Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Virol ; 2024: 2993144, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38584794

RESUMO

Introduction: Currently, sequencing has been the only tool for the identification of circulating severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) variants. However, it is known to be an expensive and laborious approach involving high technical expertise. Considering the reduced adherence to preventive measures postlockdown in Accra, this study presents an alternative method that leverages polymerase chain reaction (PCR) to identify circulating SARS-CoV-2 variants in the Accra Metropolis postlockdown. Methods: This prospective cross-sectional study was conducted between July and December 2022. Nasopharyngeal samples were collected from 268 consenting participants. Samples were subjected to nucleic acid extraction and followed by real-time polymerase chain reaction for the detection and quantification of SARS-CoV-2 RNA. SARS-CoV-2 positive samples were subsequently subjected to variant identification using rapid PCR. Findings. The prevalence of SARS-CoV-2 within the Accra Metropolis was 30.2%. The majority of the SARS-CoV-2 infection was diagnosed in females, participants aged 41-50 years, and symptomatic participants. Participants aged ≤10 years and females recorded the highest viral load while participants aged 41-50 years recorded the highest number of infections. The SARS-CoV-2 variants detected were Alpha (64.2%), Delta (22.2%), and Omicron (13.6%). Predictors of SARS-CoV-2 infection identified were chills, cough, headache, body weakness, sore throat, and dyspnoea in order of decreasing association with SARS-CoV-2 infection. There was a strong association between symptom status, gender, age, and SARS-CoV-2 infection. Conclusion: There was a high prevalence of SARS-CoV-2 within the Accra Metropolis postlockdown within the sampling period. The Alpha variant of SARS-CoV-2 is the predominant circulating variant, and persons presenting with symptoms are most likely to be diagnosed with COVID-19. Children aged ≤10 years serve as a reservoir for infection transmission.

2.
Microbiol Spectr ; : e0007324, 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38683014

RESUMO

The COVID-19 pandemic has highlighted the critical need for accurate and efficient diagnostic tools for detecting severe acute respiratory coronavirus 2 (SARS-CoV-2) infections. This study presents a comparison of two diagnostic tests: RT-PCR and antigen detection rapid diagnostic tests (Ag-RDTs). This study focused on their performance, variant specificity, and their clinical implications. A simultaneous testing of 268 samples was carried out for SARS-CoV-2 using RT-PCR and Ag-RDTs [flourescence immunoassay (FIA) and lateral flow immunoassay (LFIA)]. Viral load was quantified, and variant identification was performed using a PCR-based assay. The prevalence was found to be 30.2% using reverse transcription PCR (RT-PCR), 26.5% using FIA, and 25% using LFIA. When comparing the FIA and LFIA, the overall diagnostic performance was found to be 80.25% vs 76.54%, 96.79% vs 97.33%, 91.55% vs 90.51%, and 91.88% vs 92.56% for sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), respectively. Both Ag-RDTs showed a strong agreement with RT-PCR (κ = 0.78-0.80). The overall accuracies of the FIA and LFIA were 92.41% and 92.13%, respectively. The FIA showed higher sensitivity (73.68%) and PPV (92.08%) than the LFIA (65.79% and 90.56%, respectively) in asymptomatic patients. At low Ct values (<25), both Ag-RDTs had 100% sensitivity, but the sensitivity reduced to 31.82% for FIA and 27.27% for LFIA at Ct values > 30. The diagnostic sensitivity of FIA compared to LFIA for detecting the Alpha variant was 78.85% vs. 69.23% and 72.22% vs. 83.33% for the Delta variant. Both Ag-RDTs had 100% sensitivity for detecting Omicron. Both Ag-RDTs performed well in patients with high viral loads and Omicron variant infections compared to those infected with Alpha and Delta variants. This study confirms the comparable performance of RT-PCR and Ag-RDTs, specifically FIA and LFIA, for SARS-CoV-2 detection. The FIA showed higher sensitivity and PPV in asymptomatic cases, while both Ag-RDTs exhibited strong agreement with RT-PCR results. Notably, Ag-RDTs, particularly FIA, proved effective in detecting the Omicron variant and cases with high viral loads, highlighting their potential clinical utility in managing the COVID-19 pandemic.IMPORTANCEThis study is of utmost importance in providing effective responses to manage the COVID-19 pandemic. It rigorously compares the diagnostic accuracy, variant specificity, and practical considerations of reverse transcription PCR (RT-PCR) and antigen detection rapid diagnostic tests (Ag-RDTs) for severe acute respiratory coronavirus 2 (SARS-CoV-2), answering critical questions. The results of this study will help healthcare professionals choose the appropriate testing methods, allocate resources effectively, and enhance public health strategies. Given the evolution of the virus, understanding the performance of these diagnostic tools is crucial to adapting to emerging variants. Additionally, the study provides insights into logistical challenges and accessibility issues, which will contribute to refining testing workflows, particularly in resource-limited settings. Ultimately, the study's impact extends to global healthcare, providing valuable information for policymakers, clinicians, and public health officials as they work together for mitigating the impact of the pandemic.

3.
PLoS Negl Trop Dis ; 15(6): e0009512, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34157020

RESUMO

BACKGROUND: Simulium damnosum sensu lato (s.l.) blackflies transmit Onchocerca volvulus, a filarial nematode that causes human onchocerciasis. Human landing catches (HLCs) is currently the sole method used to estimate blackfly biting rates but is labour-intensive and questionable on ethical grounds. A potential alternative is to measure host antibodies to vector saliva deposited during bloodfeeding. In this study, immunoassays to quantify human antibody responses to S. damnosum s.l. saliva were developed, and the salivary proteome of S. damnosum s.l. was investigated. METHODOLOGY/PRINCIPAL FINDINGS: Blood samples from people living in onchocerciasis-endemic areas in Ghana were collected during the wet season; samples from people living in Accra, a blackfly-free area, were considered negative controls and compared to samples from blackfly-free locations in Sudan. Blackflies were collected by HLCs and dissected to extract their salivary glands. An ELISA measuring anti-S. damnosum s.l. salivary IgG and IgM was optimized and used to quantify the humoral immune response of 958 individuals. Both immunoassays differentiated negative controls from endemic participants. Salivary proteins were separated by gel-electrophoresis, and antigenic proteins visualized by immunoblot. Liquid chromatography mass spectrometry (LC-MS/MS) was performed to characterize the proteome of S. damnosum s.l. salivary glands. Several antigenic proteins were recognized, with the major ones located around 15 and 40 kDa. LC-MS/MS identified the presence of antigen 5-related protein, apyrase/nucleotidase, and hyaluronidase. CONCLUSIONS/SIGNIFICANCE: This study validated for the first time human immunoassays that quantify humoral immune responses as potential markers of exposure to blackfly bites. These assays have the potential to facilitate understanding patterns of exposure as well as evaluating the impact of vector control on biting rates. Future studies need to investigate seasonal fluctuations of these antibody responses, potential cross-reactions with other bloodsucking arthropods, and thoroughly identify the most immunogenic proteins.


Assuntos
Mordeduras e Picadas de Insetos/epidemiologia , Insetos Vetores/fisiologia , Saliva , Simuliidae/fisiologia , Adolescente , Adulto , Idoso , Animais , Criança , Pré-Escolar , Ensaio de Imunoadsorção Enzimática , Feminino , Gana , Humanos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Mordeduras e Picadas de Insetos/imunologia , Masculino , Pessoa de Meia-Idade , Oncocercose , Sudão
4.
BMC Infect Dis ; 20(1): 301, 2020 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-32321418

RESUMO

BACKGROUND: In Ghana, pre-school-aged children (PSAC) are at risk of intestinal schistosomiasis and are living in need of praziquantel treatment. To better assess the infection burden within this vulnerable demographic group, we have provided a comparative assessment of the prevalence of Schistosoma mansoni in pre-school-aged children by urine circulating cathodic antigen (CCA) dipsticks, real-time PCR Taqman® faecal assays and Kato-Katz coproscopy. METHODS: In all, 190 pre-school-aged children were sampled from three endemic communities (viz. Tomefa, Torgahkope/Adakope, and Manheam) around Weija dam, Southern Ghana. Fresh stool and urine samples were collected from all participants for diagnosis. RESULTS: Among all the three communities, the urine-CCA assay recorded the highest prevalence values of 90.5% (95% CI 80.4-96.4), 87.9% (95% CI 76.7-95), and 81.2% (95% CI 69.9-89.6) in Tomefa, Torgahkope/Adakope, and Manheam respectively. Prevalence by real-time PCR was 50% (95% CI 35.5-64.5), 8% (95% CI 2.2-19.2) and 16.7% (95% CI 8.3-28.5), while by Kato-Katz was 55.6% (95% CI 42.5-68.1), 8.6% (95% CI 2.9-19) and 11.6% (95% CI 5.1-21.6) respectively. Children aged 1 year and over were found to be positive with the urine-CCA assay; by the ages of 3-4, over 50% were urine-CCA patent. The sensitivity and specificity of the POC-CCA dipsticks, when compared against the combined results of Kato-Katz/TaqMan results was found to be 84.1% (95% CI = 72.7-92.1) and 12.9% (95% CI = 6.6-22) respectively. CONCLUSIONS: We propose that the urine-CCA dipstick may be a useful rapid diagnostic tool to estimate the prevalence of intestinal schistosomiasis in PSAC, particularly in rapid identification of at-risk areas. However, our assessment has shown that it possible to record false positives when compared to combined Kato-Katz and qPCR results. To guide PSAC praziquantel treatment needs, we propose the urine CCA assay should be included in routine surveillance of intestinal schistosomiasis alongside other diagnostics such as Kato-Katz and urine filtration.


Assuntos
Antígenos de Helmintos/urina , Testes Diagnósticos de Rotina/métodos , Fezes/parasitologia , Reação em Cadeia da Polimerase em Tempo Real/métodos , Esquistossomose mansoni/diagnóstico , Urinálise/métodos , Animais , Antígenos de Helmintos/análise , Bioensaio/métodos , Líquidos Corporais/química , Líquidos Corporais/imunologia , Líquidos Corporais/parasitologia , Pré-Escolar , Fezes/química , Feminino , Gana/epidemiologia , Humanos , Lactente , Masculino , Sistemas Automatizados de Assistência Junto ao Leito , Praziquantel/uso terapêutico , Prevalência , Schistosoma mansoni/genética , Schistosoma mansoni/imunologia , Schistosoma mansoni/isolamento & purificação , Esquistossomose mansoni/tratamento farmacológico , Esquistossomose mansoni/parasitologia , Esquistossomose mansoni/urina , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...