Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Chem Res Toxicol ; 37(2): 220-226, 2024 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-38235526

RESUMO

We measured levels of nitrosonornicotine (NNN) and 4-[methyl(nitroso)amino]-1-(3-pyridinyl)-1-butanone (NNK), the two most carcinogenic tobacco-specific nitrosamines, in the filler, binder, and wrapper of 50 cigars: 19 large cigars, 23 cigarillos, and 8 little cigars. The average NNN and NNK levels were 10.6 and 3.70 µg/g, respectively. These levels are 5- and 7-fold higher, respectively, than those of commercial cigarettes. The differences in NNN and NNK levels between cigars and cigarettes reflect differences in tobacco blends and tobacco treatments, such as fermentation. The average tobacco NNN and NNK levels of large cigars were 3- and 5-fold higher than those of cigarillos and little cigars, respectively. Large cigars also exhibited a significantly broader range of NNN and NNK than cigarillos and little cigars. The NNN and NNK levels in cigarillos are comparable to those of little cigars. These results are consistent with earlier studies finding that cigarillos and little cigars have similar tobacco blends with lower NNN and NNK content than large cigar tobacco blends.


Assuntos
Nitrosaminas , Produtos do Tabaco , Carcinógenos/análise
2.
Materials (Basel) ; 16(17)2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37687716

RESUMO

As a transfer member at the discontinuous place of vertical load, the deep beam has a complex stress mechanism and many influencing factors, such as compressive strength of concrete, shear span ratio, and reinforcement ratio. At the same time, the stress analysis principle of traditional shallow beams is no longer applicable to the design and calculation of deep-beam structure. The main purpose of this paper was to use the strut-and-tie model to analyze its stress mechanism, and to verify the applicability of the model. Nine high-strength concrete deep-beam specimens with longitudinal reinforcement with an anchor plate of the same size were tested by two-point concentrated loading method. The effects of shear span ratio (0.3, 0.6, and 0.9), longitudinal reinforcement ratio (0.67%, 1.05%, and 1.25%), horizontal reinforcement ratio (0.33%, 0.45%, and 0.50%), and stirrup reinforcement ratio (0.25%, 0.33%, and 0.50%) on the failure mode, deflection curve, characteristic load, crack width, steel bar, and concrete strain of the specimens were analyzed. The results showed that the failure mode of deep-beam specimens was diagonal compression failure. The normal section cracking load was about 15 to 20% of the ultimate load, and the inclined section cracking load was about 30~40% of the ultimate load. The shear span ratio increased from 0.3 to 0.9, and the bearing capacity decreased by 32.9%. When the longitudinal reinforcement ratio increased from 0.67% to 1.25%, the ultimate load increased by 42.6%. The shear span ratio and longitudinal reinforcement ratio have a significant effect on the bearing capacity of the high-strength concrete deep beams with longitudinal reinforcement with an anchor plate. The shear capacity of nine high-strength concrete deep-beam specimens with longitudinal reinforcement with an anchor plate was calculated by national standards, and the results were compared with the calculation results of the Tan-Tang model, the Tan-Cheng model, SSTM, and SSSTM. The analysis showed that the softened strut-and-tie model takes into account the softening effect of compressive concrete, and is a more accurate mechanical model, which can be applied to predict the shear capacity of high-strength concrete deep-beam members with longitudinal reinforcement with an anchor plate.

3.
Materials (Basel) ; 16(14)2023 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-37512182

RESUMO

According to the shear capacity test results of six steel-fiber-reinforced high-strength concrete (SFHSC) corbels with welded-anchorage longitudinal reinforcement under concentrated load, the effects of shear span ratio and steel fiber volume fraction on the failure mode, cracking load and ultimate load of corbel specimens were analyzed. On the basis of experimental research, the shear transfer mechanism of corbel structure was discussed. Then, a modified softened strut-and-tie model (MSSTM), composed of the diagonal and horizontal mechanisms, was proposed, for steel-fiber-reinforced high-strength concrete corbels. The contributions of concrete, steel fiber and horizontal stirrups to the shear bearing capacity of the corbels were clarified. A calculation method for the shear bearing capacity of steel-fiber-reinforced high-strength concrete corbels was established and was simplified on this basis. The calculation results of the model were compared with the test values and calculation results of the GB50010-2010 code, the ACI318-19 code, the EN 1992-1-1 code and the CSA A23.3-19 code. The results showed that the concrete corbel with small shear span ratio mainly has two typical failure modes: shear failure and diagonal compression failure. With the increase in shear span ratio, the shear capacity of corbels decreases. Steel fiber can improve the ductility of a reinforced concrete corbel, but has little effect on the failure mode of the diagonal section. The calculated values of the national codes were lower than the experimental values, and the results were conservative. The theoretical calculation values of the shear capacity calculation model of the corbels were close to the experimental results. In addition, the model has a clear mechanical concept considering the tensile properties of steel-fiber-reinforced high-strength concrete and the influence of horizontal stirrups, which can reasonably reflect the shear transfer mechanism of corbels.

4.
Materials (Basel) ; 16(8)2023 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-37109891

RESUMO

As short cantilever members, corbels are mainly used to transfer eccentric loads to columns. Because of the discontinuity of load and geometric structure, corbels cannot be analyzed and designed using the method based on beam theory. Nine steel-fiber-reinforced high-strength concrete (SFRHSC) corbels were tested. The width of the corbels was 200 mm, the cross-section height of the corbel column was 450 mm, and the cantilever end height was 200 mm. The shear span/depth ratios considered were 0.2, 0.3, and 0.4; the longitudinal reinforcement ratios were 0.55%, 0.75%, and 0.98%; the stirrup reinforcement ratios were 0.39%, 0.52%, and 0.785%; and the steel fiber volume ratios were 0, 0.75%, and 1.5%. According to the test results, this paper discusses the failure process and failure mode of corbel specimens with a small shear span/depth ratio and analyzes the effects of variables such as shear span/depth ratio, longitudinal reinforcement ratio, stirrup reinforcement ratio, and steel fiber volume content on the shear capacity of corbels. The shear capacity of corbels is significantly affected by the shear span/depth ratio, followed by the longitudinal reinforcement ratio and the stirrup reinforcement ratio. Moreover, it is shown that steel fibers have little impact on the failure mode and ultimate load of corbels, but can enhance the crack resistance of corbels. In addition, the bearing capacities of these corbels were calculated by Chinese code GB 50010-2010 and further compared with ACI 318-19 code, EN 1992-1-1:2004 code, and CSA A23.3-19 code, which adopt the strut-and-tie model. The results indicate that the calculation results by the empirical formula in the Chinese code are close to the corresponding test results, while the calculation method based on the strut-and-tie model of a clear mechanical concept yields conservative results, and hence the related parameter values must be further modified.

5.
Nicotine Tob Res ; 25(6): 1202-1206, 2023 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-36702747

RESUMO

INTRODUCTION: Studies have evaluated the role of menthol cigarettes on various addiction-related outcomes; however, the effect of varying menthol content on these outcomes has not been evaluated. We developed a method to amend non-menthol SPECTRUM Research Cigarettes to contain menthol at four different levels. AIMS AND METHODS: SPECTRUM Research Cigarettes, NRC 600 (0.8 mg nicotine; 10 mg tar), were modified to contain target menthol amounts at 3, 6, and 12 mg/cigarette by injecting 25 µL ethanol/triacetin/menthol solutions of varying concentrations (120 mg menthol/mL, 240 mg/mL, and 480 mg/mL) into four distinct locations in the filter and tobacco rod. Menthol content was tested in triplicate in the whole cigarette and in the tobacco rod and filter at 1, 24, 48, and 72 hours for each target menthol level using an extraction solution of quinoline in methyl-tert-butyl ether and measured using gas chromatography with flame ionization detection. RESULTS: Injections into the filter and tobacco rod (12.5 µL each) yielded equal menthol distribution up to 72 hours. However, total menthol content decreased from an average of 90.3% of the target menthol concentration at 1 hour to 80.7% at 72 hours in cigarettes stored individually in glass tubes at room temperature. Analysis of urinary menthol glucuronide confirmed that amended cigarettes used within 24 hours of injection delivered dose-related menthol levels to participants in a clinical laboratory setting. CONCLUSION: This method can be used to modify cigarettes with a range of reliable menthol levels in both filter and tobacco rod for use in laboratory and clinical research. IMPLICATIONS: This study presents a technique for modifying cigarettes with different levels of menthol that can reliably deliver dose-related menthol levels to participants when smoked in a clinical study. The technique can be used to quickly amend cigarettes to examine the independent effects of varying flavor and additive levels on smoking behavior, nicotine pharmacokinetics, mainstream smoke emissions, and other laboratory or clinical research outcomes.


Assuntos
Nicotina , Produtos do Tabaco , Humanos , Nicotina/análise , Produtos do Tabaco/análise , Fumar , Nicotiana , Fumaça/análise
6.
Chem Res Toxicol ; 35(6): 940-953, 2022 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-35612471

RESUMO

Mainstream smoke yields of hydrogen cyanide (HCN) and three aromatic amines, 1-aminonaphthalene, 2-aminonaphthalene, and 4-aminobiphenyl, from 60 little cigar brands currently on the US market were measured for both International Organization for Standardization (ISO) and Canadian Intense (CI) smoking regimens. The smoke yields are compared with those from 50 cigarette products measured by Counts et al. of Philip Morris USA (PMUSA) in 2005 [Counts et al. Regul. Toxicol. Pharmacol. 2005 41, 185-227] and 50 cigarette products measured by the Centers for Disease Control and Prevention (CDC) in cooperation with the Food and Drug Administration (FDA) in 2012 [Tynan et al. Consumption of Cigarettes and Combustible Tobacco: United States, 2000-2011. In Morbidity and Mortality Weekly Report; Centers for Disease Control and Prevention, 2012; 565-580]. For the little cigars, the average HCN yield with the ISO smoking regimen is 335 µg/cigar (range: 77-809 µg/cigar), which is 332% higher than the average of 50 PMUSA 2005 cigarettes and 243% higher than the average of 50 CDC/FDA 2012 cigarettes. For the CI smoking regimen, the average HCN yield is 619 µg/cigar (range: 464-1045 µg/cigar), which is 70.5% higher than the average of 50 PMUSA 2005 cigarettes and 69% higher than the average of the 50 CDC/FDA 2012 cigarettes. For aromatic amines, the average ISO smoking regimen smoke yields are 36.6 ng/cigar (range: 15.9-70.6 ng/cigar) for 1-aminonaphthalene, 24.6 ng/cigar (range: 12.3-36.7 ng/cigar) for 2-aminonaphthalene, and 5.6 ng/cigar (range: 2.3-17.2 ng/cigar) for 4-aminobiphenyl. The average ISO yields of aromatic amines from little cigars are 141% to 210% higher compared to the average yields of 50 PMUSA cigarettes. The average CI smoke regimen yields are 73.0 ng/cigar (range: 32.1-112.2 ng/cigar) for 1-aminonaphthalene, 45.2 ng/cigar (range: 24.6-74.8 ng/cigar) for 2-aminonaphthalene, and 12.7 ng/cigar (range: 5.5-37.5 ng/cigar) for 4-aminobiphenyl. The average CI aromatic amine yields are 143% to 220% higher compared to the average yields of 50 PMUSA cigarettes, almost identical to the relative yields under the ISO smoking regimen. Both HCN and aromatic amine yields are 1.5× to 3× higher for the tested little cigars than for the conventional cigarettes; however, there are notable differences in the relationships of these yields to certain product characteristics, such as weight, ventilation, and tobacco type. The higher smoke yields of these compounds from little cigars indicates that cigar smokers may be at risk of a higher exposure to HCN and aromatic amines on a per stick basis and thus increased health concerns.


Assuntos
Fumaça , Produtos do Tabaco , 1-Naftilamina , 2-Naftilamina , Aminas , Canadá , Cianeto de Hidrogênio , Fumaça/análise , Nicotiana , Estados Unidos
8.
Nicotine Tob Res ; 18(7): 1575-80, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26259988

RESUMO

INTRODUCTION: In 2011 menthol cigarettes accounted for 32 percent of the market in the United States, but there are few literature reports that provide measured menthol data for commercial cigarettes. To assess current menthol application levels in the US cigarette market, menthol levels in cigarettes labeled or not labeled to contain menthol was determined for a variety of contemporary domestic cigarette products. METHOD: We measured the menthol content of 45 whole cigarettes using a validated gas chromatography/mass spectrometry method. RESULTS: In 23 cigarette brands labeled as menthol products, the menthol levels of the whole cigarette ranged from 2.9 to 19.6mg/cigarette, with three products having higher levels of menthol relative to the other menthol products. The menthol levels for 22 cigarette products not labeled to contain menthol ranged from 0.002 to 0.07mg/cigarette. The type of packaging (soft vs. hard pack) for a given cigarette product does not appear to affect menthol levels based on the current limited data. CONCLUSIONS: Menthol levels in cigarette products labeled as containing menthol are approximately 50- to 5000-fold higher than those in cigarette products not labeled as containing menthol. In general, menthol content appears to occur within discrete ranges for both mentholated and nonmentholated cigarettes. IMPLICATIONS: This study shows that menthol may be present in non-mentholated cigarettes and adds to the understanding of how menthol may be used in cigarette products. It is the first systematic study from the same laboratory which will readily enable comparison among menthol and non-menthol cigarettes.


Assuntos
Aromatizantes/análise , Marketing , Mentol/análise , Embalagem de Produtos , Produtos do Tabaco/análise , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Indústria do Tabaco/normas , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...