Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 61(15): 5529-46, 2016 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-27384459

RESUMO

The aim of this work was to track and verify the delivery of respiratory-gated irradiations, performed with three versions of TrueBeam linac, using a novel phantom arrangement that combined the OCTAVIUS(®) SRS 1000 array with a moving platform. The platform was programmed to generate sinusoidal motion of the array. This motion was tracked using the real-time position management (RPM) system and four amplitude gating options were employed to interrupt MV beam delivery when the platform was not located within set limits. Time-resolved spatial information extracted from analysis of x-ray fluences measured by the array was compared to the programmed motion of the platform and to the trace recorded by the RPM system during the delivery of the x-ray field. Temporal data recorded by the phantom and the RPM system were validated against trajectory log files, recorded by the linac during the irradiation, as well as oscilloscope waveforms recorded from the linac target signal. Gamma analysis was employed to compare time-integrated 2D x-ray dose fluences with theoretical fluences derived from the probability density function for each of the gating settings applied, where gamma criteria of 2%/2 mm, 1%/1 mm and 0.5%/0.5 mm were used to evaluate the limitations of the RPM system. Excellent agreement was observed in the analysis of spatial information extracted from the SRS 1000 array measurements. Comparisons of the average platform position with the expected position indicated absolute deviations of <0.5 mm for all four gating settings. Differences were observed when comparing time-resolved beam-on data stored in the RPM files and trajectory logs to the true target signal waveforms. Trajectory log files underestimated the cycle time between consecutive beam-on windows by 10.0 ± 0.8 ms. All measured fluences achieved 100% pass-rates using gamma criteria of 2%/2 mm and 50% of the fluences achieved pass-rates >90% when criteria of 0.5%/0.5 mm were used. Results using this novel phantom arrangement indicate that the RPM system is capable of accurately gating x-ray exposure during the delivery of a fixed-field treatment beam.


Assuntos
Radiometria/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Respiração , Humanos , Movimento (Física) , Aceleradores de Partículas , Imagens de Fantasmas , Dosagem Radioterapêutica , Fatores de Tempo
2.
Phys Med Biol ; 59(9): N49-63, 2014 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-24732210

RESUMO

This work investigated the differences between multileaf collimator (MLC) positioning accuracy determined using either log files or electronic portal imaging devices (EPID) and then assessed the possibility of reducing patient specific quality control (QC) via phantom-less methodologies. In-house software was developed, and validated, to track MLC positional accuracy with the rotational and static gantry picket fence tests using an integrated electronic portal image. This software was used to monitor MLC daily performance over a 1 year period for two Varian TrueBeam linear accelerators, with the results directly compared with MLC positions determined using leaf trajectory log files. This software was validated by introducing known shifts and collimator errors. Skewness of the MLCs was found to be 0.03 ± 0.06° (mean ±1 standard deviation (SD)) and was dependent on whether the collimator was rotated manually or automatically. Trajectory log files, analysed using in-house software, showed average MLC positioning errors with a magnitude of 0.004 ± 0.003 mm (rotational) and 0.004 ± 0.011 mm (static) across two TrueBeam units over 1 year (mean ±1 SD). These ranges, as indicated by the SD, were lower than the related average MLC positioning errors of 0.000 ± 0.025 mm (rotational) and 0.000 ± 0.039 mm (static) that were obtained using the in-house EPID based software. The range of EPID measured MLC positional errors was larger due to the inherent uncertainties of the procedure. Over the duration of the study, multiple MLC positional errors were detected using the EPID based software but these same errors were not detected using the trajectory log files. This work shows the importance of increasing linac specific QC when phantom-less methodologies, such as the use of log files, are used to reduce patient specific QC. Tolerances of 0.25 mm have been created for the MLC positional errors using the EPID-based automated picket fence test. The software allows diagnosis of any specific leaf that needs repair and gives an indication as to the course of action that is required.


Assuntos
Equipamentos e Provisões Elétricas , Erros de Configuração em Radioterapia , Radioterapia de Intensidade Modulada/instrumentação , Calibragem , Aceleradores de Partículas , Rotação , Software , Fatores de Tempo
3.
Pract Radiat Oncol ; 4(1): 43-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24621422

RESUMO

PURPOSE: The dose delivery accuracy of 30 clinical step and shoot intensity modulated radiation therapy plans was investigated using the single integrated multileaf collimator controller of the Varian Truebeam linear accelerator (linac) (Varian Medical Systems, Palo Alto, CA) and compared with the dose delivery accuracy on a previous generation Varian 2100CD C-Series linac. METHODS AND MATERIALS: Ten prostate, 10 prostate and pelvic node, and 10 head-and-neck cases were investigated in this study. Dose delivery accuracy on each linac was assessed using Farmer ionization chamber point dose measurements, 2-dimensional planar ionization chamber array measurements, and the corresponding Varian dynamic log files. Absolute point dose measurements, fluence delivery accuracy, leaf position accuracy, and the overshoot effect were assessed for each plan. RESULTS: Absolute point dose delivery accuracy increased by 1.5% on the Truebeam compared with the 2100CD linac. No improvement in fluence delivery accuracy between the linacs, at a gamma criterion of 3%/3 mm was measured using the 2-dimensional ionization chamber array, with median (interquartile range) gamma passing rates of 98.99% (97.70%-99.72%) and 99.28% (98.26%-99.75%) for the Truebeam and 2100CD linacs, respectively. Varian log files also showed no improvement in fluence delivery between the linacs at 3%/3 mm, with median gamma passing rates of 99.97% (99.93%-99.99%) and 99.98% (99.94%-100%) for the Truebeam and 2100CD linacs, respectively. However, log files revealed improved leaf position accuracy and fluence delivery at 1%/1 mm criterion on the Truebeam (99.87%; 99.78%-99.94%) compared with the 2100CD linac (97.87%; 91.93%-99.49%). The overshoot effect, characterized on the 2100CD linac, was not observed on the Truebeam. CONCLUSIONS: The integrated multileaf collimator controller on the Varian Truebeam improves clinical treatment delivery accuracy of step and shoot intensity modulated radiation therapy fields compared with delivery on a Varian C-series linac.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Aceleradores de Partículas/instrumentação , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Masculino , Neoplasias da Próstata/patologia , Dosagem Radioterapêutica
4.
Phys Med Biol ; 57(21): 6761-77, 2012 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-23032423

RESUMO

This study aims to evaluate the use of Varian radiotherapy dynamic treatment log (DynaLog) files to verify IMRT plan delivery as part of a routine quality assurance procedure. Delivery accuracy in terms of machine performance was quantified by multileaf collimator (MLC) position errors and fluence delivery accuracy for patients receiving intensity modulated radiation therapy (IMRT) treatment. The relationship between machine performance and plan complexity, quantified by the modulation complexity score (MCS) was also investigated. Actual MLC positions and delivered fraction of monitor units (MU), recorded every 50 ms during IMRT delivery, were extracted from the DynaLog files. The planned MLC positions and fractional MU were taken from the record and verify system MLC control file. Planned and delivered beam data were compared to determine leaf position errors with and without the overshoot effect. Analysis was also performed on planned and actual fluence maps reconstructed from the MLC control file and delivered treatment log files respectively. This analysis was performed for all treatment fractions for 5 prostate, 5 prostate and pelvic node (PPN) and 5 head and neck (H&N) IMRT plans, totalling 82 IMRT fields in ∼5500 DynaLog files. The root mean square (RMS) leaf position errors without the overshoot effect were 0.09, 0.26, 0.19 mm for the prostate, PPN and H&N plans respectively, which increased to 0.30, 0.39 and 0.30 mm when the overshoot effect was considered. Average errors were not affected by the overshoot effect and were 0.05, 0.13 and 0.17 mm for prostate, PPN and H&N plans respectively. The percentage of pixels passing fluence map gamma analysis at 3%/3 mm was 99.94 ± 0.25%, which reduced to 91.62 ± 11.39% at 1%/1 mm criterion. Leaf position errors, but not gamma passing rate, were directly related to plan complexity as determined by the MCS. Site specific confidence intervals for average leaf position errors were set at -0.03-0.12 mm for prostate and -0.02-0.28 mm for more complex PPN and H&N plans. For all treatment sites confidence intervals for RMS errors with the overshoot was set at 0-0.50 mm and for the percentage of pixels passing a gamma analysis at 1%/1 mm a confidence interval of 68.83% was set also for all treatment sites. This work demonstrates the successful implementation of treatment log files to validate IMRT deliveries and how dynamic log files can diagnose delivery errors not possible with phantom based QC. Machine performance was found to be directly related to plan complexity but this is not the dominant determinant of delivery accuracy.


Assuntos
Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Fracionamento da Dose de Radiação , Raios gama , Humanos , Masculino , Neoplasias/radioterapia , Aceleradores de Partículas , Posicionamento do Paciente , Imagens de Fantasmas , Controle de Qualidade , Planejamento da Radioterapia Assistida por Computador/normas , Erros de Configuração em Radioterapia , Radioterapia de Intensidade Modulada/instrumentação , Radioterapia de Intensidade Modulada/normas , Registros
5.
QJM ; 104(7): 589-97, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21421993

RESUMO

BACKGROUND: Flow-mediated dilatation (FMD) of the brachial artery is commonly measured as a surrogate marker of endothelial function. Its measurement is, however, technically demanding and reports regarding its reproducibility have not always been favourable. AIM: Two Type I diabetes and control group comparator studies were conducted to assess the reproducibility of FMD and to analyse blood flow data normally discarded during FMD measurement. DESIGN: The studies were sequential and differed only with regard to operator and ultrasound machine. Seventy-two subjects with diabetes and 71 controls were studied in total. METHODS: Subjects had FMD measured conventionally. Blood velocity waveforms were averaged over 10 pulses post forearm ischaemia and their component frequencies analysed using the wavelet transform, a mathematical tool for waveform analysis. The component frequencies were grouped into 11 bands to facilitate analysis. RESULTS: Subjects were well-matched between studies. In Study 1, FMD was significantly impaired in subjects with Type I diabetes vs. controls (median 4.35%, interquartile range 3.10-4.80 vs. 6.50, 4.79-9.42, P < 0.001). No differences were detected between groups in Study 2, however. However, analysis of blood velocity waveforms yielded significant differences between groups in two frequency bands in each study. CONCLUSION: This report highlights concerns over the reproducibility of FMD measures. Further work is required to fully elucidate the role of analysing velocity waveforms after forearm ischaemia.


Assuntos
Artéria Braquial/fisiopatologia , Diabetes Mellitus Tipo 2/fisiopatologia , Endotélio Vascular/fisiopatologia , Vasodilatação/fisiologia , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Artéria Braquial/diagnóstico por imagem , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Microcirculação/fisiologia , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional/fisiologia , Reprodutibilidade dos Testes , Ultrassonografia
6.
Med Eng Phys ; 31(7): 799-805, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19375374

RESUMO

Clinical and experimental studies indicate that structural and functional changes in the microvasculature can predate or accompany risk factors for cardiovascular disease at the earliest stages in the disease process. In the current work, both simulated and actual Doppler ultrasound maximum blood velocity waveform envelopes recorded from the ophthalmic artery were analysed using a root-MUSIC and least squares fitting approach to determine amplitude frequency spectra. Both amplitude and frequency components of noise contaminated simulated waveforms were reliably determined indicating the robustness of the technique. The technique was then used to compare the spectral content of the ophthalmic artery blood velocity waveforms of normal controls in three test states: at baseline, following administration of GTN, a nitric oxide donor, and following administration of L-Name, a nitric oxide inhibitor. Principal components derived from root-MUSIC analysis discriminated between waveforms in baseline and non-baseline test states (p<0.00001) and between GTN and non-GTN test states (p=0.0002).


Assuntos
Óxido Nítrico/metabolismo , Artéria Oftálmica/efeitos dos fármacos , Artéria Oftálmica/fisiologia , Processamento de Sinais Assistido por Computador , Adolescente , Adulto , Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Humanos , NG-Nitroarginina Metil Éster/farmacologia , Óxido Nítrico/agonistas , Óxido Nítrico/antagonistas & inibidores , Doadores de Óxido Nítrico/farmacologia , Artéria Oftálmica/diagnóstico por imagem , Ultrassom , Ultrassonografia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...