Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med ; 114: 103151, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37813051

RESUMO

PURPOSE: To evaluate the variability of the 18F-FDG-PET/CT-based metabolic tumor volume (MTV) in anal cancers during fractionated chemoradiotherapy (CRT), and assess the impact of this variability on dosimetric accuracy in MTV-targeted dose painting. METHODS: Eleven patients with anal squamous cell carcinoma who received fractionated chemoradiotherapy with curative intent were included. 18F-FDG PET/CT images were acquired at pre- and mid-treatment. Target volumes and organs at risk (OARs) were contoured manually on both image series. The MTV was generated from the PET images by thresholding. Treatment plans were retrospectively optimized for both image series using volumetric modulated arc therapy (VMAT). Standard plans prescribed 48.6 Gy, 54 Gy and 57.5 Gy in 27 fractions to elective regions, lymph node metastases and primary tumor, respectively. Dose painting plans included an extra dose level of 65 Gy to the MTV. Pre-treatment plans were transferred and re-calculated at mid-treatment basis. RESULTS: MTV decreased from pre- to mid-treatment in 10 of the 11 patients. On average, 71 % of MTVmid overlapped with MTVpre. The median and mean doses to the MTV were robust against anatomical changes, but the transferred dose painting plans had lower D98% values than the original and re-optimized plans. No major differences were found between standard and dose painting plans for OARs. CONCLUSIONS: Despite volumetric changes in the MTV, adequate dose coverage was observed in most dose painting plans. The findings indicate little or no need for adaptive dose painting at mid-treatment. Dose painting appears to be a safe treatment alternative with similar dose sparing of OARs.


Assuntos
Neoplasias do Ânus , Radioterapia de Intensidade Modulada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluordesoxiglucose F18 , Carga Tumoral , Estudos Retrospectivos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Órgãos em Risco , Neoplasias do Ânus/diagnóstico por imagem , Neoplasias do Ânus/radioterapia
2.
Acta Oncol ; 56(6): 867-873, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28464748

RESUMO

BACKGROUND: Intrafraction motion in breast cancer radiation therapy (BCRT) has not yet been thoroughly described in the literature. It has been observed that baseline drift occurs as part of the intrafraction motion. This study aims to measure baseline drift and its incidence in free-breathing BCRT patients using an in-house developed laser system for tracking the position of the sternum. MATERIALS AND METHODS: Baseline drift was monitored in 20 right-sided breast cancer patients receiving free breathing 3D-conformal RT by using an in-house developed laser system which measures one-dimensional distance in the AP direction. A total of 357 patient respiratory traces from treatment sessions were logged and analysed. Baseline drift was compared to patient positioning error measured from in-field portal imaging. RESULTS: The mean overall baseline drift at end of treatment sessions was -1.3 mm for the patient population. Relatively small baseline drift was observed during the first fraction; however it was clearly detected already at the second fraction. Over 90% of the baseline drift occurs during the first 3 min of each treatment session. The baseline drift rate for the population was -0.5 ± 0.2 mm/min in the posterior direction the first minute after localization. Only 4% of the treatment sessions had a 5 mm or larger baseline drift at 5 min, all towards the posterior direction. Mean baseline drift in the posterior direction in free breathing BCRT was observed in 18 of 20 patients over all treatment sessions. CONCLUSIONS: This study shows that there is a substantial baseline drift in free breathing BCRT patients. No clear baseline drift was observed during the first treatment session; however, baseline drift was markedly present at the rest of the sessions. Intrafraction motion due to baseline drift should be accounted for in margin calculations.


Assuntos
Neoplasias da Mama/radioterapia , Movimento/efeitos da radiação , Órgãos em Risco/efeitos da radiação , Posicionamento do Paciente , Planejamento da Radioterapia Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/diagnóstico por imagem , Fracionamento da Dose de Radiação , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Radioterapia Conformacional/métodos , Respiração , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS