Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Opt Express ; 15(4): 2293-2307, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38633091

RESUMO

Programmable nanoscale carriers, such as liposomes and DNA, are readily being explored for personalized medicine or disease prediction and diagnostics. The characterization of these nanocarriers is limited and challenging due to their complex chemical composition. Here, we demonstrate the utilization of surface-enhanced Raman spectroscopy (SERS), which provides a unique molecular fingerprint of the analytes while reducing the detection limit. In this paper, we utilize a silver coated nano-bowl shaped polydimethylsiloxane (PDMS) SERS substrate. The utilization of nano-bowl surface topology enabled the passive trapping of particles by reducing mobility, which results in reproducible SERS signal enhancement. The biological nanoparticles' dwell time in the nano-trap was in the order of minutes, thus allowing SERS spectra to remain in their natural aqueous medium without the need for drying. First, the geometry of the nano-traps was designed considering nanosized bioparticles of 50-150 nm diameter. Further, the systematic investigation of maximum SERS activity was performed using rhodamine 6 G as a probe molecule. The potential of the optimized SERS nano-bowl is shown through distinct spectral features following surface- (polyethylene glycol) and bilayer- (cholesterol) modification of empty liposomes of around 140 nm diameter. Apart from liposomes, the characterization of the highly crosslinked DNA specimens of only 60 nm in diameter was performed. The modification of DNA gel by liposome coating exhibited unique signatures for nitrogenous bases, sugar, and phosphate groups. Further, the unique sensitivity of the proposed SERS substrate displayed distinct spectral signatures for DNA micelles and drug-loaded DNA micelles, carrying valuable information to monitor drug release. In conclusion, the findings of the spectral signatures of a wide range of molecular complexes and chemical morphology of intra-membranes in their natural state highlight the possibilities of using SERS as a sensitive and instantaneous characterization alternative.

2.
Sci Rep ; 13(1): 13390, 2023 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-37591901

RESUMO

Xanthines such as caffeine and theobromine are among the most consumed psychoactive stimulants in the world, either as natural components of coffee, tea and chocolate, or as added ingredients. The present study assessed if xanthines affect liver sinusoidal endothelial cells (LSEC). Cultured primary rat LSEC were challenged with xanthines at concentrations typically obtained from normal consumption of xanthine-containing beverages, food or medicines; and at higher concentrations below the in vitro toxic limit. The fenestrated morphology of LSEC were examined with scanning electron and structured illumination microscopy. All xanthine challenges had no toxic effects on LSEC ultrastructure as judged by LSEC fenestration morphology, or function as determined by endocytosis studies. All xanthines in high concentrations (150 µg/mL) increased fenestration frequency but at physiologically relevant concentrations, only theobromine (8 µg/mL) showed an effect. LSEC porosity was influenced only by high caffeine doses which also shifted the fenestration distribution towards smaller pores. Moreover, a dose-dependent increase in fenestration number was observed after caffeine treatment. If these compounds induce similar changes in vivo, age-related reduction of LSEC porosity can be reversed by oral treatment with theobromine or with other xanthines using targeted delivery.


Assuntos
Cafeína , Teobromina , Animais , Ratos , Cafeína/farmacologia , Xantina , Teobromina/farmacologia , Células Endoteliais , Fígado
3.
ACS Appl Mater Interfaces ; 15(20): 24047-24058, 2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37158639

RESUMO

Antimicrobial resistance (AMR) is a major health threat worldwide and the culture-based bacterial detection methods are slow. Surface-enhanced Raman spectroscopy (SERS) can be used to identify target analytes in real time with sensitivity down to the single-molecule level, providing a promising solution for the culture-free bacterial detection. We report the fabrication of SERS substrates having tightly packed silver (Ag) nanoparticles loaded onto long silicon nanowires (Si NWs) grown by the metal-assisted chemical etching (MACE) method for the detection of bacteria. The optimized SERS chips exhibited sensitivity down to 10-12 M concentration of R6G molecules and detected reproducible Raman spectra of bacteria down to a concentration of 100 colony forming units (CFU)/mL, which is a thousand times lower than the clinical threshold of bacterial infections like UTI (105 CFU/mL). A Siamese neural network model was used to classify SERS spectra from bacteria specimens. The trained model identified 12 different bacterial species, including those which are causative agents for tuberculosis and urinary tract infection (UTI). Next, the SERS chips and another Siamese neural network model were used to differentiate AMR strains from susceptible strains of Escherichia coli (E. coli). The enhancement offered by SERS chip-enabled acquisitions of Raman spectra of bacteria directly in the synthetic urine by spiking the sample with only 103 CFU/mL E. coli. Thus, the present study lays the ground for the identification and quantification of bacteria on SERS chips, thereby offering a potential future use for rapid, reproducible, label-free, and low limit detection of clinical pathogens.


Assuntos
Nanopartículas Metálicas , Nanofios , Antibacterianos , Escherichia coli/química , Análise Espectral Raman/métodos , Bactérias , Nanopartículas Metálicas/química
4.
Sensors (Basel) ; 23(4)2023 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-36850374

RESUMO

This study aims to demonstrate the generation and detection of Scholte waves inside polystyrene microparticles. This was proven using both experimental analysis and COMSOL simulation. Microspheres of different sizes were excited optically with a pulsed laser (532 nm), and the acoustic signals were detected using a transducer (40 MHz). On analyzing the laser-generated ultrasound signals, the results obtained experimentally and from COMSOL are in close agreement both in the time and frequency domain. A simplified analysis of Scholte wave generation by laser irradiation for homogeneous, isotropic microspheres is presented. The theoretical wave velocity of the Scholte wave was calculated and found close to our experimental results. A representation of pressure wave motion showing the Scholte wave generation is presented at different times.

5.
Sci Rep ; 13(1): 1453, 2023 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-36702876

RESUMO

We present experimental demonstration of tilt-mirror assisted transmission structured illumination microscopy (tSIM) that offers a large field of view super resolution imaging. An assembly of custom-designed tilt-mirrors are employed as the illumination module where the sample is excited with the interference of two beams reflected from the opposite pair of mirror facets. Tunable frequency structured patterns are generated by changing the mirror-tilt angle and the hexagonal-symmetric arrangement is considered for the isotropic resolution in three orientations. Utilizing high numerical aperture (NA) objective in standard SIM provides super-resolution compromising with the field-of-view (FOV). Employing low NA (20X/0.4) objective lens detection, we experimentally demonstrate [Formula: see text] (0.56 mm[Formula: see text]0.35 mm) size single FOV image with [Formula: see text]1.7- and [Formula: see text]2.4-fold resolution improvement (exploiting various illumination by tuning tilt-mirrors) over the diffraction limit. The results are verified both for the fluorescent beads as well as biological samples. The tSIM geometry decouples the illumination and the collection light paths consequently enabling free change of the imaging objective lens without influencing the spatial frequency of the illumination pattern that are defined by the tilt-mirrors. The large and scalable FOV supported by tSIM will find usage for applications where scanning large areas are necessary as in pathology and applications where images must be correlated both in space and time.

6.
Int J Mol Sci ; 23(17)2022 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-36077249

RESUMO

Liver sinusoidal endothelial cells (LSECs) facilitate the efficient transport of macromolecules and solutes between the blood and hepatocytes. The efficiency of this transport is realized via transcellular nanopores, called fenestrations. The mean fenestration size is 140 ± 20 nm, with the range from 50 nm to 350 nm being mostly below the limits of diffraction of visible light. The cellular mechanisms controlling fenestrations are still poorly understood. In this study, we tested a hypothesis that both Rho kinase (ROCK) and myosin light chain (MLC) kinase (MLCK)-dependent phosphorylation of MLC regulates fenestrations. We verified the hypothesis using a combination of several molecular inhibitors and by applying two high-resolution microscopy modalities: structured illumination microscopy (SIM) and scanning electron microscopy (SEM). We demonstrated precise, dose-dependent, and reversible regulation of the mean fenestration diameter within a wide range from 120 nm to 220 nm and the fine-tuning of the porosity in a range from ~0% up to 12% using the ROCK pathway. Moreover, our findings indicate that MLCK is involved in the formation of new fenestrations-after inhibiting MLCK, closed fenestrations cannot be reopened with other agents. We, therefore, conclude that the Rho-ROCK pathway is responsible for the control of the fenestration diameter, while the inhibition of MLCK prevents the formation of new fenestrations.


Assuntos
Actinas , Cadeias Leves de Miosina , Actinas/metabolismo , Animais , Células Endoteliais/metabolismo , Hepatócitos/metabolismo , Fígado/metabolismo , Camundongos , Microscopia Eletrônica de Varredura , Cadeias Leves de Miosina/metabolismo , Quinase de Cadeia Leve de Miosina/metabolismo , Fosforilação , Quinases Associadas a rho/metabolismo
7.
Sci Rep ; 12(1): 10869, 2022 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-35760816

RESUMO

Dynamic speckle illumination (DSI) has recently attracted strong attention in the field of biomedical imaging as it pushes the limits of interference microscopy (IM) in terms of phase sensitivity, and spatial and temporal resolution compared to conventional light source illumination. To date, despite conspicuous advantages, it has not been extensively implemented in the field of phase imaging due to inadequate understanding of interference fringe formation, which is challenging to obtain in dynamic speckle illumination interference microscopy (DSI-IM). The present article provides the basic understanding of DSI through both simulation and experiments that is essential to build interference microscopy systems such as quantitative phase microscopy, digital holographic microscopy and optical coherence tomography. Using the developed understanding of DSI, we demonstrated its capabilities which enables the use of non-identical objective lenses in both arms of the interferometer and opens the flexibility to use user-defined microscope objective lens for scalable field of view and resolution phase imaging. It is contrary to the present understanding which forces us to use identical objective lenses in conventional IM system and limits the applicability of the system for fixed objective lens. In addition, it is also demonstrated that the interference fringes are not washed out over a large range of optical path difference (OPD) between the object and the reference arm providing competitive edge over low temporal coherence light source based IM system. The theory and explanation developed here would enable wider penetration of DSI-IM for applications in biology and material sciences.


Assuntos
Holografia , Lentes , Holografia/métodos , Iluminação , Microscopia/métodos , Microscopia de Interferência/métodos
8.
Sci Data ; 9(1): 98, 2022 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-35322035

RESUMO

This three-dimensional structured illumination microscopy (3DSIM) dataset was generated to highlight the suitability of 3DSIM to investigate mitochondria-derived vesicles (MDVs) in H9c2 cardiomyoblasts in living or fixed cells. MDVs act as a mitochondria quality control mechanism. The cells were stably expressing the tandem-tag eGFP-mCherry-OMP25-TM (outer mitochondrial membrane) which can be used as a sensor for acidity. A part of the dataset is showing correlative imaging of lysosomes labeled using LysoTracker in fixed and living cells. The cells were cultivated in either normal or glucose-deprived medium containing galactose. The resulting 3DSIM data were of high quality and can be used to undertake a variety of studies. Interestingly, many dynamic tubules derived from mitochondria are visible in the 3DSIM videos under both glucose and galactose-adapted growth conditions. As the raw 3DSIM data, optical parameters, and reconstructed 3DSIM images are provided, the data is especially suitable for use in the development of SIM reconstruction algorithms, bioimage analysis methods, and for biological studies of mitochondria.


Assuntos
Galactose , Lisossomos , Mitocôndrias , Mioblastos Cardíacos , Animais , Glucose , Iluminação , Microscopia , Mioblastos Cardíacos/ultraestrutura , Ratos
9.
Light Sci Appl ; 11(1): 43, 2022 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-35210400

RESUMO

Histology involves the observation of structural features in tissues using a microscope. While diffraction-limited optical microscopes are commonly used in histological investigations, their resolving capabilities are insufficient to visualize details at subcellular level. Although a novel set of super-resolution optical microscopy techniques can fulfill the resolution demands in such cases, the system complexity, high operating cost, lack of multi-modality, and low-throughput imaging of these methods limit their wide adoption for histological analysis. In this study, we introduce the photonic chip as a feasible high-throughput microscopy platform for super-resolution imaging of histological samples. Using cryopreserved ultrathin tissue sections of human placenta, mouse kidney, pig heart, and zebrafish eye retina prepared by the Tokuyasu method, we demonstrate diverse imaging capabilities of the photonic chip including total internal reflection fluorescence microscopy, intensity fluctuation-based optical nanoscopy, single-molecule localization microscopy, and correlative light-electron microscopy. Our results validate the photonic chip as a feasible imaging platform for tissue sections and pave the way for the adoption of super-resolution high-throughput multimodal analysis of cryopreserved tissue samples both in research and clinical settings.

10.
J Biophotonics ; 15(2): e202100305, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34766731

RESUMO

Mitochondria are essential energy-providing organelles of particular importance in energy-demanding tissue such as the heart. The production of mitochondria-derived vesicles (MDVs) is a cellular mechanism by which cells ensure a healthy pool of mitochondria. These vesicles are small and fast-moving objects not easily captured by imaging. In this work, we have tested the ability of the optical super-resolution technique 3DSIM to capture high-resolution images of MDVs. We optimized the imaging conditions both for high-speed video microscopy and fixed-cell imaging and analysis. From the 3DSIM videos, we observed an abundance of MDVs and many dynamic mitochondrial tubules. The density of MDVs in cells was compared for cells under normal growth conditions and cells during metabolic perturbation. Our results indicate a higher abundance of MDVs in H9c2 cells during glucose deprivation compared with cells under normal growth conditions. Furthermore, the results reveal a large untapped potential of 3DSIM in MDV research.


Assuntos
Microscopia , Dinâmica Mitocondrial , Iluminação , Mitocôndrias/metabolismo
11.
Nanophotonics ; 11(15): 3421-3436, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38144043

RESUMO

The article elucidates the physical mechanism behind the generation of superior-contrast and high-resolution label-free images using an optical waveguide. Imaging is realized by employing a high index contrast multi-moded waveguide as a partially coherent light source. The modes provide near-field illumination of unlabeled samples, thereby repositioning the higher spatial frequencies of the sample into the far-field. These modes coherently scatter off the sample with different phases and are engineered to have random spatial distributions within the integration time of the camera. This mitigates the coherent speckle noise and enhances the contrast (2-10) × as opposed to other imaging techniques. Besides, the coherent scattering of the different modes gives rise to fluctuations in intensity. The technique demonstrated here is named chip-based Evanescent Light Scattering (cELS). The concepts introduced through this work are described mathematically and the high-contrast image generation process using a multi-moded waveguide as the light source is explained. The article then explores the feasibility of utilizing fluctuations in the captured images along with fluorescence-based techniques, like intensity-fluctuation algorithms, to mitigate poor-contrast and diffraction-limited resolution in the coherent imaging regime. Furthermore, a straight waveguide is demonstrated to have limited angular diversity between its multiple modes and therefore, for isotropic sample illumination, a multiple-arms waveguide geometry is used. The concepts introduced are validated experimentally via high-contrast label-free imaging of weakly scattering nanosized specimens such as extra-cellular vesicles (EVs), liposomes, nanobeads and biological cells such as fixed and live HeLa cells.

12.
Proc Natl Acad Sci U S A ; 118(47)2021 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-34782474

RESUMO

Visualization of three-dimensional (3D) morphological changes in the subcellular structures of a biological specimen is a major challenge in life science. Here, we present an integrated chip-based optical nanoscopy combined with quantitative phase microscopy (QPM) to obtain 3D morphology of liver sinusoidal endothelial cells (LSEC). LSEC have unique morphology with small nanopores (50-300 nm in diameter) in the plasma membrane, called fenestrations. The fenestrations are grouped in discrete clusters, which are around 100 to 200 nm thick. Thus, imaging and quantification of fenestrations and sieve plate thickness require resolution and sensitivity of sub-100 nm along both the lateral and the axial directions, respectively. In chip-based nanoscopy, the optical waveguides are used both for hosting and illuminating the sample. The fluorescence signal is captured by an upright microscope, which is converted into a Linnik-type interferometer to sequentially acquire both superresolved images and phase information of the sample. The multimodal microscope provided an estimate of the fenestration diameter of 119 ± 53 nm and average thickness of the sieve plates of 136.6 ± 42.4 nm, assuming the constant refractive index of cell membrane to be 1.38. Further, LSEC were treated with cytochalasin B to demonstrate the possibility of precise detection in the cell height. The mean phase value of the fenestrated area in normal and treated cells was found to be 161 ± 50 mrad and 109 ± 49 mrad, respectively. The proposed multimodal technique offers nanoscale visualization of both the lateral size and the thickness map, which would be of broader interest in the fields of cell biology and bioimaging.


Assuntos
Células Endoteliais/patologia , Endotélio/diagnóstico por imagem , Endotélio/patologia , Fígado/diagnóstico por imagem , Microscopia/métodos , Animais , Membrana Celular , Endotélio/metabolismo , Fluorescência , Hepatócitos/patologia , Imageamento Tridimensional/métodos , Fígado/metabolismo , Fígado/patologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Microscopia/instrumentação , Ratos , Ratos Sprague-Dawley
13.
Biomed Opt Express ; 12(9): 5529-5543, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34692199

RESUMO

Contrast in fluorescence microscopy images allows for the differentiation between different structures by their difference in intensities. However, factors such as point-spread function and noise may reduce it, affecting its interpretability. We identified that fluctuation of emitters in a stack of images can be exploited to achieve increased contrast when compared to the average and Richardson-Lucy deconvolution. We tested our methods on four increasingly challenging samples including tissue, in which case results were comparable to the ones obtained by structured illumination microscopy in terms of contrast.

14.
Sci Rep ; 11(1): 15850, 2021 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-34349138

RESUMO

High space-bandwidth product with high spatial phase sensitivity is indispensable for a single-shot quantitative phase microscopy (QPM) system. It opens avenue for widespread applications of QPM in the field of biomedical imaging. Temporally low coherence light sources are implemented to achieve high spatial phase sensitivity in QPM at the cost of either reduced temporal resolution or smaller field of view (FOV). In addition, such light sources have low photon degeneracy. On the contrary, high temporal coherence light sources like lasers are capable of exploiting the full FOV of the QPM systems at the expense of less spatial phase sensitivity. In the present work, we demonstrated that use of narrowband partially spatially coherent light source also called pseudo-thermal light source (PTLS) in QPM overcomes the limitations of conventional light sources. The performance of PTLS is compared with conventional light sources in terms of space bandwidth product, phase sensitivity and optical imaging quality. The capabilities of PTLS are demonstrated on both amplitude (USAF resolution chart) and phase (thin optical waveguide, height ~ 8 nm) objects. The spatial phase sensitivity of QPM using PTLS is measured to be equivalent to that for white light source and supports the FOV (18 times more) equivalent to that of laser light source. The high-speed capabilities of PTLS based QPM is demonstrated by imaging live sperm cells that is limited by the camera speed and large FOV is demonstrated by imaging histopathology human placenta tissue samples. Minimal invasive, high-throughput, spatially sensitive and single-shot QPM based on PTLS will enable wider penetration of QPM in life sciences and clinical applications.

15.
J Cell Biol ; 220(8)2021 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-34037656

RESUMO

Mitophagy is the degradation of surplus or damaged mitochondria by autophagy. In addition to programmed and stress-induced mitophagy, basal mitophagy processes exert organelle quality control. Here, we show that the sorting and assembly machinery (SAM) complex protein SAMM50 interacts directly with ATG8 family proteins and p62/SQSTM1 to act as a receptor for a basal mitophagy of components of the SAM and mitochondrial contact site and cristae organizing system (MICOS) complexes. SAMM50 regulates mitochondrial architecture by controlling formation and assembly of the MICOS complex decisive for normal cristae morphology and exerts quality control of MICOS components. To this end, SAMM50 recruits ATG8 family proteins through a canonical LIR motif and interacts with p62/SQSTM1 to mediate basal mitophagy of SAM and MICOS components. Upon metabolic switch to oxidative phosphorylation, SAMM50 and p62 cooperate to mediate efficient mitophagy.


Assuntos
Proteínas de Membrana/metabolismo , Mitocôndrias/metabolismo , Proteínas Mitocondriais/metabolismo , Mitofagia , Fosforilação Oxidativa , Proteína Sequestossoma-1/metabolismo , Animais , Família da Proteína 8 Relacionada à Autofagia/genética , Família da Proteína 8 Relacionada à Autofagia/metabolismo , Células HEK293 , Células HeLa , Humanos , Proteínas de Membrana/genética , Camundongos , Microscopia Confocal , Microscopia Eletrônica de Transmissão , Microscopia de Fluorescência , Mitocôndrias/genética , Mitocôndrias/ultraestrutura , Proteínas do Complexo de Importação de Proteína Precursora Mitocondrial , Proteínas Mitocondriais/genética , Ligação Proteica , Domínios e Motivos de Interação entre Proteínas , Proteína Sequestossoma-1/genética , Transdução de Sinais
16.
Pharmaceutics ; 13(5)2021 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-33919040

RESUMO

The rapid development of nanomedicine and drug delivery systems calls for new and effective characterization techniques that can accurately characterize both the properties and the behavior of nanosystems. Standard methods such as dynamic light scattering (DLS) and fluorescent-based assays present challenges in terms of system's instability, machine sensitivity, and loss of tracking ability, among others. In this study, we explore some of the downsides of batch-mode analyses and fluorescent labeling, while introducing quantitative phase microscopy (QPM) as a label-free complimentary characterization technique. Liposomes were used as a model nanocarrier for their therapeutic relevance and structural versatility. A successful immobilization of liposomes in a non-dried setup allowed for static imaging conditions in an off-axis phase microscope. Image reconstruction was then performed with a phase-shifting algorithm providing high spatial resolution. Our results show the potential of QPM to localize subdiffraction-limited liposomes, estimate their size, and track their integrity over time. Moreover, QPM full-field-of-view images enable the estimation of a single-particle-based size distribution, providing an alternative to the batch mode approach. QPM thus overcomes some of the drawbacks of the conventional methods, serving as a relevant complimentary technique in the characterization of nanosystems.

17.
Opt Express ; 28(24): 35454-35468, 2020 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-33379659

RESUMO

Photonic-chip based TIRF illumination has been used to demonstrate several on-chip optical nanoscopy methods. The sample is illuminated by the evanescent field generated by the electromagnetic wave modes guided inside the optical waveguide. In addition to the photokinetics of the fluorophores, the waveguide modes can be further exploited for introducing controlled intensity fluctuations for exploitation by techniques such as super-resolution optical fluctuation imaging (SOFI). However, the problem of non-uniform illumination pattern generated by the modes contribute to artifacts in the reconstructed image. To alleviate this problem, we propose to perform Haar wavelet kernel (HAWK) analysis on the original image stack prior to the application of (SOFI). HAWK produces a computational image stack with higher spatio-temporal sparsity than the original stack. In the case of multimoded non-uniform illumination patterns, HAWK processing breaks the mode pattern while introducing spatio-temporal sparsity, thereby differentially affecting the non-uniformity of the illumination. Consequently, this assists nanoscopy methods such as SOFI to better support super-resolution, which is otherwise compromised due to spatial correlation of the mode patterns in the raw image. Furthermore, applying HAWK prior to SOFI alleviates the problem of artifacts due to non-uniform illumination without degrading temporal resolution. Our experimental results demonstrate resolution enhancement as well as reduction in artifacts through the combination of HAWK and SOFI.

18.
Opt Express ; 28(24): 36229-36244, 2020 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-33379722

RESUMO

Quantitative phase microscopy (QPM) is a label-free technique that enables monitoring of morphological changes at the subcellular level. The performance of the QPM system in terms of spatial sensitivity and resolution depends on the coherence properties of the light source and the numerical aperture (NA) of objective lenses. Here, we propose high space-bandwidth quantitative phase imaging using partially spatially coherent digital holographic microscopy (PSC-DHM) assisted with a deep neural network. The PSC source synthesized to improve the spatial sensitivity of the reconstructed phase map from the interferometric images. Further, compatible generative adversarial network (GAN) is used and trained with paired low-resolution (LR) and high-resolution (HR) datasets acquired from the PSC-DHM system. The training of the network is performed on two different types of samples, i.e. mostly homogenous human red blood cells (RBC), and on highly heterogeneous macrophages. The performance is evaluated by predicting the HR images from the datasets captured with a low NA lens and compared with the actual HR phase images. An improvement of 9× in the space-bandwidth product is demonstrated for both RBC and macrophages datasets. We believe that the PSC-DHM + GAN approach would be applicable in single-shot label free tissue imaging, disease classification and other high-resolution tomography applications by utilizing the longitudinal spatial coherence properties of the light source.


Assuntos
Eritrócitos/citologia , Holografia/métodos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Macrófagos/citologia , Microscopia de Contraste de Fase/métodos , Redes Neurais de Computação , Humanos
19.
Commun Biol ; 3(1): 739, 2020 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-33288833

RESUMO

Correlative light and electron microscopy (CLEM) unifies the versatility of light microscopy (LM) with the high resolution of electron microscopy (EM), allowing one to zoom into the complex organization of cells. Here, we introduce photonic chip assisted CLEM, enabling multi-modal total internal reflection fluorescence (TIRF) microscopy over large field of view and high precision localization of the target area of interest within EM. The photonic chips are used as a substrate to hold, to illuminate and to provide landmarking of the sample through specially designed grid-like numbering systems. Using this approach, we demonstrate its applicability for tracking the area of interest, imaging the three-dimensional (3D) structural organization of nano-sized morphological features on liver sinusoidal endothelial cells such as fenestrations (trans-cytoplasmic nanopores), and correlating specific endo-lysosomal compartments with its cargo protein upon endocytosis.


Assuntos
Células Endoteliais , Microscopia/métodos , Óptica e Fotônica/instrumentação , Animais , Fígado/citologia , Masculino , Ratos , Ratos Sprague-Dawley
20.
J Biomed Opt ; 25(11)2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33179458

RESUMO

SIGNIFICANCE: High temporal stability, wavelength independency, and scalable field of view (FOV) are the primary requirements of a quantitative phase microscopy (QPM) system. The high temporal stability of the system provides accurate measurement of minute membrane fluctuations of the biological cells that can be an indicator of disease diagnosis. AIM: The main aim of this work is to develop a high temporal stable technique that can accurately quantify the cell's dynamics such as membrane fluctuations of human erythrocytes. Further, the technique should be capable of acquiring scalable FOV and resolution at multiple wavelengths to make it viable for various biological applications. APPROACH: We developed a single-element nearly common path, wavelength-independent, and scalable resolution/FOV QPM system to obtain temporally stable holograms/interferograms of the biological specimens. RESULTS: With the proposed system, the temporal stability is obtained ∼15 mrad without using any vibration isolation table. The capability of the proposed system is first demonstrated on USAF resolution chart and polystyrene spheres (4.5-µm diameter). Further, the system is implemented for single shot, wavelength-independent quantitative phase imaging of human red blood cells (RBCs) with scalable resolution using color CCD camera. The membrane fluctuation of healthy human RBCs is also measured and was found to be around 47 nm. CONCLUSIONS: Contrary to its optical counterparts, the present system offers an energy efficient, cost effective, and simple way of generating object and reference beam for the development of common-path QPM. The present system provides the flexibility to the user to acquire multi-wavelength quantitative phase images at scalable FOV and resolution.


Assuntos
Eritrócitos , Microscopia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...