Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cell Rep ; 43(5): 114186, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38700985

RESUMO

The fine control of synaptic function requires robust trans-synaptic molecular interactions. However, it remains poorly understood how trans-synaptic bridges change to reflect the functional states of the synapse. Here, we develop optical tools to visualize in firing synapses the molecular behavior of two trans-synaptic proteins, LGI1 and ADAM23, and find that neuronal activity acutely rearranges their abundance at the synaptic cleft. Surprisingly, synaptic LGI1 is primarily not secreted, as described elsewhere, but exo- and endocytosed through its interaction with ADAM23. Activity-driven translocation of LGI1 facilitates the formation of trans-synaptic connections proportionally to the history of activity of the synapse, adjusting excitatory transmission to synaptic firing rates. Accordingly, we find that patient-derived autoantibodies against LGI1 reduce its surface fraction and cause increased glutamate release. Our findings suggest that LGI1 abundance at the synaptic cleft can be acutely remodeled and serves as a critical control point for synaptic function.

2.
Neurophotonics ; 11(2): 024207, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38577628

RESUMO

Significance: Genetically encoded calcium ion (Ca2+) indicators (GECIs) are powerful tools for monitoring intracellular Ca2+ concentration changes in living cells and model organisms. In particular, GECIs have found particular utility for monitoring the transient increase of Ca2+ concentration that is associated with the neuronal action potential. However, the palette of highly optimized GECIs for imaging of neuronal activity remains relatively limited. Expanding the selection of available GECIs to include new colors and distinct photophysical properties could create new opportunities for in vitro and in vivo fluorescence imaging of neuronal activity. In particular, blue-shifted variants of GECIs are expected to have enhanced two-photon brightness, which would facilitate multiphoton microscopy. Aim: We describe the development and applications of T-GECO1-a high-performance blue-shifted GECI based on the Clavularia sp.-derived mTFP1. Approach: We use protein engineering and extensive directed evolution to develop T-GECO1. We characterize the purified protein and assess its performance in vitro using one-photon excitation in cultured rat hippocampal neurons, in vivo using one-photon excitation fiber photometry in mice, and ex vivo using two-photon Ca2+ imaging in hippocampal slices. Results: The Ca2+-bound state of T-GECO1 has an excitation peak maximum of 468 nm, an emission peak maximum of 500 nm, an extinction coefficient of 49,300 M-1 cm-1, a quantum yield of 0.83, and two-photon brightness approximately double that of EGFP. The Ca2+-dependent fluorescence increase is 15-fold, and the apparent Kd for Ca2+ is 82 nM. With two-photon excitation conditions at 850 nm, T-GECO1 consistently enabled the detection of action potentials with higher signal-to-noise (SNR) than a late generation GCaMP variant. Conclusions: T-GECO1 is a high-performance blue-shifted GECI that, under two-photon excitation conditions, provides advantages relative to late generation GCaMP variants.

3.
Elife ; 122024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38393319

RESUMO

Intracellular levels of the amino acid aspartate are responsive to changes in metabolism in mammalian cells and can correspondingly alter cell function, highlighting the need for robust tools to measure aspartate abundance. However, comprehensive understanding of aspartate metabolism has been limited by the throughput, cost, and static nature of the mass spectrometry (MS)-based measurements that are typically employed to measure aspartate levels. To address these issues, we have developed a green fluorescent protein (GFP)-based sensor of aspartate (jAspSnFR3), where the fluorescence intensity corresponds to aspartate concentration. As a purified protein, the sensor has a 20-fold increase in fluorescence upon aspartate saturation, with dose-dependent fluorescence changes covering a physiologically relevant aspartate concentration range and no significant off target binding. Expressed in mammalian cell lines, sensor intensity correlated with aspartate levels measured by MS and could resolve temporal changes in intracellular aspartate from genetic, pharmacological, and nutritional manipulations. These data demonstrate the utility of jAspSnFR3 and highlight the opportunities it provides for temporally resolved and high-throughput applications of variables that affect aspartate levels.


Assuntos
Ácido Aspártico , Técnicas Biossensoriais , Animais , Ácido Aspártico/análise , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Linhagem Celular , Proteínas de Fluorescência Verde/metabolismo , Mamíferos/metabolismo
4.
Nat Commun ; 14(1): 6598, 2023 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-37891202

RESUMO

L-Lactate is increasingly appreciated as a key metabolite and signaling molecule in mammals. However, investigations of the inter- and intra-cellular dynamics of L-lactate are currently hampered by the limited selection and performance of L-lactate-specific genetically encoded biosensors. Here we now report a spectrally and functionally orthogonal pair of high-performance genetically encoded biosensors: a green fluorescent extracellular L-lactate biosensor, designated eLACCO2.1, and a red fluorescent intracellular L-lactate biosensor, designated R-iLACCO1. eLACCO2.1 exhibits excellent membrane localization and robust fluorescence response. To the best of our knowledge, R-iLACCO1 and its affinity variants exhibit larger fluorescence responses than any previously reported intracellular L-lactate biosensor. We demonstrate spectrally and spatially multiplexed imaging of L-lactate dynamics by coexpression of eLACCO2.1 and R-iLACCO1 in cultured cells, and in vivo imaging of extracellular and intracellular L-lactate dynamics in mice.


Assuntos
Técnicas Biossensoriais , Ácido Láctico , Camundongos , Animais , Técnicas Biossensoriais/métodos , Transferência Ressonante de Energia de Fluorescência , Células Cultivadas , Imagem Óptica , Mamíferos
5.
bioRxiv ; 2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37905143

RESUMO

Significance: Genetically encoded calcium ion (Ca2+) indicators (GECIs) are powerful tools for monitoring intracellular Ca2+ concentration changes in living cells and model organisms. In particular, GECIs have found particular utility for monitoring the transient increase of Ca2+ concentration that is associated with the neuronal action potential. However, the palette of highly optimized GECIs for imaging of neuronal activity remains relatively limited. Expanding the selection of available GECIs to include new colors and distinct photophysical properties could create new opportunities for in vitro and in vivo fluorescence imaging of neuronal activity. In particular, blue-shifted variants of GECIs are expected to have enhanced two-photon brightness, which would facilitate multiphoton microscopy. Aim: We describe the development and applications of T-GECO1 - a high-performance blue-shifted GECI based on the Clavularia sp.-derived mTFP1. Approach: We used protein engineering and extensive directed evolution to develop T-GECO1. We characterize the purified protein and assess its performance in vitro using one-photon excitation in cultured rat hippocampal neurons, in vivo using one-photon excitation fiber photometry in mice, and ex vivo using two-photon Ca2+ imaging in hippocampal slices. Results: The Ca2+-bound state of T-GECO1 has an excitation peak maximum of 468 nm, an emission peak maximum of 500 nm, an extinction coefficient of 49,300 M-1cm-1, a quantum yield of 0.83, and two-photon brightness approximately double that of EGFP. The Ca2+-dependent fluorescence increase is 15-fold and the apparent Kd for Ca2+ is 82 nM. With two-photon excitation conditions at 850 nm, T-GECO1 consistently enabled detection of action potentials with higher signal-to-noise (SNR) than a late generation GCaMP variant. Conclusion: T-GECO1 is a high performance blue-shifted GECI that, under two-photon excitation conditions, provides advantages relative to late generation GCaMP variants.

6.
bioRxiv ; 2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-37425831

RESUMO

Intracellular levels of the amino acid aspartate are responsive to changes in metabolism in mammalian cells and can correspondingly alter cell function, highlighting the need for robust tools to measure aspartate abundance. However, comprehensive understanding of aspartate metabolism has been limited by the throughput, cost, and static nature of the mass spectrometry based measurements that are typically employed to measure aspartate levels. To address these issues, we have developed a GFP-based sensor of aspartate (jAspSnFR3), where the fluorescence intensity corresponds to aspartate concentration. As a purified protein, the sensor has a 20-fold increase in fluorescence upon aspartate saturation, with dose dependent fluorescence changes covering a physiologically relevant aspartate concentration range and no significant off target binding. Expressed in mammalian cell lines, sensor intensity correlated with aspartate levels measured by mass spectrometry and could resolve temporal changes in intracellular aspartate from genetic, pharmacological, and nutritional manipulations. These data demonstrate the utility of jAspSnFR3 and highlight the opportunities it provides for temporally resolved and high throughput applications of variables that affect aspartate levels.

7.
Nat Methods ; 20(6): 925-934, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37142767

RESUMO

The fluorescent glutamate indicator iGluSnFR enables imaging of neurotransmission with genetic and molecular specificity. However, existing iGluSnFR variants exhibit low in vivo signal-to-noise ratios, saturating activation kinetics and exclusion from postsynaptic densities. Using a multiassay screen in bacteria, soluble protein and cultured neurons, we generated variants with improved signal-to-noise ratios and kinetics. We developed surface display constructs that improve iGluSnFR's nanoscopic localization to postsynapses. The resulting indicator iGluSnFR3 exhibits rapid nonsaturating activation kinetics and reports synaptic glutamate release with decreased saturation and increased specificity versus extrasynaptic signals in cultured neurons. Simultaneous imaging and electrophysiology at individual boutons in mouse visual cortex showed that iGluSnFR3 transients report single action potentials with high specificity. In vibrissal sensory cortex layer 4, we used iGluSnFR3 to characterize distinct patterns of touch-evoked feedforward input from thalamocortical boutons and both feedforward and recurrent input onto L4 cortical neuron dendritic spines.


Assuntos
Ácido Glutâmico , Transmissão Sináptica , Camundongos , Animais , Ácido Glutâmico/metabolismo , Cinética , Neurônios/fisiologia , Sinapses/fisiologia
8.
PLoS Biol ; 20(9): e3001772, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36067248

RESUMO

Potassium ion (K+) plays a critical role as an essential electrolyte in all biological systems. Genetically-encoded fluorescent K+ biosensors are promising tools to further improve our understanding of K+-dependent processes under normal and pathological conditions. Here, we report the crystal structure of a previously reported genetically-encoded fluorescent K+ biosensor, GINKO1, in the K+-bound state. Using structure-guided optimization and directed evolution, we have engineered an improved K+ biosensor, designated GINKO2, with higher sensitivity and specificity. We have demonstrated the utility of GINKO2 for in vivo detection and imaging of K+ dynamics in multiple model organisms, including bacteria, plants, and mice.


Assuntos
Técnicas Biossensoriais , Transferência Ressonante de Energia de Fluorescência , Animais , Técnicas Biossensoriais/métodos , Transferência Ressonante de Energia de Fluorescência/métodos , Íons , Camundongos , Potássio
9.
Nat Commun ; 12(1): 7058, 2021 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-34873165

RESUMO

L-Lactate, traditionally considered a metabolic waste product, is increasingly recognized as an important intercellular energy currency in mammals. To enable investigations of the emerging roles of intercellular shuttling of L-lactate, we now report an intensiometric green fluorescent genetically encoded biosensor for extracellular L-lactate. This biosensor, designated eLACCO1.1, enables cellular resolution imaging of extracellular L-lactate in cultured mammalian cells and brain tissue.


Assuntos
Proteínas de Bactérias/metabolismo , Técnicas Biossensoriais/métodos , Proteínas de Fluorescência Verde/metabolismo , Ácido Láctico/análise , Proteínas Periplásmicas/metabolismo , Proteínas Recombinantes de Fusão/metabolismo , Proteínas de Bactérias/genética , Sítios de Ligação/genética , Linhagem Celular Tumoral , Cristalografia por Raios X , Fluorescência , Proteínas de Fluorescência Verde/química , Proteínas de Fluorescência Verde/genética , Células HEK293 , Células HeLa , Humanos , Ácido Láctico/metabolismo , Microscopia de Fluorescência , Proteínas Periplásmicas/genética , Ligação Proteica , Proteínas Recombinantes de Fusão/química , Proteínas Recombinantes de Fusão/genética , Reprodutibilidade dos Testes
10.
PLoS Biol ; 18(11): e3000965, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33232322

RESUMO

Near-infrared (NIR) genetically encoded calcium ion (Ca2+) indicators (GECIs) can provide advantages over visible wavelength fluorescent GECIs in terms of reduced phototoxicity, minimal spectral cross talk with visible light excitable optogenetic tools and fluorescent probes, and decreased scattering and absorption in mammalian tissues. Our previously reported NIR GECI, NIR-GECO1, has these advantages but also has several disadvantages including lower brightness and limited fluorescence response compared to state-of-the-art visible wavelength GECIs, when used for imaging of neuronal activity. Here, we report 2 improved NIR GECI variants, designated NIR-GECO2 and NIR-GECO2G, derived from NIR-GECO1. We characterized the performance of the new NIR GECIs in cultured cells, acute mouse brain slices, and Caenorhabditis elegans and Xenopus laevis in vivo. Our results demonstrate that NIR-GECO2 and NIR-GECO2G provide substantial improvements over NIR-GECO1 for imaging of neuronal Ca2+ dynamics.


Assuntos
Cálcio/metabolismo , Imagem Óptica/métodos , Animais , Encéfalo/metabolismo , Caenorhabditis elegans/metabolismo , Corantes Fluorescentes , Proteínas de Fluorescência Verde/química , Proteínas de Fluorescência Verde/genética , Células HeLa , Humanos , Indicadores e Reagentes , Proteínas Luminescentes/química , Proteínas Luminescentes/genética , Camundongos , Miócitos Cardíacos/metabolismo , Neurônios/metabolismo , Optogenética , Engenharia de Proteínas , Espectroscopia de Luz Próxima ao Infravermelho , Xenopus laevis/metabolismo
11.
ACS Sens ; 5(7): 1959-1968, 2020 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-32571014

RESUMO

Genetically encodable calcium ion (Ca2+) indicators (GECIs) based on green fluorescent proteins (GFP) are powerful tools for imaging of cell signaling and neural activity in model organisms. Following almost 2 decades of steady improvements in the Aequorea victoria GFP-based GCaMP series of GECIs, the performance of the most recent generation (i.e., jGCaMP7) may have reached its practical limit due to the inherent properties of GFP. In an effort to sustain the steady progression toward ever-improved GECIs, we undertook the development of a new GECI based on the bright monomeric GFP, mNeonGreen (mNG). The resulting indicator, mNG-GECO1, is 60% brighter than GCaMP6s in vitro and provides comparable performance as demonstrated by imaging Ca2+ dynamics in cultured cells, primary neurons, and in vivo in larval zebrafish. These results suggest that mNG-GECO1 is a promising next-generation GECI that could inherit the mantle of GCaMP and allow the steady improvement of GECIs to continue for generations to come.


Assuntos
Cálcio , Neurônios , Peixe-Zebra , Animais , Linhagem Celular , Células Cultivadas , Peixe-Zebra/genética
12.
Nat Methods ; 17(7): 694-697, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32451475

RESUMO

Femtosecond lasers at fixed wavelengths above 1,000 nm are powerful, stable and inexpensive, making them promising sources for two-photon microscopy. Biosensors optimized for these wavelengths are needed for both next-generation microscopes and affordable turn-key systems. Here we report jYCaMP1, a yellow variant of the calcium indicator jGCaMP7 that outperforms its parent in mice and flies at excitation wavelengths above 1,000 nm and enables improved two-color calcium imaging with red fluorescent protein-based indicators.


Assuntos
Cálcio/análise , Corantes Fluorescentes/química , Microscopia de Fluorescência por Excitação Multifotônica/métodos , Animais , Drosophila , Feminino , Lasers , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Imagem Molecular , Córtex Somatossensorial/química
13.
Curr Probl Diagn Radiol ; 49(6): 431-446, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31307863

RESUMO

Endometrial abnormalities develop in female patients of all ages. Symptoms related to endometrial pathologies are among the most common causes of gynecologist office visits, with the radiologists playing an important role in endometrial evaluation. In some instances, the radiologist may be the first physician to note endometrial pathology. In this article, we will provide a comprehensive review of radiologic modalities utilized in the evaluation of the endometrium, as well as the imaging appearance of various endometrial disease processes.


Assuntos
Imagem Multimodal , Doenças Uterinas/diagnóstico por imagem , Diagnóstico Diferencial , Endométrio/anatomia & histologia , Feminino , Humanos , Doenças Uterinas/patologia
14.
Commun Biol ; 2: 18, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30652129

RESUMO

Potassium ion (K+) homeostasis and dynamics play critical roles in biological activities. Here we describe three genetically encoded K+ indicators. KIRIN1 (potassium (K) ion ratiometric indicator) and KIRIN1-GR are Förster resonance energy transfer (FRET)-based indicators with a bacterial K+ binding protein (Kbp) inserting between the fluorescent protein FRET pairs mCerulean3/cp173Venus and Clover/mRuby2, respectively. GINKO1 (green indicator of K+ for optical imaging) is a single fluorescent protein-based K+ indicator constructed by insertion of Kbp into enhanced green fluorescent protein (EGFP). These indicators are suitable for detecting K+ at physiologically relevant concentrations in vitro and in cells. KIRIN1 enabled imaging of cytosolic K+ depletion in live cells and K+ efflux and reuptake in cultured neurons. GINKO1, in conjunction with red fluorescent Ca2+ indicator, enable dual-color imaging of K+ and Ca2+ dynamics in neurons and glial cells. These results demonstrate that KIRIN1 and GINKO1 are useful tools for imaging intracellular K+ dynamics.


Assuntos
Cátions Monovalentes/metabolismo , Citosol/metabolismo , Proteínas de Fluorescência Verde/genética , Proteínas de Fluorescência Verde/metabolismo , Potássio/metabolismo , Cálcio/metabolismo , Proteínas de Transporte/genética , Escherichia coli/metabolismo , Proteínas de Escherichia coli/genética , Transferência Ressonante de Energia de Fluorescência/métodos , Corantes Fluorescentes/metabolismo , Células HeLa , Humanos , Íons , Proteínas Luminescentes/metabolismo , Microscopia de Fluorescência/métodos , Concentração Osmolar , Plasmídeos/genética , Proteína Vermelha Fluorescente
15.
J Digit Imaging ; 29(6): 654-657, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-26957291

RESUMO

This paper describes the design and implementation of an application that parses and analyzes radiology report text to provide a radiologic differential diagnosis. The system was constructed using a combination of freely available web-based APIs and originally developed during the Society for Imaging Informatics in Medicine (SIIM) 2014 Hackathon. Continued development has refined and increased the accuracy of the algorithm. This project demonstrates the power and possibilities of combining existing technologies to solve unique problems as well as the stimulus of the hackathon setting to spur innovation.


Assuntos
Algoritmos , Diagnóstico por Computador , Diagnóstico Diferencial , Técnicas de Apoio para a Decisão , Humanos , Radiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...