Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Inflamm Bowel Dis ; 28(9): 1348-1356, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34849918

RESUMO

BACKGROUND: Etrolizumab, a humanized anti-ß7 antibody, has not been studied in children. Here, we evaluate the pharmacokinetics, pharmacodynamics, and safety of etrolizumab in children with inflammatory bowel disease. METHODS: Patients age 4 to 17 years with moderately to severely active ulcerative colitis or Crohn's disease were randomized 1:1 to receive 1.5mg/kg of etrolizumab subcutaneously every 4 weeks (q4w) or 3.0mg/kg every 8 weeks (q8w) for 16 weeks in this open-label phase 1 trial. Pharmacokinetics, pharmacodynamics, safety, and efficacy were assessed. RESULTS: Of the 24 patients treated, 21 completed the study. In the groups of 1.5mg/kg q4w and 3.0mg/kg q8w, respectively, mean (SD) maximum concentration (Cmax) was 9.8 (4.86) µg/mL and 18.1 (6.25) µg/mL; and mean (SD) area under the curve within a dosing interval (AUCtau) was 167 (86.9) and 521 (306) µg·day/mL after the last dose. The Cmax increased dose proportionally. The AUC over an 8-week period was slightly higher in the 3.0mg/kg q8w dose group. Median half-life was similar for both dosing regimens. Median numbers of free ß7high gut-homing T and B cell subsets declined below 10% of baseline, confirming ß7 target engagement and complete/near-complete receptor occupancy. Adverse events were consistent with the safety profile in adults. Approximately 60% of patients achieved a clinical response. CONCLUSIONS: Etrolizumab showed a dose-proportional increase in Cmax and a slightly greater than dose-proportional increase in AUCtau. Both regimens achieved complete/near-complete ß7 receptor occupancy, with a similar relationship to concentration as adults. Etrolizumab was well tolerated and demonstrated clinical activity in children.


Assuntos
Colite Ulcerativa , Doença de Crohn , Doenças Inflamatórias Intestinais , Adolescente , Adulto , Anticorpos Monoclonais Humanizados , Criança , Pré-Escolar , Colite Ulcerativa/tratamento farmacológico , Doença de Crohn/tratamento farmacológico , Humanos , Doenças Inflamatórias Intestinais/tratamento farmacológico
3.
Adv Ther ; 38(5): 2406-2417, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33778928

RESUMO

INTRODUCTION: Etrolizumab is a novel, dual-action, anti-ß7 integrin antibody in development for patients with moderate to severe ulcerative colitis or Crohn's disease. Phase 3 studies use a prefilled syringe (PFS) for etrolizumab administration. In parallel, an autoinjector (AI) is being developed to increase delivery options for patients if etrolizumab is approved. Here we describe the overall development strategy and detail the first-in-human study of this AI. METHODS: This open-label study of healthy volunteers evaluated the tolerability and usability of the etrolizumab AI under development. The primary endpoint was the proportion of participants with greater than mild pain following injection. Adverse events (AEs) and usage errors were also assessed. Results were reported by injection site (thigh vs abdomen) and needle training (experienced vs naive). Pharmacokinetic (PK) variability between participants was an exploratory endpoint. RESULTS: Thirty participants completed the study; 97% of them did not experience any pain greater than mild, and 50% did not experience any pain at all. Three usage errors were observed, one of which resulted in delivery of a partial dose of etrolizumab. No patterns of usage errors were observed. Mild injection site reactions (ISRs) were reported; all resolved by the end of the study. Participants injecting into the abdomen reported more ISRs than those injecting into the thigh; needle training did not influence AE incidence or severity. CONCLUSIONS: Results from this first-in-human study demonstrate that single injections of etrolizumab 105 mg using an AI were well tolerated in healthy volunteers, with transient, mild pain and minimal usage errors. Results from this study also informed the design of a subsequent PK comparability study evaluating exposure of etrolizumab administered by either the PFS or the AI. Overall, the availability of an AI may provide an attractive option for patients desiring a convenient, easy-to-use delivery mechanism for etrolizumab. TRIAL REGISTRATION: NCT02629744.


Assuntos
Colite Ulcerativa , Doença de Crohn , Anticorpos Monoclonais Humanizados , Voluntários Saudáveis , Humanos
4.
Adv Ther ; 38(5): 2418-2434, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33778929

RESUMO

INTRODUCTION: Etrolizumab is a novel, dual-action anti-ß7 integrin antibody studied in phase 3 trials in patients with inflammatory bowel disease. An autoinjector (AI) is being developed in parallel to complement the prefilled syringe with needle safety device (PFS-NSD) for subcutaneous (SC) administration in these trials. Here we demonstrate the comparable pharmacokinetics, tolerability, and safety of both devices. METHODS: This randomized, open-label, two-part study in healthy participants evaluated the comparability of etrolizumab exposure between the AI and the PFS-NSD. Part 1 (pilot) involved a small number of participants, and initial results were used to finalize the design of the larger part 2 (pivotal) study. In both parts, participants were randomly assigned to receive a single SC dose of etrolizumab 105 mg by AI or PFS-NSD. Randomization was stratified by body weight. Primary pharmacokinetic outcomes were Cmax, AUClast, and AUC0-inf. RESULTS: One hundred and eighty healthy participants (part 1, n = 30; part 2, n = 150) received a single SC dose of etrolizumab by AI or PFS-NSD. Primary pharmacokinetic results from part 1 supported modification of the part 2 study design. Results from part 2 demonstrated that etrolizumab exposure was equivalent between devices, with geometric mean ratios (GMRs) between AI and PFS-NSD of 102% (90% confidence interval [CI] 94.2-111) for Cmax, 98.0% (90% CI 89.3-107) for AUClast, and 97.6% (90% CI 88.6-107) for AUC0-inf. Median tmax and mean terminal t1/2 were also similar between devices. GMRs and 90% CIs of all primary pharmacokinetic parameters were fully contained within the predefined equivalence limits (80-125%). CONCLUSION: This pharmacokinetic study demonstrated that single SC injections of etrolizumab 105 mg using an AI or a PFS-NSD resulted in equivalent etrolizumab exposure and similar safety and tolerability in healthy participants. Taken together, these results support the use of an AI for etrolizumab administration. TRIAL REGISTRATION: NCT02996019.


Assuntos
Anticorpos Monoclonais Humanizados , Seringas , Voluntários Saudáveis , Humanos , Injeções Subcutâneas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...