1.
J Funct Biomater ; 14(7)2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37504846

RESUMO

Goose bone is traditionally applied for many ailments including bone fractures. Goose bone that consists of calcium phosphate plays a major role in bone regeneration. In this study, the production of goose bone ash (GBA) was translated from a traditional process into one of a laboratory scale via thermal and mechanical methods. The GBA was thermally processed via calcination at 300 °C and 900 °C. The differences in physicochemical properties between studied GBA (SGBA) and commercial GBA (CGBA) were elucidated via Fourier transform infrared (FT-IR), X-ray fluorescence (XRF), X-ray diffraction (XRD) and electron diffraction X-Ray (EDX). The morphological properties of SGBA and CGBA were characterized using field emission scanning electron microscopy (FESEM) in which nano-sized particles were detected. The results showed that the SGBA of 300 °C had comparable physicochemical properties to those of CGBA. A high processing temperature was associated with decreasing organic compounds and increasing crystallinity. The finding from EDX suggests that sintering at 900 °C (SGBA 900) demonstrated the presence of hydroxyapatite in the mineralogical phase and had a Ca/P atomic ratio of 1.64 which is comparable to the ideal stoichiometric ratio of 1.67. Findings from this study could be used for the further exploration of GBA as a potential material for bone regeneration via the elucidation of their biological properties in the next experimental setting.

2.
Polymers (Basel) ; 13(9)2021 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-33925332

RESUMO

Polymeric materials have always established an edge over other classes of materials due to their potential applications in various fields of biomedical engineering. Orthodontics is an emerging field in which polymers have attracted the enormous attention of researchers. In particular, thermoplastic materials have a great future utility in orthodontics, both as aligners and as retainer appliances. In recent years, the use of polycarbonate brackets and base monomers bisphenol A glycerolate dimethacrylate (bis-GMA) has been associated with the potential release of bisphenol A (BPA) in the oral environment. BPA is a toxic compound that acts as an endocrine disruptor that can affect human health. Therefore, there is a continuous search for non-BPA materials with satisfactory mechanical properties and an esthetic appearance as an alternative to polycarbonate brackets and conventional bis-GMA compounds. This study aims to review the recent developments of BPA-free monomers in the application of resin dental composites and adhesives. The most promising polymeric smart materials are also discussed for their relevance to future orthodontic applications.

3.
J Craniofac Surg ; 30(8): e720-e723, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31261343

RESUMO

PURPOSE: Decompressive craniectomy is a life-saving procedure in the setting of malignant brain swelling. Patients who survive require cranioplasty for anatomical reconstruction and cerebral protection. Autologous cranioplasty remains the commonest practice nowadays, but partial bone flap defects are frequently encountered. The authors, therefore, seek to develop a new technique of reconstruction for cranioplasty candidate with partial bone flap defect utilizing computer-assisted 3D modeling and printing. METHODS: A prospective study was conducted to evaluate the outcome of a new reconstruction technique that produces patient-specific hybrid polymethyl methacrylate-autologous cranial implant. Computer-assisted 3D modeling and printing was utilized to produce patient-specific molds, which allowed real-time reconstruction of bone flap with partial defect intra-operatively. RESULTS: Outcome assessment for 11 patients at 6 weeks and 3 months post-operatively revealed satisfactory implant alignment with favorable cosmesis. The mean visual analog scale for cosmesis was 91. Mean implant size was 50cm, and the mean duration of intra-operative reconstruction was 30 minutes. All of them revealed improvement in quality of life following surgery as measured by the SF-36 score. Cost analysis revealed that this technique is more cost-effective compared to customized cranial prosthesis. CONCLUSION: This new technique and approach produce hybrid autologous-alloplastic bone flap that resulted in satisfactory implant alignment and favorable cosmetic outcome with relatively low costs.


Assuntos
Crânio/cirurgia , Retalhos Cirúrgicos , Adolescente , Adulto , Craniectomia Descompressiva/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelagem Computacional Específica para o Paciente , Impressão Tridimensional , Estudos Prospectivos , Qualidade de Vida , Procedimentos de Cirurgia Plástica , Resultado do Tratamento , Adulto Jovem
4.
Mater Sci Eng C Mater Biol Appl ; 99: 719-725, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30889745

RESUMO

This study reports the influence of ZrO2/ß-TCP hybridization on the thermal, mechanical, and physical properties of polyamide 12 composites to be suited for bone replacement. Amount of 15 wt% of nano-ZrO2 along with 5,10,15,20 and 25 wt% of micro-ß-TCP was compounded with polyamide 12 via a twin-screw extruder. The hybrid ZrO2/ß-TCP filled polyamide 12 exhibited higher thermal, mechanical and physical properties in comparison to unfilled polyamide 12 at certain filler loading; which is attributed to the homogenous dispersion of ZrO2/ß-TCP fillers particle in polyamide 12 matrix. The hybrid ZrO2/ß-TCP filled PA 12 demonstrated an increment of tensile strength by up to 1%, tensile modulus of 38%, flexural strength of 15%, flexural modulus of 45%, and surface roughness value of 93%, as compared to unfilled PA 12. With enhanced thermal, mechanical and physical properties, the newly developed hybrid ZrO2/ß-TCP filled PA 12 could be potentially utilized for bone replacement.


Assuntos
Osso e Ossos/fisiologia , Cerâmica/química , Fenômenos Mecânicos , Nylons/química , Temperatura , Engenharia Tecidual/métodos , Fosfatos de Cálcio/química , Espectroscopia de Infravermelho com Transformada de Fourier , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração , Termogravimetria , Zircônio/química
5.
Dent Mater ; 34(11): e309-e316, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30268678

RESUMO

OBJECTIVE: To compare the mechanical and biological properties of newly developed hybrid ceramics filled and unfilled polyamide 12 (PA 12) for craniofacial reconstruction via a fused deposition modelling (FDM) framework. METHODS: 15wt% of zirconia (ZrO2) as well as 30, 35, and 40wt% of beta-tricalcium phosphate (ß-TCP) were compounded with PA 12, followed by the fabrication of filament feedstocks using a single screw extruder. The fabricated filament feedstocks were used to print the impact specimens. The melt flow rate, tensile properties of fabricated filament feedstocks, and 3D printed impact properties of the specimens were assessed using melt flow indexer, universal testing machine, and Izod pendulum tester, respectively. The microstructure of selected filament feedstocks and broken impact specimens were analysed using a field emission scanning electron microscope and universal testing machine. Human periodontal ligament fibroblast cells (HPdLF) were used to evaluate the cytotoxicity of the materials by (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazoliumbromid) (MTT) assay. RESULTS: Hybrid ceramics filled PA 12 indicated sufficient flowability for FDM 3D printing. The tensile strength of hybrid ceramics filled PA 12 filament feedstocks slightly reduced as compared to unfilled PA 12. However, the tensile modulus and impact strength of hybrid ceramics filled PA 12 increased by 8%-31% and 98%-181%, respectively. A significant increase was also detected in the cell viability of the developed composites at concentrations of 12.5, 25, 50 and 100mg/ml. SIGNIFICANCE: The newly developed hybrid ceramics filled PA 12 filament feedstock with improved properties is suitable for an FDM-based 3D printer, which enables the creation of patient-specific craniofacial implant at a lower cost to serve low-income patients.


Assuntos
Cerâmica/química , Fibroblastos/efeitos dos fármacos , Prótese Maxilofacial , Nylons/química , Desenho de Prótese/métodos , Fosfatos de Cálcio/química , Fosfatos de Cálcio/toxicidade , Cerâmica/toxicidade , Humanos , Técnicas In Vitro , Nylons/toxicidade , Ligamento Periodontal/citologia , Impressão Tridimensional , Resistência à Tração , Zircônio/química , Zircônio/toxicidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...