Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Cardiovasc Electrophysiol ; 34(10): 2055-2064, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37681313

RESUMO

INTRODUCTION: Atrial fibrillation (AF) is a risk factor for reduced cerebral blood flow (CBF) and cognitive dysfunction, even in stroke-free patients. We aimed to test the hypothesis that CBF and hippocampal blood flow (HBF), measured with arterial spin labeling magnetic resonance imaging (MRI), improve after catheter ablation of AF to achieve sinus rhythm (SR). METHODS: A total of 84 stroke-free patients (63.1 ± 9.1 years; paroxysmal AF, n = 50; non-paroxysmal AF, n = 34) undergoing AF catheter ablation were included. MRI studies were done before, 3 months, and 12 months after the procedure with CBF and HBF measurements. RESULTS: Baseline CBF and HBF values in 50 paroxysmal AF patients were used as controls. Baseline CBF was higher in patients with paroxysmal AF than with non-paroxysmal AF (100 ± 32% vs. 86 ± 28%, p = .04). Patients with non-paroxysmal AF had increased CBF 3 months after AF ablation (86 ± 28% to 99 ± 34%, p = .03). Differences in CBF and HBF were greater in the group with AF restored to SR (p < .01). Both CBF and HBF levels at 12 months were unchanged from the 3 months level. Successful rhythm control by catheter ablation was an independent predictor of an increase in CBF > 17.5%. The Mini-Mental State Examination score improved after ablation (p = .02). CONCLUSION: SR restoration with catheter ablation was associated with improved CBF and HBF at 3 months, maintenance of blood flow, and improved cognitive function at 12 months.

2.
J Interv Card Electrophysiol ; 62(1): 21-30, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32939701

RESUMO

PURPOSE: Antral pulmonary vein isolation (PVI) using a radiofrequency hot balloon catheter (RHB) is a feasible therapeutic option for treating atrial fibrillation (AF). Lesion durability after antral RHB-PVI remains unknown. This study aimed to evaluate lesion durability and the associations between procedural characteristics after antral RHB-PVI. METHODS: A total of 200 patients received antral RHB-PVI using the single-shot technique between April 2016 and March 2018. Antral RHB-PVI was performed following a pre-specified protocol and RHB energy application was performed for a maximum of two times for each PV. Consecutive patients who underwent repeated procedures for recurrence of any type of atrial tachyarrhythmia were enrolled. RESULTS: Twenty-six (13%) patients underwent repeated ablation and 20 patient documented AF recurrence (AF group) and 6 patients documented non-AF recurrence (non-AF group). Repeated ablation was performed at a median (25th, 75th percentiles) of 378 days (217, 487) after the initial procedure and durable PVI was observed in 86 (83.5%) PVs. Durability reached 89.7% when PVI was achieved only using an RHB. In the AF group (79 PVs), durable PVI was observed in 62 (78.5%) PVs, whereas all 24 PVs were still isolated in the non-AF group. The majority of reconnection sites were around the superior PVs. CONCLUSIONS: Antral RHB-PVI shows high lesion durability, especially with both inferior PVs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Catéteres , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
3.
JACC Clin Electrophysiol ; 5(10): 1144-1157, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31648739

RESUMO

OBJECTIVES: This study aimed to develop a novel premature ventricular contraction (PVC) mapping method to predict PVC origins in whole ventricles by merging a magnetocardiography (MCG) image with a cardiac computed tomography (CT) image. BACKGROUND: MCG can noninvasively discriminate PVCs originating from the aortic sinus cusp from those originating from the right ventricular outflow tract. METHODS: This study was composed of 22 candidates referred for catheter ablation of idiopathic PVCs. MCG and CT were performed the same day before ablation. Estimated origins by MCG-CT imaging using the recursive null steering spatial filter algorithm were compared with origins determined by electroanatomic mapping (CARTO, Biosense Webster, Inc., Diamond Bar, California) during the ablation procedure. Radiopaque acrylic markers for the CT scan and coil markers generating a weak magnetic field during MCG measurements were used as reference markers to merge the 2 images 3-dimensionally. RESULTS: PVC origins were determined by endocardial and epicardial mapping and ablation results in 18 (86%) patients (right ventricular outflow tract in 10 patients, aortic sinus cusp in 2 patients, interventricular septum in 1 patient, near His bundle in 1 patient, right ventricular free wall in 1 patient, and left ventricular free wall in 3 patients). Estimated origins by MCG-CT imaging matched the origins determined during the procedure in 94% (17 of 18) of patients, whereas the electrocardiography algorithms were accurate in only 56% (10 of 18). Discrimination of an epicardium versus an endocardium or right- versus left-sided septum was successful in 3 of 4 patients (75%). CONCLUSIONS: The diagnostic accuracy of noninvasive MCG-CT mapping was high enough to allow clinical use to predict the site of PVC origins in the whole ventricles.


Assuntos
Magnetocardiografia , Tomografia Computadorizada por Raios X , Complexos Ventriculares Prematuros/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Bloqueio de Ramo/fisiopatologia , Ablação por Cateter , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Seio Aórtico/fisiopatologia , Resultado do Tratamento , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/cirurgia
4.
Sci Rep ; 8(1): 17276, 2018 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-30467393

RESUMO

Renal dysfunction results in the accumulation of various uremic toxins, including indoxyl sulphate (IS), and is a major risk factor for atrial fibrillation (AF). Experimental studies have demonstrated that IS exacerbates atrial remodelling via oxidative stress, inflammation, and fibrosis. However, its clinical impact on AF-promoting cardiac remodelling has not been described. Therefore, the purpose of this study was to clarify the relationship between basal IS levels and the 1-year outcomes after catheter ablation for the treatment of AF. Our prospective observational study included data from 125 patients with AF who underwent catheter ablation. Over a 1-year follow-up period, AF recurrence was identified in 21 patients. The 1-year AF-free survival was significantly lower in patients with high serum IS levels (≥0.65 µg/mL) than in those with low IS levels (60.1 ± 10.4% versus 85.2 ± 3.9%, P = 0.007). Univariable analysis identified that an IS concentration ≥ 0.65 µg/mL was associated with AF recurrence (hazard ratio [HR] = 3.10 [1.26-7.32], P = 0.015), and this association was maintained in multivariate analysis (HR = 3.67 [1.13-11.7], P = 0.031). Thus, in patients undergoing AF ablation, serum IS levels at baseline independently predict the recurrence of arrhythmia.


Assuntos
Fibrilação Atrial/diagnóstico , Ablação por Cateter/métodos , Indicã/sangue , Idoso , Fibrilação Atrial/sangue , Fibrilação Atrial/cirurgia , Intervalo Livre de Doença , Diagnóstico Precoce , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Prognóstico , Estudos Prospectivos , Recidiva
5.
Circ Arrhythm Electrophysiol ; 11(8): e005631, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30354308

RESUMO

Background Both endocardial trigger elimination and epicardial substrate modification are effective in treating ventricular fibrillation (VF) in Brugada syndrome. However, the primary approach and the characteristics of patients who respond to endocardial ablation remain unknown. Methods Among 123 symptomatic Brugada syndrome patients (VF, 63%; syncope, 37%), ablation was performed in 21 VF/electrical storm patients, the majority of whom were resistant to antiarrhythmic drugs. Results Careful endocardial mapping revealed that 81% of the patients had no specific findings, whereas 19% of the patients, who experienced the most frequent VF episodes with notching of the QRS in lead V1, had delayed low-voltage fractionated endocardial electrograms. Ablation of VF triggers followed by endocardial substrate modification was performed in the right ventricular outflow tract in 85% of the cases and in the right ventricle in 15%. VF triggers could not be completely eliminated in 1 patient and VF became noninducible in 14 (88%) patients among 16 patients who underwent VF induction with normalization of Brugada-type ECG in 3. During follow-up (56.14±36.95 months), VF recurrence was observed in 7 patients. Importantly, all patients who had nothing of QRS in lead V1 did not respond to endocardial ablation despite presence of VF-triggering ectopic beats during ablation. Conclusions With careful documentation of VF-triggering ectopic beats and detailed endocardial mapping, endocardial VF trigger elimination followed by endocardial substrate modification has an excellent long-term outcome, whereas presence of QRS notching in lead V1 was associated with high VF recurrence suggesting epicardial substrate ablation as effective initial approach.


Assuntos
Síndrome de Brugada/complicações , Ablação por Cateter/métodos , Endocárdio/cirurgia , Frequência Cardíaca , Fibrilação Ventricular/cirurgia , Potenciais de Ação , Adulto , Antiarrítmicos/uso terapêutico , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/fisiopatologia , Ablação por Cateter/efeitos adversos , Resistência a Medicamentos , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Endocárdio/fisiopatologia , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/fisiopatologia
6.
J Cardiovasc Electrophysiol ; 29(4): 514-522, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29369468

RESUMO

INTRODUCTION: Dominant frequency (DF) derived from fast Fourier transform (FFT) analysis has failed to guide atrial fibrillation (AF) ablation since it cannot guarantee temporal stability. Continuous wavelet transform (CWT) analysis is another frequency analysis that can show the temporal stability of a frequency. METHODS AND RESULTS: Forty-four consecutive patients with persistent AF (PeAF) underwent pulmonary vein (PV) isolation (PVI) as the first-time catheter ablation. The PVs and left atrium were mapped and electrograms (EGMs) were recorded for 30 seconds at each site. Pseudo-frequency (PF) and coefficient of variation (CV) were calculated by CWT analysis. A PF with CV ≤ 10 was defined as a temporally stable PF (sPF). DF was also calculated by traditional FFT analysis from the first 5 seconds of the recorded EGMs. The highest sPF was shown inside the PVs in 20 patients (PV group), and at the non-PV sites in 24 patients (non-PV group). During the follow-up period of 15.3 ± 4.4 months, the ablation success rate in the PV group was significantly higher than that in the non-PV group (90% vs. 62%, P = 0.023). The location of the highest DF did not have a significant effect on ablation success rate between inside the PVs and at the non-PV sites. CONCLUSION: PVI results for PeAF were significantly worse for patients with highest sPF at the non-PV sites compared to patients with highest sPF sites inside the PVs. CWT analysis during AF could be used to verify whether PVI alone is sufficient for the first-time catheter ablation in patients with PeAF.


Assuntos
Potenciais de Ação , Fibrilação Atrial/diagnóstico , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas/métodos , Frequência Cardíaca , Veias Pulmonares/cirurgia , Análise de Ondaletas , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veias Pulmonares/fisiopatologia , Recidiva , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...