Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Cell Infect Microbiol ; 14: 1339352, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38410721

RESUMO

Background: Monkeypox (Mpox) is a re-emerging infectious disease representing a new global challenge. It poses a substantial threat to countries, particularly those with a low number of cases. Due to its popularity as a tourist destination and its proximity to many African refugees, Egypt is potentially at risk of Mpox importation. Therefore, effective disease management necessitates healthcare workers (HCWs) to possess adept knowledge, along with a positive attitude and behavior. The study aimed to assess the knowledge, attitude, and perception of Egyptian HCWs and medical students towards human Mpox. Methods: The present cross-sectional study data was collected from participants between October and December 2022 via a questionnaire. The questionnaire comprised 31 questions in the knowledge section, 11 questions in the attitude section, and 14 in the perception section. Results: The present study involved a total of 1,034 HCWs and medical students. It was found that 55.3% of the participants demonstrated adequate knowledge about Mpox, whereas 44.5% and 39.8% of the respondents exhibited favorable attitudes and perceptions towards the disease, respectively. Binary logistic regression analysis revealed that adequate knowledge was significantly observed in ages older than 40 years (p < 0.001), married participants (p < 0.001), and doctors (p < 0.001). The positive attitude was significantly observed among the male sex (p = 0.045), urban residents (p = 0.002), and nurses (p = 0.002). Conversely, married participants (p = 0.013), doctors (p < 0.001), and individuals employed in pharmacy and laboratory departments (p < 0.001) experienced an increase in positive perception. Conclusion: Knowledge, attitude, and perception towards Mpox among Egyptian HCWs and medical students exhibit suboptimal levels. Addressing these gaps is crucial to controlling and effectively preventing disease transmission.


Assuntos
Mpox , Estudantes de Medicina , Humanos , Masculino , Estudos Transversais , Egito , Conhecimentos, Atitudes e Prática em Saúde , Pessoal de Saúde , Percepção
2.
BMC Anesthesiol ; 23(1): 417, 2023 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-38114941

RESUMO

BACKGROUND: The bispectral index (BIS) monitor is one of the EEG-derived monitoring techniques and well-established devices used to measure the depth of anesthesia. This study aimed to assess the agreement of BIS values based on the positions of either post-auricular or frontal sensors in individual patients undergoing renal surgeries while lateral positions at various stages of anesthesia. PATIENTS AND METHODS: 12 patients older than 18 years, ASA I-III patients scheduled for elective renal operations, two BIS were placed on each patient, one on each side of the post-auricular region and one across the forehead, and each sensor was connected to a different BIS monitor. We gathered three pieces of data at each of the six-time points: BIS score, signal quality index (SQI) score calculating the signal's strength and electromyography (EMG) score: before the onset of anesthesia (awake) when the eyelash reflex is lost (LOC), after intubation (intubation), following the initial surgical incision, each 30 min throughout the procedure (maintenance), and at the moment the patient's eyes open naturally after waking up from anesthesia (emergence). RESULTS: The overall BIS value at the frontal position was significantly higher than the post-auricular position (52.5 ± 22.2 and 52.1 ± 22.1, respectively, P = 0.010). On the other hand, the BIS value was comparable between the frontal and post-auricular positions at LOC, intubation, 60, 120, and 80 min and at emergence. A strong link between the two sensor positions, as indicated by the correlation coefficient (r = 0.607, P < 0.001), and the Bland-Altman analysis revealed a small mean difference (-1.8) and a low (9.0/- 12.5) limit of agreement, with just 4.3% of the readings falling outside of it during the anesthetic maintenance period. CONCLUSION: Acceptable variation in BIS data was observed when obtained from the two different sensor positions for clinical usage. The post-auricular BIS sensor system may be a suitable substitute for an impractical frontal setup. PROTOCOL REGISTRATION: The study was registered in clinicaltrials.gov on 11/07/2022 (trial registration number: NCT05451823).


Assuntos
Anestesia , Anestesiologia , Humanos , Eletroencefalografia/métodos , Monitorização Intraoperatória/métodos , Vigília , Adulto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...