Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Med Surg (Lond) ; 86(1): 433-438, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38222729

RESUMO

In May 2019, the U.S. Food and Drug Administration approved tafamidis as the first conservative management of transthyretin amyloid cardiomyopathy (ATTR-CM). Our aim in conducting this systematic review and meta-analysis was to assess the efficacy of tafamidis on patients with ATTR-CM. For that purpose, we thoroughly searched PubMed, ScienceDirect, and Clinical trails.gov by using the appropriate search strategy and following predefined inclusion and exclusion criteria, which retrieved 235 articles initially. Of which two randomized controlled trials (RCTs) and one observational study matched our inclusion criteria. A total of 876 patients are included in this analysis. Based on results, tafamidis significantly reduced cardiovascular (CV) mortality in the ATTR-ACT trial and Ochi et al. (OR 0.58; 95% CI: [0.41-0.83], P=0.003, I 2=87%). A subgroup analysis was conducted for CV mortality due to heart failure (OR 0.89; 95% CI: [0.63-1.25], P=0.50, I 2=93%). The results exhibit that tafamidis reduced all causes of mortality (OR 0.45; 95% CI: [0.32-0.64], P≤0.00001, I 2=22%). Furthermore, mortality remained statistically insignificant in patients with heart transplants (OR 1.18; 95% CI: [0.52-2.70], P=0.70, I 2=0%) and patients with cardiac mechanical assist devices (OR 4.15; 95% CI: [0.48-35.66], P=0.20, I 2=0%). This meta-analysis suggests that tafamidis is a safe and efficient drug to use in patients with ATTR-CM and can possess the potential to be a milestone in enhancing the conservative management of the patients.

2.
Biomed Res Int ; 2021: 3194433, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34532499

RESUMO

OBJECTIVE: Analyzing and comparing the fit and accuracy of removable partial denture (RPDs) frameworks fabricated with CAD/CAM and rapid prototyping methods with conventional techniques. MATERIALS AND METHODS: The present systematic review was carried out according to PRISMA guidelines. The search was carried out on PubMed/MEDLINE, Cochrane collaboration, Science direct, and Scopus scientific engines using selected MeSH keywords. The articles fulfilling the predefined selection criteria based on the fit and accuracy of removable partial denture (RPD) frameworks constructed from digital workflow (CAD/CAM; rapid prototyping) and conventional techniques were included. RESULTS: Nine full-text articles comprising 6 in vitro and 3 in vivo studies were included in this review. The digital RPDs were fabricated in all articles by CAD/CAM selective laser sintering and selective laser melting techniques. The articles that have used CAD/CAM and rapid prototyping technique demonstrated better fit and accuracy as compared to the RPDs fabricated through conventional techniques. The least gaps between the framework and cast (41.677 ± 15.546 µm) were found in RPDs constructed through digital CAD/CAM systems. CONCLUSION: A better accuracy was achieved using CAD/CAM and rapid prototyping techniques. The RPD frameworks fabricated by CAD/CAM and rapid prototyping techniques had clinically acceptable fit, superior precision, and better accuracy than conventionally fabricated RPD frameworks.


Assuntos
Planejamento de Dentadura/métodos , Planejamento de Dentadura/tendências , Prótese Parcial Removível/tendências , Desenho Assistido por Computador/tendências , Prótese Parcial/tendências , Humanos , Lasers , Fluxo de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...