Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37724686

RESUMO

AIMS: The implantable cardioverter-defibrillator (ICD) is a life-saving therapy in patients with hypertrophic cardiomyopathy (HCM) at risk of sudden cardiac death. Implantable cardioverter-defibrillator complications are of concern. The subcutaneous ICD (S-ICD) does not use transvenous leads and is expected to reduce complications. However, it does not provide bradycardia and anti-tachycardia pacing (ATP). The aim of this study was to compare appropriate and inappropriate ICD interventions, complications, disease-related adverse events and mortality between HCM patients implanted with a S- or transvenous (TV)-ICD. METHODS AND RESULTS: Consecutive HCM patients implanted with a S- (n = 216) or TV-ICD (n = 211) were enrolled. Propensity-adjusted cumulative Kaplan-Meier curves and multivariate Cox proportional hazard ratios were used to compare 5-year event-free survival and the risk of events. The S-ICD patients had lower 5-year risk of appropriate (HR: 0.32; 95%CI: 0.15-0.65; P = 0.002) and inappropriate (HR: 0.44; 95%CI: 0.20-0.95; P = 0.038) ICD interventions, driven by a high incidence of ATP therapy in the TV-ICD group. The S- and TV-ICD patients experienced similar 5-year rate of device-related complications, albeit the risk of major lead-related complications was lower in S-ICD patients (HR: 0.17; 95%CI: 0.038-0.79; P = 0.023). The TV- and S-ICD patients displayed similar risk of disease-related complications (HR: 0.64; 95%CI: 0.27-1.52; P = 0.309) and mortality (HR: 0.74; 95%CI: 0.29-1.87; P = 0.521). CONCLUSION: Hypertrophic cardiomyopathy patients implanted with a S-ICD had lower 5-year risk of appropriate and inappropriate ICD therapies as well as of major lead-related complications as compared to those implanted with a TV-ICD. Long-term comparative follow-up studies will clarify whether the lower incidence of major lead-related complications will translate into a morbidity or survival benefit.


Assuntos
Cardiomiopatia Hipertrófica , Desfibriladores Implantáveis , Humanos , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/terapia , Bradicardia , Progressão da Doença , Trifosfato de Adenosina
3.
Int J Cardiol ; 366: 42-47, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-35780930

RESUMO

AIMS: Predictors of sudden cardiac death (SCD) in patients with hypertrophic cardiomyopathy (HCM) do not include ECG variables. Intrinsicoid deflection (ID) represents the early ventricular depolarization on surface ECG. Delayed ID (DID) has been associated with sudden cardiac arrest (SCA) in the community. In a cohort of consecutive patients with HCM, we assessed whether DID predicts SCA or its surrogates. METHODS: We reviewed ECG, clinical and follow-up data of 344 consecutive HCM patients. DID (ID ≥50 ms) was classified as lateral (leads I or aVL), inferior (leads II, III or aVF), and precordial (leads V5 or V6). The endpoint was a combination of SCD, resuscitated SCA or appropriate ICD intervention. RESULTS: The SCA group was composed by 2 secondary prevention ICD recipients and 23 patients that reached the endpoint during follow-up (108 ± 73 months). SCA patients had more frequently massive LV hypertrophy (LVH) or end-stage HCM. ECG indexes of LVH were comparable between SCA and controls. SCA patients were more likely to have DID on ECG lateral leads I/aVL (72% vs 44%; p = 0.008). A non significant trend was observed for inferior and V5/V6 leads. DID I/aVL was associated with SCA in multivariate analysis after correction for massive LVH and end-stage disease (HR: 2.86; 95%CI: 1.14-7.13; p = 0.02). CONCLUSIONS: In HCM patients DID is associated with increased risk of SCA. Its prognostic value extends beyond that of LVH. If confirmed in prospective studies, the prognostic power of this ECG marker could be used to refine risk prediction.


Assuntos
Cardiomiopatia Hipertrófica , Eletrocardiografia , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico , Morte Súbita Cardíaca/prevenção & controle , Eletrocardiografia/efeitos adversos , Humanos , Hipertrofia Ventricular Esquerda , Estudos Prospectivos , Fatores de Risco
4.
J Interv Card Electrophysiol ; 64(1): 257-264, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35412167

RESUMO

BACKGROUND: The remote device management (RM) is recommended for patients with cardiac implantable electronic devices (CIEDs). RM underutilization is frequently driven by the lack of correct system activation. The MyLATITUDE Patient App (Boston Scientific) has been developed to encourage patient compliance with RM by providing information on communicator setup, troubleshooting, and connection status of the communicator. METHODS: At 14 centers, patients with CIEDs were invited to download and install the App on a mobile device. After 3 months, patients were asked to complete an ad hoc questionnaire to evaluate their experience. RESULTS: The App was proposed to 242 consecutive patients: 81 before RM activation, and 161 during follow-up. The App was successfully installed by 177 (73%) patients. The time required for activation of the communicator and the need for additional support were similar between patients who followed the indications provided by the App and those who underwent standard in-clinic training. During follow-up, notifications of lack of connection were received by 20 (11%) patients and missed transmission by 22 (12%). The median time from notification to resolution was 2 days. After 3 months, 175 (99%) communicators of the 177 patients who installed the App were in "Monitored" status versus 113 (94%) of 120 patients without the App installed (p=0.033). The use of the app made 84% of patients feel reassured. CONCLUSIONS: The App was well accepted by CIED patients and offered support for communicator management and installation. Its use enabled patients to remain connected with greater continuity during follow-up.


Assuntos
Desfibriladores Implantáveis , Aplicativos Móveis , Marca-Passo Artificial , Humanos , Monitorização Fisiológica , Estudos Multicêntricos como Assunto , Cooperação do Paciente
5.
Front Cardiovasc Med ; 8: 703418, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34485402

RESUMO

Takotsubo syndrome (TTS) is an increasingly recognized condition burdened by significant acute and long-term adverse events. The availability of novel techniques expanded the knowledge on TTS and allowed a more accurate risk-stratification, potentially guiding clinical management. The present review aims to summarize the recent advances in TTS prognostic evaluation with a specific focus on novel imaging and genetic markers. Parametric deformation analysis by speckle-tracking echocardiography, as well as tissue characterization by cardiac magnetic resonance imaging T1 and T2 mapping techniques, currently appear the most clinically valuable applications. Notwithstanding, computed tomography and nuclear imaging studies provided limited but promising data. A genetic predisposition to TTS has been hypothesized, though available evidence is still not sufficient. Although a genetic predisposition appears likely, further studies are needed to fully characterize the genetic background of TTS, in order to identify genetic markers that could assist in predicting disease recurrences and help in familial screening.

6.
J Cardiovasc Electrophysiol ; 32(6): 1695-1703, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33969578

RESUMO

BACKGROUND: The traditional technique for subcutaneous implantable cardioverter defibrillator (S-ICD) implantation involves three incisions and a subcutaneous (SC) pocket. An intermuscular (IM) 2-incision technique has been recently adopted. AIMS: We assessed acute defibrillation efficacy (DE) of S-ICD (DE ≤65 J) according to the implantation technique. METHODS: We analyzed consecutive patients who underwent S-ICD implantation and DE testing at 53 Italian centers. Regression analysis was used to determine the association between DFT and implantation technique. RESULTS: A total of 805 patients were enrolled. Four groups were assessed: IM + 2 incisions (n = 546), SC + 2 incisions (n = 133), SC + 3 incisions (n = 111), and IM + 3 incisions (n = 15). DE was ≤65 J in 782 (97.1%) patients. Patients with DE ≤65 J showed a trend towards lower body mass index (25.1 vs. 26.5; p = .12), were less frequently on antiarrhythmic drugs (13% vs. 26%; p = .06) and more commonly underwent implantation with the 2-incision technique (85% vs. 70%; p = .04). The IM + 2-incision technique showed the lowest defibrillation failure rate (2.2%) and shock impedance (66 Ohm, interquartile range: 57-77). On multivariate analysis, the 2-incision technique was associated with a lower incidence of shock failure (hazard ratio: 0.305; 95% confidence interval: 0.102-0.907; p = .033). Shock impedance was lower with the IM than with the SC approach (66 vs. 70 Ohm p = .002) and with the 2-incision than the 3-incision technique (67 vs. 72 Ohm; p = .006). CONCLUSIONS: In a large population of S-ICD patients, we observed a high defibrillation success rate. The IM + 2-incision technique provides lower shock impedance and a higher likelihood of successful defibrillation.


Assuntos
Desfibriladores Implantáveis , Índice de Massa Corporal , Cardioversão Elétrica/efeitos adversos , Impedância Elétrica , Humanos , Implantação de Prótese/efeitos adversos , Tela Subcutânea , Resultado do Tratamento
7.
J Clin Med ; 10(8)2021 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-33916967

RESUMO

While most patients with hypertrophic cardiomyopathy (HCM) show a relatively stable morphologic and clinical phenotype, in some others, progressive changes in the left ventricular (LV) wall thickness, cavity size, and function, defined, overall, as "LV remodeling", may occur. The interplay of multiple pathophysiologic mechanisms, from genetic background to myocardial ischemia and fibrosis, is implicated in this process. Different patterns of LV remodeling have been recognized and are associated with a specific impact on the clinical course and management of the disease. These findings underline the need for and the importance of serial multimodal clinical and instrumental evaluations to identify and further characterize the LV remodeling phenomenon. A more complete definition of the stages of the disease may present a chance to improve the management of HCM patients.

8.
Pacing Clin Electrophysiol ; 44(6): 995-1003, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33908052

RESUMO

BACKGROUND: During the COVID-19 pandemic in-person visits for patients with cardiac implantable electronic devices should be replaced by remote monitoring (RM), in order to prevent viral transmission. A direct home-delivery service of the RM communicator has been implemented at 49 Italian arrhythmia centers. METHODS: According to individual patient preference or the organizational decision of the center, patients were assigned to the home-delivery group or the standard in-clinic delivery group. In the former case, patients received telephone training on the activation process and use of the communicator. In June 2020, the centers were asked to reply to an ad hoc questionnaire to describe and evaluate their experience in the previous 3 months. RESULTS: RM was activated in 1324 patients: 821 (62%) received the communicator at home and the communicator was activated remotely. Activation required one additional call in 49% of cases, and the median time needed to complete the activation process was 15 min [25th-75th percentile: 10-20]. 753 (92%) patients were able to complete the correct activation of the system. At the time when the questionnaire was completed, 743 (90%) communicators were regularly transmitting data. The service was generally deemed useful (96% of respondents) in facilitating the activation of RM during the COVID-19 pandemic and possibly beyond. CONCLUSIONS: Home delivery of the communicator proved to be a successful approach to system activation, and received positive feedback from clinicians. The increased use of a RM protocol will reduce risks for both providers and patients, while maintaining high-quality care.


Assuntos
Arritmias Cardíacas/terapia , COVID-19/epidemiologia , Desfibriladores Implantáveis , Serviços de Assistência Domiciliar , Distanciamento Físico , Pneumonia Viral/epidemiologia , Tecnologia de Sensoriamento Remoto/instrumentação , Feminino , Humanos , Incidência , Itália , Masculino , Marca-Passo Artificial , Pandemias , Pneumonia Viral/virologia , SARS-CoV-2
9.
Cureus ; 13(1): e13009, 2021 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-33659140

RESUMO

Pulmonary anomalous venous return (PAPVR) is defined as a congenital anomaly in which at least one but not all of the pulmonary veins abnormally drain into a systemic vein or directly into the right atrium. Signs and symptoms related to this condition are due to the hemodynamic abnormalities secondary to left-to-right shunt and the possible presence of other associated cardiac anomalies (e.g., sinus venous atrial septal defect). Therefore, depending on the extent of the shunt, the clinical presentation of PAPVR is variable, ranging from asymptomatic patients to patients affected by severe heart failure with right-sided volume overload. PAPVR with a clinically significant shunt should be referred for surgical correction with different techniques depending on the presence of associated cardiac anomalies. We are presenting a case of partial anomalous venous return (PAPVR) in a 66-year-old man who underwent surgery 26 years ago to correct an anomalous venous connection between the right superior pulmonary vein (RSPV) and the superior vena cava (SVC) through a veno-atrial baffle. The patient was admitted to the emergency department due to atrial tachycardia. Trans-thoracic echocardiography (TTE) showed a dilated right ventricle (RV) with mild RV systolic dysfunction and pulmonary hypertension. Cardiac magnetic resonance (CMR) further confirmed the findings described by TTE and also demonstrated areas of fibrosis replacement in the hinge points. Cardiac computed tomography (CCT) was able to accurately depict and evaluate the surgically created veno-atrial baffle and also showed an anomalous connection between the left superior pulmonary vein (LSPV) and the brachiocephalic vein (BCV) through a vertical vein. The patient was successfully treated with radiofrequency ablation for his arrhythmia.

10.
Europace ; 22(12): 1822-1829, 2020 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-33118017

RESUMO

AIMS: The traditional technique for subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation involves three incisions and a subcutaneous pocket. Recently, a two-incision and intermuscular (IM) technique has been adopted. The PRAETORIAN score is a chest radiograph-based tool that predicts S-ICD conversion testing. We assessed whether the S-ICD implantation technique affects optimal position of the defibrillation system according to the PRAETORIAN score. METHODS AND RESULTS: We analysed consecutive patients undergoing S-ICD implantation. The χ2 test and regression analysis were used to determine the association between the PRAETORIAN score and implantation technique. Two hundred and thirteen patients were enrolled. The S-ICD generator was positioned in an IM pocket in 174 patients (81.7%) and the two-incision approach was adopted in 199 (93.4%). According to the PRAETORIAN score, the risk of conversion failure was classified as low in 198 patients (93.0%), intermediate in 13 (6.1%), and high in 2 (0.9%). Patients undergoing the two-incision and IM technique were more likely to have a low (<90) PRAETORIAN score than those undergoing the three-incision and subcutaneous technique (two-incision: 94.0% vs. three-incision: 78.6%; P = 0.004 and IM: 96.0% vs. subcutaneous: 79.5%; P = 0.001). Intermuscular plus two-incision technique was associated with a low-risk PRAETORIAN score (hazard ratio 3.76; 95% confidence interval 1.01-14.02; P = 0.04). Shock impedance was lower in PRAETORIAN low-risk patients than in intermediate-/high-risk categories (66 vs. 96 Ohm; P = 0.001). The PRAETORIAN score did not predict shock failure at 65 J. CONCLUSION: In this cohort of S-ICD recipients, combining the two-incision technique and IM generator implantation yielded the lowest PRAETORIAN score values, indicating optimal defibrillation system position. CLINICAL TRIAL REGISTRATION: http://clinicaltrials.gov/ Identifier: NCT02275637.


Assuntos
Desfibriladores Implantáveis , Estudos de Coortes , Impedância Elétrica , Humanos , Implantação de Prótese/efeitos adversos , Fatores de Risco
11.
High Blood Press Cardiovasc Prev ; 27(4): 291-297, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32519207

RESUMO

The implantable cardioverter-defibrillator (ICD) is the most effective therapy to prevent sudden cardiac death (SCD) in high-risk patients. To overcome infections and failure of transvenous leads, the most frightening complications of conventional ICDs, a completely subcutaneous ICD (S-ICD) has been developed and is currently adopted in routine clinical practice. In view of their long life-expectancy, low competitive risk of dying from non-arrhythmic causes, and high lifetime risk of lead-related complications requiring surgical revisions, young patients with cardiomyopathies and inherited arrhythmia syndromes have traditionally been considered ideal candidates for the S-ICD. However, as growing evidence supported S-ICD safety and efficacy, initial niche implant indications were abandoned in favor of a widespread use of this technology, that is currently adopted in common ICD candidates with severe left ventricular dysfunction. Indeed, guidelines recommend S-ICD implantation as an alternative to TV-ICDs in all ICD candidates, unless pacing is required. This review focuses on the contemporary experience with the S-ICD and explores future scenarios in which device-to-device communication will enable to combine leadless therapies.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Humanos , Desenho de Prótese , Fatores de Risco , Resultado do Tratamento
12.
J Cardiovasc Electrophysiol ; 31(8): 2093-2098, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32437006

RESUMO

INTRODUCTION: The prognostic impact of nonsustained ventricular tachycardia (NSVT) morphology has never been explored in hypertrophic cardiomyopathy (HCM). In a single-center cohort of consecutive HCM patients implanted with an implanted cardioverter-defibrillator (ICD), we assessed NSVT morphology patterns and their prognostic implications. METHODS: A cohort of consecutive HCM patients implanted with an ICD was followed from ICD implantation to last follow-up visit. Patients were assessed for NSVT as stored events in ICD memory. Ventricular tachycardias (VTs) were classified as monomorphic (MM) or polymorphic according to intracardiac electrogram morphology. RESULTS: One hundred nine consecutive HCM patients (68 males; mean age: 45 ± 17 years) composed the study population. During follow-up (71 ± 48 months), 7 polymorphic NSVT in 4 patients and 370 MM NSVT in 42 patients were retrieved from ICD memory. Among patients with only MM NSVT, 19 (45%) had one morphology, 17 (41%) had two morphologies, 3 (7%) had three morphologies, and 3 (7%) had four morphologies. Patients with polymorphic NSVT had the highest risk of ICD interventions (HR, 5.04; 95% CI, 1.26-20.19; P = .02). A stepwise increase of the risk of ICD interventions in patients with two, three, and four NSVT morphologies was observed. Out of 16 patients with both NSVT and ICD-treated VTs, 13 (81%) had at least one ICD-treated VT with the same morphology of a previous long-lasting NSVT. CONCLUSIONS: In high-risk HCM patients, the occurrence of polymorphic NSVT and of NSVT with multiple morphologies carries a high risk for ICD interventions. Sustained VTs tend to recur with the same morphology of previous long-lasting NSVTs.


Assuntos
Cardiomiopatia Hipertrófica , Desfibriladores Implantáveis , Taquicardia Ventricular , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/terapia , Cardioversão Elétrica , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Medição de Risco , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia
13.
High Blood Press Cardiovasc Prev ; 27(5): 341-347, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32451990

RESUMO

Atrial fibrillation (AF) is the most common cardiac arrhythmia. Pharmacologic and non-pharmacologic rhythm control strategies impact on AF-related symptoms, while leaving largely unaffected the risk of stroke. Moreover, up to 20% of AF patients are asymptomatic during paroxysmal relapses of arrhythmia, thus underlying the need for early markers to identify at-risk patients and prevent cerebrovascular accidents. Indeed, non-invasive assessment of pre-clinical substrate changes that predispose to AF could provide early identification of at-risk patients and allow for tailored care paths. ECG-derived P wave analysis is a simple-to-use and inexpensive tool that has been successfully employed to detect AF-associated structural and functional atrial changes. Beyond standard electrocardiographic techniques, high resolution signal averaged electrocardiography (SAECG), by recording microvolt amplitude atrial signals, allows more accurate analysis of the P wave and possibly AF risk stratification. This review focuses on the evidence that support P wave analysis to assess AF substrates, predict arrhythmia relapses and guide rhythm-control interventions.


Assuntos
Potenciais de Ação , Fibrilação Atrial/diagnóstico , Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Potenciais de Ação/efeitos dos fármacos , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Estimulação Cardíaca Artificial , Ablação por Cateter , Sistema de Condução Cardíaco/cirurgia , Frequência Cardíaca/efeitos dos fármacos , Humanos , Valor Preditivo dos Testes , Recidiva , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Resultado do Tratamento
15.
Eur J Intern Med ; 65: 6-11, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31005441

RESUMO

The subcutaneous implantable cardioverter defibrillator (S-ICD) is a valuable alternative to the conventional trans-venous ICD (TV-ICD) for the prevention of sudden cardiac death (SCD). Prospective registries showed that the S-ICD is safe and effective in treating ventricular tachyarrhythmias in high-risk patients without pacing indications. While in earlier studies patients implanted with S-ICDs were young and mostly affected by channelopathies, contemporary S-ICD cohorts include patients with severely impaired left ventricular function and significant comorbidities. This review focuses on S-ICD evidence-based use and highlights current gaps between guidelines recommendations and real-world clinical practice.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/tendências , Desenho de Equipamento/tendências , Tela Subcutânea , Taquicardia Ventricular/terapia , Ensaios Clínicos como Assunto , Morte Súbita Cardíaca/epidemiologia , Humanos , Guias de Prática Clínica como Assunto , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia
16.
Pacing Clin Electrophysiol ; 42(6): 610-616, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30903669

RESUMO

BACKGROUND: In hypertrophic cardiomyopathy (HCM) patients implanted with an implantable cardioverter defibrillator (ICD), clinical outcomes of antitachycardia pacing (ATP) have been poorly explored. In a retrospective analysis of a cohort of consecutive HCM patients implanted with an ICD, we aimed to assess the efficacy, safety, and clinical value of ATP. METHODS: The cohort of HCM patients implanted with a transvenous ICD and followed in our center was assessed for device intervention from implantation to last clinical follow-up. RESULTS: Overall 77 patients (45 males; mean age: 46 ± 16 years) were analyzed. After 67 ± 41 months, 24 patients had 49 ventricular tachycardia/fibrillation (VT/VF) appropriately treated (5.8% per year). Among 39 monomorphic VTs, ATP was effective in 27 (success rate: 69%). Mean time from VT onset to ATP delivery was 9.1 ± 4.9 s. The only clinical variable improving ATP success was use of beta-blockers (81% vs 50%; P = .04). Out of 12 ineffectively treated VTs, one was immediately shocked, four self-terminated after 18 ± 12 s, and seven (18%) were accelerated to a new VT. ATP was also delivered for 27 of 42 inappropriately detected episodes and induced two de novo VTs (7%). In the per patient analysis, 14 out 77 (18%) patients had one or more appropriate and effective ATP (3.4% per year), and only six (8%; 1.4% per year) received more than one ATP. CONCLUSION: ATP is moderately effective for the treatment of monomorphic VTs in HCM patients. However, the rate of appropriate ATP therapies is low, ATP is often prematurely delivered, and ATP-induced arrhythmia degeneration is of concern.


Assuntos
Cardiomiopatia Hipertrófica/complicações , Desfibriladores Implantáveis , Taquicardia Ventricular/prevenção & controle , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevenção Primária , Estudos Retrospectivos , Medição de Risco , Prevenção Secundária
17.
Ann Noninvasive Electrocardiol ; 24(2): e12595, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30265434

RESUMO

Junctional and AV nodal reentrant tachycardia share common electrocardiographic features, but they differ in their management and outcomes after catheter ablation. This case concerns a 60-year-old female who presented with recurrent episodes of a relatively slow, regular supraventricular arrhythmia. Electrocardiographic features of the arrhythmia were discordant regarding its underlying mechanism. However, careful analysis of 12-lead electrocardiograms, with focus on the effect of spontaneous premature beats, pointed out the arrhythmia etiology. Electrophysiological study and pacing maneuvers defined the arrhythmic substrate that was successfully treated by catheter ablation.


Assuntos
Ablação por Cateter/métodos , Eletrocardiografia/métodos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico por imagem , Taquicardia por Reentrada no Nó Atrioventricular/terapia , Taquicardia Supraventricular/diagnóstico por imagem , Diagnóstico Diferencial , Eletrofisiologia/métodos , Feminino , Seguimentos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Pessoa de Meia-Idade , Recidiva , Medição de Risco , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia Supraventricular/fisiopatologia , Resultado do Tratamento
18.
Am J Cardiol ; 122(11): 1924-1931, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-30293658

RESUMO

In hypertrophic cardiomyopathy (HC), a process of left ventricular (LV) remodeling carrying an adverse prognosis has been described. Conversely, a gradual and benign LV wall thinning has been suggested but never investigated. Therefore, we studied a HC cohort over a long period of time to evaluate the occurrence of a LV remodeling with a benign clinical course. Data of HC patients aged 18 to 65 years and without any condition known to influence LV remodeling were analyzed over a mean follow-up of 7.6 ± 5.7 years. Of 231 HC patients (65% males, mean age 46 ± 12 years), 47 (20%) developed LV remodeling, of whom 23 (10%) had a thinning ≥15% of LV maximal wall thickness from baseline without systolic dysfunction (MWT thinning); 13 (6%) progressed to a LV ejection fraction <50% (end-stage HC) and 11 (5%) developed an apical aneurysm. Follow-up length (odds ratio 1.07, 95% confidence interval 1.00 to 1.15, p = 0.06) and maximal LV wall thickness at baseline (odds ratio 1.14, 95% confidence interval 1.04 to 1.25, p = 0.004) were the main predictors of MWT thinning. Compared with patients with end-stage HC and apical aneurysm, those with MWT thinning showed lower HC-related morbidity (92% and 36% vs 22%, p = 0.003) and mortality (31% and 27% vs 4%, p = 0.02). Furthermore, they showed a combined HC-related morbidity and mortality similar to patients without LV remodeling (incidence 29/1000 vs 26/1000 patient-year, p = 0.77). In conclusion, a process of LV wall thinning with a benign outcome can occur over the long term in patients with HC. The prognostic importance of LV remodeling varies in relation to the different changes in LV morphology and function.


Assuntos
Cardiomiopatia Hipertrófica/fisiopatologia , Ventrículos do Coração/fisiopatologia , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Remodelação Ventricular , Adolescente , Adulto , Idoso , Cardiomiopatia Hipertrófica/diagnóstico , Ecocardiografia Doppler , Eletrocardiografia , Feminino , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Fatores de Tempo , Adulto Jovem
20.
Rev Port Cardiol (Engl Ed) ; 37(4): 351.e1-351.e4, 2018 Apr.
Artigo em Inglês, Português | MEDLINE | ID: mdl-29678624

RESUMO

In women with hypertrophic cardiomyopathy (HCM), pregnancy prompts major changes in hemodynamic and cardiac autonomic function that may precipitate heart failure (HF) or increase the risk of cardiac arrhythmia. We report the clinical follow-up of two patients with non-obstructive HCM implanted with a cardioverter defibrillator (ICD) allowing for continuous analysis of heart rate (HR), heart rate variability (HRV) and cardiac arrhythmia throughout the entire course of pregnancy. Both patients experienced increased HR and decreased HRV from the early stages of pregnancy, which persisted until delivery. Premature ventricular contractions (PVCs) and runs of non-sustained ventricular tachycardia (NSVT) reached a peak in the second and third trimesters, concurrent with sympathetic hyperactivity. In one patient with baseline NYHA class II HF symptoms, increased PVCs and NSVT were consistent with the deterioration of HF, supporting the decision to bring the delivery forward. While both patients experienced a persistent increase in sympathetic tone and ventricular ectopic activity, no life-threatening arrhythmias were documented. During pregnancy, patients with hypertrophic cardiomyopathy develop progressive neuroautonomic imbalance, prompting an increase in non-sustained ventricular arrhythmia. This enhanced arrhythmia burden warrants close follow-up and rhythm assessment during the third trimester, especially in women who have heart failure symptoms before pregnancy. Implantable cardioverter defibrillators provide a continuous analysis of heart rate variability and arrhythmia burden that supports therapeutic decision-making during follow-up.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Complicações Cardiovasculares na Gravidez/terapia , Adulto , Arritmias Cardíacas/etiologia , Sistema Nervoso Autônomo/fisiopatologia , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/fisiopatologia , Feminino , Frequência Cardíaca , Humanos , Gravidez , Complicações Cardiovasculares na Gravidez/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...