Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 12(6)2023 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-36983442

RESUMO

BACKGROUND: Prior studies evaluating post-atrial fibrillation (AF) ablation pulmonary vein (PV) ostial gaps via magnetic resonance imaging (MRI) have shown circumferential PV fibrosis in a minority of patients, and their correlation with AF recurrence was weak. These studies were mostly based on radio-frequency AF ablations. AIM: We aimed to assess cryoballoon ablation-induced PV fibrosis via MRI and its correlation with AF recurrence. METHODS AND RESULTS: This was a prospective study of consecutive patients with symptomatic AF who underwent pre- and post-ablation MRI to assess baseline and ablation-induced fibrosis, respectively. Post-ablation PV gaps were assessed by new semi-quantitative visual analysis assisted by computerized ADAS analysis. AF recurrence monitored via multiple ECGs and event monitoring at 6 and 12 months post ablation. Nineteen patients with 80 PVs were included, age 56 ± 11, with paroxysmal and persistent AF in 17/19 and 2/19 patients, respectively. Baseline MRI showed minimal LA fibrosis. All patients underwent successful cryoballoon PV electrical isolation. Post-ablation MRI revealed circumferential PV fibrosis among 63/80 (78.8%) PVs and partial fibrosis with major gaps among 17/80 (21.2%) PVs. AF recurred within one year in 5/9 (55.5%) patients with partial PV fibrosis, while no AF recurred among the 10 patients in whom all PVs had circumferential fibrosis (p < 0.01). Similarly, there were significantly more PVs without circumferential fibrosis (due to major gaps) among patients with AF recurrence as compared with patients without AF recurrence (42.9% vs. 13.5%; p < 0.01). CONCLUSION: Cryoballoon AF ablation results in circumferential PV fibrosis in the majority of PVs, as assessed by a new clinically relevant MRI-LGE analysis. Significant correlation was found between major PV gaps on post-ablation MRI and AF recurrence, suggesting that MRI might have the ability to predict AF recurrence.

2.
J Cardiovasc Electrophysiol ; 33(4): 618-625, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35118762

RESUMO

BACKGROUND: A novel 3D mapping system (KODEX-EPD, EPD Solutions) enables catheter localization and real-time 3D cardiac mapping. OBJECTIVE: To evaluate left atrium (LA) anatomical mapping accuracy created by the KODEX-EPD system during pulmonary vein isolation (PVI) compared with gold standard computed tomography (CT) images acquired from the same patients before the procedure. METHODS: In 15 consecutive patients who underwent PVI, 3D mapping of the LA was created on the KODEX-EPD system using the Achieve catheter. Pulmonary vein (PV), posterior wall, and appendage anatomy and diameters, were compared to the CT 3D reconstruction measured on the CARTO 3 system. Measurements were done independently by two physicians in each method. Linear correlation and agreement between CT and EPD measurements were assessed by Spearman correlation and Bland-Altman plot. RESULTS: Mean LA mapping time was 7.7 ± 3.6 min. Very high interobserver correlation was found for both EPD and CT measurements (Spearman r = .9). High correlation (r = .75) was found between CT and EPD measurements. Bland-Altman plot method revealed that measurements assessed by EPD were slightly higher than those assessed by CT. Mean difference was 3.5 mm, p < .01. In 2 (13.5%) patients each, disagreement regarding the presence of a left common PV and a right middle accessory vein anatomy was seen. CONCLUSION: The new KODEX-EPD mapping system allows quick and accurate mapping of the LA with high correlation to CT imaging. Some differences in left common and accessory right middle vein anatomy were seen.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Computadores , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Imageamento Tridimensional/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Tomografia Computadorizada por Raios X
3.
Eur J Echocardiogr ; 11(7): E30, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20348158

RESUMO

The possible influence of the oesophageal diseases on the heart is well known. Deglutition syncope and pre-syncope have been described in relation to arrhythmias or mechanical problems. We report here a case of recurrent pre-syncope in a patient after gastric banding.


Assuntos
Deglutição , Acalasia Esofágica/etiologia , Gastroplastia/efeitos adversos , Átrios do Coração/diagnóstico por imagem , Síncope/etiologia , Adulto , Constrição Patológica/diagnóstico por imagem , Gastroplastia/métodos , Humanos , Masculino , Obesidade Mórbida/cirurgia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...