Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
AAPS J ; 24(3): 66, 2022 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-35534647

RESUMO

Decades of discussion and publication have gone into the guidance from the scientific community and the regulatory agencies on the use and validation of pharmacokinetic and toxicokinetic assays by chromatographic and ligand binding assays for the measurement of drugs and metabolites. These assay validations are well described in the FDA Guidance on Bioanalytical Methods Validation (BMV, 2018). While the BMV included biomarker assay validation, the focus was on understanding the challenges posed in validating biomarker assays and the importance of having reliable biomarker assays when used for regulatory submissions, rather than definition of the appropriate experiments to be performed. Different from PK bioanalysis, analysis of biomarkers can be challenging due to the presence of target analyte(s) in the control matrices used for calibrator and quality control sample preparation, and greater difficulty in procuring appropriate reference standards representative of the endogenous molecule. Several papers have been published offering recommendations for biomarker assay validation. The situational nature of biomarker applications necessitates fit-for-purpose (FFP) assay validation. A unifying theme for FFP analysis is that method validation requirements be consistent with the proposed context of use (COU) for any given biomarker. This communication provides specific recommendations for biomarker assay validation (BAV) by LC-MS, for both small and large molecule biomarkers. The consensus recommendations include creation of a validation plan that contains definition of the COU of the assay, use of the PK assay validation elements that support the COU, and definition of assay validation elements adapted to fit biomarker assays and the acceptance criteria for both.


Assuntos
Bioensaio , Bioensaio/métodos , Biomarcadores/análise , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Padrões de Referência
2.
Bioanalysis ; 9(22): 1807-1825, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29148835

RESUMO

The 2017 11th Workshop on Recent Issues in Bioanalysis (11th WRIB) took place in Los Angeles/Universal City, California from 3 April 2017 to 7 April 2017 with participation of close to 750 professionals from pharmaceutical/biopharmaceutical companies, biotechnology companies, contract research organizations and regulatory agencies worldwide. WRIB was once again a 5-day, weeklong event - A Full Immersion Week of Bioanalysis, Biomarkers and Immunogenicity. As usual, it was specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest including both small and large molecule analysis involving LCMS, hybrid LBA/LCMS and ligand-binding assay (LBA) approaches. This 2017 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop, and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2017 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 1) covers the recommendations for Small Molecules, Peptides and Small Molecule Biomarkers using LCMS. Part 2 (Biotherapeutics, Biomarkers and Immunogenicity Assays using Hybrid LBA/LCMS and Regulatory Agencies' Inputs) and Part 3 (LBA: Immunogenicity, Biomarkers and PK Assays) are published in volume 9 of Bioanalysis, issues 23 and 24 (2017), respectively.


Assuntos
Biomarcadores/análise , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas , Peptídeos/análise , Bibliotecas de Moléculas Pequenas/análise , Conferências de Consenso como Assunto , Guias como Assunto , Ligantes , Bibliotecas de Moléculas Pequenas/química
3.
Clin Chem ; 62(1): 48-69, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26719571

RESUMO

BACKGROUND: For many years, basic and clinical researchers have taken advantage of the analytical sensitivity and specificity afforded by mass spectrometry in the measurement of proteins. Clinical laboratories are now beginning to deploy these work flows as well. For assays that use proteolysis to generate peptides for protein quantification and characterization, synthetic stable isotope-labeled internal standard peptides are of central importance. No general recommendations are currently available surrounding the use of peptides in protein mass spectrometric assays. CONTENT: The Clinical Proteomic Tumor Analysis Consortium of the National Cancer Institute has collaborated with clinical laboratorians, peptide manufacturers, metrologists, representatives of the pharmaceutical industry, and other professionals to develop a consensus set of recommendations for peptide procurement, characterization, storage, and handling, as well as approaches to the interpretation of the data generated by mass spectrometric protein assays. Additionally, the importance of carefully characterized reference materials-in particular, peptide standards for the improved concordance of amino acid analysis methods across the industry-is highlighted. The alignment of practices around the use of peptides and the transparency of sample preparation protocols should allow for the harmonization of peptide and protein quantification in research and clinical care.


Assuntos
Técnicas de Laboratório Clínico , Espectrometria de Massas , Peptídeos/análise , Proteômica , Manejo de Espécimes , Guias como Assunto , Humanos , Peptídeos/isolamento & purificação , Pesquisadores
4.
Bioanalysis ; 7(23): 3019-34, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26627049

RESUMO

The 2015 9th Workshop on Recent Issues in Bioanalysis (9th WRIB) took place in Miami, Florida with participation of over 600 professionals from pharmaceutical and biopharmaceutical companies, biotechnology companies, contract research organizations and regulatory agencies worldwide. It is once again a 5-day week long event - a full immersion bioanalytical week - specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest in bioanalysis. The topics covered included both small and large molecules, and involved LCMS, hybrid LBA/LCMS, LBA approaches including the focus on biomarkers and immunogenicity. This 2015 White Paper encompasses recommendations that emerged from the extensive discussions held during the workshop, and is aimed at providing the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to advance scientific excellence, improve quality and deliver better regulatory compliance. Due to its length, the 2015 edition of this comprehensive White Paper has been divided into three parts. Part 2 covers the recommendations for hybrid LBA/LCMS and regulatory agencies' inputs. Part 1 (small molecule bioanalysis using LCMS) and Part 3 (large molecule bioanalysis using LBA, biomarkers and immunogenicity) will be published in volume 7 of Bioanalysis, issues 22 and 24, respectively.


Assuntos
Biomarcadores/química , Biofarmácia/organização & administração , Biotecnologia/organização & administração , História do Século XXI , Humanos
5.
Anal Biochem ; 356(2): 235-43, 2006 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-16797470

RESUMO

Proteolytic fragments of type II collagen, a major component of joint tissue, have recently been identified as biomarkers for osteoarthritis, a progressive disease associated with cartilage degeneration. A liquid chromatography/tandem mass spectrometry (MS/MS) assay that utilizes online immunoaffinity chromatography and column switching was developed in our laboratory for the neoepitope of type II collagen (NET2C). During method development, peptide collision-induced dissociation (CID) was found to be a significant source of assay variation, which exceeded 10% CV, despite the fact that a stable-isotope-labeled (SIL) internal standard was used to minimize imprecision. This phenomenon was studied in detail using peptides and associated SIL internal standards of varying lengths and amino acid compositions. Variability in peptide CID necessitated the monitoring of multiple MS/MS transitions to obtain acceptable assay precision. The assay was subsequently validated to measure NET2C concentrations in rat urine over the range of 0.1 to 10 ng/mL. The interday accuracy and precision ranged from 3.9 to 13.1 (%CV) and 10.7 to 5.3 (%RE), respectively, across the range of validated concentrations. A specific application of the assay is presented in which the role of estrogen deficiency in the development and progression of osteoarthritis was investigated. In this study, the effect of estrogen on lowering NET2C concentrations in urine in ovariectomized rats was demonstrated.


Assuntos
Biomarcadores/urina , Cromatografia Líquida de Alta Pressão/métodos , Colágeno Tipo II/urina , Espectrometria de Massas/métodos , Peptídeos/urina , Animais , Biomarcadores/química , Colágeno Tipo II/química , Feminino , Peptídeos/química , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...