Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Transfus Apher Sci ; 63(3): 103937, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38678985

RESUMO

BACKGROUND: For assessment of COVID-19 vaccine efficacy, neutralization activity of anti-SARS-CoV-2 antibody is measured. This study was undertaken to determine optimum levels of binding antibody units (BAU/ml) in new quantitative chemiluminescent assay (CLIA) that corresponded to neutralizing potential (30% inhibition) of sVNT assay. METHODS: Ninety-one blood samples were analyzed by CLIA and sVNT assays. Test samples (n = 75) were collected from blood donors post-2nd vaccination dose, while control samples (n = 16) were archived pre-COVID donor samples. Correlation between CLIA and sVNT was calculated and receiver operating characteristic (ROC) curve was drawn and analyzed. RESULTS: Results indicated excellent correlation between 57.5 BAU/ml on CLIA and 30%inhibition on sVNT assay. ROC curve analysis revealed that the area under the curve (AUC) was 0.971. DISCUSSION: The present study determined that 57.5 BAU/ml on CLIA corresponded to 30% inhibition on sVNT assay. Periodic quantitative analysis.


Assuntos
Anticorpos Antivirais , Doadores de Sangue , Vacinas contra COVID-19 , COVID-19 , Medições Luminescentes , SARS-CoV-2 , Humanos , COVID-19/prevenção & controle , COVID-19/sangue , COVID-19/imunologia , SARS-CoV-2/imunologia , Vacinas contra COVID-19/imunologia , Medições Luminescentes/métodos , Anticorpos Antivirais/sangue , Masculino , Feminino , Vacinação/métodos , Anticorpos Neutralizantes/sangue
2.
Transfus Apher Sci ; 63(1): 103862, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38135545

RESUMO

BACKGROUND AND OBJECTIVES: ABO-incompatible transplantations allow patients to receive timely transplants. Isoagglutinin titration to ascertain levels of incompatible antibodies in the recipient is important in determining patient selection and transplant survivability. To find out the prevalent trends in India, the largest, first of its kind survey was carried out among the transplant centers regarding their practices in isoagglutinin titration. METHODS: The survey was drafted by a working group of Transfusion and Transplant Immunology specialists from six different centers. Data was obtained via the use of an online questionnaire. RESULTS: Results were categorized into four categories, Hospital information, Titration methodology, Role of transfusion specialists and cut-off titers. Most centers had a well-established solid-organ transplant program with considerable number of ABO-incompatible transplantations. Most centers performed isoagglutinin titration in Transfusion Medicine department. Column Agglutination Technique (CAT) was the most common method, using EDTA blood samples and freshly-prepared in-house pooled cells. Most centers had a turn-around time of less than 12 h. While the policy for ascertaining baseline and threshold titers is well-defined in ABO-incompatible renal transplants, variations from center to center still exist for ABO-incompatible liver transplants. Most centers required a Transfusion Medicine consultation for the patients before such transplants. CONCLUSION: With increasing ABO-incompatible kidney and liver transplants across the country, the role of Transfusion medicine specialists has become vital in pre-conditioning regimes enabling the viability and success of such transplants. This was a unique survey that provided a snapshot of current trends and practices of isoagglutinin titration for ABO-incompatible transplants in India.


Assuntos
Transplante de Rim , Transplante de Fígado , Transplante de Órgãos , Humanos , Incompatibilidade de Grupos Sanguíneos , Transplante de Rim/métodos , Rim , Sistema ABO de Grupos Sanguíneos
3.
J Obstet Gynaecol India ; 73(Suppl 2): 281-283, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38143996

RESUMO

'G' antigen belongs to the Rh family and it was first described by Allen and Tippet in 1958. Various anti-D, anti-C, and anti-G antibody combinations can be found in patients. Ruling out the presence of anti-D is important for administering RhIg prophylaxis in RhD-negative pregnant women to prevent hemolytic disease of fetus and newborn (HDFN). RhIg prophylaxis is not indicated in the presence of an anti-D antibody. Time-to-time monitoring and follow-up of cases of RhD-negative pregnant women with a multi-disciplinary approach including an obstetrician, neonatologist, and transfusion medicine specialist helps diagnose, manage, and monitor HDFN in such cases. This case report emphasizes the need for proper antibody identification (anti-G) and managing HDFN (with intrauterine transfusions and exchange transfusion) during the perinatal period.

4.
Transpl Immunol ; 81: 101931, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37730185

RESUMO

"In solid organ transplantation, the compatibility between recipient and donor relies on testing prior to transplantation as a major determinant for the successful transplant outcomes. This compatibility testing depends on the detection of donor-specific antibodies (DSAs) present in the recipient. Indeed, sensitized transplant candidates are at higher risk of allograft rejection and graft loss compared to non-sensitized individuals. Most of the laboratories in India have adopted test algorithms for the appropriate risk stratification of transplants, namely: 1) donor cell-based flow-cytometric cross-match (FCXM) assay with patient's serum to detect DSAs; 2) HLA-coated beads to detect anti-HLA antibodies; and 3) complement-dependent cytotoxicity crossmatch (CDCXM) with donor cells to detect cytotoxic antibodies. In the risk stratification strategy, laboratories generally accept a DSA median fluorescence index (MFI) of 1000 MFI or lower MFI (low-MFI) as a negative value and clear the patient for the transplant. We present two cases of live-related donor kidney transplants (LDKTs) with low-MFI pre-transplant DSA values who experienced an early acute antibody-mediated rejection (ABMR) as a result of an anamnestic antibody response by DSA against HLA class II antibodies. These results were confirmed by retesting of both pre-transplant and post-transplant archived sera from patients and freshly obtained donor cells. Our examples indicate a possible ABMR in patients with low MFI pre-transplant DSA. Reclassification of low vs. high-risk may be appropriate for sensitized patients with low-MFI DSA."


Assuntos
Transplante de Rim , Humanos , Antígenos HLA , Anticorpos , Doadores de Tecidos , Teste de Histocompatibilidade/métodos , Rim , Rejeição de Enxerto , Isoanticorpos , Estudos Retrospectivos
5.
Asian J Transfus Sci ; 17(1): 79-84, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37188030

RESUMO

BACKGROUND: Therapeutic plasma exchange (TPE) has been advocated as an adjunct to steroids and cytotoxic drugs in treating patients suffering from vasculitis and presenting with active disease, but we still have insufficient evidence on its effectiveness in improving the clinical response, especially in India. This study was planned to study the clinical outcome in severe vasculitic presentations treated with TPE as an adjunctive therapy. MATERIALS AND METHODS: A retrospective analysis of TPE procedures performed from July 2013 to July 2017 in the department of transfusion medicine at a large tertiary care hospital was done. All consecutive patients admitted with new diagnosis of systemic vasculitis presenting with active disease and severe presentations such as advanced renal failure or severe respiratory abnormalities or life-threatening vasculitis affecting the gastrointestinal tract, neurological and musculoskeletal system; who needed TPE for removal of preformed antibodies, were included in the study. RESULTS: There were a total of 31 patients in whom TPE was performed for severe systemic vasculitis; 26 adults and five pediatric. Six patients tested positive for perinuclear fluorescence, 13 for cytoplasmic fluorescence (cANCA), two for atypical antineutrophil cytoplasmic autoantibody, seven for anti-glomerular basement membrane antibodies, two for antinuclear antibodies (ANA), and one patient tested positive for ANA as well as cANCA before the augmentation of TPE. Out of 31, seven patients showed no clinical improvement and succumbed to the disease. At the end of desired number of procedures, 19 tested negative and five tested weak positive for their respective antibodies. CONCLUSION: Favorable clinical outcomes were observed with TPE in patients with antibody-positive systemic vasculitis.

6.
Indian J Hematol Blood Transfus ; 39(2): 300-307, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37006975

RESUMO

While whole blood testing has evolved over the years, viral marker testing for plateletpheresis donors is still performed by Rapid Diagnostic Tests (RDT). Aim of this study was to compare diagnostic accuracy of RDT and Chemiluminescence Immunoassay (CLIA) in serological testing for HBsAg, anti-HCV and anti-HIV antibodies. A prospective, analytical study was conducted in the department of Transfusion Medicine at a tertiary healthcare center in India between September 2016 and August 2018. Samples were simultaneously tested by CLIA, RDT and a confirmatory test. Sensitivity, specificity, negative and positive predictive values and mean time taken to report results were calculated. A total of 102 (1.48%) of the 6883 samples were found to be reactive by either or both the assays. A total of 74 (1.08%) samples were HBsAg reactive, 23 (0.33%) were reactive for anti-HCV antibodies and 5 (0.07%) were reactive for anti-HIV I and II antibodies. A combined sero-prevalence of 1.05% (72) was observed; 0.78% (54) for HBsAg, 0.26% (18) for anti-HCV antibodies and none for anti-HIV I and II antibodies. Four (3.85%) reactive samples were missed by RDT and therefore sensitivity of RDT was quite less as compared to CLIA. RDT and CLIA both were found to have a statistically significant shorter turnaround time than confirmatory tests. There is increasing need to develop a safe donor screening strategy for plateletpheresis. CLIA offers an excellent alterative to RDT for viral marker testing in terms of sensitivity.

7.
Transpl Immunol ; 78: 101802, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36868325

RESUMO

INTRODUCTION: Renal transplantation is the treatment of choice for patients suffering from end stage renal disease (ESRD). Indian regulations defined under Transplantation of Human Organs and Tissues Act (THOTA), 2014 restricts organ donations to near-related living donors to curb any malpractices like 'paid donors' in living-donor kidney transplantation (LDKT). The aim of our study was to look at real-world data of donor-recipient pairs and to identify relationship of donors (with their respective patients) and the common (or uncommon) DNA profiling methods used for supporting "claimed relationship" in accordance with the regulations. MATERIAL AND METHODS: The donors were categorized and grouped into near-related donor, donors other than near-related donors, swap donors and deceased donors. Claimed relationship was confirmed, commonly by HLA typing, using SSOP method. In few cases, which were uncommon (and infrequent), autosomal DNA analysis, mitochondrial DNA analysis and Y-STR DNA analysis were performed to support the claimed relationship. Data collected included age, gender, relationship, DNA profiling test method. RESULTS: Among the 514 donor-recipient pairs evaluated, numbers of female donors out-numbered male donors. The decreasing order of relationships in near-related donor group were wife>mother>father>sister>son>brother>husband> daughter>grandmother. 11.9% of donors were in the category of donors other than near-related donors. In 97.86% cases, the claimed relationship was supported by HLA typing and in just 2.1% cases autosomal DNA analysis>mitochondrial DNA analysis> Y-STR DNA analysis, in this order, were performed to establish relationship. CONCLUSION: This study brought out gender disparity with women out-numbering men as donors. Among recipients, access to renal transplant was largely restricted to men. As far as relationship of donors to recipients was concerned, mostly near-related family members, like wife, were donors and claimed relationship was almost always (99%) was corroborated by HLA typing.


Assuntos
Transplante de Rim , Humanos , Masculino , Feminino , Estudos Retrospectivos , Centros de Atenção Terciária , Doadores Vivos , Índia , DNA
8.
Asian J Transfus Sci ; 17(2): 256-263, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38274958

RESUMO

The International Society of Blood Transfusion (ISBT) 128 is an internationally endorsed, electronically readable labeling standard that provides a convenient and accurate means of identification, traceability, publication, and storage of information for blood and blood products. The authors' center recently registered with the International Council for Commonality in Blood Banking Automation (ICCBBA) and progressed to ISBT 128 labeling standard. This manuscript was written with the objective of sharing the authors' experience with respect to the implementation of ISBT 128 standards for whole blood donations and integration of ISBT 128 standards with Indian licensing regulations. The authors explore the process of implementation of ISBT 128 standards through a step-by-step journey that included facility registration with International Council for Commonality in Blood Banking Automation (ICCBBA), allotment of facility identification number, development of four-quadrant label for blood components, and integration of local regulatory requirements in the final "composite" label. Acknowledging the lack of any published report from India on ISBT 128 standards implementation, the authors wish to attempt help their peers in understanding and implementation of this global standard at their respective facilities.

9.
Asian J Transfus Sci ; 17(2): 175-181, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38274959

RESUMO

INTRODUCTION: HIV fourth-generation assay, designed for the detection of HIV p24 antigen along with anti-HIV antibodies of both immunoglobulin M and immunoglobulin G type against HIV 1 and HIV 2 viral antigens, have helped in the early detection of HIV infection and supports in minimizing the transmission risk in the acute phase of infection. The objective of this study was to evaluate the analytical and clinical performance of HIV fourth-generation assay based on enhanced chemiluminescence technology. MATERIALS AND METHODS: The analytical performance of the assay was evaluated in terms of accuracy, precision, limit of detection, type of sample (serum vs. plasma), cross-reactivity (with other transfusion transmissible infections markers), and interference (with endogenous substances). Proficiency control material included kit-controls, archived known positive donor samples, third-party controls, and World Health Organization (WHO)/National Institute for Biological Standards and Controls (NIBSC, MHRA, UK) controls. The clinical performance was evaluated using routine donor and patient samples received during the study period. RESULTS: HIV fourth-generation assay showed reliable and reproducible results measured in terms of coefficient of variation % with kit-controls, archived known positive donor samples, third-party controls, and WHO international standards for anti-HIV 1 and 2 antibodies, HIV1 p24 antigens and HIV2 p26 antigen controls. The analytical sensitivity of the HIV fourth-generation assay was found to be 0.1 IU/mL of HIV1 p24 antigen control and there was no cross-reactivity or interference observed. In the clinical performance of the assay, HIV fourth-generation assay showed reliable performance in both donor and patient samples. CONCLUSION: HIV fourth-generation assay meets the requirements for its use as a screening assay for HIV infection based on the analytical and clinical performance of the assay.

10.
Asian J Transfus Sci ; 17(2): 195-201, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38274967

RESUMO

BACKGROUND AND OBJECTIVES: Enumeration of hematopoietic progenitor cell (HPC) is vital to decide the time to initiate harvest (TTIH) and adequacy of harvest dose (AOHD). Standard of care used for HPC enumeration is flowcytometric CD34+ enumeration, but it is expensive, time-consuming and requires skilled staff to perform the test. Alternatively, HPC-count by advanced automated cell analyzer is cheaper, quicker, and easy-to-perform test. Our objective was to find a correlation of HPC count with CD34+ enumeration in leukapheresis. MATERIALS AND METHODS: An observational, prospective study was conducted in the year 2018-2019. A total of 126 samples were included in the study, the peripheral blood (PB) group comprised of 42samples and apheresis group of 84 samples. The samples were simultaneously tested for CD34+ expression and complete blood count which included the HPC count, white blood cells (WBC) count and multinational corporation (MNC) count and correlation analysis was performed with CD34+ flowcytometric count. The cut-off of PB HPC count for the target dose of 5 × 106 CD34+ cells/kg was established using Receiver Operator Curve. RESULTS: The correlation coefficient (r) of HPC with CD34+ count was 0.617 and 0.699 for PB group and apheresis group sample respectively, which was statistically significant. The correlation with MNC and WBC count was not very significant. A cut-off value of PB HPC was established to be 66 HPC/µl with a positive predictive value of 94.12%. The cost of CD34 + flow cytometric enumeration was six times that of HPC enumeration by analyzer. CONCLUSION: The HPC count is a cheaper, rapid and easy test and can be clinically applied to predict TTIH and AOHD but requires more studies to validate its efficacy in clinical use.

11.
Indian J Pathol Microbiol ; 65(1): 111-116, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35074974

RESUMO

BACKGROUND: : Many biomarkers have now been studied such as C-reactive Protein (CRP), procalcitonin (PCT), etc., and are widely used for the diagnosis of sepsis in clinical practice which may determine the appropriate antibiotic treatment. A flowcytometric cytokine bead array (CBA) assay has now been used to determine multiple interleukins (IL), simultaneously. The aim of this study was to determine the cytokine (IL2, IL4, IL6, IL10, TNFα, INFγ, and IL17) profiles of interleukins in plasma of sepsis patients by using multiplex Flowcytometric CBA array assay. MATERIALS AND METHOD: s: A total of 99 consecutive patients admitted with the suspected sepsis were studied. PCT concentrations were measured by using the enzyme-linked fluorescent immunoassay (ELFA) technique and flow cytometry-based BD™ CBA Cytokine Kit was used to evaluate levels of 7 cytokines [IL-2, IL-4, IL-6, IL-10, Tumour Necrosis Factor (TNF), Interferon- γ (IFN-γ), and IL-17A]. RESULTS: Microbiologically defined infection (MDI) demonstrated a positive culture report in 79/99 (79.7%) of patients. The IL6 [1873.7 (4-5000)] and IL10 [(154.7 (0-1764)] levels were significantly higher in septic patients than those in the negative MDI IL6 [901 (4-5000)] and IL10 [110.4 (4-1372)] levels. The AUROC value of IL6 [0.66 (0.53-0.79)] was found to be the highest among all followed by IL10 [0.65 (0.51-0.79)], IFNγ [0.63 (0.51-0.77)], PCT [0.61 (0.48-0.75)], and TNFα [0.55 (0.42-0.69)]. CONCLUSION: Our study suggests that that IL6 is substantially more economical and can reduce the investigation cost to half as compared with the procalcitonin assay.


Assuntos
Técnicas de Laboratório Clínico/métodos , Técnicas de Laboratório Clínico/normas , Interleucinas/sangue , Pró-Calcitonina/sangue , Sepse/diagnóstico , Biomarcadores/sangue , Estado Terminal , Humanos , Curva ROC , Sepse/imunologia , Atenção Terciária à Saúde/estatística & dados numéricos
12.
Asian J Transfus Sci ; 16(2): 245-250, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36687539

RESUMO

BACKGROUND: In clinical practice, laboratory results are of great importance for the diagnosis and treatment. Reference intervals of different parameters aid health-care professionals in the interpretation of results. There are very few studies on reference intervals from India. This prospective study was conducted to determine the reference intervals for platelet count (PLT) and PLT indices; mean PLT volume (MPV), PLT distribution width (PDW), and PLT large cell ratio (P-LCR). These values can be obtained as a part of a routine complete blood count (CBC) and have diagnostic and prognostic significance in certain diseases. PLT count is an important criterion for the selection of donors for repeat plateletpheresis donation. MATERIALS AND METHODS: Sixteen hundred and thirty-four first-time healthy volunteer plateletpheresis donors were enrolled for the study. CBC was done, values of PLT, MPV, PDW, and P-LCR were noted, and the results were analyzed. The 95% of the reference distribution was estimated using the 2.5th and 97.5th percentiles following Clinical and Laboratory Standards Institute guidelines. Adverse donor reactions, if any and quality parameters of single donor PLTs (SDP) were also studied. RESULTS: Reference range values of PLT, MPV, PDW, and P-LCR were 137,825-355,175/µl, 8.1-13.9/fl, 9.1-22.5/fl, and 11.7%-52.9%, respectively, and compared well with other published studies from India. It was observed that reference values of PLT count obtained in the study were lower than reference values that are currently used in most laboratories (150,000-450,000/µl) in India. CONCLUSION: Based on our results, we are of the opinion that the PLT count cutoffs for repeat plateletpheresis donation may need to be revised downwards for our country which would also mitigate the scarcity of apheresis donors.

13.
Transfus Apher Sci ; 60(6): 103261, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34538569

RESUMO

BACKGROUND: Random Donor Platelet (RDP) derived from whole blood is the major source of platelets in India. At our centre, we prepare RDPs by buffy coat method after a holding period of 2-hours (THRDP) as per current regulatory guidelines. Overnight hold of buffy coats before RDP preparation (OHRDP) would logistically optimise the manpower usage at our centre. The aim of this study was to compare both in-vitro as well as in-vivo parameters of OHRDPs with THRDPs. METHODOLOGY: Hematological (Platelet, leucocyte counts), physical (pH and Swirling) and biochemical parameters (pO2, pCO2, lactate, bicarbonate and glucose) as well as platelet activation markers were tested in THRDPs and OHRDPs each at Day-1 and Day-5 as in-vitro studies. Separately, in-vivo study was done where Corrected count increment (CCI) and percentage platelet recovery (PPR) were considered. All parameters were expressed as Mean ± Standard deviation and were analysed using paired t-test with level of significance, p < 0.05. RESULTS: OHRDPs had higher platelet counts and lower leucocytes and CD62 P expression than THRDPs. All other markers were well within the quality control range in both groups. No significant differences were seen in the two groups when comparing CCI and PPR. CONCLUSION: OHRDPs were found to be as good or better as compared to the THRDPs in the in-vitro part of our study. Additionally, there were no significant differences between the two groups when they were compared in vivo. This makes us conclude that overnight hold of buffy coats may be implemented at our center.


Assuntos
Plaquetas/metabolismo , Preservação de Sangue/métodos , Ativação Plaquetária/fisiologia , Adulto , Feminino , Humanos , Índia , Masculino , Estudos Prospectivos , Doadores de Tecidos , Adulto Jovem
14.
ISBT Sci Ser ; 16(4): 269-275, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34548879

RESUMO

Background and Objectives: There are limited published data on association of results from commercial serological anti-SARS-CoV-2 IgG antibody CLIA (chemiluminescent immunoassay) assays with neutralizing antibodies. This study was undertaken with an objective to correlate sample-to-cut-off (S/Co) ratio of CLIA antibody tests with inhibition activity, which may then serve as a valuable guide for labelling plasma as COVID convalescent plasma (CCP) for therapy and assessing vaccine efficacy. Materials and Methods: A total of 139 donor serum samples who were previously RT-PCR positive and had recovered completely from COVID-19 at least 28 days prior to collection of samples were recruited at three sites. The samples were analysed for S/Co ratio and per cent inhibition activity with VITROS SARS-CoV-2 IgG chemiluminescent assay and GenScript cPass SARS-CoV-2 Surrogate Virus Neutralization Test (sVNT) kit, respectively. Linear regression equation and receiver operating characteristic (ROC) curve were used to check the proposed model of comparing S/Co with per cent inhibition. Results: The results indicate very good correlation between the S/Co ratio of the chemiluminescent IgG assay and the neutralization activity depicted by per cent inhibition on sVNT assay. S/Co ratio of 4·04 (low-titre) and 8·19 (high-titre) correlated with 30% and 68% inhibition, respectively. Conclusion: Chemiluminescent SARS-CoV-2 IgG assay can be used as a semi-quantitative test, with a cut-off of >8·19S/Co ratio for selecting donors for convalescent plasma therapy and assessing efficacy of vaccination.

15.
Indian J Nephrol ; 31(3): 240-244, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34376937

RESUMO

INTRODUCTION: Solid organ transplantation is the preferred therapeutic modality of treatment in patients affected by terminal organ failures. Human leukocyte antigens (HLAs) plays an important role in graft survival. In many of the cases of rejection, antibodies are directed against HLA antigens expressed on the cells of the transplanted organ. Pre-transplant compatibility testing involves the use of different methodologies for the determination of anti-HLA antibodies. Luminex single-antigen bead (SAB) assay demonstrates higher sensitivity and specificity in detecting anti-HLA antibodies. The aim of this study was to determine the prevalence of anti-HLA antibodies in pre-transplant work up recipients, planned for renal transplant at a tertiary care center in India. METHODS: 1640 patients visiting tertiary care hospital for pre-transplant compatibility testing were screened with complement-dependent micro-lymphocytotoxicity crossmatch (CDC-XM) and flow cytometric crossmatch (FC-XM). The patients positive for either or both screening tests were assayed with the Luminex SAB tests in order to establish defined antigen specificity of the alloantibodies and determining donor-specific antibody (DSA). RESULTS: The two most frequent antibodies identified in each A, B, C locus of HLA class I were -A*24:03 (43.9%), A*25:01 (36.6%), B*57:01 (40.3%), B*15:12 (37.1%), C*17:01 (61.9%), C*07:01 (52.4%) and in DR, DQ DP locus in HLA class II were DRB1*09:01(40.0%), DRB1*14:04(37.6%), DQA1*04:01/DQB1*03:03 (58.4%), DQA1*05:01/DQB1*03:01 (55.1%), DPA1*02:01/DPB1*17:01 (55.0%), DPA1*02:01/DPB1*05:01 (45.0%). CONCLUSION: This study has found the prevalence and specificity of anti-HLA antibodies in north India.

16.
Asian J Transfus Sci ; 15(1): 30-36, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34349454

RESUMO

BACKGROUND: As a part of continuous quality initiatives, while moving from triple bags to quadruple bags, we undertook a study to compare platelet-rich plasma (PRP) and buffy-coat (BC) methods with respect to all blood components (red blood cells [RBCs], random donor platelet concentrate [RDPC], and fresh frozen plasma [FFP]) prepared by PRP and BC methods. MATERIALS AND METHODS: It was a prospective analysis of different physical and quality parameters of RDPC, RBC, and FFP prepared out of 100 whole blood (WB) donations. Of these, 50 WB units were processed by PRP method using Triple bags and 50 WB units by BC method, using quadruple (top and bottom) bags, with an attached integral filter. RESULTS: RBC prepared by BC method had higher hematocrit (61.3 ± 1.91% vs. 56.03 ± 3.37%; P < 0.05) and lower white blood cell (WBC) contamination (6.3 × 104 ± 6.1 vs. 5.41 × 105 ± 2.5; P < 0.05) in comparison to prepared by PRP method. Higher PLT yield (7.67 × 1010 ± 1.8 vs. 6.47 × 1010 ± 1.5; P < 0.05) and lower WBC count (8.24 × 103 ± 1.1 vs. 1.5 × 104 ± 2.1; P < 0.05) was observed in RDPC prepared by BC method than PRP derived. CD62P expression was lower in RDPC prepared by BC method (31.46 ± 9.7%; P < 0.05) as compared to PRP method (43.35 ± 12.5%; P < 0.05). The BC method also resulted in increased plasma yield (210.56 ± 18.54 ml vs. 187.92 ± 12.93 ml; P < 0.05) in FFP in comparison to PRP method. CONCLUSION: The blood components produced from WB by the BC method have laboratory variables suggestive of superior quality than those produced by the PRP method.

17.
Asian J Transfus Sci ; 15(1): 109-112, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34349469

RESUMO

Anti-G antibody mimics the reactivity pattern of coexistent anti-D and anti-C. Differentiating between the two is significant in antenatal females where the decision to administer RhD prophylaxis is based on the presence or absence of anti-D antibody. The aim of reporting this serological challenge is to emphasize the need for phenotyping red cells for sourcing appropriate in house red cell reagents and to help transfusion services sharpen problem-solving skills. A 26-year-old pregnant female with a complicated obstetric history and a positive indirect antiglobulin test presented to the hospital for antenatal assessment at 24 weeks. A positive antibody screen warranted identification of the implicating antibodies. Since identification was suggestive of multiple alloantibodies whose specificities could not be confirmed, step-wise sequential adsorption and elution was required. Anti-D, anti-C, and anti-E antibodies were identified in patient plasma with titers of 1024, 4, and 32, respectively. The absence of anti-G was also confirmed. Multiple alloantibodies can pose a challenge to transfusion services. However, with the help of select cells, phenotyping, adsorption elution studies, and phenotyped donor units; solving complex serological cases can be accomplished.

18.
Cancer Rep (Hoboken) ; 4(6): e1408, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34245131

RESUMO

BACKGROUND AND AIM: We report here our experience of using pegylated granulocyte colony stimulating factor (peg-GCSF) for peripheral blood stem cell (PBSC) mobilization in children. METHODS AND RESULTS: A total of nine children suffering from high-risk/relapsed solid tumors were mobilized with chemotherapy and peg-GCSF (100 microgram/kg single dose). Mean age was 7.7 years (range 2-15 years).The mean time from peg-GCSF administration to PBSC harvest was 9.7 days. Adequate stem cells (median dose 26.9 million/kg) could be harvested in all children by a single apheresis procedure. No major adverse events observed. CONCLUSION: It is feasible and safe to mobilize PBSC with peg-GCSF in children with cancer.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Fator Estimulador de Colônias de Granulócitos/administração & dosagem , Mobilização de Células-Tronco Hematopoéticas/métodos , Transplante de Células-Tronco Hematopoéticas/métodos , Neoplasias/terapia , Células-Tronco de Sangue Periférico/fisiologia , Polietilenoglicóis/administração & dosagem , Adolescente , Criança , Pré-Escolar , Terapia Combinada , Feminino , Seguimentos , Humanos , Masculino , Neoplasias/patologia , Prognóstico , Proteínas Recombinantes/administração & dosagem , Estudos Retrospectivos
20.
Asian J Transfus Sci ; 14(1): 13-18, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33162699

RESUMO

BACKGROUND: There are no published reports on desensitization protocol for ABO-incompatible kidney transplants using Immuno-Adsorption (IA) plasmapheresis from India. IA offers certain advantages including processing of larger plasma volumes, quicker reduction of isoagglutinin titers and no requirement of replacement fluids. AIMS AND OBJECTIVES: Authors' center evaluated success of desensitization protocol, and graft/patient outcomes when IA procedures were performed for desensitization in adult and pediatric ABO-incompatible kidney transplant patients. METHODS: Patients undergoing ABO-incompatible kidney transplant with use of IA were evaluated at tertiary care center in north India. Patient records for 2-years were collated from hospital information system (HIS) and procedure forms. RESULTS: Sixteen IA procedures were performed in five patients who underwent successful ABO-incompatible kidney transplant. Initial isoagglutinin IgG titer ranged from 32-512. Mean number of IA procedures performed to achieve the desired pre-transplant IgG titer ≤8 was 3.2. New IA column was used for each patient (and re-used for the same patient, if needed, after sterilization with Low temperature steam of formaldehyde). Mean plasma volume processed during each IA procedure was 4.5 times. No adverse events were observed during any IA procedure. All patients achieved successful desensitization. All patients continue to do well clinically with mean follow-up period of 8.8 months. Although IA was expensive, it offered advantages like specificity, larger plasma volume processing with desired reduction in titer, no 'replacement fluid' requirements and no adverse events in present case series. CONCLUSION: IA plasmapheresis was universally successful in decreasing the ABO-isoagglutinin titers to desired level in all prospective ABO incompatible kidney transplant patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...