Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Br J Ophthalmol ; 108(2): 217-222, 2024 01 29.
Artigo em Inglês | MEDLINE | ID: mdl-36593090

RESUMO

BACKGROUND/AIMS: To report a first-in-human trial in open-angle glaucoma (OAG) subjects treated with a new microinterventional biostent-reinforced cyclodialysis technique to enhance supraciliary aqueous drainage. METHODS: Subjects (N=10; 74.1±7.9 years old) with OAG and cataracts underwent combined phacoemulsification cataract surgery with implantation of a permanent endoscleral supraciliary biostent to reinforce a controlled cyclodialysis cleft. The biostent comprised decellularised scleral allograft tissue microtrephined into a polymer tubular implant intraoperative/postoperative safety, intraocular pressure (IOP) and glaucoma medications were tracked through 12 months postimplantation. RESULTS: Baseline medicated IOP averaged 24.2±6.9 mm Hg with subjects using 1.3±0.8 IOP-lowering medications. Successful biostent implantation was achieved in all individuals without significant complications. Immediate IOP lowering was sustained through 1 year. Twelve-month mean IOP was reduced 40% from baseline to 14.6±3.2 mm Hg (p=0.004; paired two-tailed t-test), and 80% of patients achieved >20% IOP reduction. Biostenting reduced glaucoma medication use 62%, from a baseline mean of 1.3 required medications to 0.5 medications (p=0.037) at postoperative 12 months. The biotissue implant was well tolerated and demonstrated good endothelial safety with only 11% endothelial cell loss at 12 months after combined phaco-biostenting surgery, similar to that expected after phacoemulsification alone. Mean BCVA increased from baseline 20/130 Snellen to 20/36 at postoperative 12 months (p=0.001). CONCLUSION: Supraciliary biostenting in OAG patients is well tolerated, has a good safety profile and produces long-term IOP-lowering while reducing glaucoma medication requirements.


Assuntos
Extração de Catarata , Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto , Glaucoma , Facoemulsificação , Idoso , Idoso de 80 Anos ou mais , Humanos , Extração de Catarata/métodos , Glaucoma/cirurgia , Glaucoma de Ângulo Aberto/tratamento farmacológico , Pressão Intraocular , Facoemulsificação/métodos , Stents , Resultado do Tratamento
2.
Ophthalmol Sci ; 4(1): 100349, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37869021

RESUMO

Objective: In a world where digital media is deeply engrained into our everyday lives, there lies an opportunity to leverage interactions with technology for health and wellness. The Vision Performance Index (VPI) leverages natural human-technology interaction to evaluate visual function using visual, cognitive, and motor psychometric data over 5 domains: field of view, accuracy, multitracking, endurance, and detection. The purpose of this study was to describe a novel method of evaluating holistic visual function through video game-derived VPI score data in patients with specific ocular pathology. Design: Prospective comparative analysis. Participants: Patients with dry eye, glaucoma, cataract, diabetic retinopathy (DR), age-related macular degeneration, and healthy individuals. Methods: The Vizzario Inc software development kit was integrated into 2 video game applications, Balloon Pop and Picture Perfect, which allowed for generation of VPI scores. Study participants were instructed to play rounds of each video game, from which a VPI score was compiled. Main Outcome Measures: The primary outcome was VPI overall score in each comparison group. Vision Performance Index component, subcomponent scores, and psychophysical inputs were also compared. Results: Vision Performance Index scores were generated from 93 patients with macular degeneration (n = 10), cataract (n = 10), DR (n = 15), dry eye (n = 15), glaucoma (n = 16), and no ocular disease (n = 27). The VPI overall score was not significantly different across comparison groups. The VPI subcomponent "reaction accuracy" score was significantly greater in DR patients (106 ± 13.2) versus controls (96.9 ± 11.5), P = 0.0220. The VPI subcomponent "color detection" score was significantly lower in patients with DR (96.8 ± 2.5; p=0.0217) and glaucoma (98.5 ± 6.3; P = 0.0093) compared with controls (101 ± 11). Psychophysical measures were statistically significantly different from controls: proportion correct (lower in DR, age-related macular degeneration), contrast errors (higher in cataract, DR), and saturation errors (higher in dry eye). Conclusions: Vision Performance Index scores can be generated from interactions of an ocular disease population with video games. The VPI may offer utility in monitoring select ocular diseases through evaluation of subcomponent and psychophysical input scores; however, future larger-scale studies must evaluate the validity of this tool. Financial Disclosures: Proprietary or commercial disclosure may be found after the references.

3.
Br J Ophthalmol ; 106(1): 65-70, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33011690

RESUMO

BACKGROUND/AIMS: The current study evaluates the efficacy and safety of the stand-alone implantation of the MINIject (iSTAR Medical, Wavre, Belgium) supraciliary, microinvasive glaucoma drainage device in patients with medically uncontrolled open-angle glaucoma. METHODS: This prospective, multicentre, first-in-human, single-arm interventional study evaluated stand-alone, ab interno implantation in 25 patients of a 5 mm long uveoscleral device made of STAR biocompatible material, which is a soft, microporous, flexible silicone. The primary outcome was the reduction of intraocular pressure (IOP) at 6 months compared with baseline, and follow-up continued until 2 years for 21 patients. Secondary outcomes included success defined as diurnal IOP of ≤21 mmHg and >5 mmHg with an IOP reduction of 20% without (complete) or with/without (qualified) glaucoma medication. RESULTS: Mean baseline IOP was 23.2±2.9 mmHg on 2.0±1.1 glaucoma medication ingredients and decreased to 13.8±3.5 mmHg (-40.7% reduction) on 1.0±1.3 medications 2 years after implantation. Complete success was achieved in 47.6% of patients (10/21) and qualified success in 100% of patients (21/21) at the 2-year follow-up. All patients achieved a 20% IOP reduction with 48% of patients medication-free. No serious ocular adverse events or additional glaucoma surgery were reported. Mean central endothelial cell density (ECD) mildly decreased from 2411 cells/mm2 (n=26) to 2341 cells/mm2 (n=21) at 24 months, which represents a 5% decrease for matched eyes. No patient had a ≥30% decrease in central ECD. CONCLUSION: This first-in-human study on the stand-alone implantation of the MINIject supraciliary drainage system shows promising IOP-lowering results and medication reduction over 24 months with few adverse events. TRIAL REGISTRATION NUMBER: NCT03193736.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto , Seguimentos , Glaucoma de Ângulo Aberto/tratamento farmacológico , Glaucoma de Ângulo Aberto/cirurgia , Humanos , Pressão Intraocular , Estudos Prospectivos , Tonometria Ocular , Resultado do Tratamento
4.
PLoS One ; 16(1): e0246104, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33507910

RESUMO

OBJECTIVE: Determine whether items in a cataract surgery appropriateness and prioritization questionnaire can predict change in best corrected visual acuity (BCVA) and health related quality of life (HRQOL) following cataract surgery. METHODS: 313 patients with a cataract in Ontario, Canada were recruited to participate. BCVA was measured using the Snellen chart. HRQOL was measured using a generic instrument (EQ5D), a visual functioning instrument (Catquest-9SF), and an appropriateness and prioritization instrument (17 items). Outcomes were measured preoperatively and 3-6 months postoperatively. Descriptive statistics were used to describe demographics and outcomes. For each appropriateness and prioritization questionnaire item, a one-way ANOVA was used to compare group means of the change in BCVA, EQ5D, and Catquest-9SF. RESULTS: Participants had a mean age of 69 years and were 56% female. BCVA improved in 81%, EQ5D in 49.6%, and Catquest-9SF score in 84% of patients. Improvement in both BCVA and Catquest-9SF scores were found in 68.5% of patients. The ANOVA showed a statistically significant association between a change in BCVA and the ability to participate in social life, and a statistically significant association between a change in Catquest-9SF and glare, extent of impairment in visual function, safety and injury concerns, ability to work and care for dependents, ability to take care of local errands, ability to assist others and ability to participate in social life. CONCLUSIONS: Almost all patients had improved BCVA and/or visual functioning after surgery. Seven variables from the cataract appropriateness and prioritization instrument were found to be predictors of improvement in Catquest-9SF measuring visual functioning.


Assuntos
Extração de Catarata , Catarata/fisiopatologia , Inquéritos e Questionários , Acuidade Visual , Adulto , Idoso , Idoso de 80 Anos ou mais , Catarata/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Ontário/epidemiologia , Estudos Prospectivos
5.
J Glaucoma ; 25(1): 106-12, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25304276

RESUMO

PURPOSE: To evaluate safety and clinical outcomes of a novel supraciliary device, the CyPass Micro-Stent, for surgical treatment of open-angle glaucoma when implanted in conjunction with cataract surgery. PATIENTS AND METHODS: Subjects (n=142) with open-angle glaucoma and cataract underwent combined phacoemulsification, with intraocular lens insertion, and microstent implantation into the supraciliary space of study eyes (n=167). Two analysis cohorts were prespecified based upon medicated baseline intraocular pressure (IOP): ≥21 mm Hg (cohort 1, n=65) or <21 mm Hg (cohort 2, n=102). Glaucoma medications were discontinued or tapered at surgery, and restarted at investigator discretion. The main postoperative outcome measures were adverse events, IOP changes, and number of IOP-lowering medications. RESULTS: Mean±SD follow-up was 294±121 days. No major intraoperative or postoperative complications occurred. Preoperative baseline mean IOP was 20.2±6.0 mm Hg and mean number of IOP-lowering medications was 2.0±1.1. Cohort 1 showed a 35% decrease in mean IOP and a 49% reduction in mean glaucoma medication usage; cohort 2 demonstrated a 75% reduction in mean medication usage while maintaining mean IOP<21 mm Hg. For all eyes, mean IOP at 12 months was 15.9±3.1 mm Hg (14% reduction from baseline). Early and late postoperative IOP elevation occurred in 1.2% and 1.8% of eyes, respectively. Two subjects developed mild transient hyphema, and none exhibited prolonged inflammation, persistent hypotony, or hypotony maculopathy. CONCLUSIONS: CyPass Micro-Stent implantation, combined with cataract surgery, resulted in minimal complications and reduced IOP and IOP-lowering medication use at 12 months postoperatively.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto/cirurgia , Facoemulsificação , Idoso , Idoso de 80 Anos ou mais , Catarata/complicações , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Tonometria Ocular , Resultado do Tratamento , Acuidade Visual/fisiologia
6.
J Ophthalmol ; 2012: 757106, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-21869921

RESUMO

Purpose. To describe the distribution of ocular variables, risk factors, and disease severity in newly diagnosed ocular hypertension (OH) or open-angle glaucoma (OAG). Methods. Eligible subjects underwent a complete history and examination. Adjusted odds ratios (ORs) and 95% confidence intervals (CIs) obtained from multiple logistic regression models were used to compare OAG to OH and advanced to early/moderate OAG. Results. 405 subjects were enrolled: 292 (72.1%) with OAG and 113 (27.9%) with OH. 51.7% had early, 27.1% moderate, and 20.9% advanced OAG. The OR for OAG versus OH was 8.19 (P < 0.0001) for disc notch, 5.36 (P < 0.0001) for abnormal visual field, 1.45 (P = 0.001) for worsening mean deviation, 1.91 (P < 0.0001) for increased cupping, 1.03 for increased age (P = 0.030), and 0.36 (P = 0.010) for smoking. Conclusions. Increased age was a risk for OAG, and smoking decreased the risk of OAG compared to OH. Almost half of the OAG subjects had moderate/advanced disease at diagnosis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...