Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Transplant Proc ; 53(5): 1665-1669, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34020795

RESUMO

BACKGROUND: Liver transplantation is a complex surgical procedure. The experience of the anesthesiologist, and its potential relationship to patient morbidity and mortality, is yet to be determined. We sought to explore this possible association using our institutional training patterns as the subject of study. METHODS: This is a single center retrospective analysis investigating the association of an anesthesiologist's experience with liver transplantation and its potential effect on early patient outcomes in adult liver transplant recipients from January 2010 to September 2016. Training of team members consisted of a 6-month period of clinical shadowing with a senior anesthesiologist and co-staffing 8 liver transplant procedures before solo staffing a liver transplant. Specifically, patient outcomes for the first 5 transplants after this training were investigated. RESULTS: The only independent risk factor for early death or early graft loss was the amount of packed red blood cells administered during transplantation. With respect to secondary outcomes, the amount of packed red blood cells and hospitalization at the time of transplant were associated with the number of days on a ventilator, length of intensive care unit stay, and overall hospital length of stay. CONCLUSIONS: The results of this study conclude that the training model currently in place for our new team members has no negative impact on patient outcomes after liver transplantation.


Assuntos
Anestesiologistas/estatística & dados numéricos , Doença Hepática Terminal/cirurgia , Transplante de Fígado , Transfusão de Eritrócitos , Feminino , Rejeição de Enxerto/mortalidade , Humanos , Unidades de Terapia Intensiva , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Razão de Chances , Estudos Retrospectivos , Resultado do Tratamento , Ventiladores Mecânicos
2.
Eur J Radiol ; 86: 163-168, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28027742

RESUMO

PURPOSE: To determine which left atrial (LA) and left ventricular (LV) parameters are associated with future major adverse cardiac event (MACE) and whether these measurements have independent prognostic value beyond risk factors and computed tomography (CT)-derived coronary artery disease measures. MATERIALS AND METHODS: This retrospective analysis was performed under an IRB waiver and in HIPAA compliance. Subjects underwent coronary CT angiography (CCTA) using a dual-source CT system for acute chest pain evaluation. LV mass, LV ejection fraction (EF), LV end-systolic volume (ESV) and LV end-diastolic volume (EDV), LA ESV and LA diameter, septal wall thickness and cardiac chamber diameters were measured. MACE was defined as cardiac death, non-fatal myocardial infarction, unstable angina, or late revascularization. The association between cardiac CT measures and the occurrence of MACE was quantified using Cox proportional hazard analysis. RESULTS: 225 subjects (age, 56.2±11.2; 140 males) were analyzed, of whom 42 (18.7%) experienced a MACE during a median follow-up of 13 months. LA diameter (HR:1.07, 95%CI:1.01-1.13permm) and LV mass (HR:1.05, 95%CI:1.00-1.10perg) remained significant prognostic factor of MACE after controlling for Framingham risk score. LA diameter and LV mass were also found to have prognostic value independent of each other. The other morphologic and functional cardiac measures were no significant prognostic factors for MACE. CONCLUSION: CT-derived LA diameter and LV mass are associated with future MACE in patients undergoing evaluation for chest pain, and portend independent prognostic value beyond traditional risk factors, coronary calcium score, and obstructive coronary artery disease.


Assuntos
Dor no Peito/diagnóstico por imagem , Dor Aguda/diagnóstico por imagem , Dor Aguda/patologia , Angina Instável/diagnóstico por imagem , Angina Instável/patologia , Dor no Peito/patologia , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/complicações , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Tamanho do Órgão , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Tomografia Computadorizada por Raios X/métodos , Função Ventricular Esquerda/fisiologia
3.
Am J Cardiol ; 117(3): 333-9, 2016 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-26739395

RESUMO

Blacks have higher mortality and hospitalization rates because of congestive heart failure compared with white counterparts. Differences in cardiac structure and function may contribute to the racial disparity in cardiovascular outcomes. Our aim was to compare computed tomography (CT)-derived cardiac measurements between black patients with acute chest pain and age- and gender-matched white patients. We performed a retrospective analysis under an institutional review board waiver and in Health Insurance Portability and Accountability Act compliance. We investigated patients who underwent cardiac dual-source CT for acute chest pain. Myocardial mass, left ventricular (LV) ejection fraction, LV end-systolic volume, and LV end-diastolic volume were quantified using an automated analysis algorithm. Septal wall thickness and cardiac chamber diameters were manually measured. Measurements were compared by independent t test and linear regression. The study population consisted of 300 patients (150 black-mean age 54 ± 12 years; 46% men; 150 white-mean age 55 ± 11 years; 46% men). Myocardial mass was larger for blacks compared with white (176.1 ± 58.4 vs 155.9 ± 51.7 g, p = 0.002), which remained significant after adjusting for age, gender, body mass index, and hypertension. Septal wall thickness was slightly greater (11.9 ± 2.7 vs 11.2 ± 3.1 mm, p = 0.036). The LV inner diameter was moderately larger in black patients in systole (32.3 ± 9.0 vs 30.1 ± 5.4 ml, p = 0.010) and in diastole (50.1 ± 7.8 vs 48.9 ± 5.2 ml, p = 0.137), as well as LV end-diastolic volume (134.5 ± 42.7 vs 128.2 ± 30.6 ml, p = 0.143). Ejection fraction was nonsignificantly lower in blacks (67.1 ± 13.5% vs 69.0 ± 9.6%, p = 0.169). In conclusion, CT-derived myocardial mass was larger in blacks compared with whites, whereas LV functional parameters were generally not statistically different, suggesting that LV mass might be a possible contributing factor to the higher rate of cardiac events in blacks.


Assuntos
População Negra , Dor no Peito/diagnóstico por imagem , Angiografia Coronária/métodos , Ventrículos do Coração/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Contração Miocárdica/fisiologia , População Branca , Doença Aguda , Dor no Peito/etnologia , Dor no Peito/fisiopatologia , Eletrocardiografia , Feminino , Seguimentos , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Volume Sistólico/fisiologia , Estados Unidos/epidemiologia
4.
Clin Cardiol ; 35(10): 641-5, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22949086

RESUMO

BACKGROUND: Coronary artery atherosclerosis has been associated with obstructive sleep apnea (OSA). However, the type and severity of plaque formation have not been characterized. This study evaluated the association of coronary noncalcified plaques and severity of stenosis in patients with OSA. METHODS: This study was a retrospective analysis of 81 patients, 49 with OSA and 32 without OSA, who had undergone multidetector-row helical computed tomography scanning. The board-certified radiologist was blinded to the diagnosis of OSA and reviewed the scans for plaque characterization, severity of stenosis, and number of vessels involved. RESULTS: Of the 81 patients reviewed, the mean apnea-hypopnea index in the OSA group was 42.2 vs 7.5 in the non-OSA group. The groups did not significantly differ in the distribution of comorbid conditions. We found that among the patients with OSA, 63% had noncalcified/mixed plaques, as opposed to 16% in the non-OSA group (P < 0.0001), with unadjusted odds ratio of 9.3 (3.0, 28.4). After adjustment for other risk factors such as age, sex, race, hypercholesterolemia, and history of smoking, the association remained strong, with an odds ratio of 7.0 (1.9, 26.5; P < 0.05). CONCLUSIONS: Our study finds that the frequency of noncalcified/mixed plaques is much higher in patients with OSA than in non-OSA patients. Patients with OSA also have more severe stenosis and a higher number of vessels involved. This study adds to a growing body of data regarding our understanding of the association of OSA and atherosclerosis.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/patologia , Apneia Obstrutiva do Sono/patologia , Tomografia Computadorizada por Raios X , Intervalos de Confiança , Doença da Artéria Coronariana/epidemiologia , Feminino , Indicadores Básicos de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Polissonografia , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Apneia Obstrutiva do Sono/epidemiologia , Estados Unidos/epidemiologia
5.
JACC Cardiovasc Imaging ; 4(8): 841-9, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21835376

RESUMO

OBJECTIVES: The purpose of this study was to compare the prognostic role of various computed tomography (CT) signs of right ventricular (RV) dysfunction, including 3-dimensional ventricular volume measurements, to predict adverse outcomes in patients with acute pulmonary embolism (PE). BACKGROUND: Three-dimensional ventricular volume measurements based on chest CT have become feasible for routine clinical application; however, their prognostic role in patients with acute PE has not been assessed. METHODS: We evaluated 260 patients with acute PE for the following CT signs of RV dysfunction obtained on routine chest CT: abnormal position of the interventricular septum, inferior vena cava contrast reflux, right ventricle diameter (RVD) to left ventricle diameter (LVD) ratio on axial sections and 4-chamber (4-CH) views, and 3-dimensional right ventricle volume (RVV) to left ventricle volume (LVV) ratio. Comorbidities and fatal and nonfatal adverse outcomes according to the MAPPET-3 (Management Strategies and Prognosis in Pulmonary Embolism Trial-3) criteria within 30 days were recorded. RESULTS: Fifty-seven patients (21.9%) had adverse outcomes, including 20 patients (7.7%) who died within 30 days. An RVD(axial)/LVD(axial) ratio >1.0 was not predictive for adverse outcomes. On multivariate analysis (adjusting for comorbidities), abnormal position of the interventricular septum (hazard ratio [HR]: 2.07; p = 0.007), inferior vena cava contrast reflux (HR: 2.57; p = 0.001), RVD(4-CH)/LVD(4-CH) ratio >1.0 (HR: 2.51; p = 0.009), and RVV/LVV ratio >1.2 (HR: 4.04; p < 0.001) were predictive of adverse outcomes, whereas RVD(4-CH)/LVD(4-CH) ratio >1.0 (HR: 3.68; p = 0.039) and RVV/LVV ratio >1.2 (HR: 6.49; p = 0.005) were predictive of 30-day death. CONCLUSIONS: Three-dimensional ventricular volume measurement on chest CT is a predictor of early death in patients with acute PE, independent of clinical risk factors and comorbidities. Abnormal position of the interventricular septum, inferior vena cava contrast reflux, and RVD(4-CH)/LVD(4-CH) ratio are predictive of adverse outcomes, whereas RVD(axial)/LVD(axial) ratio >1.0 is not.


Assuntos
Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Disfunção Ventricular Direita/diagnóstico por imagem , Função Ventricular Direita , Doença Aguda , Adulto , Idoso , Distribuição de Qui-Quadrado , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Variações Dependentes do Observador , Valor Preditivo dos Testes , Prognóstico , Modelos de Riscos Proporcionais , Embolia Pulmonar/mortalidade , Embolia Pulmonar/fisiopatologia , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Disfunção Ventricular Direita/mortalidade , Disfunção Ventricular Direita/fisiopatologia
6.
Radiology ; 260(2): 373-80, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21712470

RESUMO

PURPOSE: To use coronary computed tomographic (CT) angiography to compare the prevalence, extent, and composition of coronary atherosclerotic lesions in African American and white patients with acute chest pain. MATERIALS AND METHODS: The institutional review board waived the requirement for informed consent for this retrospective, HIPAA-compliant matched-cohort study. The authors analyzed the CT angiographic data of 301 patients (150 consecutive African American patients; 151 white control patients; mean age, 55 years ± 11 [standard deviation]; 33% male) with acute chest pain. Each coronary artery segment was evaluated for presence of atherosclerotic plaque, plaque composition (calcified, noncalcified, or mixed), and stenosis. In addition, the noncalcified plaque volume was quantified by using a threshold-based automated algorithm. The presence and extent of atherosclerotic plaque were compared between the groups by using univariate and multivariate regression analyses. RESULTS: While there was no significant difference between the African American and white patients with respect to presence of any plaque (118 [79%] of 150 vs 112 [74%] of 151 patients, respectively; P = .36) or presence of stenosis (26 [17%] vs 37 [24%] patients, respectively; P = .13), the African American patients had a significantly higher prevalence (96 [64%] vs 62 [41%] patients, respectively; P < .001) and volume (median volume, 2.2 vs 1.4 mL, respectively; P < .001) of noncalcified plaque, independent of diabetes and other cardiovascular risk factors (odds ratio, 2.45; 95% confidence interval: 1.52, 4.04). In contrast, the African American patients had a lower prevalence of calcified plaque (39 [26%] vs 68 [45%] white patients, P = .001). CONCLUSION: Study results suggest that atherosclerotic plaque burden and composition, as measured by using coronary CT angiography, differ between African American and white patients, with relatively more noncalcified disease in African Americans and more calcified disease in white individuals. Further research is warranted to determine whether CT plaque characterization can improve cardiac risk prediction in African Americans.


Assuntos
Negro ou Afro-Americano/estatística & dados numéricos , Dor no Peito/diagnóstico por imagem , Dor no Peito/etnologia , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/etnologia , Tomografia Computadorizada por Raios X , População Branca/estatística & dados numéricos , Doença Aguda , Distribuição de Qui-Quadrado , Meios de Contraste , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Prevalência , Interpretação de Imagem Radiográfica Assistida por Computador , Análise de Regressão , Estudos Retrospectivos , Fatores de Risco , Estatísticas não Paramétricas
7.
Eur Radiol ; 21(9): 1895-903, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21533864

RESUMO

OBJECTIVE: To prospectively compare the accuracy of coronary CT angiography (CCTA) and conventional coronary angiography (CCA) for stenosis detection using composite findings from both tests as an enhanced reference standard. METHODS: One hundred thirteen patients underwent CCTA and CCA. Per-segment and per-patient accuracy of CCTA compared with initial CCA interpretation were determined. Angiographers were then unblinded to the CCTA results and re-evaluation of the CCA studies was performed with knowledge of CCTA findings, which was used as an enhanced reference standard to compare the diagnostic accuracy of CCTA versus CCA. RESULTS: When using the enhanced reference standard instead of initial CCA interpretation, CCTA accuracy for identifying segments (patients) with ≥50% stenosis increased from 97.7% (96.5%) to 98.1% (98.2%), sensitivity from 90.5% (100%) to 90.8% (100%), and specificity from 98.4% (94.3%) to 98.9% (97.1%). CCTA identified six segments and two patients with stenoses ≥50% missed on initial CCA interpretation. Compared with the enhanced reference standard the accuracies of CCTA and of initial CCA interpretation were not different (p = 0.87). CONCLUSION: CCTA compares favourably with CCA for stenosis detection. Use of a composite reference standard combining findings from both tests can control for the effect of false-negative CCA results when evaluating the accuracy of CCTA.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Meios de Contraste , Estenose Coronária/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Padrões de Referência , Sensibilidade e Especificidade , Índice de Gravidade de Doença
8.
AJR Am J Roentgenol ; 196(5): W550-7, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21512044

RESUMO

OBJECTIVE: The purpose of this study was to assess the radiation doses of different coronary CTA (CTA) protocols: second-generation dual-source 128-MDCT, first-generation dual-source 64-MDCT, and single-source 64-MDCT. MATERIALS AND METHODS: Thermoluminescent dosimetry was used to determine scanner-specific dose coefficients for standard coronary CTA of an anthropomorphic phantom. These coefficients were used to estimate the effective doses (EDs) of retrospectively gated, prospectively triggered, and prospectively triggered high pitch coronary CTA performed at 100 and 120 kV. The coronary CTA protocols used in imaging of 43 patients undergoing dual-source 128-MDCT were analyzed for ED, image quality, and signal-to-noise ratio. RESULTS: Regardless of coronary CTA protocol and CT system, imaging at 100 kV lowered the ED 40-50%. In retrospectively gated 120-kV coronary CTA, the ED ranged from 5.7 to 10.7 mSv and was approximately 50% lower with single-source 64-MDCT than with either DSCT protocol. In prospectively triggered 120-kV coronary CTA, the ED ranged from 3.8 to 4.0 mSv. The lowest ED of all protocols (1.3 mSv) was observed in prospectively triggered high-pitch 100-kV coronary CTA performed with dual-source 128-MDCT. Patient measurements showed similar dose reductions for prospective triggering and low voltage settings without an influence on signal-to-noise ratio or image quality. CONCLUSION: A combination of prospective triggering with low voltage settings is an effective measure for reducing the ED of coronary CTA to values of 2-4 mSv independent of scanner system. Further dose reduction to nearly 1 mSv can be achieved with high-pitch prospectively triggered coronary CTA.


Assuntos
Angiografia Coronária/instrumentação , Cardiopatias/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/instrumentação , Adulto , Idoso , Índice de Massa Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Estudos Retrospectivos , Dosimetria Termoluminescente
9.
AJR Am J Roentgenol ; 196(2): W159-65, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21257857

RESUMO

OBJECTIVE: The purpose of our study was to estimate cancer induction risk and generate risk conversion factors in cardiac CT angiography. MATERIALS AND METHODS: Under an institutional review board waiver and in compliance with HIPAA, we collected characteristics for a consecutive cohort of 100 patients (60 men and 40 women; mean age, 59 ± 11 years) who had previously undergone ECG-gated cardiac CT angiography on a 64-slice CT scanner. The volume CT Dose Index (CTDI(vol)) and dose-length product (DLP) were recorded and used with the ImPACT CT Patient Dosimetry Calculator to compute organ and effective doses in a standard 70 kg phantom. Patient-specific organ and effective doses were obtained by applying a weight-based correction factor. Radiation doses to radiosensitive organs were converted to risks using age- and sex-specific data published in BEIR VII. RESULTS: Median values were 62 mGy for CTDI(vol), 1,084 mGy-cm for DLP, and 17 cm for scan length. Effective doses ranged from 20 mSv (10th percentile) to 31 mSv (90th percentile). Median cancer induction risks in sensitive organs for men and women were 0.065% and 0.17%, respectively. For men and women, the range of risks was about a factor of 2. In men and women, about three quarters of the cancer risk was from lung cancer. Inclusion of the remaining less sensitive organs exposed during cardiac CT angiography examinations would likely increase the cancer induction risk by ∼20%. CONCLUSION: The average cancer induction risk in sensitive organs from cardiac CT angiography for our patient cohort was 0.13%, with a female to male cancer induction risk ratio of 2.6.


Assuntos
Angiografia Coronária/efeitos adversos , Modelos Estatísticos , Neoplasias Induzidas por Radiação/epidemiologia , Doses de Radiação , Medição de Risco/métodos , Tomografia Computadorizada por Raios X/efeitos adversos , Adulto , Idoso , Carga Corporal (Radioterapia) , Estudos de Coortes , Angiografia Coronária/estatística & dados numéricos , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/estatística & dados numéricos
10.
Expert Rev Cardiovasc Ther ; 9(1): 27-43, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21166527

RESUMO

Rapid technological evolution in multislice computed tomography (CT) over the last decade with improved spatial and temporal resolution has enabled cardiac CT to become a viable and effective alternative in the diagnosis of coronary artery disease. Within recent years CT coronary angiography has demonstrated high sensitivity and specificity, and in particular a very high negative-predictive value, making it a valuable imaging modality for ruling out suspected coronary artery disease. In addition, CT angiography demonstrates accuracy in the detection and characterization of coronary plaques, and it has been reported to play an important role in predicting disease progression and cardiac events. The goal of this article is to provide an overview on the role and current clinical applications of cardiac CT in the evaluation of coronary artery disease. Emerging areas of cardiac CT, including dual-energy CT and CT myocardial perfusion are also discussed, as well as the limitations and future directions of cardiac CT.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Animais , Angiografia Coronária/instrumentação , Angiografia Coronária/tendências , Ponte de Artéria Coronária , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/cirurgia , Humanos , Imageamento Tridimensional , Imagem de Perfusão do Miocárdio , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Stents , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/tendências
11.
Semin Ultrasound CT MR ; 31(4): 276-91, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20691928

RESUMO

The introduction of coronary CT angiography (cCTA) has reinvigorated the debate whether management of patients with suspected coronary artery disease (CAD) should be primarily based on physiological, functional versus anatomical testing. Anatomical testing (i.e., cCTA or invasive catheterization) enables direct visualization and grading of coronary artery stenoses but has shortcomings for gauging the hemodynamic significance of lesions for myocardial perfusion. Rest/stress myocardial perfusion imaging (MPI) has been extensively validated for assessing the clinical significance of CAD by demonstrating fixed or reversible perfusion defects but has only limited anatomical information. There is growing evidence that contrast medium enhanced dual-energy cCTA (DECT) has potential for the comprehensive analysis of coronary artery morphology as well as changes in myocardial perfusion. DECT exploits the fact that tissues in the human body and iodine-based contrast media have unique absorption characteristics when penetrated with different X-ray energy levels, which enables mapping the iodine (and thus blood) distribution within the myocardium. The purpose of this communication is to describe the practical application of this technology for the comprehensive diagnosis of ischemic heart disease. We examine recent scientific findings in the context of current pivotal transitions in cardiovascular disease management and demonstrate the potential of cardiac DECT for the integrative assessment of patients with known or suspected CAD within a single CT-based protocol.


Assuntos
Angiografia Coronária/métodos , Doença das Coronárias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Humanos , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X/instrumentação
12.
AJR Am J Roentgenol ; 194(6): 1500-6, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20489089

RESUMO

OBJECTIVE: The purpose of our study was to determine the interobserver reproducibility of CT findings of right ventricular (RV) dysfunction in pulmonary embolism (PE). MATERIALS AND METHODS: Two experienced observers independently and retrospectively evaluated pulmonary CT angiography (CTA) studies of 50 patients with acute PE for the following signs: bowing of the interventricular septum, inferior vena cava (IVC) contrast medium reflux, RV diameter (RVD)/left ventricular diameter (LVD) ratio on axial sections and four-chamber (4-CH) views, and RV volume (RVV)/left ventricular volume (LVV) ratio. Analysis used kappa statistics, Spearman's rank correlation, and Bland-Altman statistics. RESULTS: The two observers had fair to moderate agreement (kappa = 0.32-0.44) for septal bowing and moderate to good agreement (kappa = 0.57-0.68) for diagnosing IVC reflux. The Spearman's rank correlation coefficients for RVD(axial)/LVD(axial) ratio and RVD(4-CH)/LVD(4-CH) ratio between the two observers were 0.88 (p < 0.001) and 0.85 (p < 0.001), respectively. On Bland-Altman analysis, the mean differences for RVD(axial)/LVD(axial) ratio and RVD(4-CH)/LVD(4-CH) ratio were 0.014 (+/- 0.195) and 0.001 (+/- 0.242), respectively. The correlation coefficient for RVV/LVV ratio was 0.93 (p < 0.001), and the mean difference was 0.033 (+/- 0.229). CONCLUSION: Considerable differences exist in the interobserver reproducibility of CT findings of RV dysfunction on pulmonary CTA in patients with acute PE. Cardiac chamber measurements are more reproducible than septal bowing and IVC reflux. Volumetric determination of the RVV/LVV ratio is the least user dependent and most reproducible.


Assuntos
Angiografia Coronária/métodos , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia , Idoso , Meios de Contraste , Eletrocardiografia , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos
13.
J Cardiovasc Comput Tomogr ; 4(2): 127-35, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20430344

RESUMO

Recent research suggests that multidetector-row CT may have potential as a standalone modality for integrative imaging of coronary heart disease, including the assessment of the myocardial blood supply. However, the technical prerequisites for volumetric, time-resolved imaging of the passage of a contrast medium bolus through the myocardium have only been met with latest generation wide-detector CT scanners. Second-generation dual-source CT enables performing electrocardiographic (ECG)-synchronized dynamic myocardial perfusion imaging by a dedicated "shuttle" mode. With this acquisition mode, image data can be acquired during contrast medium infusion at 2 alternating table positions with the table shuttling back and forth between the 2 positions covering a 73-mm anatomic volume. We applied this acquisition technique for detecting differences in perfusion patterns between healthy and diseased myocardium and for quantifying myocardial blood flow under adenosine stress in 3 patients with coronary heart disease. According to our initial experience, the addition of adenosine stress volumetric dynamic CT perfusion to a cardiac CT protocol comprising coronary artery calcium quantification, prospectively ECG-triggered coronary CT angiography, and delayed acquisition appears promising for the comprehensive assessment of coronary artery luminal integrity, cardiac function, perfusion, and viability with a single modality.


Assuntos
Adenosina , Volume Cardíaco , Angiografia Coronária/métodos , Teste de Esforço/métodos , Cardiopatias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Aneurisma Coronário , Vasos Coronários , Estudos de Viabilidade , Cardiopatias/patologia , Testes de Função Cardíaca/métodos , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada de Emissão de Fóton Único
14.
Acad Radiol ; 17(6): 727-34, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20363161

RESUMO

RATIONALE AND OBJECTIVES: The aim of this study was to compare the reproducibility of bidimensional and volumetric quantification of epicardial adipose tissue (EAT) on cardiac computed tomography (CT) and evaluate their relationship with the extent of coronary artery disease (CAD). MATERIALS AND METHODS: Forty-five individuals underwent cardiac dual-source CT and conventional coronary angiography for suspicion of CAD. Nonenhanced images acquired to assess calcium score were used to quantify EAT. Coronary stenosis grading was performed on conventional coronary angiograms using Gensini scores. Two independent observers manually measured right ventricular EAT thickness at three different levels and in two different planes (four chamber and short axis) to obtain mean values. Additionally, EAT volume was automatically determined using a commercially available software tool. RESULTS: Conventional coronary angiography demonstrated nonstenotic coronary arteries in 22 subjects and significant coronary artery stenosis in 23. Significant correlations were observed between volumetric estimation of EAT and body mass index, coronary artery calcification, and Gensini score. On automatic volumetry, patients with significant coronary artery stenosis had significantly greater EAT volumes (154.58 +/- 58.91 mL) than those without significant CAD (120.94 +/- 81.85 mL) (P = .016). The manual bidimensional approach based on thickness measurements failed to show a significant difference between the two groups. Reproducibility and interobserver agreement for EAT quantification were higher when the automatic volumetric method was used (concordance-correlation coefficient, 0.96) compared to manual measurements (concordance-correlation coefficients, 0.37 for four-chamber EAT, 0.53 for short-axis EAT, and 0.58 for average EAT). CONCLUSIONS: For the quantification of EAT on cardiac CT, automated volumetry is more reproducible and correlates better with the extent of CAD than manual bidimensional measurements.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Imageamento Tridimensional/métodos , Reconhecimento Automatizado de Padrão/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto
15.
Eur J Radiol ; 68(3): 423-33, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19008064

RESUMO

The introduction of coronary CT angiography (cCTA) has reinvigorated the debate whether management of patients with suspected coronary artery disease (CAD) should be primarily based on physiological versus anatomical testing. Anatomical testing (i.e., cCTA or invasive catheterization) enables direct visualization and grading of coronary artery stenoses but has shortcomings for gauging the hemodynamic significance of lesions for myocardial perfusion. Conversely, rest/stress myocardial perfusion imaging (MPI) has been extensively validated for assessing the clinical significance of CAD by demonstrating fixed or reversible perfusion defects but has only limited anatomical information. There is early evidence that contrast medium enhanced dual-energy cCTA (DECT) has potential for the comprehensive analysis of coronary artery morphology as well as changes in myocardial perfusion. DECT exploits the fact that tissues in the human body and iodine-based contrast media have unique absorption characteristics when penetrated with different X-ray energy levels, which enables mapping the iodine (and thus blood) distribution within the myocardium. The purpose of this communication is to describe the practical application of this emerging technology for the comprehensive diagnosis of coronary artery disease in the context of the currently used tomographic imaging modalities (cCTA, nuclear MPI, MR MPI).


Assuntos
Calcinose/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...