Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-37363854

RESUMO

Singular value decomposition (SVD) has become a standard for clutter filtering of ultrafast ultrasound datasets. Its implementation requires the choice of appropriate thresholds to discriminate the singular value subspaces associated with tissue, blood, and noise signals. Comparing the similarity of the spatial singular vectors was shown to be a robust and efficient method to estimate the SVD thresholds. The correlation of the spatial singular vector envelopes gives the spatial similarity matrix (SSM), which usually exhibits two square-like domains juxtaposed along the diagonal of the SSM, representing the tissue and the blood subspaces. Up to now, the proposed methods to automatically segment these two subspaces on the SSM were of high computational complexity and had a long processing time. Here, we propose an optimized algorithm using a sum-table approach that decreases the complexity by two orders of magnitude: O(n4) to O(n2) . The proposed method resulted in processing times lower than 0.08 s for datasets of 2000 frames, whereas previous algorithms took more than 26 h, so an improvement by a factor of 106. We illustrated this adaptive square-fitting on the SSM in the in vivo case of human neonate brain imaging and carotid imaging with various conditions of clutter. This optimization of SVD thresholding is essential to develop the use of adaptive clutter filtering, especially for real-time applications or block-wise processing.


Assuntos
Algoritmos , Encéfalo , Recém-Nascido , Humanos , Velocidade do Fluxo Sanguíneo , Ultrassonografia , Imagens de Fantasmas , Encéfalo/diagnóstico por imagem
2.
IEEE Trans Med Imaging ; 42(8): 2223-2234, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37027649

RESUMO

Longitudinal assessment of brain perfusion is a critical parameter for neurodevelopmental outcome of neonates undergoing cardiopulmonary bypass procedure. In this study, we aim to measure the variations of cerebral blood volume (CBV) in human neonates during cardiac surgery, using Ultrafast Power Doppler and freehand scanning. To be clinically relevant, this method must satisfy three criteria: being able to image a wide field of view in the brain, show significant longitudinal CBV variations, and present reproducible results. To address the first point, we performed for the first time transfontanellar Ultrafast Power Doppler using a hand-held phased-array transducer with diverging waves. This increased the field of view more than threefold compared to previous studies using linear transducers and plane waves. We were able to image vessels in the cortical areas as well as the deep grey matter and temporal lobes. Second, we measured the longitudinal variations of CBV on human neonates undergoing cardiopulmonary bypass. When compared to a pre-operative baseline acquisition, the CBV exhibited significant variation during bypass: on average, + 20±3 % in the mid-sagittal full sector ( [Formula: see text]), - 11±3 % in the cortical regions ( [Formula: see text]) and - 10±4 % in the basal ganglia ( [Formula: see text]). Third, a trained operator performing identical scans was able to reproduce CBV estimates with a variability of 4% to 7.5% depending on the regions considered. We also investigated whether vessel segmentation could further improve reproducibility, but found that it actually introduced greater variability in the results. Overall, this study demonstrates the clinical translation of ultrafast power Doppler with diverging-waves and freehand scanning.


Assuntos
Volume Sanguíneo Cerebral , Ultrassonografia Doppler , Recém-Nascido , Humanos , Reprodutibilidade dos Testes , Ultrassonografia Doppler/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Circulação Cerebrovascular
3.
J Physiol ; 601(6): 1077-1093, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36779673

RESUMO

Newborns with congenital heart disease undergoing cardiac surgery are at risk of neurodevelopmental impairment with limited understanding of the impact of intra-operative cardiopulmonary bypass (CPB), deep hypothermia and selective cerebral perfusion on the brain. We hypothesized that a novel ultrasound technique, ultrafast power Doppler (UPD), can assess variations of cerebral blood volume (CBV) in neonates undergoing cardiac surgery requiring CPB. UPD was performed before, during and after surgery in newborns with hypoplastic left heart syndrome undergoing a Norwood operation. We found that global CBV was not significantly different between patients and controls (P = 0.98) and between pre- and post-surgery (P = 0.62). UPD was able to monitor changes in CBV throughout surgery, revealing regional differences in CBV during hypothermia during which CBV correlated with CPB flow rate (R2  = 0.52, P = 0.021). Brain injury on post-operative magnetic resonance imaging was observed in patients with higher maximum variation in CBV. Our findings suggest that UPD can quantify global and regional brain perfusion variation during neonatal cardiac surgery with this first intra-operative application demonstrating an association between CBV and CPB flow rate, suggesting loss of autoregulation. Therefore, the measurement of CBV by UPD could enable optimization of cerebral perfusion during cardiac surgery in neonates. KEY POINTS: The impact of cardiopulmonary bypass (CPB) on the neonatal brain undergoing cardiac surgery is poorly understood. Ultrafast power Doppler (UPD) quantifies cerebral blood volume (CBV), a surrogate of brain perfusion. CBV varies throughout CPB surgery and is associated with variation of the bypass pump flow rate during deep hypothermia. Association between CBV and bypass pump flow rate suggests loss of cerebrovascular autoregulatory processes. Quantitative monitoring of cerebral perfusion by UPD could provide a direct parameter to optimize CPB flow rate.


Assuntos
Hipotermia Induzida , Hipotermia , Humanos , Recém-Nascido , Ponte Cardiopulmonar/métodos , Hipotermia Induzida/métodos , Homeostase , Ultrassonografia , Circulação Cerebrovascular/fisiologia
4.
J Cardiovasc Magn Reson ; 25(1): 2, 2023 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-36683053

RESUMO

BACKGROUND: This study compares three-dimensional (3D) high-resolution (HR) late gadolinium enhancement (LGE; 3D HR-LGE) imaging using a respiratory navigated, electrocardiographically-gated inversion recovery gradient echo sequence with conventional LGE imaging using a single-shot phase-sensitive inversion recovery (PSIR) balanced steady-state free precession (bSSFP; PSIR-bSSFP) sequence for routine clinical use in the pediatric population. METHODS: Pediatric patients (0-18 years) who underwent clinical cardiovascular magnetic resonance (CMR) with both 3D HR-LGE and single-shot PSIR-bSSFP LGE between January 2018 and June 2020 were included. Image quality (0-4) and detection of LGE in the left ventricle (LV) (per 17 segments), in the right ventricle (RV) (per 3 segments), as endocardial fibroelastosis (EFE), at the hinge points, and at the papillary muscles was analyzed by two blinded readers for each sequence. Ratios of the mean signal intensity of LGE to normal myocardium (LGE:Myo) and to LV blood pool (LGE:Blood) were recorded. Data is presented as median (1st-3rd quartiles). Wilcoxon signed rank test and chi-square analyses were used as appropriate. Inter-rater agreement was analyzed using weighted κ-statistics. RESULTS: 102 patients were included with median age at CMR of 8 (1-13) years-old and 44% of exams performed under general anesthesia. LGE was detected in 55% of cases. 3D HR LGE compared to single-shot PSIR-bSSFP had longer scan time [4:30 (3:35-5:34) vs 1:11 (0:47-1:32) minutes, p < 0.001], higher image quality ratings [3 (3-4) vs 2 (2-3), p < 0.001], higher LGE:Myo [23.7 (16.9-31.2) vs 5.0 (2.9-9.0), p < 0.001], detected more segments of LGE in both the LV [4 (2-8) vs 3 (1-7), p = 0.045] and RV [1 (1-1) vs 1 (0-1), p < 0.001], and also detected more cases of LGE with 13/56 (23%) of patients with LGE only detectable by 3D HR LGE (p < 0.001). 3D HR LGE specifically detected a greater proportion of RV LGE (27/27 vs 17/27, p < 0.001), EFE (11/11 vs 5/11, p = 0.004), and papillary muscle LGE (14/15 vs 4/15, p < 0.001). Inter-rater agreement for the recorded variables ranged from 0.42 to 1.00. CONCLUSIONS: 3D HR LGE achieves greater image quality and detects more LGE than conventional single-shot PSIR-bSSFP LGE imaging, and should be considered an alternative to conventional LGE sequences for routine clinical use in the pediatric population.


Assuntos
Meios de Contraste , Cardiopatias Congênitas , Humanos , Criança , Lactente , Pré-Escolar , Adolescente , Gadolínio , Estudos de Viabilidade , Valor Preditivo dos Testes , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/patologia , Miocárdio/patologia , Imageamento por Ressonância Magnética/métodos
5.
Eur Heart J Cardiovasc Imaging ; 24(2): 241-249, 2023 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-36327421

RESUMO

AIMS: To quantify thoracic lymphatic burden in paediatric Fontan patients using MRI and correlate with clinical status. METHODS AND RESULTS: Paediatric Fontan patients (<18-years-old) with clinical cardiac MRI that had routine lymphatic 3D T2 fast spin echo (FSE) imaging performed from May 2017 to October 2019 were included. 'Lymphatic burden' was quantified by thresholding-based segmentation of the 3D T2 FSE maximum intensity projection image and indexed to body surface area, performed by two independent readers blinded to patient status. There were 48 patients (27 males) with median age at MRI of 12.9 (9.4-14.7) years, time from Fontan surgery to MRI of 9.1 (5.9-10.4) years, and follow-up time post-Fontan surgery of 9.4 (6.6-11.0) years. Intraclass correlation coefficient between two observers for lymphatic burden was 0.96 (0.94-0.98). Greater lymphatic burden correlated with post-Fontan operation hospital length of stay and duration of chest tube drainage (rs = 0.416, P = 0.004 and rs = 0.439, P = 0.002). Median lymphatic burden was greater in patients with chylous effusions immediately post-Fontan (178 (118-393) vs. 113 (46-190) mL/m2, P = 0.028), and in patients with composite adverse Fontan status (n = 13) defined by heart failure (n = 3), transplant assessment (n = 2), recurrent effusions (n = 6), Fontan thrombus (n = 2), and/or PLE (n = 6) post-Fontan (435 (137-822) vs. 114 (51-178) mL/m2, P = 0.003). Lymphatic burden > 600 mL/m2 was associated with late adverse Fontan status with sensitivity of 57% and specificity of 95%. CONCLUSION: Quantification of MR lymphatic burden is a reliable tool to assess the lymphatics post-Fontan and is associated with clinical status.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Masculino , Humanos , Criança , Adolescente , Linfografia/métodos , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia
6.
J Am Heart Assoc ; 11(5): e024220, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35179047

RESUMO

Pediatric hypertrophic cardiomyopathy (HCM) is the most common form of cardiomyopathy in children and a leading cause of sudden cardiac death. Yet, the association between genotype variation, phenotype expression, and adverse events in pediatric HCM has not been fully elucidated. Although the literature on this topic is evolving in adult HCM, the evidence in children is lacking. Solidifying our understanding of this relationship could improve risk stratification as well as improve our comprehension of the underlying pathophysiological characteristics of pediatric HCM. In this state-of-the-art review, we examine the current literature on genetic variations in HCM and their association with outcomes in children, discuss the current approaches to identifying cardiovascular phenotypes in pediatric HCM, and explore possible avenues that could improve sudden cardiac death risk assessment.


Assuntos
Cardiomiopatia Hipertrófica , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/genética , Cardiomiopatia Hipertrófica/metabolismo , Criança , Morte Súbita Cardíaca/etiologia , Estudos de Associação Genética , Genótipo , Humanos , Fenótipo
7.
Pediatr Radiol ; 52(5): 951-958, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35076727

RESUMO

BACKGROUND: Children with orofacial deformity may require repeated imaging of the facial skeleton. OBJECTIVE: To test the feasibility and accuracy of "black bone" magnetic resonance imaging (MRI) for assessing facial deformity in children. MATERIALS AND METHODS: Three-dimensional (3-D) black bone gradient echo sequences (flip angle 5°, submillimetre spatial resolution) from 10 children (median age: 13 years, range: 2-16 years), who underwent MRI of the temporomandibular joints, were evaluated with multiplanar reconstruction and 3-D rendering tools. Intra- and inter-reader agreement was investigated for measuring the height of the mandibular ramus and condyle, basal length of the mandible, gonion angle and mandibular inclination angle by intraclass correlation coefficient (ICC) and Bland-Altman analysis. Absolute percentage error was calculated with the average of all measurements serving as reference. RESULTS: Sixty linear and 40 angle measurements were obtained on reformatted multiplanar black bone images with excellent inter-reader agreement (ICC > 0.99, agreement bias < 1.4 mm/ < 1.5°) and small error (median absolute error < 3%). The black bone images required inversion of the signal intensity and removal of air before they could be processed with standard volume rendering tools. The diagnostic utility of 3-D views for assessing the facial skeleton was sufficient except for assessing dental relationship. CONCLUSION: Morphometric measurements of the mandible can be obtained from black bone MRI with comparable inter-rater agreement to that reported for cone beam computed tomography (CT). With improvements of 3-D rendering techniques and software, black bone MRI may become a radiation-free alternative to CT in children with facial deformities.


Assuntos
Mandíbula , Crânio , Adolescente , Criança , Tomografia Computadorizada de Feixe Cônico/métodos , Cabeça , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Mandíbula/diagnóstico por imagem
8.
Pediatr Radiol ; 52(2): 262-270, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33978803

RESUMO

This review introduces the basic principles of contrast-enhanced magnetic resonance (MR) angiography and details four contrast-enhanced MR angiography sequences for body imaging with extracellular gadolinium-based contrast agents in pediatric patients. Specifically, this review covers (1) respiratory-navigated, cardiac-gated MR angiography; (2) time-resolved MR angiography; (3) conventional MR angiography; and (4) modified spoiled gradient echo variants. We present and discuss indications, technical considerations, sequence optimization, advantages and disadvantages, along with practical tips and illustrative case examples for each sequence.


Assuntos
Meios de Contraste , Angiografia por Ressonância Magnética , Criança , Humanos , Imageamento por Ressonância Magnética
9.
J Clin Med ; 10(18)2021 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-34575158

RESUMO

Contrast-enhanced magnetic resonance imaging (MRI) remains the most comprehensive modality to assess juvenile idiopathic arthritis (JIA)-related inflammation and osteochondral damage in the temporomandibular joints (TMJ). This study tested the reliability of a new JIA MRI scoring system for TMJ (JAMRIS-TMJ) and the impact of variations in calibration and reader specialty. Thirty-one MRI exams of bilateral TMJs were scored independently using the JAMRIS-TMJ by 20 readers consisting of radiologists and non-radiologist clinicians in three reading groups, with or without a calibrating atlas and/or tutorial. The inter-reader reliability in the multidisciplinary cohort assessed by the generalizability coefficient was 0.61-0.67 for the inflammatory and 0.66-0.74 for the damage domain. The atlas and tutorial did not improve agreement within radiologists, but improved the agreement between radiologist and non-radiologist groups. Agreements between different calibration levels were 0.02 to 0.08 lower by the generalizability coefficient compared to agreement within calibration levels; agreement between specialty groups was 0.04 to 0.10 lower than within specialty groups. Averaging two radiologists raised the reliability above 0.8 for both domains. Therefore, the reliability of JAMRIS-TMJ was moderate-to-good depending on the presence of specialty and calibration differences. The atlas and tutorial are necessary to improve reliability when the reader cohort consists of multiple specialties.

10.
Neuroimage Clin ; 31: 102756, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34298475

RESUMO

Abnormal variations of the neonatal brain perfusion can result in long-term neurodevelopmental consequences and cerebral perfusion imaging can play an important role in diagnostic and therapeutic decision-making. To identify at-risk situations, perfusion imaging of the neonatal brain must accurately evaluate both regional and global perfusion. To date, neonatal cerebral perfusion assessment remains challenging. The available modalities such as magnetic resonance imaging (MRI), ultrasound imaging, computed tomography (CT), near-infrared spectroscopy or nuclear imaging have multiple compromises and limitations. Several promising methods are being developed to achieve better diagnostic accuracy and higher robustness, in particular using advanced MRI and ultrasound techniques. The objective of this state-of-the-art review is to analyze the methodology and challenges of neonatal brain perfusion imaging, to describe the currently available modalities, and to outline future perspectives.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Humanos , Recém-Nascido , Perfusão , Imagem de Perfusão , Tomografia Computadorizada por Raios X
11.
Can J Cardiol ; 37(12): 2083-2086, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33878418

RESUMO

Fetal and neonatal hypertrophic cardiomyopathy is a complication of gestational diabetes and usually follows a benign course. In this report, we present a rare case of a newborn of a diabetic mother with severe ventricular hypertrophy who developed myocardial infarction confirmed by elevated cardiac enzymes, electrocardiographic changes, and subendocardial ischemia on cardiac magnetic resonance imaging. Follow-up revealed complete functional myocardial recovery with normalisation of ventricular systolic and diastolic functions on serial echocardiograms.


Assuntos
Diabetes Gestacional , Ecocardiografia Doppler/métodos , Eletrocardiografia , Imagem Cinética por Ressonância Magnética/métodos , Infarto do Miocárdio/etiologia , Feminino , Humanos , Recém-Nascido , Infarto do Miocárdio/diagnóstico , Gravidez , Sístole
12.
J Cardiovasc Magn Reson ; 23(1): 28, 2021 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-33731161

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) late gadolinium enhancement (LGE) requires identification of the normal myocardial nulling time using inversion time (TI)-scout imaging sequence. Although TI-scout images are not primarily used for myocardial assessment, they provide information regarding different signal recovery patterns of normal and abnormal myocardium facilitating identification of LGE in instances where standard LGE images alone are not diagnostic. We aimed to assess the diagnostic performance of TI-scout as compared to that of standard LGE images. METHODS: CMR studies with LGE imaging in 519 patients (345 males, 1-17 years) were reviewed to assess the diagnostic performance of LGE imaging in terms of the location of LGE and the pathologic entities. The diagnostic performance of the TI-scout and standard LGE imaging was classified into four categories: (1) equally diagnostic, (2) TI-scout superior to standard LGE, (3) standard LGE superior to TI-scout, and (4) complementary, by the consensus of the two observers. RESULTS: The study cohort consisted of 440 patients with negative LGE and 79 with evidence for LGE. For a negative diagnosis of LGE, TI-scout and standard LGE images were equally diagnostic in 75% of the cases and were complementary in 12%. For patients with LGE, TI-scout images were superior to standard LGE images in 52% of the cases and were complementary in 19%. The diagnostic performance of TI-scout images was superior to that of standard LGE images in all locations. TI-scout images were superior to standard LGE images in 11 of 12 (92%) cases with LGE involving the papillary muscles, in 7 /12 (58%) cases with subendocardial LGE, and in 4/7 (57%) cases with transmural LGE. TI-scout images were particularly useful assessing the presence and extent of LGE in hypertrophic cardiomyopathy (HCM). TI-scout was superior to standard LGE in 6/10 (60%) and was complementary in 3/10 (30%) of the positive cases with HCM. CONCLUSIONS: TI-scout images enhance the diagnostic performance of LGE imaging in children.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Meios de Contraste , Imageamento por Ressonância Magnética , Meglumina/análogos & derivados , Miocárdio/patologia , Compostos Organometálicos , Adolescente , Fatores Etários , Cardiomiopatias/patologia , Criança , Pré-Escolar , Feminino , Fibrose , Humanos , Lactente , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Retrospectivos
13.
Pediatr Radiol ; 50(13): 1881-1894, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33252756

RESUMO

Fetal cardiovascular MRI is showing promise as a clinical diagnostic tool in the setting of congenital heart disease when the cardiac anatomy is unresolved by US or when complementary quantitative data on blood flow, oxygen saturation and hematocrit are required to aid in management. Compared with postnatal cardiovascular MRI, prenatal cardiovascular MRI still has some technical limitations. However, ongoing technical advances continue to improve the robustness and usability of fetal cardiovascular MRI. In this review, we provide an overview of the state of the art of fetal cardiovascular MRI and summarize the current focus of clinical application for this versatile technique.


Assuntos
Cardiopatias Congênitas , Imageamento por Ressonância Magnética , Feminino , Coração Fetal/diagnóstico por imagem , Feto/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Hemodinâmica , Humanos , Gravidez , Diagnóstico Pré-Natal , Ultrassonografia Pré-Natal
14.
Skeletal Radiol ; 48(8): 1261-1268, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30725159

RESUMO

OBJECTIVE: To determine in a cadaveric study the lowest achievable radiation dose and optimal tube potential generating diagnostic image quality in multidetector computed tomography (MDCT) arthrography of the shoulder. MATERIALS AND METHODS: Six shoulders from three human cadavers were scanned using a 256-MDCT system after intra-articular injection of diluted iodinated contrast material. Using six decreasing radiation dose levels (CTDIvol: 20, 15, 10, 8, 6, and 4 mGy) and for each dose level, four decreasing tube potentials (140, 120, 100, and 80 kVp), image noise and contrast-to-noise ratio (CNR) were measured. Two independent and blinded observers assessed the overall diagnostic image quality, subjective amount of noise, and severity of artifacts according to a four-point scale. Influence of those MDCT data acquisition parameters on objective and subjective image quality was analyzed using the Kruskal-Wallis and Wilcoxon signed-rank tests, and pairwise comparisons were performed. RESULTS: Multidetector CT protocols with radiation doses of 15 mGy or higher, combined with tube potentials of 100 kVp or higher, were equivalent in CNR to the reference 20 mGy-140 kVp protocol (all p ≥ 0.054). Above a CTDIvol of 10 mGy and a tube potential of 120 kVp, all protocols generated diagnostic image quality and subjective noise equivalent to the 20 mGy-140 kVp protocol (all p ≥ 0.22). CONCLUSIONS: Diagnostic image quality in MDCT arthrography of the shoulder can be obtained with a radiation dose of 10 mGy at an optimal tube potential of 120 kVp, corresponding to a reduction of up to 50% compared with standard-dose protocols, and as high as 500% compared with reported protocols in the literature.


Assuntos
Artrografia , Tomografia Computadorizada Multidetectores , Doses de Radiação , Articulação do Ombro/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Cadáver , Meios de Contraste , Feminino , Humanos , Masculino , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...