Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Environ Sci Pollut Res Int ; 30(54): 114956-114984, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37878171

RESUMO

It has become of utmost importance to preserve marine life and human health by protecting aquatic environments from contaminants. Therefore, using photocatalytic materials in treatment of contaminated water is a promising and innovative technique. Novel double perovskite Sm2CeMnO6 was synthesized through a modified Pechini sol-gel method. Also, urea and melamine were utilized to synthesize graphitic carbon nitride (g-C3N4). Combination of Sm2CeMnO6 and g-C3N4 produced several S-scheme heterojunction materials in diverse components ratios. Average crystallite sizes of Sm2CeMnO6 and Sm2CeMnO6/g-C3N4 (20:80) samples were calculated by Debye-Scherrer and Williamson-Hall methods to be 19.77, 22.72 nm and 42.01, 43.73 nm, respectively. The coexistence of g-C3N4 (002) with a d-spacing of 0.325 nm and Sm2CeMnO6 planes of (222), (111), and (400) with spacing values of 0.314, 0.302, and 0.294 nm, respectively, was depicted in the HR-TEM image of the Sm2CeMnO6/g-C3N4 (20:80). The estimated bandgaps for the g-C3N4, Sm2CeMnO6, and Sm2CeMnO6/g-C3N4 (20:80) were 2.70, 2.60, and 2.65 eV, respectively. Their application was investigated in photocatalytic degradation of methylene blue (MB) dye as typical pollutant. The estimated degradation pathway of MB was also provided through LC-MS analysis. Under the identical conditions, the best photocatalytic performance was found for Sm2CeMnO6/g-C3N4 (20:80) composite. Using response surface methodology (RSM), operational parameters of the photocatalytic degradation were modeled and optimized by the best composite through central composite design approach. Applying optimized parameters led to 96% degradation of MB (8 mg/L) at pH 10 under 120 min visible light irradiation (λ > 365 nm) using 0.15 g of Sm2CeMnO6/g-C3N4 (20:80) composite in 100 mL aqueous solution. Due to low intrinsic charge transfer resistance, modified Eg, and good performance in e‒/h+ pairs production, Sm2CeMnO6/g-C3N4 (20:80) nanocomposite was introduced as a promising S-scheme photocatalyst.


Assuntos
Poluentes Ambientais , Óxidos , Humanos , Compostos de Cálcio , Cromatografia Líquida , Azul de Metileno
2.
RSC Adv ; 13(22): 14825-14840, 2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-37197189

RESUMO

To achieve high-performance dye-sensitized solar cells (DSSCs), it is essential to establish new and effective photoelectrode materials. Herein, we report the successful synthesis of heterojunctions including Cu-based delafossite oxide CuCoO2 and ZnO derived from zeolitic imidazolate framework-8 (ZIF-8). The layered polyhedral nanocrystals of CuCoO2 produced through a feasible low temperature hydrothermal process and the faceted nanocrystals of ZnO were achieved by heat treatment of ZIF-8. The composite heterostructures were applied as photoelectrodes in DSSCs assembled using dye N719 and a Pt counter electrode. The physicochemical characteristics (XRD, FESEM, EDAX, mapping, BET, DRS), dye loading, and photovoltaic properties (J-V, EIS, IPCE) of the fabricated materials were studied and fully discussed. Results revealed that addition of CuCoO2 to ZnO significantly improved the Voc, Jsc, PCE, FF, and IPCE. Among all cells, CuCoO2/ZnO (0.1 : 1) showed the best performance (PCE = 6.27%, Jsc = 14.56 mA cm-2, Voc = 687.84 mV, FF = 62.67%, IPCE = 45.22%) and acted as a promising photoanode in DSSCs.

3.
Rev Sci Instrum ; 80(12): 123303, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20059136

RESUMO

A new particle sizer which integrates the dispersion and detection parts is presented. Particles are dispersed based on charging between two parallel plates connected to a high voltage power source. The charged particles bounce between the two plates and escape into a measuring area where the size is determined by light scattering. The instrument is calibrated using standard powders. The data obtained from the new instrument are in good agreement with those obtained from a commercial particle size analyzer. The sizer works both for insulator and conductive powders.


Assuntos
Equipamentos e Provisões Elétricas , Tamanho da Partícula , Óxido de Alumínio/química , Calibragem , Desenho de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...