for confounders (P ≥ 0.784 for both). In an adjusted model, cuticular drusen were not associated with lower baseline visual sensitivity (P = 0.758) or a faster rate of visual sensitivity decline (P = 0.196). CONCLUSIONS: In a cohort with bilateral large conventional drusen, individuals with the cuticular drusen phenotype had neither a higher nor lower risk of developing late AMD over 3 years and were not associated with a difference in rate of visual sensitivity decline compared with those without this phenotype. As such, individuals with this phenotype currently warrant similar monitoring strategies as those with conventional drusen.


Assuntos
Degeneração Macular , Drusas Retinianas , Lâmina Basilar da Corioide/patologia , Progressão da Doença , Oftalmopatias Hereditárias , Humanos , Degeneração Macular/complicações , Degeneração Macular/diagnóstico , Drusas Retinianas/diagnóstico , Tomografia de Coerência Óptica/métodos
12.
Trends Genet ; 38(4): 312-316, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35093239

RESUMO

Reticular pseudodrusen (RPD) are subretinal deposits that, when observed with age-related macular degeneration (AMD), form a distinct phenotype, often associated with late-stage disease. To date, RPD genetic risk associations overlap six well-established AMD-risk regions. Determining RPD-specific underlying genetic causes by using adequate imaging methods should improve our understanding of the pathophysiology of RPD.


Assuntos
Degeneração Macular , Drusas Retinianas , Humanos , Degeneração Macular/complicações , Degeneração Macular/genética , Drusas Retinianas/complicações , Drusas Retinianas/genética , Fatores de Risco
13.
Ophthalmol Retina ; 6(4): 284-290, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34871775

RESUMO

PURPOSE: To examine the association between hyporeflective cores within drusen (HCD) and disease progression in age-related macular degeneration (AMD) and with visual function. DESIGN: Longitudinal observational study. PARTICIPANTS: Two hundred and eighty eyes from 140 participants with bilateral large drusen, without late AMD. METHODS: Multimodal imaging and microperimetry were performed at baseline and subsequently every 6 months for up to 3 years. Baseline OCT scans were graded for the presence of HCD and used to calculate drusen volume. The total area of the drusenoid lesions containing hyporeflective cores (HCD extent) on color fundus photographs (CFPs) was calculated. CFPs were also graded for the presence of pigmentary abnormalities. The association between HCD extent with progression to late AMD (including OCT signs of atrophy) and visual sensitivity measured using microperimetry at baseline and its rate of change over time was evaluated with and without adjustment for confounders of drusen volume, pigmentary abnormalities, and age. MAIN OUTCOME MEASURES: Time to develop late AMD and visual sensitivity. RESULTS: Twenty (7%) eyes from 12 (9%) individuals were found to have HCD at baseline, which was associated with a nonsignificantly increased rate of progression to late AMD (unadjusted P = 0.050). HCD extent was significantly associated with an increased rate of progression to late AMD (unadjusted P = 0.034) and lower visual sensitivity at baseline (unadjusted P < 0.001). However, these associations were no longer significant (P ≥ 0.264 for both) after adjusting for known risk factors for AMD progression. HCD extent was also not associated with a faster rate of visual sensitivity decline before the development of late AMD, with or without adjustment (P ≥ 0.674 for both). Increasing age and larger drusen volume were associated with HCD extent (P ≤ 0.041). CONCLUSIONS: In a cohort with bilateral large drusen, HCD presence and extent were not independently associated with an increased rate of progression to late AMD over 3 years, nor with lower visual sensitivity or an increased rate of visual sensitivity decline before the development of late AMD, after adjusting for known risk factors for disease progression.


Assuntos
Degeneração Macular , Drusas Retinianas , Progressão da Doença , Humanos , Degeneração Macular/complicações , Degeneração Macular/diagnóstico , Degeneração Macular/patologia , Estudos Prospectivos , Drusas Retinianas/complicações , Drusas Retinianas/etiologia , Tomografia de Coerência Óptica/métodos
14.
Transl Vis Sci Technol ; 10(10): 12, 2021 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-34581770

RESUMO

Purpose: To report the initial safety and efficacy results of a second-generation (44-channel) suprachoroidal retinal prosthesis at 56 weeks after device activation. Methods: Four subjects, with advanced retinitis pigmentosa and bare-light perception only, enrolled in a phase II trial (NCT03406416). A 44-channel electrode array was implanted in a suprachoroidal pocket. Device stability, efficacy, and adverse events were investigated at 12-week intervals. Results: All four subjects were implanted successfully and there were no device-related serious adverse events. Color fundus photography indicated a mild postoperative subretinal hemorrhage in two recipients, which cleared spontaneously within 2 weeks. Optical coherence tomography confirmed device stability and position under the macula. Screen-based localization accuracy was significantly better for all subjects with device on versus device off. Two subjects were significantly better with the device on in a motion discrimination task at 7, 15, and 30°/s and in a spatial discrimination task at 0.033 cycles per degree. All subjects were more accurate with the device on than device off at walking toward a target on a modified door task, localizing and touching tabletop objects, and detecting obstacles in an obstacle avoidance task. A positive effect of the implant on subjects' daily lives was confirmed by an orientation and mobility assessor and subject self-report. Conclusions: These interim study data demonstrate that the suprachoroidal prosthesis is safe and provides significant improvements in functional vision, activities of daily living, and observer-rated quality of life. Translational Relevance: A suprachoroidal prosthesis can provide clinically useful artificial vision while maintaining a safe surgical profile.


Assuntos
Retinose Pigmentar , Próteses Visuais , Atividades Cotidianas , Humanos , Qualidade de Vida , Visão Ocular
15.
Transl Vis Sci Technol ; 10(10): 7, 2021 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-34383875

RESUMO

Purpose: In a clinical trial (NCT03406416) of a second-generation (44-channel) suprachoroidal retinal prosthesis implanted in subjects with late-stage retinitis pigmentosa (RP), we assessed performance in real-world functional visual tasks and emotional well-being. Methods: The Functional Low-Vision Observer Rated Assessment (FLORA) and Impact of Vision Impairment-Very Low Vision (IVI-VLV) instruments were administered to four subjects before implantation and after device fitting. The FLORA contains 13 self-reported and 35 observer-reported items ranked for ease of conducting task (impossible-easy, central tendency given as mode). The IVI-VLV instrument quantified the impact of low vision on daily activities and emotional well-being. Results: Three subjects completed the FLORA for two years after device fitting; the fourth subject ceased participation in the FLORA after fitting for reasons unrelated to the device. For all subjects at each post-fitting visit, the mode ease of task with device ON was better or equal to device OFF. Ease of task improved over the first six months with device ON, then remained stable. Subjects reported improvements in mobility, functional vision, and quality of life with device ON. The IVI-VLV suggested self-assessed vision-related quality of life was not impacted by device implantation or usage. Conclusions: Subjects demonstrated sustained improved ease of task scores with device ON compared to OFF, indicating the device has a positive impact in the real-world setting. Translational Relevance: Our suprachoroidal retinal prosthesis shows potential utility in everyday life, by enabling an increased environmental awareness and improving access to sensory information for people with end-stage RP.


Assuntos
Retinose Pigmentar , Baixa Visão , Próteses Visuais , Humanos , Qualidade de Vida , Retinose Pigmentar/cirurgia , Visão Ocular
16.
J Neural Eng ; 17(4): 045014, 2020 08 05.
Artigo em Inglês | MEDLINE | ID: mdl-32659750

RESUMO

OBJECTIVE: Due to their increased proximity to retinal ganglion cells (RGCs), epiretinal visual prostheses present the opportunity for eliciting phosphenes with low thresholds through direct RGC activation. This study characterised the in vivo performance of a novel prototype monolithic epiretinal prosthesis, containing Nitrogen incorporated ultrananocrystalline (N-UNCD) diamond electrodes. APPROACH: A prototype implant containing up to twenty-five 120 × 120 µm N-UNCD electrodes was implanted into 16 anaesthetised cats and attached to the retina either using a single tack or via magnetic coupling with a suprachoroidally placed magnet. Multiunit responses to retinal stimulation using charge-balanced biphasic current pulses were recorded acutely in the visual cortex using a multichannel planar array. Several stimulus parameters were varied including; the stimulating electrode, stimulus polarity, phase duration, return configuration and the number of electrodes stimulated simultaneously. MAIN RESULTS: The rigid nature of the device and its form factor necessitated complex surgical procedures. Surgeries were considered successful in 10/16 animals and cortical responses to single electrode stimulation obtained in eight animals. Clinical imaging and histological outcomes showed severe retinal trauma caused by the device in situ in many instances. Cortical measures were found to significantly depend on the surgical outcomes of individual experiments, phase duration, return configuration and the number of electrodes stimulated simultaneously, but not stimulus polarity. Cortical thresholds were also found to increase over time within an experiment. SIGNIFICANCE: The study successfully demonstrated that an epiretinal prosthesis containing diamond electrodes could produce cortical activity with high precision, albeit only in a small number of cases. Both surgical approaches were highly challenging in terms of reliable and consistent attachment to and stabilisation against the retina, and often resulted in severe retinal trauma. There are key challenges (device form factor and attachment technique) to be resolved for such a device to progress towards clinical application, as current surgical techniques are unable to address these issues.


Assuntos
Diamante , Próteses Visuais , Animais , Gatos , Estimulação Elétrica , Eletrodos , Eletrodos Implantados , Estudos de Viabilidade , Retina
17.
Transl Vis Sci Technol ; 9(13): 31, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33384885

RESUMO

Purpose: To investigate oculomotor behavior in response to dynamic stimuli in retinal implant recipients. Methods: Three suprachoroidal retinal implant recipients performed a four-alternative forced-choice motion discrimination task over six sessions longitudinally. Stimuli were a single white bar ("moving bar") or a series of white bars ("moving grating") sweeping left, right, up, or down across a 42″ monitor. Performance was compared with normal video processing and scrambled video processing (randomized image-to-electrode mapping to disrupt spatiotemporal structure). Eye and head movement was monitored throughout the task. Results: Two subjects had diminished performance with scrambling, suggesting retinotopic discrimination was used in the normal condition and made smooth pursuit eye movements congruent to the moving bar stimulus direction. These two subjects also made stimulus-related eye movements resembling optokinetic reflex (OKR) for moving grating stimuli, but the movement was incongruent with stimulus direction. The third subject was less adept at the task, appeared primarily reliant on head position cues (head movements were congruent to stimulus direction), and did not exhibit retinotopic discrimination and associated eye movements. Conclusions: Our observation of smooth pursuit indicates residual functionality of cortical direction-selective circuits and implies a more naturalistic perception of motion than expected. A distorted OKR implies improper functionality of retinal direction-selective circuits, possibly due to retinal remodeling or the non-selective nature of the electrical stimulation. Translational Relevance: Retinal implant users can make naturalistic eye movements in response to moving stimuli, highlighting the potential for eye tracker feedback to improve perceptual localization and image stabilization in camera-based visual prostheses.


Assuntos
Próteses Visuais , Movimentos Oculares , Movimentos da Cabeça , Humanos , Estimulação Luminosa , Acompanhamento Ocular Uniforme
18.
Transl Vis Sci Technol ; 8(6): 3, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31737427

RESUMO

PURPOSE: To determine whether change in retinal sensitivity in areas with subretinal or intraretinal fluid secondary to age-related macular degeneration (AMD) precedes visual symptoms. If confirmed, retinal sensitivity testing could be used for home monitoring in AMD. METHODS: Individuals with intermediate AMD enrolled in a longitudinal study were seen every 6 months and underwent best-corrected visual acuity testing (BCVA), spectral domain-optical coherence tomography (SD-OCT), and microperimetry. Asymptomatic individuals who developed incidental, reading center-determined retinal fluid detected on SD-OCT were identified. The point-wise sensitivity (PWS) at the time of fluid detection was compared with 6 and 12 months prior. RESULTS: Fourteen of 161 individuals developed fluid without symptoms. PWS over fluid areas at detection was reduced compared with 6 (difference -2.04 dB, P < 0.001) and 12 months (-2.27 dB, P < 0.001) prior. PWS over fluid areas was reduced compared with perifluid areas (difference -1.02 dB, P = 0.03), peripheral areas (-1.51 dB, P < 0.001), nonprogressed fellow eyes (-1.49 dB, P = 0.006), and nonprogressed age-matched intermediate AMD eyes (-2.29 dB, P = 0.001). No difference in BCVA was observed in eyes developing fluid compared to eyes that do not develop fluid (P = 0.76). CONCLUSIONS: Retinal areas with fluid on SD-OCT had a corresponding reduction in retinal sensitivity at the time of fluid detection compared with 6 and 12 months prior, in asymptomatic intermediate AMD without change in BCVA. TRANSLATIONAL RELEVANCE: Development of self-monitoring tools to detect changes in retinal sensitivity may be helpful for early detection of retinal fluid suggestive of progression to neovascular AMD before acuity is affected.

19.
Invest Ophthalmol Vis Sci ; 60(6): 2263-2273, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31112611

RESUMO

Purpose: Peripheral visual field loss (PVFL) due to retinitis pigmentosa (RP) decreases saccades to areas of visual defect, leading to a habitually confined range of eye movement. We investigated the relative contributions of head and eye movement in RP patients and normal-sighted controls to determine whether this reduced eye movement is offset by increased head movement. Methods: Eye-head coordination was examined in 18 early-moderate RP patients, 4 late-stage RP patients, and 19 normal-sighted controls. Three metrics were extracted: the extent of eye, head, and total gaze (eye+head) movement while viewing a naturalistic scene; head gain, the ratio of head movement to total gaze movement during smooth pursuit; and the customary oculomotor range (COMR), the orbital range within which the eye is preferentially maintained during a pro-saccade task. Results: The late-stage RP group had minimal gaze movement and could not discern the naturalistic scene. Variance in head position in early-moderate RP was significantly greater than in controls, whereas variance in total gaze was similar. Head gain was greater in early-moderate RP than in controls, whereas COMR was smaller. Across groups, visual field extent was negatively correlated with head gain and positively correlated with COMR. Accounting for age effects, these results demonstrate increased head movement at the expense of eye movement in participants with PVFL. Conclusions: RP is associated with an increased propensity for head movement during gaze shifts, and the magnitude of this effect is dependent on the severity of visual field loss.


Assuntos
Movimentos Oculares/fisiologia , Movimentos da Cabeça/fisiologia , Retinose Pigmentar/fisiopatologia , Transtornos da Visão/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Retinose Pigmentar/complicações , Transtornos da Visão/etiologia , Campos Visuais/fisiologia
20.
Clin Exp Optom ; 102(5): 506-512, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30834589

RESUMO

BACKGROUND: As the field of retinal prostheses advances, volunteers are required for device trials, and optimal participant recruitment is vital for intervention success. The aims of this study were: (i) to select tests that assess the psychosocial aspects of visual impairment and develop a psychosocial assessment protocol for persons who may be eligible for participation in retinal prostheses trials; (ii) to investigate correlations between these tests; and (iii) to determine associations between psychosocial factors and a person's interest in participating in a retinal prosthesis (bionic eye) trial. METHODS: Cross-sectional study of 72 adults with advanced retinal degeneration. Questionnaire assessments included personality, cognitive ability, social-support, self-efficacy, coping, optimism, depression, and quality of life (Impact of Vision Impairment Profile ([IVI], and Vision and Quality of Life Index [VisQoL]). Level of interest in a retinal prosthesis was also evaluated. RESULTS: All questionnaires were completed without floor or ceiling effects and with minimal respondent burden. Depression correlated with decreased quality of life (rho = -0.37 and 0.40, p < 0.001 for IVI and VisQoL, respectively). Together, depression, gender and vision-specific coping explained 35.2 per cent of variance in IVI quality of life (p < 0.001). Forty-nine per cent of participants were interested in a retinal prosthesis now and 77 per cent in the future. Although the personality trait of 'openness' was somewhat predictive of interest in retinal prostheses (odds ratio 0.78, 95% CI 0.62-0.97), neither severity of vision impairment nor any of the psychosocial measures were strong predictors. CONCLUSIONS: Several existing psychosocial questionnaires can be used for patients with advanced retinal degeneration and may be useful in exploring suitability for a retinal prosthesis or evaluating outcomes. However, the questionnaires used in this study were not good predictors of whether or not a person might be interested in a retinal prosthesis.


Assuntos
Qualidade de Vida/psicologia , Degeneração Retiniana/psicologia , Perfil de Impacto da Doença , Baixa Visão/psicologia , Próteses Visuais/psicologia , Adulto , Idoso , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Psicológicos , Inventário de Personalidade , Degeneração Retiniana/reabilitação , Inquéritos e Questionários , Baixa Visão/reabilitação , Acuidade Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...