Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eye (Lond) ; 33(5): 761-766, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30552422

RESUMO

OBJECTIVES: To describe the 12-month outcomes of the Xen45 glaucoma stent. METHODS: Non-comparative retrospective study of all cases who underwent Xen glaucoma surgery in April 2017 or earlier and completed 12 months of follow-up. The primary outcome measures were intraocular pressure (IOP) reduction and number of glaucoma medications at 12 months postoperatively. The secondary outcome measures were surgical complications and the success rate of surgery at 1 year. Success rate was defined according to the multiple IOP thresholds of 15 mmHg, 18 mmHg, and 21 mmHg with all requiring a drop of 20% and no additional glaucoma surgery. Revision or needling of the Xen conjunctival bleb was not considered to constitute a surgical failure. RESULTS: Sixty-eight eyes were included in the study. Mean IOP dropped from 22.1 mmHg preoperatively to 14.8 mmHg at 12 months, a 33% drop (p < 0.0001). Mean number of glaucoma medications reduced from 2.9 preoperatively to 1.1 at 12 months (p < 0.0001). In total, 54.4% of cases were back on glaucoma medications by 12 months. Success rate varied from 32.4% when defined as IOP ≤ 15 mmHg and ≥ 6 mmHg and ≥ 20% reduction without medications to 70.6% when defined as IOP ≤ 21 mmHg and ≥ 6 mmHg and ≥ 20% reduction with or without medications. Thirty cases (44.1%) required bleb needling or surgical revision. CONCLUSIONS: The Xen45 is effective at reducing IOP and glaucoma medication use at 12 months postoperatively. Patients considering this procedure should be warned that by 12 months postoperatively there is a significant chance of requiring postoperative bleb intervention and glaucoma drops.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto/cirurgia , Idoso , Idoso de 80 Anos ou mais , Alquilantes/administração & dosagem , Túnica Conjuntiva/efeitos dos fármacos , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Mitomicina/administração & dosagem , Procedimentos Cirúrgicos Oftalmológicos , Desenho de Prótese , Implantação de Prótese , Reoperação , Estudos Retrospectivos , Resultado do Tratamento , Acuidade Visual/fisiologia
2.
BMJ Case Rep ; 11(1)2018 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-30567160

RESUMO

Inherited retinal venous beading is a rare retinal vascular disorder that is characterised by tortuosity and beading of the retinal veins. This can potentially lead to vision-threatening complications such as vitreous haemorrhage, macular hard exudation and ischaemia. We report a case of sporadic unilateral retinal venous beading in an 18-year-old white man who was referred by his optician following a routine eye examination. This malformation was unilateral and did not involve any other ocular structure. He had no associated ocular or systemic disorders. When last seen, he did not have any visual complications due to this vascular anomaly.


Assuntos
Doenças Retinianas/diagnóstico , Veia Retiniana/anormalidades , Adolescente , Diagnóstico Diferencial , Predisposição Genética para Doença , Humanos , Masculino , Doenças Retinianas/diagnóstico por imagem , Doenças Retinianas/genética , Tomografia de Coerência Óptica
3.
PLoS One ; 13(6): e0199693, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29944702

RESUMO

PURPOSE: To evaluate changes in colour vision following intravitreal injection of Dexamethasone implant (Ozurdex) in patients with diabetic macular oedema (DMO). Both red-green (RG) and yellow-blue (YB) chromatic sensitivity were assessed using the Colour Assessment & Diagnosis (CAD) test which isolates the use of colour signals and provides age-corrected, statistical limits for normal trichromats. To determine whether colour changes and visual acuity (VA) post-treatment relate to central sub-field retinal thickness (CST). METHODS: Fourteen patients with DMO who were undergoing treatment with Ozurdex were recruited for this study. RG and YB colour thresholds were measured using the CAD test, best corrected visual acuity was assessed using the ETDRS chart and CST was measured using spectral domain optical coherence tomography (SD-OCT). All tests were performed monocularly at baseline and 24 weeks post injection. RESULTS: All patients (n = 14 eyes), had significant loss of RG and YB chromatic sensitivity at baseline (p<0.05). The mean age was 56 ± 9.5 years. The age specific, monocular, upper normal limits for a 56 year old subject are 2.66 for RG and 2.85 for YB. In this study, the measured, pre injection thresholds (mean±SD) were 22.6 ± 11.3 for RG and 16.2 ± 3.76 for YB. There was significant improvement in RG threshold post injection (i.e., 19.2 ± 10.8 (p<0.05)). No significant changes were found in the YB thresholds with corresponding mean and range values of: 15.8 ± 4.6 (p = 0.23). CST pre-treatment was 542 ±135 µm. After treatment and by week 24 the CST values decreased to 435 ±127 µm. CONCLUSIONS: RG colour thresholds provide a sensitive measure of functional change in diabetic subjects with macular oedema. The YB system is damaged severely in the DMO patients studied and shows little or no recovery post treatment. The improvement in VA and particularly in RG colour vision correlate well with the measured decrease in CST. The results suggest that the improvement in the RG chromatic sensitivity can provide a useful biomarker for monitoring the efficacy of treatment in DMO.


Assuntos
Visão de Cores/efeitos dos fármacos , Dexametasona/administração & dosagem , Complicações do Diabetes , Edema Macular , Acuidade Visual/efeitos dos fármacos , Adulto , Idoso , Complicações do Diabetes/tratamento farmacológico , Complicações do Diabetes/fisiopatologia , Implantes de Medicamento , Feminino , Humanos , Injeções Intravítreas , Edema Macular/tratamento farmacológico , Edema Macular/fisiopatologia , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...