Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 102
Filtrar
1.
JAMA ; 331(12): 1015-1024, 2024 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-38460161

RESUMO

Importance: Drug-coated balloons offer a potentially beneficial treatment strategy for the management of coronary in-stent restenosis. However, none have been previously evaluated or approved for use in coronary circulation in the United States. Objective: To evaluate whether a paclitaxel-coated balloon is superior to an uncoated balloon in patients with in-stent restenosis undergoing percutaneous coronary intervention. Design, Setting, and Participants: AGENT IDE, a multicenter randomized clinical trial, enrolled 600 patients with in-stent restenosis (lesion length <26 mm and reference vessel diameter >2.0 mm to ≤4.0 mm) at 40 centers across the United States between May 2021 and August 2022. One-year clinical follow-up was completed on October 2, 2023. Interventions: Participants were randomized in a 2:1 allocation to undergo treatment with a paclitaxel-coated (n = 406) or an uncoated (n = 194) balloon. Main Outcomes and Measures: The primary end point of 1-year target lesion failure-defined as the composite of ischemia-driven target lesion revascularization, target vessel-related myocardial infarction, or cardiac death-was tested for superiority. Results: Among 600 randomized patients (mean age, 68 years; 157 females [26.2%]; 42 Black [7%], 35 Hispanic [6%] individuals), 574 (95.7%) completed 1-year follow-up. The primary end point at 1 year occurred in 17.9% in the paclitaxel-coated balloon group vs 28.6% in the uncoated balloon group, meeting the criteria for superiority (hazard ratio [HR], 0.59 [95% CI, 0.42-0.84]; 2-sided P = .003). Target lesion revascularization (13.0% vs 24.7%; HR, 0.50 [95% CI, 0.34-0.74]; P = .001) and target vessel-related myocardial infarction (5.8% vs 11.1%; HR, 0.51 [95% CI, 0.28-0.92]; P = .02) occurred less frequently among patients treated with paclitaxel-coated balloon. The rate of cardiac death was 2.9% vs 1.6% (HR, 1.75 [95% CI, 0.49-6.28]; P = .38) in the coated vs uncoated balloon groups, respectively. Conclusions and Relevance: Among patients undergoing coronary angioplasty for in-stent restenosis, a paclitaxel-coated balloon was superior to an uncoated balloon with respect to the composite end point of target lesion failure. Paclitaxel-coated balloons are an effective treatment option for patients with coronary in-stent restenosis. Trial Registration: ClinicalTrials.gov Identifier: NCT04647253.


Assuntos
Reestenose Coronária , Infarto do Miocárdio , Feminino , Humanos , Idoso , Paclitaxel , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Stents , Resultado do Tratamento , Morte
2.
3.
Front Cardiovasc Med ; 10: 1112797, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37153472

RESUMO

Background: Class I echocardiographic guidelines in primary mitral regurgitation (PMR) risks left ventricular ejection fraction (LVEF) < 50% after mitral valve surgery even with pre-surgical LVEF > 60%. There are no models predicting LVEF < 50% after surgery in the complex interplay of increased preload and facilitated ejection in PMR using cardiac magnetic resonance (CMR). Objective: Use regression and machine learning models to identify a combination of CMR LV remodeling and function parameters that predict LVEF < 50% after mitral valve surgery. Methods: CMR with tissue tagging was performed in 51 pre-surgery PMR patients (median CMR LVEF 64%), 49 asymptomatic (median CMR LVEF 63%), and age-matched controls (median CMR LVEF 64%). To predict post-surgery LVEF < 50%, least absolute shrinkage and selection operator (LASSO), random forest (RF), extreme gradient boosting (XGBoost), and support vector machine (SVM) were developed and validated in pre-surgery PMR patients. Recursive feature elimination and LASSO reduced the number of features and model complexity. Data was split and tested 100 times and models were evaluated via stratified cross validation to avoid overfitting. The final RF model was tested in asymptomatic PMR patients to predict post-surgical LVEF < 50% if they had gone to mitral valve surgery. Results: Thirteen pre-surgery PMR had LVEF < 50% after mitral valve surgery. In addition to LVEF (P = 0.005) and LVESD (P = 0.13), LV sphericity index (P = 0.047) and LV mid systolic circumferential strain rate (P = 0.024) were predictors of post-surgery LVEF < 50%. Using these four parameters, logistic regression achieved 77.92% classification accuracy while RF improved the accuracy to 86.17%. This final RF model was applied to asymptomatic PMR and predicted 14 (28.57%) out of 49 would have post-surgery LVEF < 50% if they had mitral valve surgery. Conclusions: These preliminary findings call for a longitudinal study to determine whether LV sphericity index and circumferential strain rate, or other combination of parameters, accurately predict post-surgical LVEF in PMR.

4.
Eur Heart J Case Rep ; 7(2): ytac409, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36855601

RESUMO

Background: Over the past 2 years, the utilization of venovenous extracorporeal membrane oxygenation (VV-ECMO) for the treatment of coronavirus disease 2019 (COVID-19) acute respiratory distress syndrome (ARDS) has increased. While supporting respiratory function, VV-ECMO requires large-bore indwelling venous cannulas, which risk bleeding and infections, including endocarditis. Case summary: We describe two adults hospitalized for COVID-19 pneumonia who developed ARDS and right-ventricular failure, requiring VV-ECMO and ProtekDuo cannulation. After over 100 days with these devices, both patients developed tricuspid valve vegetations. Our first patient was decannulated from ECMO and discharged, but re-presented with a segmental pulmonary embolism and tricuspid mass. The Inari FlowTriver system was chosen to percutaneously remove both the tricuspid mass and pulmonary thromboembolism. Pathological examination of the mass demonstrated Candida albicans endocarditis in the setting of Candida fungemia. Our second patient developed a tricuspid valve vegetation which was also removed with the FlowTriever system. Pathological examination demonstrated endocarditis consistent with Pseudomonas aeruginosa in the setting of Pseudomonas bacteremia. Both patients experienced resolution of fungemia and bacteremia after percutaneous vegetation removal. After ECMO decannulation and percutaneous debulking, both patients experienced prolonged hospital stays for ventilator weaning and were eventually discharged with supplemental oxygen. Discussion: VV-ECMO and right-ventricular support devices are invasive and create various risks, including bloodstream infection and infective endocarditis. Percutaneous debulking of valvular vegetations associated with these right-sided indwelling devices may be an effective means of infection source control. It is unclear whether prolonged use of VV-ECMO provides a mortality benefit in COVID-19 ARDS.

5.
J Am Soc Echocardiogr ; 36(4): 381-390, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36610496

RESUMO

BACKGROUND: Transesophageal echocardiograms (TEEs) performed during transcatheter structural cardiac interventions may result in greater complications than those performed in the nonoperative setting or even those performed during cardiac surgery. However, there are limited data on complications associated with TEE during these procedures. We evaluated the prevalence of major complications among these patients in the United States. METHODS: A retrospective cohort study was conducted using an electronic health record database (TriNetX Research Network) from large academic medical centers across the United States for patients undergoing TEE during transcatheter structural interventions from January 2012 to January 2022. Using the American Society of Echocardiography-endorsed International Statistical Classification of Diseases and Related Health Problems Clinical Modifications (10th edition) codes, patients undergoing TEE during a transcatheter structural cardiac intervention, including transaortic, mitral or tricuspid valve repair, left atrial appendage occlusion, atrial septal defect closure, patent foramen ovale closure, and paravalvular leak repair, were identified. The primary outcome was major complications within 72 hours of the procedure (composite of bleeding and esophageal and upper respiratory tract injury). The secondary aim was the frequency of major complications, death, or cardiac arrest within 72 hours in patients who completed intraoperative TEE during surgical valve replacement. RESULTS: Among 12,043 adult patients (mean age, 74 years old; 42% female) undergoing TEE for transcatheter structural cardiac interventions, 429 (3.6%) patients had a major complication. Complication frequency was higher in patients on anticoagulation or antiplatelet therapy compared with those not on therapy (3.9% vs 0.5%; risk ratio [RR] = 8.09, P < .001). Compared with those patients <65 years of age, patients ≥65 years of age had a higher frequency of major complications (3.9% vs 2.2%; RR = 1.75, P < .001). Complication frequency was similar among male and female patients (3.5% vs 3.7%; RR = 0.96, P = .67). Among 28,848 patients who completed surgical valve replacement with TEE guidance, 728 (2.5%) experienced a major complication. CONCLUSIONS: This study found that more than 3% of patients undergoing TEE during transcatheter structural cardiac interventions have a major complication, which is more common among those on anticoagulant or antiplatelet therapy or who are elderly. With a shift of poor surgical candidates to less invasive percutaneous procedures, the future of TEE-guided procedures relies on comprehensive risk discussion and updating practices beyond conventional methods to minimize risk for TEE-related complications.


Assuntos
Ecocardiografia Transesofagiana , Comunicação Interatrial , Adulto , Humanos , Masculino , Feminino , Idoso , Ecocardiografia Transesofagiana/métodos , Estudos Retrospectivos , Inibidores da Agregação Plaquetária , Coração , Ecocardiografia/métodos , Comunicação Interatrial/cirurgia , Cateterismo Cardíaco/métodos , Resultado do Tratamento
6.
Ann Thorac Surg ; 115(2): e41-e44, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35305991

RESUMO

Management of rare ascending aortic complications after transcatheter aortic valve replacement (TAVR) remains a poorly defined area of knowledge. Furthermore, because most patients undergoing TAVR are at intermediate to high surgical risk, the treatment of such complications often requires endovascular approaches. Herein, we present a novel technique of endovascular ascending aorta stent graft delivery from the innominate artery for the treatment of a type A aortic dissection after self-expandable TAVR implantation, specifically addressing the landing of the aortic stent within the crown of the TAVR valve.


Assuntos
Estenose da Valva Aórtica , Dissecção da Aorta Ascendente , Procedimentos Endovasculares , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Aorta/cirurgia , Stents , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Valva Aórtica/cirurgia , Fatores de Risco
7.
JACC Case Rep ; 4(19): 1263-1266, 2022 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-36406909

RESUMO

Mechanical circulatory support devices are used to support the heart in cardiogenic shock. We present a case of demonstrating the feasible use of left ventricular assistive device with reverse configuration to support severe right ventricular failure in a patient with recent tricuspid annuloplasty ring.

8.
JACC Basic Transl Sci ; 7(10): 973-981, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36337921

RESUMO

Interstitial collagen loss and cardiomyocyte ultrastructural damage accounts for left ventricular (LV) sphericity and decrease in LV twist and circumferential strain. Normal LV diastolic function belies significantly abnormal left atrial (LA) function and early LV diastolic untwist rate. This underscores the complex interplay of LV and LA myocardial remodeling and function in the pathophysiology of primary mitral regurgitation. In this study, we connect LA function with LV systolic and diastolic myocardial remodeling and function using cardiac magnetic resonance tissue tagging in primary mitral regurgitation.

9.
J Cardiol Cases ; 25(2): 68-71, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35079300

RESUMO

Cor triatriatum dexter is an extremely rare congenital heart defect and cause of hypoxia in adults. We describe a case of cor triatriatum dexter discovered incidentally due to an iatrogenic atrial septal defect. The cor triatriatum dexter resolved with balloon dilation - a novel technique to manage this rare clinical condition. .

10.
Echocardiography ; 39(2): 339-370, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34997645

RESUMO

Extracorporeal membrane oxygenation (ECMO) provides advanced cardiopulmonary life support for patients in cardiac and/or respiratory failure. Echocardiography provides essential diagnostic and anatomic information prior to ECMO initiation, allows for safe and efficient ECMO cannula positioning, guides optimization of flow, provides a modality for rapid troubleshooting and patient evaluation, and facilitates decision-making for eventual weaning of ECMO support. Currently, guidelines for echocardiographic assessment in this clinical context are lacking. In this review, we provide an overview of echocardiographic considerations for advanced imagers involved in the care of these complex patients. We focus predominately on new cannulas and complex cannulation techniques, including a special focus on double lumen cannulas and a section discussing indirect left ventricular venting. Echocardiography is tremendously valuable in providing optimal care in these challenging clinical situations. It is imperative for imaging physicians to understand the pertinent anatomic considerations, the often complicated physiological and hemodynamic context, and the limitations of the imaging modality.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Respiratória , Cânula , Cateterismo/métodos , Ecocardiografia , Oxigenação por Membrana Extracorpórea/métodos , Humanos
11.
J Cardiothorac Vasc Anesth ; 36(6): 1709-1714, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-33836962

RESUMO

Herein the case of a patient with a prior history of heparin-induced thrombocytopenia who underwent percutaneous mitral valve edge-to-edge repair that was followed by a tricuspid edge-to-edge repair two months later is presented. Recommendations exist for systemic anticoagulant alternatives for percutaneous mitral valve edge-to-edge repair with the MitraClip device (Abbott, Chicago, IL), but minimal guidance and experience are present regarding alternative systemic anticoagulation during the performance of right-sided interventions, including tricuspid edge-to-edge repair (TriClip; Abbott). Notably, there is no clear consensus regarding the use of an alternative anticoagulant in the catheter flush solution for the delivery systems used during these procedures, particularly for right-sided interventions.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Trombocitopenia , Anticoagulantes/efeitos adversos , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Hirudinas , Humanos , Insuficiência da Valva Mitral/cirurgia , Fragmentos de Peptídeos , Proteínas Recombinantes , Trombocitopenia/induzido quimicamente , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia
12.
J Am Heart Assoc ; 10(16): e020491, 2021 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-34376060

RESUMO

Background Suprasternal access is an alternative access strategy for transcatheter aortic valve replacement (TAVR) where the innominate artery is cannulated from an incision above the sternal notch. To date, suprasternal access has never been compared with transfemoral TAVR. Thus, we sought to assess safety, feasibility, and early clinical outcomes between suprasternal and transfemoral access for patients undergoing TAVR. Methods and Results We evaluated patients from 2 institutional prospective, observational registries containing 1348 patients. Patients were selected in a 2:1 ratio (transfemoral:suprasternal) on the basis of propensity score matching. The primary outcome was in-hospital mortality, and secondary outcomes included the incidence of ischemic stroke, major bleeding, vascular injury, left bundle-branch block, and permanent pacemaker implantation at 30-day follow-up. Propensity score matching identified 89 patients undergoing suprasternal TAVR and 159 patients undergoing transfemoral TAVR suitable for analysis. There was no significant difference between suprasternal TAVR and transfemoral TAVR with respect to in-hospital mortality (1.1% versus 0.6%; odds ratio [OR], 1.80; 95% CI, 0.11-29.06; P=0.680). No patients in either cohort suffered an ischemic stroke. The incidence of major bleeding (2.2% versus 2.5%; OR, 0.89; 95% CI, 0.16-4.96; P=0.895) and vascular injury (1.1% versus 1.9%; OR, 0.59; 95% CI, 0.06-5.77; P=0.651) did not differ significantly. The frequency of left bundle-branch block (9.4% versus 15.8%; OR, 0.56; 95% CI, 0.24-1.30; P=0.177) and permanent pacemaker implantation (11.2% versus 5.9%; OR, 2.01; 95% CI, 0.75-5.45; P=0.169) were not statistically significantly different. Conclusions Suprasternal TAVR was safe and achieved promising short-term clinical outcomes when compared with transfemoral TAVR. Future studies seeking to identify the optimal alternative access site should evaluate suprasternal TAVR access alongside other substitutes for transfemoral TAVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Tronco Braquiocefálico , Cateterismo Periférico , Artéria Femoral , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Alabama , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Tronco Braquiocefálico/diagnóstico por imagem , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Estudos de Viabilidade , Feminino , Artéria Femoral/diagnóstico por imagem , Mortalidade Hospitalar , Humanos , Masculino , Cidade de Nova Iorque , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Pontuação de Propensão , Estudos Prospectivos , Punções , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
13.
Innovations (Phila) ; 16(5): 448-455, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34420410

RESUMO

OBJECTIVE: Percutaneous edge-to-edge mitral valve repair is an evolving procedure with increasing indications for use. The MitraClip™ G4 is the newest device with 4 device options, each with distinct characteristics. While the NTR and XTR clips have been in use, the G4 adds 2 new wider clips with additional features, the NTW and XTW. METHODS: We reviewed 26 cases employing the MitraClip G4 at our institution from November 2019 to March 2020. RESULTS: The NTR, XTR, NTW, and XTW clips were used in 3 (11.5%), 0 (0.0%), 16 (61.5%), and 11 (42.3%) cases, respectively. Median mitral regurgitation grade was reduced from 4+ to 1+, though 7 (27%) cases had 2+ residual mitral regurgitation. CONCLUSIONS: The new G4 device includes simplified instructions for use, the option of a wider clip, controlled gripper actuation, and potential left atrial pressure monitoring. The newest MitraClip G4 device allows for potential improved treatment options for patients with mitral regurgitation.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
14.
Am J Cardiol ; 148: 124-129, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33667448

RESUMO

The ECG findings during sudden collapse (syncope or sudden death) in severe aortic stenosis (AS) are not well defined. We conducted a comprehensive review of the literature for ECG data during sudden collapse in patients with AS and provided a case report of our own. There were 37 published cases of syncope or sudden death in patients with severe AS which were documented by ECG. Brady- or ventricular arrhythmias were documented in 34 cases (92%). Bradyarrhythmia (n = 24; 71%) was more common at the time of collapse than ventricular tachyarrhythmia (n = 10; 29%). There was slowing of the sinus rate before bradyarrhythmia in the vast majority of patients with bradyarrhythmia but not in those presenting with ventricular tachyarrhythmia (75% vs 0%; p <0.001). ECG evidence of ischemia (ST-segment depression or elevation) was present in most patients with bradyarrhythmia but not in those with ventricular tachyarrhythmia (75% vs 0%; p = 0.011). In conclusion, our findings suggest that left ventricular baroreceptor activation plays a dominant role in the pathophysiology of sudden collapse in patients with severe AS and suggest that ischemia may play a role as well.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Bradicardia/fisiopatologia , Morte Súbita Cardíaca , Isquemia Miocárdica/fisiopatologia , Síncope/fisiopatologia , Taquicardia Ventricular/fisiopatologia , Idoso , Estenose da Valva Aórtica/complicações , Doença da Válvula Aórtica Bicúspide/complicações , Bradicardia/etiologia , Eletrocardiografia , Ventrículos do Coração , Humanos , Masculino , Isquemia Miocárdica/etiologia , Pressorreceptores , Índice de Gravidade de Doença , Síncope/etiologia , Taquicardia Ventricular/etiologia
15.
Echocardiography ; 38(4): 693-696, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33749908

RESUMO

We describe an elderly male patient with two MitraClip devices, one fixed and the other detached, in whom live/real-time three-dimensional echocardiography (3DTEE) provided incremental value and additional information compared to two-dimensional transesophageal echocardiography (2DTEE). 3DTEE offered the ability to comprehensively assess the mitral valve (MV) utilizing full volume and multiplanar reconstruction (MPR) modes. 3DTEE proved useful in assessing the position of the properly attached and the partially detached MitraClip, including assessment of orifice size and degree of mitral regurgitation (MR). In addition, trapping of MV chordae by both clips was noted in the 3DTEE image dataset and confirmed at the time of surgery. Chordal trapping was not detected by 2DTEE. 3DTEE proved useful in more accurately estimating the severity of residual MR with the MitraClips in place since the regurgitant jet vena contracta (VC) could be viewed en face and VC area measured by planimetry in the correct imaging plane as compared to limited linear images from 2DTEE.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Idoso , Ecocardiografia Transesofagiana , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Reprodutibilidade dos Testes
16.
Echocardiography ; 38(3): 493-499, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33619808

RESUMO

A patient with heart failure due to nonischemic cardiomyopathy presented as a transfer to our institution following peripheral (femoral) venoarterial (VA) extracorporeal membrane oxygenation (ECMO) placement. With peripheral VA ECMO cannulation, the patient continued to have unstable ventricular tachyarrhythmias. Echocardiography demonstrated left ventricular (LV) dilation and severe mitral regurgitation (MR) with clinical and chest X-ray evidence of pulmonary edema. To provide venous drainage and simultaneous decompression of the left atrium (LA) and thereby indirect LV venting, a single multistage venous cannula was placed across the inter-atrial septum (IAS) using the previously described left atrial venoarterial (LA-VA) ECMO cannulation technique. Two- and three-dimensional (3D) transesophageal echocardiography (TEE) demonstrated utility in guiding cannula placement into the appropriate position and providing real time assessment of ventricular decompression and MR severity. There was subsequent improvement in pulmonary edema. This case is thought to be the first demonstration of real time resolution of pulmonary venous flow reversal in a patient undergoing LA-VA ECMO cannulation. This demonstration offers important mechanistic insight into some of the potential benefits of such an approach.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência da Valva Mitral , Pressão Atrial , Cânula , Cateterismo , Drenagem , Ecocardiografia Transesofagiana , Humanos , Insuficiência da Valva Mitral/cirurgia
17.
Ann Thorac Surg ; 112(1): e5-e8, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33422484

RESUMO

Endovascular stenting of the ascending aorta has been described for various aortic pathologies, including type A dissection in patients who are prohibitive risk for open surgery. Endovascular treatment of ascending aortic pathology poses unique anatomic and technical challenges related to aortic morphology. Herein, we present a novel technique of endovascular ascending stent graft delivery from a transfemoral approach for treatment of an acute type A dissection, utilizing a snare-guided deployment technique to facilitate favorable device deployment.


Assuntos
Aorta/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Prótese Vascular , Procedimentos Endovasculares/métodos , Doença Aguda , Idoso , Dissecção Aórtica/diagnóstico , Aorta/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico , Aortografia/métodos , Feminino , Humanos , Microcirurgia/métodos , Desenho de Prótese , Stents
19.
J Card Surg ; 35(12): 3631-3633, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33001516

RESUMO

Extracorporeal life support (ECLS) is an expanding technology for patients in cardiogenic shock. The majority of patients requiring ECLS can be managed with percutaneous venoarterial (VA) femoral cannulation. Despite sufficient extracorporeal circulatory support, a unclear number of patients develop left ventricular distension which can result in increased wall tension and stress as well as worsening pulmonary edema. Indications to vent the left ventricle can be controversial. When venting is indicated, a number of additional procedures may be considered including inotropic support, intra-aortic balloon pump, impella, balloon atrial septostomy, or placement of a transseptal cannula. We present a unique case of a femoral VA extracorporeal membrane oxygenation as a bridge to transplant with left-sided venting using a Bio-Medicus NextGen cannula (Medtronic) with a transseptal approach.


Assuntos
Oxigenação por Membrana Extracorpórea , Cânula , Drenagem , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Choque Cardiogênico/terapia
20.
Echocardiography ; 37(11): 1860-1863, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33007127

RESUMO

A patient with heart failure due to dilated ischemic cardiomyopathy presented in cardiogenic shock for institution of veno-arterial extracorporeal membrane oxygenation as a bridge to cardiac transplantation. To provide adequate venous drainage and simultaneous decompression of the left atrium (indirect left ventricular venting), a single venous cannula was placed across the interatrial septum so that the distal orifice and side ports were located within the left atrium and the proximal set of side ports were positioned at the cavoatrial junction. Three-dimensional transesophageal echocardiography demonstrated utility in guiding cannula placement and appropriate positioning within the left atrium.


Assuntos
Oxigenação por Membrana Extracorpórea , Cânula , Drenagem , Ecocardiografia Transesofagiana , Humanos , Choque Cardiogênico/diagnóstico por imagem , Choque Cardiogênico/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...