Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
PLOS Digit Health ; 3(4): e0000471, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38557601

RESUMO

OBJECTIVE: This study aims to assess the acceptability of a novel technology, MAchine Learning Application (MALA), among the mothers of newborns who required resuscitation. SETTING: This study took place at Bharatpur Hospital, which is the second-largest public referral hospital with 13 000 deliveries per year in Nepal. DESIGN: This is a cross-sectional survey. DATA COLLECTION AND ANALYSIS: Data collection took place from January 21 to February 13, 2022. Self-administered questionnaires on acceptability (ranged 1-5 scale) were collected from participating mothers. The acceptability of the MALA system, which included video and audio recordings of the newborn resuscitation, was examined among mothers according to their age, parity, education level and technology use status using a stratified analysis. RESULTS: The median age of 21 mothers who completed the survey was 25 years (range 18-37). Among them, 11 mothers (52.4%) completed their bachelor's or master's level of education, 13 (61.9%) delivered first child, 14 (66.7%) owned a computer and 16 (76.2%) carried a smartphone. Overall acceptability was high that all participating mothers positively perceived the novel technology with video and audio recordings of the infant's care during resuscitation. There was no statistical difference in mothers' acceptability of MALA system, when stratified by mothers' age, parity, or technology usage (p>0.05). When the acceptability of the technology was stratified by mothers' education level (up to higher secondary level vs. bachelor's level or higher), mothers with Bachelor's degree or higher more strongly felt that they were comfortable with the infant's care being video recorded (p = 0.026) and someone using a tablet when observing the infant's care (p = 0.046). Compared with those without a computer (n = 7), mothers who had a computer at home (n = 14) more strongly agreed that they were comfortable with someone observing the resuscitation activity of their newborns (71.4% vs. 14.3%) (p = 0.024). CONCLUSION: The novel technology using video and audio recordings for newborn resuscitation was accepted by mothers in this study. Its application has the potential to improve resuscitation quality in low-and-middle income settings, given proper informed consent and data protection measures are in place.

2.
EClinicalMedicine ; 68: 102375, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38545091

RESUMO

Background: Mortality and severe morbidity remain high in extremely preterm infants. Human milk-based nutrient fortifiers may prevent serious complications and death. We aimed to investigate whether supplementation with human milk-based fortifier (HMBF), as compared to bovine milk-based fortifier (BMBF), reduced the incidence of the composite outcome of necrotising enterocolitis (NEC), sepsis, and mortality in extremely preterm infants exclusively fed human milk. Methods: In this multicentre, randomised controlled trial at 24 neonatal units in Sweden, extremely preterm infants born between gestational week 22 + 0 and 27 + 6 fed exclusively human breast milk (mother's own and/or donor milk), were randomly assigned (1:1) to receive targeted fortification with either HMBF or BMBF. Randomisation was conducted before the enteral feeds reached 100 mL/kg/day, and was stratified by enrolment site, gestational age, singleton/twin, and sex. The allocation was concealed before inclusion, but after randomisation the study was not blinded for the clinical staff. For the NEC diagnosis, the study group was masked to an independent radiologist, and the final assessment of NEC and culture-proven sepsis was done by a blinded consensus panel review. The primary outcome was the composite of NEC stage II-III, culture-proven sepsis, and mortality from inclusion to discharge, no longer than postmenstrual week 44 + 0, in the intention-to-treat population (ClinicalTrials.gov, NCT03797157). Findings: Between February 21st, 2019, and May 21st, 2021, 229 neonates were randomly assigned (115 HMBF, 114 BMBF). After exclusion of one infant due to parents' withdrawal of consent, 228 infants were included in the intention-to-treat analysis. Of the 115 infants assigned to HMBF, 41 (35.7%) fulfilled the criteria of either NEC, sepsis, or death, compared with 39 (34.5%) of 113 infants assigned to BMBF (OR 1.05, 95% CI 0.61-1.81, p = 0.86). Adverse events did not differ significantly between groups. Interpretation: Supplementation with HMBF, as compared with BMBF, did not reduce the incidence of the composite outcome of NEC, sepsis, or death. Our results do not support routine supplementation with HMBF as a nutritional strategy to prevent NEC, sepsis, or death in extremely preterm infants exclusively fed human milk. Funding: ALF grant, Prolacta Bioscience, Swedish Research Council, and Research Council for Southeast Sweden.

3.
Sci Rep ; 14(1): 4210, 2024 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-38378837

RESUMO

The objective of this study was to investigate how placental gene expression differs in two consecutive pregnancies in same sex siblings, and its possible association with the "maternal constraint" hypothesis. Material was gathered from the BASIC study (Biological, Affect, Stress, Imaging, and Cognition in Pregnancy and the Puerperium), a population based prospective study that was started in 2009 in Uppsala. Over 900 specimens of placenta biopsies were collected and out of these 10 women gave birth twice, to the same sex child, and were included in this study. The total RNA was isolated and prepared from frozen villous tissue from the placenta and further analyzed by use of Ion AmpliSeq Human Transcriptome Gene Expression kit. A total of 234 genes differed significantly between the first and second pregnancy placentas, when adjusting for delivery mode, maternal BMI and gestational age. Of special interest was the down-regulated group of genes in the second pregnancy. Exemplified by Pentraxin 3, SRY-Box Transcription Factor 9, and Serum Amyloid A1, which all were associated with biological processes involved in the immune system and inflammation. Further, protein-protein interaction analysis visualized them as hub genes interacting with several of the other differentially expressed genes. How these altered gene expressions affect maternal constraint during pregnancy needs further validation in lager study cohorts and also future validation in functional assays.


Assuntos
Placenta , Irmãos , Criança , Gravidez , Humanos , Feminino , Placenta/metabolismo , Estudos Prospectivos , Transcriptoma , Número de Gestações
4.
Sci Rep ; 14(1): 725, 2024 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-38184682

RESUMO

Improvement of prenatal identification of large-for-gestational-age (LGA) infants could lower the risk for adverse outcomes. Therefore, we sought to evaluate the association of a combination of maternal waist circumference (WC) and abdominal fat depths with infant birth size. A cohort study including 1240 women was performed between 2015 and 2018 at Uppsala University Hospital, Sweden. Maternal WC was measured at the first antenatal visit, and visceral (VF) and subcutaneous (SCF) fat depths by ultrasound at the second-trimester anomaly scan. Waist circumference, VF, and SCF were categorized as low or high (cut-offs WC ≥ 88 cm, VF ≥ 54 mm, SCF ≥ 21 mm). Outcomes were birth weight standard deviation score (BWSDS) and LGA (BWSDS > 90th and > 97th percentile). Secondary outcome was small-for-gestational-age (SGA, BWSDS < 10th and < 3rd percentile). Univariate analysis of variance and logistic regression analyses were performed adjusted for maternal weight, height, parity, smoking, country of birth, pregestational diabetes, and chronic hypertension. For both high and low WC, high VF was positively associated with BWSDS and LGA. There was no association with SGA. The results did not demonstrate any value of the combination of WC and fat depth measures in predicting infant birth size but suggested VF as a marker for large infants.


Assuntos
Adiposidade , Obesidade Materna , Gravidez , Lactente , Feminino , Humanos , Estudos de Coortes , Obesidade Abdominal , Gordura Abdominal , Peso ao Nascer
5.
Sci Rep ; 13(1): 20919, 2023 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-38017078

RESUMO

This study aimed to evaluate the association of maternal adiponectin with infant birth size in 1349 pregnant women at Uppsala University Hospital, Sweden. The mean age of the women was 31.0 years, and 40.9% were nulliparous. Maternal early mid-pregnancy adiponectin was measured in microgram/mL. Linear regression models were performed to evaluate the association between adiponectin and infant birth weight. Logistic regression models were used to evaluate adiponectin in relation to the odds of giving birth to an infant large-for-gestational-age (LGA, infant birth weight standard deviation score > 90th percentile). Adjustments were made for early pregnancy BMI and diabetes mellitus. Prior adjustments, adiponectin was inversely associated with infant birth weight (ß - 17.1, 95% confidence interval (CI) - 26.8 to - 7.4 g, P < 0.001), and one microgram/mL increase in adiponectin was associated with a 9% decrease in the odds of giving birth to an LGA infant (odds ratio 0.91, CI 0.85-0.97, P = 0.006). The associations did not withstand in the adjusted models. We found a significant interaction between adiponectin and infant sex on birth size. This interaction was driven by an inverse association between maternal adiponectin and birth size in female infants, whereas no such association was found in males.


Assuntos
Adiponectina , Diabetes Mellitus , Adulto , Feminino , Humanos , Lactente , Masculino , Gravidez , Peso ao Nascer , Paridade , Recém-Nascido Grande para a Idade Gestacional
6.
Sci Rep ; 13(1): 15830, 2023 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-37739982

RESUMO

The rate of labor induction has increased in recent years. The results of previously conducted studies examining associations between elective induction of labor (IOL) and neonatal outcomes have been contradictory. The aim of this study was to examine the intrinsic neonatal risks following IOL. We conducted a population-based cohort study, including all women with recorded low-risk singleton pregnancies at a gestational age between 37 + 0 and 41 + 6 weeks in Sweden from 1999 to 2017. Data were collected from the Swedish Medical Birth register. Two study groups were compared-the elective induction group with the spontaneous labor onset group. The results showed that the rate of elective IOL increased from 7.2% in 1999 to 16.4% in 2017. Elective IOL was associated with a higher OR for chorioamnionitis, bacterial sepsis, intracranial hemorrhage, assisted ventilation, hyperbilirubinemia, APGAR < 7 at 5 min, and neonatal seizures compared to deliveries with spontaneous labor onset. Regarding mortality outcomes, no significant differences were shown between the groups for either early term or full-term deliveries. We conclude that IOL is associated with neonatal complications, although causality could not be established in this observational study. It is important to be aware of the increased risk and perform IOL with caution.


Assuntos
Conscientização , Corioamnionite , Gravidez , Recém-Nascido , Humanos , Feminino , Lactente , Estudos de Coortes , Idade Gestacional , Trabalho de Parto Induzido/efeitos adversos
7.
Nutrients ; 15(10)2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-37242201

RESUMO

Moderately preterm infants (32-36 weeks of gestational age) have an increased risk of worse health and developmental outcomes compared to infants born at term. Optimal nutrition may alter this risk. The aim of this study was to investigate the neurological, growth, and health outcomes up to six years of age in children born moderately preterm who receive either exclusive or fortified breast milk and/or formula in the neonatal unit. In this longitudinal cohort study, data were collected for 142 children. Data were collected up to six years of age via several questionnaires containing questions about demographics, growth, child health status, health care visits, and the Five to Fifteen Questionnaire. Data on the intake of breast milk, human milk fortification, formula, and growth during hospitalization were collected from the children's medical records. No statistically significant differences in neurological outcomes, growth, or health at six years of age were found between the two groups (exclusive breast milk, n = 43 vs. fortified breast milk and/or formula, n = 99). There is a need for research in larger populations to further assess potential effects on health and developmental outcomes when comparing the use of exclusive versus fortified breast milk for moderately preterm infants during neonatal hospitalization.


Assuntos
Recém-Nascido Prematuro , Leite Humano , Lactente , Feminino , Criança , Recém-Nascido , Humanos , Estudos Longitudinais , Fórmulas Infantis , Estudos de Coortes , Avaliação de Resultados em Cuidados de Saúde , Alimentos Fortificados
8.
J Perinatol ; 43(10): 1301-1307, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37185366

RESUMO

OBJECTIVE: Infants with severe bronchopulmonary dysplasia (sBPD) have complex medical courses. We developed the clinician-rated Optimal State Scoring Tool (OSST) that measures factors relevant to clinical improvement of sBPD and investigated preliminary validity using linear growth outcome and OSST scores in sBPD patients. METHODS: Tool development process and pilot findings are provided for 13 patients evaluated longitudinally. OSST scores, length measurements, and steroid dependency values were obtained. Changes in OSST scores and lengths were examined using linear mixed-effect models. RESULTS: OSST scores were significantly correlated with linear growth (95% CI 0.36, 0.57). The steroid-dependent group showed significantly slower rate of linear growth (95% CI 0.74, 1.05) and slower rate of increase in OSST scores (95% CI 0.99, 2.13) compared to the non-steroid-dependent group, with the OSST showing the largest effect size. CONCLUSION: Pilot data reflect promising evidence for OSST construct validity in monitoring clinical outcomes in sBPD patients.


Assuntos
Displasia Broncopulmonar , Recém-Nascido , Humanos , Lactente , Displasia Broncopulmonar/diagnóstico , Displasia Broncopulmonar/terapia
9.
Reprod Sci ; 30(4): 1165-1175, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36180668

RESUMO

The objective of this study was to evaluate the associations of 92 maternal blood-based proteins with increased infant birth size. The study was performed at the Uppsala University Hospital, Sweden, and included 857 mother and child dyads. The mean age of the women was 30.3 years, and 53.2% were nulliparous. Blood samples were collected at mean 18 + 2 weeks' gestation, and the Olink cardiovascular II panel was used to measure 92 proteins, either known to be or suspected to be markers of cardiovascular and inflammatory disease in humans. Multiple linear regression models adjusted for maternal age, parity, pre-conception BMI, height, and smoking were performed to evaluate the association of each individual protein with infant birth size. We also performed sex-stratified analyses. Eight proteins (Matrix metalloproteinase-12 (MMP-12), Prostasin (PRSS8), Adrenomedullin (ADM), Pappalysin-1 (PAPP-A), Angiotensin-converting enzyme 2 (ACE2), Sortilin (SORT1), Lectin-like oxidized LDL receptor 1 (LOX-1), and Thrombomodulin (TM)) were associated with infant birth size after false discovery rate adjustment. In the analyses including only female infants, ten proteins (MMP-12, Growth/differentiation factor 2 (GDF-2), PRSS8, SORT1, ADM, Interleukin-1 receptor antagonist protein (IL-1ra), Leptin (LEP), ACE2, TM, and Tumor necrosis factor receptor superfamily member 11A (TNFRSF11A)) were associated with infant birth size. Two proteins (PAPP-A and PRSS8) were associated with infant birth size among male infants. Our study suggests several proteins as potential biomarkers for increased birth weight, and our findings could act as a base for future research to identify new potential markers that could be added to improve screening for large infants.


Assuntos
Enzima de Conversão de Angiotensina 2 , Proteína Plasmática A Associada à Gravidez , Gravidez , Criança , Humanos , Lactente , Masculino , Feminino , Adulto , Metaloproteinase 12 da Matriz , Peso ao Nascer , Biomarcadores , Proteínas Sanguíneas
10.
BMJ Health Care Inform ; 29(1)2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36455992

RESUMO

OBJECTIVE: Inadequate adherence to resuscitation for non-crying infants will have poor outcome and thus rationalise a need for real-time guidance and quality improvement technology. This study assessed the usability, feasibility and acceptability of a novel technology of real-time visual guidance, with sound and video recording during resuscitation. SETTING: A public hospital in Nepal. DESIGN: A cross-sectional design. INTERVENTION: The technology has an infant warmer with light, equipped with a tablet monitor, NeoBeat and upright bag and mask. The tablet records resuscitation activities, ventilation sound, heart rate and display time since birth. Healthcare providers (HCPs) were trained on the technology before piloting. DATA COLLECTION AND ANALYSIS: HCPs who had at least 8 weeks of experience using the technology completed a questionnaire on usability, feasibility and acceptability (ranged 1-5 scale). Overall usability score was calculated (ranged 1-100 scale). RESULTS: Among the 30 HCPs, 25 consented to the study. The usability score was good with the mean score (SD) of 68.4% (10.4). In terms of feasibility, the participants perceived that they did not receive adequate support from the hospital administration for use of the technology, mean score (SD) of 2.44 (1.56). In terms of acceptability, the information provided in the monitor, that is, time elapsed from birth was easy to understand with mean score (SD) of 4.60 (0.76). CONCLUSION: The study demonstrates reasonable usability, feasibility and acceptability of a technological solution that records audio visual events during resuscitation and provides visual guidance to improve care.


Assuntos
Pessoal de Saúde , Tecnologia , Lactente , Recém-Nascido , Humanos , Projetos Piloto , Estudos Transversais , Estudos de Viabilidade
11.
Neonatology ; 119(6): 745-752, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36108597

RESUMO

INTRODUCTION: Hyperglycemia in very preterm infants is associated with increased morbidity and mortality. We aimed to investigate potential associations between early hyperglycemia, neonatal cerebral magnetic resonance imaging (MRI), and neurodevelopment at 2.5 years. METHODS: The study population included 69 infants with gestational age (GA) 22.3-31.9 weeks (n = 29 with GA <28 weeks), born 2011-2014. Plasma glucose concentrations during the first week were checked according to clinical routines. Hyperglycemia was defined as glucose concentrations above 8.3 mmol/L (150 mg/dL) and above 10 mmol/L (180 mg/dL), respectively, categorized as the highest glucose days 0-2, number of days above 8.3 and 10 mmol/L, and prolonged (yes/no) 2 days or more above 8.3 and 10 mmol/L. The MRI analysis included morphological assessment, regional brain volumes, and assessment of apparent diffusion coefficient (ADC). Neurodevelopmental impairment (NDI) developed in 13 of 67 infants with available outcomes, of which 57 were assessed with the Bayley-III. Univariate and multiple linear and logistic regressions were performed with adjustments for GA, birth weight z-scores, and illness severity expressed as days on mechanical ventilation. RESULTS: Hyperglycemia above 8.3 mmol/L and 10 mmol/L was present in 47.8% and 31.9% of the infants. Hyperglycemia correlated independently with lower white matter volume, but not with other regional brain volumes, and was also associated with lower ADC values in white matter. Hyperglycemia also correlated with lower Bayley-III cognitive and motor scores in infants with GA <28 weeks, but there was no significant effect on NDI. CONCLUSION: Early hyperglycemia is associated with white matter injury and poorer neurodevelopment in very preterm infants.


Assuntos
Substância Branca , Recém-Nascido , Humanos , Lactente , Substância Branca/diagnóstico por imagem , Recém-Nascido Prematuro , Cognição , Glucose
12.
Acta Paediatr ; 111(9): 1701-1708, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35615868

RESUMO

AIM: The aim of this study was to investigate the associations between sodium supply, fluid volume, sodium imbalances and severe intraventricular haemorrhage (IVH) in extremely preterm (EPT) infants. METHODS: We used data from the EXtremely PREterm infants in Sweden Study (EXPRESS) cohort consisting of all infants born at 22 to 26 gestational weeks from 2004 to 2007 and conducted a nested case-control study. For every infant with severe IVH (grade 3 or peri-ventricular haemorrhagic infarction), one IVH-free control infant with the birthday closest to the case infant and matched for hospital, sex, gestational age and birth weight was selected (n = 70 case-control pairs). RESULTS: Total sodium supply and fluid volume were higher in infants with severe IVH compared with controls [daily total sodium supply until postnatal Day 2: mean ± SD (mmol/kg/day): 5.49 ± 2.53 vs. 3.95 ± 1.91, p = 0.009]. These differences were accounted for by sodium and fluid from transfused blood products. High plasma sodium concentrations or large sodium fluctuations were not associated with severe IVH. CONCLUSION: Our results suggest a relationship between sodium-rich transfusions of blood products and severe IVH in EPT infants. It is unclear whether this is an effect of sodium load, volume load or some other transfusion-related factor.


Assuntos
Lactente Extremamente Prematuro , Doenças do Prematuro , Estudos de Casos e Controles , Hemorragia Cerebral/etiologia , Idade Gestacional , Humanos , Lactente , Recém-Nascido , Sódio
13.
Nutrients ; 14(4)2022 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-35215444

RESUMO

The optimal fluid requirements for extremely preterm infants are not fully known. We examined retrospectively the fluid intakes during the first week of life in two cohorts of extremely preterm infants born at 22-26 weeks of gestation before (n = 63) and after a change from a restrictive to a more liberal (n = 112) fluid volume allowance to improve nutrient provision. The cohorts were similar in gestational age and birth weight, but antenatal steroid exposure was more frequent in the second era. Although fluid management resulted in a cumulative difference in the total fluid intake over the first week of 87 mL/kg (p < 0.001), this was not reflected in a mean weight loss (14 ± 5% at a postnatal age of 4 days in both groups) or mean peak plasma sodium (142 ± 5 and 143 ± 5 mmol/L in the restrictive and liberal groups, respectively). The incidences of hypernatremia (>145 and >150 mmol/L), PDA ligation, bronchopulmonary dysplasia, and IVH were also similar. We conclude that in this cohort of extremely preterm infants a more liberal vs. a restricted fluid allowance during the first week had no clinically important influence on early changes in body weight, sodium homeostasis, or hospital morbidities.


Assuntos
Displasia Broncopulmonar , Hipernatremia , Displasia Broncopulmonar/epidemiologia , Displasia Broncopulmonar/etiologia , Displasia Broncopulmonar/prevenção & controle , Feminino , Idade Gestacional , Humanos , Lactente , Lactente Extremamente Prematuro , Recém-Nascido , Gravidez , Estudos Retrospectivos , Sódio
14.
Reprod Sci ; 29(8): 2333-2341, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35147910

RESUMO

The objective of this study was to examine the associations of early mid-pregnancy ultrasound measured visceral and subcutaneous fat depths with blood-based protein biomarkers. This was a cross-sectional study including 201 pregnant women at Uppsala University Hospital, Sweden. The mean age of the women was 31.0 years, and 57.7% were nulliparous. Maternal visceral and subcutaneous fat depths were measured by ultrasound at the early second-trimester anomaly scan. A non-fasting blood sample was collected in conjunction with the second-trimester anomaly scan, and the Olink cardiovascular II panel was used to measure 92 blood-based protein biomarkers in the sample. Cross-sectional associations of visceral and subcutaneous fat depths with blood-based protein biomarkers were examined using Mann-Whitney U tests with false discovery rate adjustments. In addition, linear regression analyses adjusting for maternal age, parity, and early pregnancy body mass index were performed. The results showed differences in one biomarker between women with elevated (≥ 52 mm) versus normal (< 52 mm) visceral fat depth, and in three biomarkers between women with elevated (≥ 22 mm) versus normal (< 22 mm) subcutaneous fat depth. Hence, levels of blood-based protein biomarkers differ between pregnant women with dissimilar body fat distributions, which might reflect disparities in biological pathways.


Assuntos
Gordura Abdominal , Gordura Intra-Abdominal , Gordura Abdominal/diagnóstico por imagem , Gordura Abdominal/metabolismo , Adulto , Biomarcadores , Índice de Massa Corporal , Estudos Transversais , Feminino , Humanos , Gordura Intra-Abdominal/diagnóstico por imagem , Gravidez
15.
Sci Rep ; 12(1): 1832, 2022 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-35115625

RESUMO

The objective of this study was to evaluate the relationship between random capillary glucose levels in healthy pregnant women and infant size at birth and childhood growth to the age of five years. This population-based cohort study comprised 10,937 healthy mother-child dyads. Data on highest maternal random capillary glucose level during pregnancy and sequential anthropometric data on their children during the first five years of life were gathered from the Uppsala County Mother and Child Cohort. Statistical analyses were performed with linear regression and linear mixed effect regression models. We found that higher glucose level during pregnancy was associated with higher weight z-score (ß 0.10, 95% confidence interval (CI) 0.08-0.11), length z-score (ß 0.05, 95% CI 0.03-0.07) and BMI z-score (ß 0.09, 95% CI 0.07-0.12) at birth, adjusted for maternal BMI and country of birth, smoking during pregnancy and parity. The association did not remain at 1½, 3, 4 and 5 years of age. There was a positive relationship between higher glucose level during pregnancy and a decrease in weight z-score, height z-score and BMI z-score from birth to 5 years of age. In conclusion, higher random capillary glucose levels in pregnant healthy women were associated with greater infant size at birth, as well as decreased growth velocity in early childhood.


Assuntos
Peso ao Nascer/fisiologia , Glicemia/metabolismo , Desenvolvimento Infantil/fisiologia , Antropometria , Estatura , Índice de Massa Corporal , Pré-Escolar , Estudos de Coortes , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Paridade/fisiologia , Gravidez , Análise de Regressão , Fatores de Risco , Fumar/fisiopatologia
17.
J Dev Orig Health Dis ; 13(5): 650-655, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35000649

RESUMO

This study aimed to investigate how maternal birthweight is related to early pregnancy obesity, gestational diabetes mellitus (GDM), and offspring birthweight. Females born term and singleton in Sweden between 1973 and 1995 (N = 305,893) were studied at their first pregnancy. Information regarding their birthweight, early pregnancy body mass index, and pregnancy complications was retrieved from the Swedish Medical Birth Register, as were data on their mothers and offspring. High maternal birthweights (2-3 standard deviation scores (SDS) and >3 SDS) were associated with greater odds of early pregnancy obesity, odds ratio (OR) 1.52 (95% confidence interval (CI) 1.42-1.63) and OR 2.06 (CI 1.71-2.49), respectively. A low maternal birthweight (<2 SDS) was associated with greater odds of GDM (OR 2.49, CI 2.00-3.12). No association was found between high maternal birthweight and GDM. A maternal birthweight 2-3 SDS was associated with offspring birthweight 2-3 SDS (OR 3.83, CI 3.44-4.26), and >3 SDS (OR 3.55, CI 2.54-4.97). Corresponding ORs for a maternal birthweight >3 SDS were 5.38 (CI 4.12-7.01) and 6.98 (CI 3.57-13.65), respectively. In conclusion, a high maternal birthweight was positively associated with early pregnancy obesity and offspring macrosomia. A low, but not a high maternal birthweight, was associated with GDM.


Assuntos
Diabetes Gestacional , Doenças do Recém-Nascido , Peso ao Nascer , Índice de Massa Corporal , Diabetes Gestacional/epidemiologia , Feminino , Macrossomia Fetal/epidemiologia , Macrossomia Fetal/etiologia , Humanos , Recém-Nascido , Obesidade/complicações , Obesidade/epidemiologia , Gravidez , Aumento de Peso
18.
Acta Paediatr ; 111(3): 536-545, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34822182

RESUMO

AIM: It is challenging to provide extremely low gestational age neonates (ELGANs) with adequate protein supply. This study aimed to investigate whether amino acid (AA) infusion in the umbilical artery catheter (UAC) in ELGANs is safe and enhances protein supply and growth. METHOD: A before and after study including infants born <27 weeks, treated in Uppsala, Sweden, during 2004-2007, compared those receiving normal saline/10% dextrose in water with those receiving AA infusion in the UAC. Data were retrieved from the Extremely Preterm Infants in Sweden Study, hospital records and the Swedish Neonatal Quality Register. Group comparisons, univariate and multivariate analyses were conducted. RESULTS: AA group (n = 41, females 39%) received on average approximately 0.3 g/kg/day more protein during the first postnatal week, compared to control group (n = 30, females 40%) (unstandardised coefficient (B) 0.26, p .001) but no difference was noted during 8-28 postnatal days. The type of infusion was not associated with growth variables. The incidence of neonatal morbidities and UAC-related thrombosis did not differ between the groups. CONCLUSION: AA infusions in the UACs in ELGANs is safe and enhances protein supply during the first postnatal week. However, this practice is not associated with growth during the first 28 postnatal days.


Assuntos
Aminoácidos , Artérias Umbilicais , Catéteres , Feminino , Idade Gestacional , Humanos , Lactente , Lactente Extremamente Prematuro , Recém-Nascido
20.
Nutrients ; 13(6)2021 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-34198748

RESUMO

The objective of this study was to investigate factors influencing fat loss during tube feeding of breast milk to preterm infants. An experimental study with 81 feeding simulations was performed, with nine continuous infusions in each of six modalities: Horizontal Higher, Horizontal Matched, Horizontal Lower, Tilted Higher, Tilted Matched, and Tilted Lower, and for comparison, 27 bolus feedings: nine flushed with air, nine with water, and nine that were not flushed, done at matched height. Each simulation utilized 16 mL of breast milk given over four hours. Continuous infusions were given with a flow rate of 4 mL/h. Bolus was given as 8 mL over the course of 15-20 min every other hour. Analysis for fat, true protein, carbohydrate, total solids, and energy was performed before and after each simulation. The percent of macronutrient loss was compared between all simulations. Continuous infusion resulted in an average fat loss of 40%. Bolus feedings resulted in an average fat loss of 11% (p ≤ 0.001). Considerable fat loss is seen during continuous tube feeding. Neither height in relation to the infant nor tilting of the pump reduce fat loss. To limit fat loss, the bolus feeding method should be utilized.


Assuntos
Nutrição Enteral/instrumentação , Nutrição Enteral/métodos , Leite Humano , Métodos de Alimentação , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal , Intubação Gastrointestinal/instrumentação , Intubação Gastrointestinal/métodos , Nutrientes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...