Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
J Am Coll Cardiol ; 82(16): 1598-1610, 2023 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-37821170

RESUMO

BACKGROUND: Flurpiridaz F-18 (flurpiridaz) is a novel positron emission tomography (PET) myocardial perfusion imaging tracer. OBJECTIVES: The purpose of this study was to further assess the diagnostic efficacy and safety of flurpiridaz for the detection and evaluation of coronary artery disease (CAD) defined as ≥50% stenosis by quantitative invasive coronary angiography (ICA). METHODS: In this second phase 3 prospective multicenter clinical study, 730 patients with suspected CAD from 48 clinical sites in the United States, Canada, and Europe were enrolled. Patients underwent 1-day rest/stress flurpiridaz PET and 1- or 2-day rest-stress Tc-99m-labeled single photon emission computed tomography (SPECT) before ICA. PET and SPECT images were read by 3 experts blinded to clinical and ICA data. RESULTS: A total of 578 patients (age 63.7 ± 9.5 years) were evaluable; 32.5% were women, 52.3% had body mass index ≥30 kg/m2, and 33.6% had diabetes. Flurpiridaz PET met the efficacy endpoints of the study; its sensitivity and specificity were significantly higher than the prespecified threshold value by 2 of the 3 readers. The sensitivity of flurpiridaz PET was higher than SPECT (80.3% vs 68.7%; P = 0.0003) and its specificity was noninferior to SPECT (63.8% vs 61.7%; P = 0.0004). PET area under the receiver-operating characteristic curves were higher than SPECT in the overall population (0.80 vs 0.68; P < 0.001), women, and obese patients (P < 0.001 for both). Flurpiridaz PET was superior to SPECT (P < 0.001) for perfusion defect size/severity evaluation, image quality, diagnostic certainty, and radiation exposure. Flurpiridaz PET was safe and well tolerated. CONCLUSIONS: This second flurpiridaz PET myocardial perfusion imaging trial shows that flurpiridaz has utility as a new tracer for CAD detection, specifically in women and obese patients. (An International Study to Evaluate Diagnostic Efficacy of Flurpiridaz [18F] Injection PET MPI in the Detection of Coronary Artery Disease [CAD]; NCT03354273).


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artérias , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Obesidade , Tomografia por Emissão de Pósitrons/métodos , Estudos Prospectivos , Compostos Radiofarmacêuticos/farmacologia , Tomografia Computadorizada de Emissão de Fóton Único/métodos
2.
J Nucl Cardiol ; 30(5): 2006-2017, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36598748

RESUMO

Dynamic acquisition allows absolute quantification of myocardial perfusion and flow reserve, offering an alternative to overcome the potential limits of relative quantification, especially in patients with balanced multivessel coronary artery disease. SPECT myocardial perfusion is widely available, at lower cost than PET. Dynamic cardiac SPECT is now feasible and has the potential to be the next step of comprehensive perfusion imaging. In order to help nuclear cardiologists potentially interested in using dynamic perfusion SPECT, we sought to review the different steps of acquisition, processing, and reporting of dynamic SPECT studies in order to enlighten the potentially critical pitfalls and artifacts. Both patient-related and technical artifacts are discussed. Key parameters of the acquisition include pharmacological stress, radiopharmaceuticals, and injection device. When it comes to image processing, attention must be paid to image-derived input function, patient motion, and extra-cardiac activity. This review also mentions compartment models, cameras, and attenuation correction. Finally, published data enlighten some facets of dynamic cardiac SPECT while several issues remain. Harmonizing acquisition and quality control procedures will likely improve its performance and clinical strength.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Humanos , Artefatos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Compostos Radiofarmacêuticos , Perfusão , Imagem de Perfusão do Miocárdio/métodos
3.
J Nucl Cardiol ; 30(4): 1399-1405, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36352084

RESUMO

BACKGROUND: Residual activity in dispensing syringes is a problem that has been sporadically reported with various radiopharmaceuticals. Studies with [99mTc]Tc-tetrofosmin are non-consistent so far. The aim was to quantify the residual activity of [99mTc]Tc-tetrofosmin in different syringes in a clinical setting and to assess its impact on the clinical imaging procedure. METHODS: The residual activity of [99mTc]Tc-tetrofosmin was measured in 3 types of syringes: 3-part lubricated and non-lubricated syringes and 2-part syringe (n ≥ 30 for each syringe). The residual activity was located and quantified using a CzT SPECT camera and radio-counting then was correlated with different clinical parameters and processed by multiple linear regression analysis. RESULTS: Residual activity was different in all syringe types but lubricated syringes showed significantly higher levels with a mean ± SD of 26.12 ± 10.21% (P < .001). For these syringes, the residual activity was mainly located on the lubricated body. They also have a positive and significant impact on the standardized counting duration of patients' acquisitions. CONCLUSION: Lubricated syringes with high residual activity should be avoided as they increase the risk of prolonging patient acquisition time and potentially increasing the risk of poor image quality.


Assuntos
Imagem de Perfusão do Miocárdio , Seringas , Humanos , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único , Compostos Organofosforados , Compostos de Organotecnécio
4.
J Nucl Cardiol ; 29(2): 506-514, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-32715418

RESUMO

BACKGROUND: The aim of this study was to investigate the feasibility of assessing absolute myocardial 99mTc-HMDP uptake in patients with suspected cardiac ATTR using SUV with a whole-body CZT SPECT-CT camera (DNM670CZT). METHODS: Fifteen patients with suspected cardiac ATTR (Perugini ≥ 2) underwent a conventional 99mTc-HMDP planar imaging and a thoracic SPECT/CT using a DNM 670CZT. A control group consisted of 15 patients with negative scintigraphy (Perugini < 2). SUVmax (mg·L-1) and percentage of injected dose (%ID) were calculated in a cardiac volume of interest (VOI) encompassing the left ventricle. VOIs were also placed in the lung, the right pectoris major, and the sternum. A heart-to-lung SUVmax ratio (HLR) was calculated. RESULTS: All ATTR patients demonstrated an increased cardiac HMDP SUVmax (12.2 ± 3.7 mg·L-1) vs controls (3.5 ± 1.2, P < .0001). Percentage of ID, pectoral uptake and HLR were significantly higher in the ATTR group (1.1 ± 0.3 vs 0.15 ± 0.8, P < .0001; 1.5 ± 0.3 vs 0.9 ± 0.3, P < .0001; 9.7 ± 3 vs 4.3 ± 2.2, P < .0001). Bone uptake was not statistically different between the two groups. CONCLUSION: This study demonstrated the feasibility of quantitative 99mTc-HMDP SUVmax measurement using a whole-body SPECT/CT CZT camera in patients with suspected cardiac ATTR.


Assuntos
Amiloidose , Pré-Albumina , Cádmio , Humanos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Telúrio , Zinco
5.
Eur J Nucl Med Mol Imaging ; 48(13): 4331-4338, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34169368

RESUMO

PURPOSE: The coronavirus disease 2019 (COVID-19) pandemic reshaped the usual risk: benefit equilibrium that became a trade-off between the infection exposure risk for the patient (and for staff) and the risk associated with delaying or cancelling the nuclear medicine examination. This study aimed at quantifying the impact of the first COVID-19 lockdown in France on nuclear medicine examination volume together with volume of examination cancellation and non-attendance. METHODS: We retrospectively assessed the volume of planned examinations from 1 month before to 1 month after the first lockdown in French high-volume nuclear medicine departments (NMD) sharing the same information management system including both university hospitals, UH (n = 7), and cancer centres, CC (n = 2). RESULTS: The study enrolled 31,628 consecutive patients referred for a nuclear medicine examination performed or not (NMEP or NMEnP). The total volume of NMEP significantly dropped by 43.4% between the 4 weeks before and after the starting of the lockdown. The comparison of the percentage of NMEP and NMEnP between UH and CC is significantly different (p < 0.001). The percentage of NMEP during the study was 67.9% in UH vs 84.7% in CC. Percentages of NMEnP in UH and CC were due respectively to cancellation by the patient (14.9 vs 7.4%), cancellation by the NMD (9.5 vs 3.4%), cancellation by the referring physician (5.1 vs 4.4%) and non-attender patients (2.7 vs 0.2%). CONCLUSION: The study underlines the public health issue caused by COVID-19 above the pandemic itself and should be useful in preparing for potential resource utilisation and staffing requirements.


Assuntos
COVID-19 , Medicina Nuclear , Controle de Doenças Transmissíveis , França/epidemiologia , Humanos , Estudos Retrospectivos , SARS-CoV-2
6.
J Nucl Cardiol ; 28(3): 1105-1116, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33521873

RESUMO

BACKGROUND: Positron emission tomography (PET) myocardial perfusion imaging (MPI) with the novel radiopharmaceutical Fluorine-18 Flurpiridaz has been shown in Phase 1, 2, and first Phase 3 clinical studies to be safe and effective in diagnosing coronary artery disease (CAD). We describe the methodology of the second FDA-mandated phase 3 prospective, open-label, international, multi-center trial of F-18 Flurpiridaz PET MPI. METHODS: The primary study end point is to assess the diagnostic efficacy of F-18 Flurpiridaz PET MPI in the detection of significant CAD [≥ 50% by quantitative invasive coronary angiography (ICA)] in patients with suspected CAD. The secondary endpoints are to evaluate the diagnostic efficacy of F-18 Flurpiridaz PET MPI compared to Tc-99 m-labeled SPECT MPI in the detection of CAD in all patients and in the following subgroups: (1) females; (2) patients with body mass index ≥ 30 kg/m2; and (3) diabetic patients. This trial's design differs from the first phase 3 trial in that (1) comparison to SPECT is now a secondary end point; (2) patients with known CAD are excluded; and (3) both SPECT and PET MPI are performed before ICA. CONCLUSIONS: This second phase 3 study will provide additional evidence on the diagnostic efficacy of F-18 Flurpiridaz PET MPI in the detection of significant CAD. TRIAL REGISTRATION NUMBER: NCT03354273.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons , Piridazinas , Ensaios Clínicos Fase III como Assunto , Humanos , Estudos Multicêntricos como Assunto , Projetos de Pesquisa
7.
Eur Heart J Cardiovasc Imaging ; 22(5): 480-490, 2021 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-33523108

RESUMO

Cardiac sympathetic activity plays a key role in supporting cardiac function in both health and disease conditions, and nuclear cardiac imaging has always represented the only way for the non-invasive evaluation of the functional integrity of cardiac sympathetic terminals, mainly through the use of radiopharmaceuticals that are analogues of norepinephrine and, in particular, with the use of 123I-mIBG imaging. This technique demonstrates the presence of cardiac sympathetic dysfunction in different cardiac pathologies, linking the severity of sympathetic nervous system impairment to adverse patient's prognosis. This article will outline the state-of-the-art of cardiac 123I-mIBG imaging and define the value and clinical applications in the different fields of cardiovascular diseases.


Assuntos
Medicina Nuclear , 3-Iodobenzilguanidina , Diagnóstico por Imagem , Coração , Humanos , Cintilografia , Compostos Radiofarmacêuticos , Sistema Nervoso Simpático/diagnóstico por imagem
8.
J Nucl Cardiol ; 28(4): 1477-1486, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31452085

RESUMO

BACKGROUND: We compared quantification of MBF and myocardial flow reserve (MFR) with a 99mTc-sestamibi CZT-SPECT to 15O-water PET. METHODS: SPECT MBF for thirty patients in the WATERDAY study was re-analyzed by QPET software with motion correction and optimal placement of the arterial input function. 15O-water PET MBF was re-quantified using dedicated software. Inter-operator variability was assessed using repeatability coefficients (RPC). RESULTS: Significant correlations were observed between global (r = 0.91, P < 0.001) and regional MBF (r = 0.86, P < 0.001) with SPECT compared to PET. Global MBF (rest 0.95 vs 1.05 ml/min/g, P = 0.07; stress 2.62 vs 2.68 mL/min/g, P = 0.17) and MFR (2.65 vs 2.75, P = 0.86) were similar between SPECT and PET. Rest (0.81 vs 0.98 mL/min/g, P = 0.03) and stress MBF (1.98 vs 2.61 mL/min/g, P = 0.01) in right coronary artery (RCA) were lower with SPECT compared to PET. However, MFR in the RCA territory was similar (2.54 vs 2.77, P = 0.21). The SPECT-PET RPC for global MBFs and MFR were 0.95 mL/min/g and 0.94, with inter-observer RPC of 0.59 mL/min/g and 0.74, respectively. CONCLUSIONS: MBF and MFR derived from CZT-SPECT with motion correction and optimal placement of the arterial input function showed good agreement with 15O-water PET, as well as low inter-operator variability.


Assuntos
Cádmio , Doença da Artéria Coronariana/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único , Zinco , Idoso , Algoritmos , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Variações Dependentes do Observador , Radioisótopos de Oxigênio , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Tecnécio Tc 99m Sestamibi , Água
9.
J Nucl Cardiol ; 28(4): 1490-1503, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31468379

RESUMO

BACKGROUND: To evaluate whether planar 123I-MIBG myocardial scintigraphy predicts risk of death in heart failure (HF) patients up to 5 years after imaging. METHODS AND RESULTS: Subjects from ADMIRE-HF were followed for approximately 5 years after imaging (964 subjects, median follow-up 62.7 months). Subjects were stratified according to the heart/mediastinum (H/M) ratio (< 1.60 vs ≥ 1.60) on planar 123I-MIBG scintigraphic images obtained at baseline in ADMIRE-HF. Cox proportional hazards models and Kaplan-Meier analyses were used to evaluate time to death, cardiac death, or arrhythmic events for subjects stratified by H/M ratio, baseline left ventricular ejection fraction (LVEF: < 25% and 25 to ≤ 35%), and by H/M strata within LVEF strata. All-cause mortality was 38.4% vs 20.9% and cardiac mortality was 16.8% vs 4.5%, in subjects with H/M < 1.60 vs ≥ 1.60, respectively (P < 0.05 for both comparisons). Subjects with preserved sympathetic innervation of the myocardium (H/M ≥ 1.60) were at significantly lower risk of all-cause and cardiac death, arrhythmic events, sudden cardiac death, or potentially life-threatening arrhythmias. Within LVEF strata, a trend toward a higher mortality for subjects with H/M < 1.60 was observed reaching significance for LVEF 25 to ≤ 35% only. CONCLUSIONS: During a median follow-up of 62.7 months, patients with H/M ≥ 1.60 were at significantly lower risk of death and arrhythmic events independently of LVEF values.


Assuntos
3-Iodobenzilguanidina , Insuficiência Cardíaca/diagnóstico por imagem , Coração/inervação , Radioisótopos do Iodo , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Volume Sistólico , Análise de Sobrevida , Sistema Nervoso Simpático/diagnóstico por imagem , Fatores de Tempo
10.
Eur J Nucl Med Mol Imaging ; 48(4): 1040-1069, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33135093

RESUMO

The use of cardiac PET, and in particular of quantitative myocardial perfusion PET, has been growing during the last years, because scanners are becoming widely available and because several studies have convincingly demonstrated the advantages of this imaging approach. Therefore, there is a need of determining the procedural modalities for performing high-quality studies and obtaining from this demanding technique the most in terms of both measurement reliability and clinical data. Although the field is rapidly evolving, with progresses in hardware and software, and the near perspective of new tracers, the EANM Cardiovascular Committee found it reasonable and useful to expose in an updated text the state of the art of quantitative myocardial perfusion PET, in order to establish an effective use of this modality and to help implementing it on a wider basis. Together with the many steps necessary for the correct execution of quantitative measurements, the importance of a multiparametric approach and of a comprehensive and clinically useful report have been stressed.


Assuntos
Sistema Cardiovascular , Imagem de Perfusão do Miocárdio , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Radioisótopos , Reprodutibilidade dos Testes
13.
EJNMMI Phys ; 7(1): 18, 2020 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-32185566

RESUMO

BACKGROUND: Evaluate the physical performance of the VERITON CzT camera (Spectrum Dynamics, Caesarea, Israel) that benefits from new detection architecture enabling whole-body imaging compared to that of a conventional dual-head Anger camera. METHODS: Different line sources and phantom measurements were performed on each system to evaluate spatial resolution, sensitivity, energy resolution and image quality with acquisition and reconstruction parameters similar to those used in clinical routine. Extrinsic resolution was assessed using 99mTc capillary sources placed successively in air, in a head and in a body phantom filled with background activity. Spectral acquisitions for various radioelements used in nuclear medicine (99mTc, 123I, 201Tl, 111In) were performed to evaluate energy resolution by computing the FWHM of the measured photoelectric peak. Tomographic sensitivity was calculated by recording the total number of counts detected during tomographic acquisition for a set of source geometries representative of different clinical situations. Sensitivity was also evaluated in focus mode for the CzT camera, which consisted of forcing detectors to collect data in a reduced field-of-view. Image quality was assessed with a Jaszczak phantom filled with 350 MBq of 99mTc and scanned on each system with 30-,20-,10- and 5-min acquisition times. RESULTS: Extrinsic and tomographic resolution in the brain and body phantoms at the centre of the FOV was estimated at 3.55, 7.72 and 6.66 mm for the CzT system and 2.47, 7.75 and 7.72 mm for the conventional system, respectively. The energy resolution measured at 140 keV was 5.46% versus 9.21% for the Anger camera and was higher in a same manner for all energy peaks tested. Tomographic sensitivity for a point source in air was estimated at 236 counts·s-1·MBq-1 and increased to 1159 counts·s-1·MBq-1 using focus mode, which was 1.6 times and 8 times greater than the sensitivity measured on the scintillation camera (144 counts·s-1·MBq-1). Head and body measurements also showed higher sensitivity for the CzT camera in particular with focus mode. The Jaszczak phantom showed high image contrast uniformity and a high signal-to-noise ratio on the CzT system, even when decreasing acquisition time by 6-fold. Representative clinical cases are shown to illustrate these results. CONCLUSION: The CzT camera has a superior sensitivity, higher energy resolution and better image contrast than the conventional SPECT camera, whereas spatial resolution remains similar. Introduction of this new technology may change current practices in nuclear medicine such as decreasing acquisition time and activity injected to patient.

14.
J Nucl Cardiol ; 27(6): 2247-2257, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-30515748

RESUMO

BACKGROUND: This study aimed to determine whether the repeatability of dyssynchrony assessment using gated myocardial perfusion SPECT (GSPECT) allows the detection of synchrony reserve during low-dose dobutamine infusion. METHODS AND RESULTS: Sixty-one patients with ischemic cardiomyopathy and LV ejection fraction < 50% were prospectively included in 10 centers. Each patient underwent two consecutive rest GSPECT with 99mTc-labeled tracer (either tetrofosmin or sestamibi) to assess the repeatability of LV function and dyssynchrony parameters, followed by a GSECT acquisition during low-dose dobutamine infusion. LV dyssynchrony was assessed using QGS software through histogram bandwidth (BW), standard deviation of the phase (SD), and entropy. Repeatability was assessed with Lin's concordance correlation coefficient (CCC). Entropy showed a higher CCC (0.80) compared to BW (0.68) and SD (0.75). On average, dobutamine infusion yielded to improve both BW (P = .049) and entropy (P = .04) although significant improvements, setting outside the 95% confidence interval of the repeatability analysis, were documented in only 6 and 4 patients for BW and entropy, respectively. CONCLUSIONS: A synchrony reserve may be documented in patients with ischemic cardiomyopathy through the recording of BW and entropy with low-dose dobutamine GSPECT, with the additional advantage of a higher repeatability for entropy.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Dobutamina/administração & dosagem , Isquemia Miocárdica/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Tecnécio/química , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Entropia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Compostos Radiofarmacêuticos/administração & dosagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Volume Sistólico , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda
15.
EJNMMI Res ; 9(1): 117, 2019 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-31873816

RESUMO

PURPOSE: We aimed to compare different methods for semi-quantitative analysis of cardiac retention of bone tracers in patients with cardiac transthyretin amyloidosis (ATTR). METHODS: Data from 67 patients with ATTR who underwent both conventional whole-body scan and a CZT myocardial SPECT (DSPECT, Spectrum Dynamics) 3 h after injection of 99mTc-labeled bone tracer were analyzed. Visual scoring of cardiac retention was performed on whole-body scan according to Perugini 4-point grading system from 0 (no uptake) to 3 (strong cardiac uptake with mild/absent bone uptake). A planar heart-to-background (H:B) ratio was calculated using whole-body scan (wb-H:B). CZT SPECT was quantified using three methods: planar H:B ratio calculated from anterior reprojection (ant-H:B), left anterior oblique reprojection (LAO-H:B), and 3D-H:B ratio calculated from transaxial slices as mean counts in a VOI encompassing the heart divided by background VOI in the contralateral lung. Interventricular septal thickness was obtained using echocardiography. RESULTS: H:Bs obtained from planar and reprojected data were not statistically different (wb-H:B, 2.05 ± 0.64, ant-H:B, 1.97 ± 0.61, LAO-H:B, 2.06 ± 0.64, all p = ns). However, 3D-H:B was increased compared to planar H:Bs (3D-H:B, 4.06 ± 1.77, all p < 0.0001 vs. wb-H:B, ant-H:B, and LAO-H:B). Bland-Altman plots demonstrated that the difference between 3D and planar H:Bs increased with the mean value of myocardial uptake. 3D-H:B was best correlated to septal thickness (r = 0.45, p < 0.001). Finally, abnormal right ventricular uptake was associated with higher values of cardiac retention. CONCLUSION: 3D semi-quantitative analysis of CZT SPECT optimized the assessment of 99mTc-labeled bone tracer myocardial uptake in patients with cardiac amyloidosis.

17.
Eur J Hybrid Imaging ; 3(1): 11, 2019 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-34191169

RESUMO

An increasing number of Nuclear Medicine sites in Europe are using cardiac-centered gamma cameras for myocardial perfusion scintigraphy (MPS). Three cardiac-centered gamma cameras are currently the most frequently used in Europe: the D-SPECT (Spectrum Dynamics), the Alcyone (Discovery NM 530c and Discovery NM/CT 570c; General Electric Medical Systems), and the IQ-SPECT (Siemens Healthcare). The increased myocardial count sensitivity of these three cardiac-centered systems has allowed for a decrease in the activities of radiopharmaceuticals injected to patients for myocardial perfusion imaging and, consequently, radiation exposure of patients. When setting up protocols for MPS, the overall objective should be to maintain high diagnostic accuracy of MPS, while injecting the lowest activities reasonably achievable to reduce the level of radiation exposure of patient and staff. These guidelines aim at providing recommendations for acquisition protocols and image interpretation using cardiac-centered cameras. As each imaging system has specific design and features for image acquisition and analysis, these guidelines have been separated into three sections for each gamma camera system. These recommendations have been written by the members of the Cardiovascular Committee of EANM and were based on their own experience with each of these systems and on the existing literature.

18.
J Clin Imaging Sci ; 8: 51, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30546935

RESUMO

OBJECTIVE: We evaluated the relative performances of dipyridamole (Dip) and regadenoson (Reg) in a cohort of patients referred for coronary artery disease diagnosis or follow-up using myocardial perfusion imaging. MATERIALS AND METHODS: We retrospectively included 515 consecutive patients referred for 99mTc-sestamibi myocardial perfusion single-photon emission computerized tomography (SPECT) on a cadmium-zinc-telluride (CZT) camera after pharmacologic stress. About three quarters (n = 391, 76%) received Dip. Reg was administrated to patients with chronical respiratory disease or with body mass index (BMI) over 38 kg/m2 (n = 124, 24%). Patients with an abnormal stress scan (92%) underwent a rest imaging on the same day. Qualitative interpretation of perfusion images was achieved using QPS software, and the ischemic area was assessed using the 17-segment model. In patients undergoing a stress-rest protocol, perfusion polar plots were postprocessed using automated in-house software to quantify the extension, intensity, and location of the reversible perfusion defect. Statistical comparison between groups was performed using univariate and multivariate analysis. RESULTS: Qualitative analysis concluded to myocardial ischemia in 70% of the patients (69% in the Dip group, 76% in the Reg group, P = ns). In those patients, the number of involved segments (Dip 2.5 ± 1.6, Reg 2.7 ± 1.6, P = ns) and the proportion of patients with an ischemic area larger than two segments (Dip 30%, Reg 37%, P = ns) were comparable. Automated quantification of the reversible perfusion defect demonstrated similar defect extension, intensity, and severity in the two groups. Defect location was identical at the myocardial segment and vascular territory scales. CONCLUSIONS: Reg and Dip showed equal performances for ischemic burden characterization using myocardial CZT SPECT.

19.
EJNMMI Res ; 8(1): 92, 2018 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-30225682

RESUMO

BACKGROUND: We investigated the feasibility of left ventricular (LV) and right ventricular (RV) volume and function estimation using a first-pass gated 15O-water PET. This prospective study included 19 patients addressed for myocardial perfusion reserve assessment using 15O-water PET. PET data were acquired at rest and after regadenoson stress, and gated first-pass images were reconstructed over the time range corresponding to tracer first-pass through the cardiac cavities and post-processed using TomPool software; LV and RV were segmented using a semi-automated 4D immersion algorithm. LV volumes were computed using a count-based model and a fixed threshold at 30% of the maximal activity. RV volumes were computed using a geometrical model and an adjustable threshold that was set so as to fit LV and RV stroke volumes. Ejection curves were fitted using a deformable reference curve model. LV results were compared to those obtained using 99mTc-sestamibi gated myocardial SPECT in terms of end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF). RESULTS: There was an excellent concordance between rest and stress PET in terms of EDV and ESV (Lin's coefficient ~ 0.85-0.90), SV (~ 0.80), and EF (~ 0.75) for both ventricles. Correlation with myocardial SPECT was high for LV EDV (Pearson's R = 0.89, p < 0.001) and ESV (R = 0.87, p < 0.001) and satisfying for LV SV (R = 0.67, p < 0.001) and EF (R = 0.67, p < 0.001). Minimal LV ESV overestimation (+ 4 mL, p = 0.03) and EF underestimation (- 4%, p = 0.01) were observed using PET. CONCLUSIONS: Biventricular volume and function assessment are achievable using the first-pass PET, and LV parameters correlate well with those derived from gated myocardial SPECT.

20.
Ann Nucl Med ; 32(5): 319-327, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29560563

RESUMO

OBJECTIVE: The identification of cardiac sarcoidosis is challenging as there is no gold standard consensually admitted for its diagnosis. The aim of this study was to evaluate the diagnostic value of the assessment of cardiac dynamic 18F-fluoro-2-deoxyglucose positron emission tomography (18F-FDG PET/CT) and net influx constant (Ki) in patients suspected of cardiac sarcoidosis. METHODS: Data obtained from 30 biopsy-proven sarcoidosis patients suspected of cardiac sarcoidosis who underwent a 50-min list-mode cardiac dynamic 18F-FDG PET/CT after a 24 h high-fat and low-carbohydrate diet were analyzed. A normalized coefficient of variation of quantitative glucose influx constant, calculated as the ratio: standard deviation of the segmental Ki (min-1)/global Ki (min-1) was determined using a validated software (Carimas® 2.4, Turku PET Centre). Cardiac sarcoidosis was diagnosed according to the Japanese Ministry of Health and Welfare criteria. Receiving operating curve analysis was performed to determine sensitivity and specificity of cardiac dynamic 18F-FDG PET/CT analysis to diagnose cardiac sarcoidosis. RESULTS: Six out of 30 patients (20%) were diagnosed as having cardiac sarcoidosis. Myocardial glucose metabolism was significantly heterogeneous in patients with cardiac sarcoidosis who showed significantly higher normalized coefficient of variation values compared to patients without cardiac sarcoidosis (0.513 ± 0.175 vs. 0.205 ± 0.081; p = 0.0007). Using ROC curve analysis, we found a cut-off value of 0.38 for the diagnosis of cardiac sarcoidosis with a sensitivity of 100% and a specificity of 91%. CONCLUSIONS: Our results suggest that quantitative analysis of cardiac dynamic 18F-FDG PET/CT could be a useful tool for the diagnosis of cardiac sarcoidosis.


Assuntos
Fluordesoxiglucose F18 , Cardiopatias/diagnóstico por imagem , Coração/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos , Sarcoidose/diagnóstico por imagem , Adulto , Idoso , Dieta com Restrição de Carboidratos , Dieta Hiperlipídica , Ecocardiografia , Feminino , Glucose/metabolismo , Cardiopatias/metabolismo , Cardiopatias/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio , Miocárdio/metabolismo , Miocárdio/patologia , Curva ROC , Estudos Retrospectivos , Sarcoidose/metabolismo , Sarcoidose/patologia , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...