J Otolaryngol Head Neck Surg ; 48(1): 57, 2019 11 05.
Artigo em Inglês | MEDLINE | ID: mdl-31690345

RESUMO

The aim of this letter is to respond to a commentary on a published article on the middle fossa approach to BONEBRIDGE implantation with self-drilling screws published by the senior authors.


Assuntos
Condução Óssea , Parafusos Ósseos , Resultado do Tratamento
2.
J Otolaryngol Head Neck Surg ; 48(1): 35, 2019 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-31358057

RESUMO

BACKGROUND: Bone conduction implants can be used in the treatment of conductive or mixed hearing loss. The BONEBRIDGE bone conduction implant (BB-BCI) is an active, transcutaneous device. BB-BCI implantation can be performed through either the transmastoid or retrosigmoid approach with their respective limitations. Here, we present a third, novel approach for BB-BCI implantation. OBJECTIVE: Describe the detailed surgical technique of BB-BCI implantation through a middle fossa approach with self-drilling screws and present preliminary audiometric outcome data following this approach. METHODS: A single institution, retrospective chart review was completed for patients implanted with the BB-BCI via the middle fossa approach. Preoperative planning and modelling were performed using 3D Slicer. Audiological testing was performed pre- and post-operatively following standard audiometric techniques. RESULTS: Forty patients underwent BB-BCI implantation using the middle fossa approach. Modelling techniques allowed for implantation through the use of external landmarks, obviating the need for intraoperative image guidance. The surgical technique was refined over time through experience and adaptation. Mean follow-up was 29 months (range 3-71 months) with no surgical complications, favourable cosmesis, and expected audiometric outcomes. An average functional gain of 39.6 dB (± 14.7 SD) was found. CONCLUSION: The middle fossa technique with self-drilling screws is a safe and effective option for BONEBRIDGE implantation. As a reference for other groups considering this approach, an annotated video has been included as a supplement to the study.


Assuntos
Parafusos Ósseos , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Implantação de Prótese/métodos , Audiometria de Tons Puros , Humanos , Desenho de Prótese , Estudos Retrospectivos , Cirurgia Assistida por Computador