Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Int J Radiat Biol ; : 1-13, 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38190433

RESUMO

PURPOSE: The purpose of this paper is to provide an overview of the methodology used to estimate radiation genetic risks and quantify the risk of hereditary effects as outlined in the ICRP Publication 103. It aims to highlight the historical background and development of the doubling dose method for estimating radiation-related genetic risks and its continued use in radiological protection frameworks. RESULTS: This article emphasizes the complexity associated with quantifying the risk of hereditary effects caused by radiation exposure and highlights the need for further clarification and explanation of the calculation method. As scientific knowledge in radiation sciences and human genetics continues to advance in relation to a number of factors including stability of disease frequency, selection pressures, and epigenetic changes, the characterization and quantification of genetic effects still remains a major issue for the radiological protection system of the International Commission on Radiological Protection. CONCLUSION: Further research and advancements in this field are crucial for enhancing our understanding and addressing the complexities involved in assessing and managing the risks associated with hereditary effects of radiation.

2.
Int J Radiat Biol ; : 1-11, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37947483

RESUMO

PURPOSE: Over the last decade or so, ethical and societal aspects of radiological protection have received increasing attention. This is also reflected in the publications of the International Commission on Radiological Protection (ICRP). The current paper aims at identifying relevant ethical and societal topics which should receive attention in the context of radiological protection for offspring and next generations. MATERIALS AND METHODS: We present a non-comprehensive review of the subject, based on presentation made at an ICRP workshop in Budapest in 2022. We first discuss the ethical values promoted by ICRP, and the application of these values in cases of (potential) pre-conceptual and prenatal radiation exposures. We then consider experience gained after the Fukushima accident indicating particular societal concerns about the health effects of such exposures. RESULTS AND CONCLUSIONS: Beneficence/non-maleficence, prudence, justice and dignity, the "core values" of the system of radiological protection have special roles to play when heritable and/or in utero effects are to be considered. Prudence, in particular, must be taken account of in view of the fact that solid scientific data in humans are largely lacking in this area, and it is necessary to rely on insights from animal experiments as well as theoretical considerations. As regards societal considerations, the perception of risk among (potentially) affected populations needs to be taken seriously. Accountability, transparency, and inclusivity, the "procedural values" promoted by ICRP for the practical implementation of the system of radiological protection play a central role in overcoming skepticism and creating trust. Stakeholder involvement should emphasize cooperation and dialogue, which allows for the joint evaluation of an exposure situation by experts and affected people.

3.
Radiat Res ; 199(6): 556-570, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37018160

RESUMO

After large-scale radiation accidents where many individuals are suspected to be exposed to ionizing radiation, biological and physical retrospective dosimetry assays are important tools to aid clinical decision making by categorizing individuals into unexposed/minimally, moderately or highly exposed groups. Quality-controlled inter-laboratory comparisons of simulated accident scenarios are regularly performed in the frame of the European legal association RENEB (Running the European Network of Biological and Physical retrospective Dosimetry) to optimize international networking and emergency readiness in case of large-scale radiation events. In total 33 laboratories from 22 countries around the world participated in the current RENEB inter-laboratory comparison 2021 for the dicentric chromosome assay. Blood was irradiated in vitro with X rays (240 kVp, 13 mA, ∼75 keV, 1 Gy/min) to simulate an acute, homogeneous whole-body exposure. Three blood samples (no. 1: 0 Gy, no. 2: 1.2 Gy, no. 3: 3.5 Gy) were sent to each participant and the task was to culture samples, to prepare slides and to assess radiation doses based on the observed dicentric yields from 50 manually or 150 semi-automatically scored metaphases (triage mode scoring). Approximately two-thirds of the participants applied calibration curves from irradiations with γ rays and about 1/3 from irradiations with X rays with varying energies. The categorization of the samples in clinically relevant groups corresponding to individuals that were unexposed/minimally (0-1 Gy), moderately (1-2 Gy) or highly exposed (>2 Gy) was successfully performed by all participants for sample no. 1 and no. 3 and by ≥74% for sample no. 2. However, while most participants estimated a dose of exactly 0 Gy for the sham-irradiated sample, the precise dose estimates of the samples irradiated with doses >0 Gy were systematically higher than the corresponding reference doses and showed a median deviation of 0.5 Gy (sample no. 2) and 0.95 Gy (sample no. 3) for manual scoring. By converting doses estimated based on γ-ray calibration curves to X-ray doses of a comparable mean photon energy as used in this exercise, the median deviation decreased to 0.27 Gy (sample no. 2) and 0.6 Gy (sample no. 3). The main aim of biological dosimetry in the case of a large-scale event is the categorization of individuals into clinically relevant groups, to aid clinical decision making. This task was successfully performed by all participants for the 0 Gy and 3.5 Gy samples and by 74% (manual scoring) and 80% (semiautomatic scoring) for the 1.2 Gy sample. Due to the accuracy of the dicentric chromosome assay and the high number of participating laboratories, a systematic shift of the dose estimates could be revealed. Differences in radiation quality (X ray vs. γ ray) between the test samples and the applied dose effect curves can partly explain the systematic shift. There might be several additional reasons for the observed bias (e.g., donor effects, transport, experimental conditions or the irradiation setup) and the analysis of these reasons provides great opportunities for future research. The participation of laboratories from countries around the world gave the opportunity to compare the results on an international level.


Assuntos
Aberrações Cromossômicas , Liberação Nociva de Radioativos , Humanos , Estudos Retrospectivos , Radiometria/métodos , Bioensaio/métodos , Cromossomos , Relação Dose-Resposta à Radiação
4.
Radiat Res ; 197(1): 36-42, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33652474

RESUMO

Epidemiological studies suggest an increased incidence and risk of cataract after low-dose (<2 Gy) ionizing radiation exposures. However, the biological mechanism(s) of this process are not fully understood. DNA damage and repair are thought to have a contributing role in radiation-induced cataractogenesis. Recently we have reported an inverse dose-rate effect, as well as the low-dose response, of DNA damage and repair in lens epithelial cells (LECs). Here, we present further initial findings from two mutated strains (Ercc2+/- and Ptch1+/-) of mice, both reportedly susceptible to radiation-induced cataract, and their DNA damage and repair response to low-dose and low-dose-rate gamma rays. Our results support the hypothesis that the lens epithelium responds differently to radiation than other tissues, with reported radiation susceptibility to DNA damage not necessarily translating to the LECs. Genetic predisposition and strain(s) of mice have a significant role in radiation-induced cataract susceptibility.


Assuntos
Catarata/etiologia , Dano ao DNA/efeitos da radiação , Cristalino/efeitos dos fármacos , Animais , Células Epiteliais , Raios gama , Humanos , Camundongos , Receptor Patched-1/metabolismo , Exposição à Radiação , Proteína Grupo D do Xeroderma Pigmentoso/metabolismo
5.
Radiat Res ; 197(1): 92-99, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33984857

RESUMO

Lens epithelial cell proliferation and differentiation are naturally well regulated and controlled, a characteristic essential for lens structure, symmetry and function. The effect of ionizing radiation on lens epithelial cell proliferation has been demonstrated in previous studies at high acute doses, but the effect of dose and dose rate on proliferation has not yet been considered. In this work, mice received single acute doses of 0.5, 1 and 2 Gy of radiation, at dose rates of 0.063 and 0.3 Gy/min. Eye lenses were isolated postirradiation at 30 min up until 14 days and flat-mounted. Then, cell proliferation rates were determined using biomarker Ki67. As expected, radiation increased cell proliferation 2 and 24 h postirradiation transiently (undetectable 14 days postirradiation) and was dose dependent (changes were very significant at 2 Gy; P = 0.008). A dose-rate effect did not reach significance in this study (P = 0.054). However, dose rate and lens epithelial cell region showed significant interactions (P < 0.001). These observations further our mechanistic understanding of how the lens responds to radiation.


Assuntos
Cristalino/efeitos da radiação , Animais , Diferenciação Celular/efeitos da radiação , Proliferação de Células/efeitos da radiação , Relação Dose-Resposta à Radiação , Células Epiteliais , Feminino , Humanos , Camundongos Endogâmicos C57BL , Doses de Radiação , Exposição à Radiação , Radiação Ionizante
6.
Radiat Res ; 197(1): 57-66, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33984859

RESUMO

Recent epidemiological findings and reanalysis of historical data suggest lens opacities resulting from ionizing radiation exposures are likely induced at lower doses than previously thought. These observations have led to ICRP recommendations for a reduction in the occupational dose limits for the eye lens, as well as subsequent implementation in EU member states. The EU CONCERT LDLensRad project was initiated to further understand the effects of ionizing radiation on the lens and identify the mechanism(s) involved in radiation-induced cataract, as well as the impact of dose and dose-rate. Here, we present the results of a long-term study of changes to lens opacity in male and female adult mice from a variety of different genetic (radiosensitive or radioresistant) backgrounds, including mutant strains Ercc2 and Ptch1, which were assumed to be susceptible to radiation-induced lens opacities. Mice received 0.5, 1 and 2 Gy 60Co gamma-ray irradiation at dose rates of 0.063 and 0.3 Gy min-1. Scheimpflug imaging was used to quantify lens opacification as an early indicator of cataract, with monthly observations taken postirradiation for an 18-month period in all strains apart from 129S2, which were observed for 12 months. Opacification of the lens was found to increase with time postirradiation (with age) for most mouse models, with ionizing radiation exposure increasing opacities further. Sex, dose, dose rate and genetic background were all found to be significant contributors to opacification; however, significant interactions were identified, which meant that the impact of these factors was strain dependent. Mean lens density increased with higher dose and dose rate in the presence of Ercc2 and Ptch1 mutations. This project was the first to focus on low (<1 Gy) dose, multiple dose rate, sex and strain effects in lens opacification, and clearly demonstrates the importance of these experimental factors in radiobiological investigations on the lens. The results provide insight into the effects of ionizing radiation on the lens as well as the need for further work in this area to underpin appropriate radiation protection legislation and guidance.


Assuntos
Catarata/etiologia , Animais , Feminino , Patrimônio Genético , Humanos , Cristalino/efeitos da radiação , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Exposição Ocupacional , Receptor Patched-1/metabolismo , Doses de Radiação , Exposição à Radiação , Radiação Ionizante , Proteína Grupo D do Xeroderma Pigmentoso/metabolismo
7.
Radiat Prot Dosimetry ; 194(1): 42-56, 2021 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-33989429

RESUMO

Since 2012, the European Radiation Dosimetry Group (EURADOS) has developed its Strategic Research Agenda (SRA), which contributes to the identification of future research needs in radiation dosimetry in Europe. Continued scientific developments in this field necessitate regular updates and, consequently, this paper summarises the latest revision of the SRA, with input regarding the state of the art and vision for the future contributed by EURADOS Working Groups and through a stakeholder workshop. Five visions define key issues in dosimetry research that are considered important over at least the next decade. They include scientific objectives and developments in (i) updated fundamental dose concepts and quantities, (ii) improved radiation risk estimates deduced from epidemiological cohorts, (iii) efficient dose assessment for radiological emergencies, (iv) integrated personalised dosimetry in medical applications and (v) improved radiation protection of workers and the public. This SRA will be used as a guideline for future activities of EURADOS Working Groups but can also be used as guidance for research in radiation dosimetry by the wider community. It will also be used as input for a general European research roadmap for radiation protection, following similar previous contributions to the European Joint Programme for the Integration of Radiation Protection Research, under the Horizon 2020 programme (CONCERT). The full version of the SRA is available as a EURADOS report (www.eurados.org).


Assuntos
Monitoramento de Radiação , Proteção Radiológica , Europa (Continente) , Humanos , Doses de Radiação , Radiação Ionizante , Radiometria
8.
Sci Rep ; 11(1): 9756, 2021 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-33963206

RESUMO

Large-scale radiation emergency scenarios involving protracted low dose rate radiation exposure (e.g. a hidden radioactive source in a train) necessitate the development of high throughput methods for providing rapid individual dose estimates. During the RENEB (Running the European Network of Biodosimetry) 2019 exercise, four EDTA-blood samples were exposed to an Iridium-192 source (1.36 TBq, Tech-Ops 880 Sentinal) at varying distances and geometries. This resulted in protracted doses ranging between 0.2 and 2.4 Gy using dose rates of 1.5-40 mGy/min and exposure times of 1 or 2.5 h. Blood samples were exposed in thermo bottles that maintained temperatures between 39 and 27.7 °C. After exposure, EDTA-blood samples were transferred into PAXGene tubes to preserve RNA. RNA was isolated in one laboratory and aliquots of four blinded RNA were sent to another five teams for dose estimation based on gene expression changes. Using an X-ray machine, samples for two calibration curves (first: constant dose rate of 8.3 mGy/min and 0.5-8 h varying exposure times; second: varying dose rates of 0.5-8.3 mGy/min and 4 h exposure time) were generated for distribution. Assays were run in each laboratory according to locally established protocols using either a microarray platform (one team) or quantitative real-time PCR (qRT-PCR, five teams). The qRT-PCR measurements were highly reproducible with coefficient of variation below 15% in ≥ 75% of measurements resulting in reported dose estimates ranging between 0 and 0.5 Gy in all samples and in all laboratories. Up to twofold reductions in RNA copy numbers per degree Celsius relative to 37 °C were observed. However, when irradiating independent samples equivalent to the blinded samples but increasing the combined exposure and incubation time to 4 h at 37 °C, expected gene expression changes corresponding to the absorbed doses were observed. Clearly, time and an optimal temperature of 37 °C must be allowed for the biological response to manifest as gene expression changes prior to running the gene expression assay. In conclusion, dose reconstructions based on gene expression measurements are highly reproducible across different techniques, protocols and laboratories. Even a radiation dose of 0.25 Gy protracted over 4 h (1 mGy/min) can be identified. These results demonstrate the importance of the incubation conditions and time span between radiation exposure and measurements of gene expression changes when using this method in a field exercise or real emergency situation.


Assuntos
Células Sanguíneas/metabolismo , Raios gama/efeitos adversos , Regulação da Expressão Gênica/efeitos da radiação , Laboratórios , Doses de Radiação , Exposição à Radiação , Raios X/efeitos adversos , Relação Dose-Resposta à Radiação , Humanos , Reprodutibilidade dos Testes
9.
Radiat Res ; 195(3): 253-264, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33347576

RESUMO

With the use of ionizing radiation comes the risk of accidents and malevolent misuse. When unplanned exposures occur, there are several methods which can be used to retrospectively reconstruct individual radiation exposures; biological methods include analysis of aberrations and damage of chromosomes and DNA, while physical methods rely on luminescence (TL/OSL) or EPR signals. To ensure the quality and dependability of these methods, they should be evaluated under realistic exposure conditions. In 2019, EURADOS Working Group 10 and RENEB organized a field test with the purpose of evaluating retrospective dosimetry methods as carried out in potential real-life exposure scenarios. A 1.36 TBq 192Ir source was used to irradiate anthropomorphic phantoms in different geometries at doses of several Gy in an outdoor open-air geometry. Materials intended for accident dosimetry (including mobile phones and blood) were placed on the phantoms together with reference dosimeters (LiF, NaCl, glass). The objective was to estimate radiation exposures received by individuals as measured using blood and fortuitous materials, and to evaluate these methods by comparing the estimated doses to reference measurements and Monte Carlo simulations. Herein we describe the overall planning, goals, execution and preliminary outcomes of the 2019 field test. Such field tests are essential for the development of new and existing methods. The outputs from this field test include useful experience in terms of planning and execution of future exercises, with respect to time management, radiation protection, and reference dosimetry to be considered to obtain relevant data for analysis.


Assuntos
Doses de Radiação , Monitoramento de Radiação/métodos , Radiação Ionizante , Humanos , Radioisótopos de Irídio/efeitos adversos , Método de Monte Carlo , Imagens de Fantasmas , Exposição à Radiação/efeitos adversos , Proteção Radiológica , Radiometria/métodos
10.
Ann ICRP ; 49(1_suppl): 32-44, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32907341

RESUMO

Medical exposures form the largest manmade contributor to total ionising radiation exposure of the UK population. In recent years, new technologies have been developed to improve treatment and prognosis of individuals treated with radiation for diseases such as cancer. However, there is evidence of public, patient, and medical professional concern that radiation protection regulations and practices, as well as understanding of potential long-term adverse health effects of radiation exposure (in the context of other health risks), have not always 'kept pace' with technological developments in this field. This is a truly complex, multi-disciplinary problem for the modern world.The 'Radiation Theme' of the Public Health England and Newcastle University Health Protection Research Unit on 'Chemical and Radiation Threats and Hazards' is addressing this need, with a key focus on a genuinely interdisciplinary approach bringing together world-leading epidemiologists, radiation biologists, clinicians, statisticians, and artists. In addition, the project has a strong grounding in public, patient, and medical professional involvement in research. Similarly, the EU-CONCERT-funded LDLensRad project seeks to understand the mechanisms of action of low-dose ionising radiation in the lens of the eye, and the potential contribution to the development of cataract - in contemporary research, such projects will only be considered successful when they make use of expertise from a variety of fields and when they are able to demonstrate that the outputs are not only of benefit to society, but that society understands and welcomes the benefits. Finally, successful engagement, training, and retention of early career scientists within this field is crucial for sustainability of the research. Herein, the contribution of embedded interdisciplinary working, stakeholder involvement, and training of early career scientists to recent advancements in the field of medical (and wider) radiation protection research is discussed and considered.


Assuntos
Pesquisa Interdisciplinar/estatística & dados numéricos , Proteção Radiológica/métodos , Radiação Ionizante , Participação dos Interessados , Humanos , Proteção Radiológica/normas
11.
Radiat Environ Biophys ; 59(3): 357-387, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32372284

RESUMO

This work presents an overview of the applications of retrospective dosimetry techniques in case of incorporation of radionuclides. The fact that internal exposures are characterized by a spatially inhomogeneous irradiation of the body, which is potentially prolonged over large periods and variable over time, is particularly problematic for biological and electron paramagnetic resonance (EPR) dosimetry methods when compared with external exposures. The paper gives initially specific information about internal dosimetry methods, the most common cytogenetic techniques used in biological dosimetry and EPR dosimetry applied to tooth enamel. Based on real-case scenarios, dose estimates obtained from bioassay data as well as with biological and/or EPR dosimetry are compared and critically discussed. In most of the scenarios presented, concomitant external exposures were responsible for the greater portion of the received dose. As no assay is available which can discriminate between radiation of different types and different LETs on the basis of the type of damage induced, it is not possible to infer from these studies specific conclusions valid for incorporated radionuclides alone. The biological dosimetry assays and EPR techniques proved to be most applicable in cases when the radionuclides are almost homogeneously distributed in the body. No compelling evidence was obtained in other cases of extremely inhomogeneous distribution. Retrospective dosimetry needs to be optimized and further developed in order to be able to deal with real exposure cases, where a mixture of both external and internal exposures will be encountered most of the times.


Assuntos
Radiação Ionizante , Radiometria/métodos , Animais , Espectroscopia de Ressonância de Spin Eletrônica , Humanos , Radioisótopos/farmacocinética
12.
Clin Radiol ; 74(10): 816.e9-816.e17, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31375261

RESUMO

AIM: To determine cumulative scan frequencies and estimate lens dose for paediatric computed tomography (CT) head examinations in the context of potential cataract risk. MATERIALS AND METHODS: The cumulative number of head-region CT examinations among a cohort of 410,997 children and young adults who underwent CT in the UK between 1985 and 2014 was calculated. Images from a sample of these head examinations (n=668) were reviewed to determine the level of eye inclusion. Lens dose per scan was estimated using the computer program, NCICT V1.0, for different levels of eye inclusion and exposure settings typical of past and present clinical practice. RESULTS: In total 284,878 patients underwent 448,108 head-region CT examinations. The majority of patients (72%) had a single recorded head-region examination. A small subset (∼1%, n=2,494) underwent ≥10 examinations, while 0.1% (n=387) underwent ≥20. The lens was included within the imaged region for 57% of reviewed routine head examinations. In many cases, this appeared to be intentional, i.e. protocol driven. In others, there appeared to have been an attempt to exclude the eyes through gantry angulation. Estimated lens doses were 20-75 mGy (mean: 47 mGy) where the eye was fully included within the examination range and 2-7 mGy (mean: 3.1 mGy) where the lens was fully excluded. Potential cumulative lens doses ranged from ∼3 mGy to ∼4,700 mGy, with 2,335 patients potentially receiving >500 mGy. CONCLUSION: The majority of young people will receive cumulative lens doses well below 500 mGy, meaning the risk of cataract induction is likely to be very small.


Assuntos
Cabeça/diagnóstico por imagem , Cristalino/efeitos da radiação , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Adolescente , Catarata/etiologia , Catarata/prevenção & controle , Criança , Pré-Escolar , Estudos de Coortes , Relação Dose-Resposta à Radiação , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Posicionamento do Paciente , Exposição à Radiação/efeitos adversos , Adulto Jovem
13.
Radiat Prot Dosimetry ; 182(1): 128-138, 2018 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-30423161

RESUMO

Biological dosimetry enables individual dose reconstruction in the case of unclear or inconsistent radiation exposure situations, especially when a direct measurement of ionizing radiation is not or is no longer possible. To be prepared for large-scale radiological incidents, networking between well-trained laboratories has been identified as a useful approach for provision of the fast and trustworthy dose assessments needed in such circumstances. To this end, various biodosimetry laboratories worldwide have joined forces and set up regional and/or nationwide networks either on a formal or informal basis. Many of these laboratories are also a part of global networks such as those organized by World Health Organization, International Atomic Energy Agency or Global Health Security Initiative. In the present report, biodosimetry networks from different parts of the world are presented, and the partners, activities and cooperation actions are detailed. Moreover, guidance for situational application of tools used for individual dosimetry is given.


Assuntos
Planejamento em Desastres/organização & administração , Lesões por Radiação/prevenção & controle , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Liberação Nociva de Radioativos/prevenção & controle , Radiometria/métodos , Humanos , Agências Internacionais , Radiação Ionizante
14.
Int J Radiat Biol ; 94(12): 1116-1124, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30359158

RESUMO

PURPOSE: Epidemiological evidence regarding the radiosensitivity of the lens of the eye and radiation cataract development has led to changes in the EU Basic Safety Standards for protection of the lens against ionizing radiation. However, mechanistic details of lens radiation response pathways and their significance for cataractogenesis remain unclear. Radiation-induced DNA damage and the potential impairment of repair pathways within the lens epithelium, a cell monolayer that covers the anterior hemisphere of the lens, are likely to be involved. MATERIALS AND METHODS: In this work, the lens epithelium has been analyzed for its DNA double-strand break (DSB) repair response to ionizing radiation. The responses of epithelial cells located at the anterior pole (central region) have been compared to at the very periphery of the monolayer (germinative and transitional zones). Described here are the different responses in the two regions and across four strains (C57BL/6, 129S2, BALB/c and CBA/Ca) over a low dose (0-25 mGy) in-vivo whole body X-irradiation range up to 24 hours post exposure. RESULTS: DNA damage and repair as visualized through 53BP1 staining was present across the lens epithelium, although repair kinetics appeared non-uniform. Epithelial cells in the central region have significantly more 53BP1 foci. The sensitivities of different mouse strains have also been compared. CONCLUSIONS: 129S2 and BALB/c showed higher levels of DNA damage, with BALB/c showing significantly less inter-individual variability and appearing to be a more robust model for future DNA damage and repair studies. As a result of this study, BALB/c was identified as a suitable radiosensitive lens strain to detect and quantify early low dose ionizing radiation DNA damage effects in the mouse eye lens specifically, as an indicator of cataract formation.


Assuntos
Dano ao DNA , Cristalino/metabolismo , Cristalino/efeitos da radiação , Animais , Reparo do DNA/efeitos da radiação , Relação Dose-Resposta à Radiação , Epitélio/metabolismo , Epitélio/efeitos da radiação , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Tolerância a Radiação/genética , Especificidade da Espécie , Fatores de Tempo
15.
Radiat Prot Dosimetry ; 172(1-3): 254-259, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27431686

RESUMO

In 2014, Health Canada was approached by the Canadian Nuclear Safety Commission to conduct biodosimetry for a possible overexposure 4 y prior to assessment. Dose estimates were determined by means of two cytogenetic assays, the dicentric chromosome assay (DCA) and translocations as measured by the fluorescent in situ hybridization (FISH). As dicentrics are considered to be unstable over time, the results of the DCA were adjusted to account for the time elapsed between the suspected exposure and sampling. The frequency of damage was then compared to Health Canada's calibration curves, respectively, to calculate dose. In addition, the translocation data were corrected for age-related increases in background. With a half-life of 36 months for dicentric chromosomes taken into consideration, the dose estimates from both assays were in agreement. Due to the uncertainty in the half-life of dicentrics, the FISH assay is considered to be more reliable as a technique for retrospective biodosimetry.


Assuntos
Bioensaio/métodos , Aberrações Cromossômicas/efeitos da radiação , Análise Citogenética/métodos , Hibridização In Situ/métodos , Exposição Ocupacional/análise , Exposição à Radiação/análise , Radiometria/métodos , Adulto , Estudos de Casos e Controles , Células Cultivadas , Humanos , Masculino , Doses de Radiação , Liberação Nociva de Radioativos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Radiat Environ Biophys ; 54(4): 433-44, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26205380

RESUMO

Waterborne radioactive releases into the Techa River from the Mayak Production Association in Russia during 1949-1956 resulted in significant doses to about 30,000 persons who lived in downstream settlements. The residents were exposed to internal and external radiation. Two methods for reconstruction of the external dose are considered in this paper, electron paramagnetic resonance (EPR) measurements of teeth, and fluorescence in situ hybridization (FISH) measurements of chromosome translocations in circulating lymphocytes. The main issue in the application of the EPR and FISH methods for reconstruction of the external dose for the Techa Riverside residents was strontium radioisotopes incorporated in teeth and bones that act as a source of confounding local exposures. In order to estimate and subtract doses from incorporated (89,90)Sr, the EPR and FISH assays were supported by measurements of (90)Sr-body burdens and estimates of (90)Sr concentrations in dental tissues by the luminescence method. The resulting dose estimates derived from EPR to FISH measurements for residents of the upper Techa River were found to be consistent: The mean values vary from 510 to 550 mGy for the villages located close to the site of radioactive release to 130-160 mGy for the more distant villages. The upper bound of individual estimates for both methods is equal to 2.2-2.3 Gy. The EPR- and FISH-based dose estimates were compared with the doses calculated for the donors using the most recent Techa River Dosimetry System (TRDS). The TRDS external dose assessments are based on the data on contamination of the Techa River floodplain, simulation of air kerma above the contaminated soil, age-dependent lifestyles and individual residence histories. For correct comparison, TRDS-based doses were calculated from two sources: external exposure from the contaminated environment and internal exposure from (137)Cs incorporated in donors' soft tissues. It is shown here that the TRDS-based absorbed doses in tooth enamel and muscle are in agreement with EPR- and FISH-based estimates within uncertainty bounds. Basically, this agreement between the estimates has confirmed the validity of external doses calculated with the TRDS.


Assuntos
Esmalte Dentário/química , Espectroscopia de Ressonância de Spin Eletrônica , Hibridização in Situ Fluorescente , Músculo Esquelético/química , Exposição à Radiação/análise , Monitoramento de Radiação , Radioisótopos de Estrôncio/análise , Absorção de Radiação , Idoso , Idoso de 80 Anos ou mais , Bioensaio , Feminino , Humanos , Masculino , Liberação Nociva de Radioativos , Resíduos Radioativos/análise , Reprodutibilidade dos Testes , Federação Russa , Sensibilidade e Especificidade , Poluentes Radioativos da Água/análise , Contagem Corporal Total
17.
Ann ICRP ; 44(1 Suppl): 84-90, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25816262

RESUMO

The recommendation from the International Commission on Radiological Protection that the occupational equivalent dose limit for the lens of the eye should be reduced to 20 mSv year(-1), averaged over 5 years with no year exceeding 50 mSv, has stimulated a discussion on the practicalities of implementation of this revised dose limit, and the most appropriate risk and protection framework to adopt. This brief paper provides an overview of some of the drivers behind the move to a lower recommended dose limit. The issue of implementation in the medical sector in the UK has been addressed through a small-scale survey of doses to the lens of the eye amongst interventional cardiologists and radiologists. In addition, a mechanistic study of early and late post-irradiation changes in the lens of the eye in in-vivo-exposed mice is outlined. Surveys and studies such as those described can contribute to a deeper understanding of fundamental and practical issues, and therefore contribute to a robust evidence base for ensuring adequate protection of the eye while avoiding undesirable restrictions to working practices.


Assuntos
Oftalmopatias/etiologia , Cristalino/efeitos da radiação , Exposição Ocupacional , Oftalmologia , Optometria , Lesões por Radiação/etiologia , Animais , Oftalmopatias/patologia , Oftalmopatias/fisiopatologia , Humanos , Camundongos , Doses de Radiação , Lesões por Radiação/patologia , Lesões por Radiação/fisiopatologia , Risco , Reino Unido
18.
Radiat Prot Dosimetry ; 164(3): 265-70, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25118318

RESUMO

In the event of a mass casualty radiation incident, the gamma-H2AX foci assay could be a useful tool to estimate radiation doses received by individuals. The rapid processing time of blood samples of just a few hours and the potential for batch processing, enabling high throughput, make the assay ideal for early triage categorisation to separate the 'worried well' from the low and critically exposed by quantifying radiation-induced foci in peripheral blood lymphocytes. Within the RENEB framework, 8 European laboratories have taken part in the first European gamma-H2AX biodosimetry exercise, which consisted of a telescoring comparison of 200 circulated foci images taken from 8 samples, and a comparison of 10 fresh blood lymphocyte samples that were shipped overnight to participating labs 4 or 24 h post-exposure. Despite large variations between laboratories in the dose-response relationship for foci induction, the obtained results indicate that the network should be able to use the gamma-H2AX assay for rapidly identifying the most severely exposed individuals within a cohort who could then be prioritised for accurate chromosome dosimetry.


Assuntos
Bioensaio/métodos , Dano ao DNA/genética , Raios gama , Histonas/genética , Linfócitos/efeitos da radiação , Exposição à Radiação/análise , Células Cultivadas , Relação Dose-Resposta à Radiação , Europa (Continente) , Imunofluorescência , Humanos , Laboratórios , Linfócitos/fisiologia , Incidentes com Feridos em Massa , Doses de Radiação , Liberação Nociva de Radioativos
19.
Health Phys ; 106(6): 764-71, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24776911

RESUMO

Large scale radiological emergencies require high throughput techniques of biological dosimetry for population triage in order to identify individuals indicated for medical treatment. The dicentric assay is the "gold standard" technique for the performance of biological dosimetry, but it is very time consuming and needs well trained scorers. To increase the throughput of blood samples, semi-automation of dicentric scoring was investigated in the framework of the MULTIBIODOSE EU FP7 project, and dose effect curves were established in six biodosimetry laboratories. To validate these dose effect curves, blood samples from 33 healthy donors (>10 donors/scenario) were irradiated in vitro with 6°Co gamma rays simulating three different exposure scenarios: acute whole body, partial body, and protracted exposure, with three different doses for each scenario. All the blood samples were irradiated at Ghent University, Belgium, and then shipped blind coded to the participating laboratories. The blood samples were set up by each lab using their own standard protocols, and metaphase slides were prepared to validate the calibration curves established by semi-automatic dicentric scoring. In order to achieve this, 300 metaphases per sample were captured, and the doses were estimated using the newly formed dose effect curves. After acute uniform exposure, all laboratories were able to distinguish between 0 Gy, 0.5 Gy, 2.0, and 4.0 Gy (p < 0.001), and, in most cases, the dose estimates were within a range of ± 0.5 Gy of the given dose. After protracted exposure, all laboratories were able to distinguish between 1.0 Gy, 2.0 Gy, and 4.0 Gy (p < 0.001), and here also a large number of the dose estimates were within ± 0.5 Gy of the irradiation dose. After simulated partial body exposure, all laboratories were able to distinguish between 2.0 Gy, 4.0 Gy, and 6.0 Gy (p < 0.001). Overdispersion of the dicentric distribution enabled the detection of the partial body samples; however, this result was clearly dose-dependent. For partial body exposures, only a few dose estimates were in the range of ± 0.5 Gy of the given dose, but an improvement could be achieved with higher cell numbers. The new method of semi-automation of the dicentric assay was introduced successfully in a network of six laboratories. It is therefore concluded that this method can be used as a high-throughput screening tool in a large-scale radiation accident.


Assuntos
Aberrações Cromossômicas/efeitos da radiação , Modelos Biológicos , Radiometria/métodos , Automação , Calibragem , Relação Dose-Resposta à Radiação , Humanos
20.
Radiat Prot Dosimetry ; 159(1-4): 87-94, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24743767

RESUMO

Within the EU MULTIBIODOSE project, the automated micronucleus (MN) assay was optimised for population triage in large-scale radiological emergencies. For MN scoring, two approaches were applied using the Metafer4 platform (MetaSystems, Germany): fully automated scoring and semi-automated scoring with visual inspection of the gallery of MN-positive objects. Dose-response curves were established for acute and protracted whole-body and partial-body exposures. A database of background MN yields was set up, allowing determination of the dose detection threshold in both scoring modes. An analysis of the overdispersion of the MN frequency distribution σ(2)/µ obtained by semi-automated scoring showed that the value of this parameter represents a reliability check of the calculated equivalent total body dose in case the accident overexposure is a partial-body exposure. The elaborated methodology was validated in an accident training exercise. Overall, the semi-automated scoring procedure represents important added value to the automated MN assay.


Assuntos
Planejamento em Desastres/organização & administração , Linfócitos/efeitos da radiação , Testes para Micronúcleos/métodos , Lesões por Radiação/diagnóstico , Monitoramento de Radiação/métodos , Triagem/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Automação , Simulação por Computador , Relação Dose-Resposta à Radiação , Feminino , Raios gama , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Lesões por Radiação/sangue , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...