Arq. bras. oftalmol ; 86(6): e2021, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1520198

RESUMO

ABSTRACT Purpose: Since particles are released in syringes during intravitreal injections, we assessed them quantitatively after agitating syringes commonly used for intravitreal injections. Methods: With and without agitation, the SR 1-ml insulin, Becton-Dickinson Ultra-Fine 0.3-ml Short Needle with a half-unit scale, HSW Norm-Ject Tuberculin, and Becton-Di­ckinson 1-ml Luer Lok Tip were examined with buffer and bevacizumab, aflibercept, and ziv-aflibercept. Flow imaging microscopy was performed to assess the particle numbers, concentrations, morphology, and size distribution. Results: Using the Becton-Dickinson Ultra-Fine syringe, the average particle count after agitation was higher than in the no-agitation group. For particles greater than 10 and 25 µm, differences were observed using the SR syringe between the two studied conditions. There were no significant differences in the means for the other syringes. Without agitation, the SR syringe had the highest number of particles (2,417,361.7 ± 3,421,575.5) followed by the Becton-Dickinson Ultra-Fine with 812.530,9 ± 996.187,2. The Becton-Dickinson Luer Lok Tip and HSW Norm-Ject performed equally with 398,396.8 ± 484,239.2 and 416,016.4 ± 242,650.1 particles, respectively. Conclusions: Flicking syringes to eliminate air bubbles results in increased numbers of particles released during intravitreal injections into the human vitreous.


RESUMO Objetivo: Visto que partículas são liberadas nas seringas durante as injeções intravítreas (IVIs), estas foram avaliadas quantitativamente após a agitação das seringas mais comumente usadas para injeções intravítreas. Métodos: A seringa SR de 1 ml de insulina, a agulha curta Becton-Dickinson Ultra-Fine 0,3 ml com escala de meia unidade, HSW Norm-Ject Tuberculin e a Becton-Dickinson Luer Lok Tip de 1 ml foram estudadas com placedo e com bevacizumabe, aflibercept e ziv-aflibercept, com e sem agitação. MicroFlow Imaging Mi­croscopy foi realizada para avaliar o número de partículas, con­centração, morfologia e distribuição das mesmas por tamanho. Resultados: A contagem média de partículas após agitação foi maior do que no grupo sem agitação usando a seringa Becton-Di­ckinson Ultra-Fine. Diferenças foram observadas usando a seringa SR entre as duas condições estudadas para partículas maiores que 10 e 25 µm. Para as demais seringas, não foram observadas diferenças significativas nas médias. A seringa SR apresentou o maior número de partículas sem agitação (2.417.361,7 ± 3.421.575,5) seguida da Becton-Dickinson Ultra-Fine com 812.530,9 ± 996.187,2. A BD Luer Lok Tip e a HSW Norm-Ject se comportaram de forma semelhante com 398.396,8 ± 484.239,2 e 416.016,4 ± 242.650,1 partículas, respectivamente. Conclusões: Agitar seringas para remover bolhas de ar resulta em um maior número de partículas liberadas durante Becton-Dickinson no vítreo humano.

3.
Arq Bras Oftalmol ; 2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35857984

RESUMO

PURPOSE: Since particles are released in syringes during intravitreal injections, we assessed them quantitatively after agitating syringes commonly used for intravitreal injections. METHODS: With and without agitation, the SR 1-ml insulin, Becton-Dickinson Ultra-Fine 0.3-ml Short Needle with a half-unit scale, HSW Norm-Ject Tuberculin, and Becton-Di-ckinson 1-ml Luer Lok Tip were examined with buffer and bevacizumab, aflibercept, and ziv-aflibercept. Flow imaging microscopy was performed to assess the particle numbers, concentrations, morphology, and size distribution. RESULTS: Using the Becton-Dickinson Ultra-Fine syringe, the average particle count after agitation was higher than in the no-agitation group. For particles greater than 10 and 25 µm, differences were observed using the SR syringe between the two studied conditions. There were no significant differences in the means for the other syringes. Without agitation, the SR syringe had the highest number of particles (2,417,361.7 ± 3,421,575.5) followed by the Becton-Dickinson Ultra-Fine with 812.530,9 ± 996.187,2. The Becton-Dickinson Luer Lok Tip and HSW Norm-Ject performed equally with 398,396.8 ± 484,239.2 and 416,016.4 ± 242,650.1 particles, respectively. CONCLUSIONS: Flicking syringes to eliminate air bubbles results in increased numbers of particles released during intravitreal injections into the human vitreous.

4.
Eur J Ophthalmol ; : 11206721211019580, 2021 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-34024140

RESUMO

PURPOSE: To assess the variability of silicone oil (SO) particles released across syringes from the same lot and the role of different needle gauges. MATERIALS AND METHODS: Four syringe models and six needle models were assessed for SO release. About 50 microliters of a buffer solution were loaded into the syringe, needle or syringe/needle setup. The data were analyzed by imaging flow cytometry with fluorescently labeling for SO. RESULTS: All syringe models had a high coefficient of variation in SO release across syringes from the same lot. The amount of SO was significantly greater in the syringe when the needle was attached. SO particles with the BD 30G needle attached to the syringe were statistically greater than the 27G counterpart (p = 0.005). None of the other comparisons was statistically different. Finally, the number of SO particles was higher in the syringe/needle setup than in needles only (p = 0.0024). CONCLUSION: We found a high variability in SO content across syringes from the same lot. Additionally, there was no clear association between needle gauge and the number of SO particles, as well as their coefficient of variation. Finally, the needles accounted for a small number of SO particles in comparison to the combined syringe-needle setup.