Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
ASAIO J ; 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38483812

RESUMO

Physical therapy (PT) benefits for critically ill patients are well recognized; however, little data exist on PT in patients receiving temporary mechanical circulatory support. In this single-center retrospective study (February 2017-January 2022), we analyzed 37 patients who received an axillary Impella device (Abiomed, Danvers, MA) and PT to "prehabilitate" them before durable left ventricular assist device (dLVAD) implantation. The Activity Measure for Post-Acute Care (AM-PAC) Basic Mobility tool assessed the functional status at different points during admission. Immediately after Impella placement, the median AM-PAC score was 12.7 (interquartile range [IQR], 9-15), and the scores continued to significantly increase to 18.4 (IQR, 16-23) before dLVAD and up to 20.7 (IQR, 19-24) at discharge, indicating improved independence. No PT-related complications were reported. Thus, we hypothesize that critically ill patients initially deemed equivocal candidates may safely participate in PT while maximizing functional activities before dLVAD placement.

2.
Innovations (Phila) ; 18(5): 489-493, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37710981

RESUMO

The Impella 5.5® (Abiomed, Danvers, MA, USA) is a microaxial flow pump that promotes left ventricular unloading and improves end-organ perfusion before durable left ventricular assist device (LVAD) implantation. Thrombus formation after Impella 5.5 insertion can occur and represents a significant challenge to device explantation. Durable LVAD implantation is typically performed without aortic cross-clamping, so a dislodged thrombus can potentially embolize and lead to catastrophic events. We describe our technique to safely explant an Impella 5.5 in patients who develop a thrombus on the inflow portion of the device before surgical LVAD implantation.

4.
Tex Heart Inst J ; 50(3)2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-37270296

RESUMO

BACKGROUND: This study assessed in-hospital outcomes of patients with chronic systolic, diastolic, or mixed heart failure (HF) undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). METHODS: The Nationwide Inpatient Sample database was used to identify patients with aortic stenosis and chronic HF who underwent TAVR or SAVR between 2012 and 2015. Propensity score matching and multivariate logistic regression were used to determine outcome risk. RESULTS: A cohort of 9,879 patients with systolic (27.2%), diastolic (52.2%), and mixed (20.6%) chronic HF were included. No statistically significant differences in hospital mortality were noted. Overall, patients with diastolic HF had the shortest hospital stays and lowest costs. Compared with patients with diastolic HF, the risk of acute myocardial infarction (TAVR odds ratio [OR], 1.95; 95% CI, 1.20-3.19; P = .008; SAVR OR, 1.38; 95% CI, 0.98-1.95; P = .067) and cardiogenic shock (TAVR OR, 2.15; 95% CI, 1.43-3.23; P < .001; SAVR OR, 1.89; 95% CI, 1.42-2.53; P ≤ .001) was higher in patients with systolic HF, whereas the risk of permanent pacemaker implantation (TAVR OR, 0.58; 95% CI, 0.45-0.76; P < .001; SAVR OR, 0.58; 95% CI, 0.40-0.84; P = .004) was lower following aortic valve procedures. In TAVR, the risk of acute deep vein thrombosis and kidney injury was higher, although not statistically significant, in patients with systolic HF than in those with diastolic HF. CONCLUSION: These outcomes suggest that chronic HF types do not incur statistically significant hospital mortality risk in patients undergoing TAVR or SAVR.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Fatores de Risco , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Doença Crônica , Insuficiência Cardíaca/etiologia , Mortalidade Hospitalar
6.
ASAIO J ; 69(10): e437-e440, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37220217

RESUMO

TandemHeart (Cardiac Assist Inc., Pittsburgh, PA) is a valuable mechanical circulatory support (MCS) device that provides left atrial to femoral artery bypass and directly unloads the left ventricle. The device is inserted under fluoroscopic guidance in the cardiac catheterization laboratory without requiring invasive surgical exposure. However, this device is unique because it directly unloads the oxygenated blood from the left atrium and may be needed for postoperative support in patients undergoing various open cardiac surgeries. In this article, we provide a detailed description of the open surgical insertion of a TandemHeart device.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Coração Auxiliar , Humanos , Ventrículos do Coração/cirurgia , Átrios do Coração
7.
ASAIO J ; 69(7): e354-e359, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37039827

RESUMO

Frailty and malnutrition in patients with heart failure are barriers to durable left ventricular assist device (D-LVAD) support and heart transplantation. Moreover, cachexia in patients with advanced heart failure carries a high mortality risk. There are no guidelines for these patients other than increased caloric intake and rehabilitation. Patients suffering from cardiac cachexia and heart failure may benefit from temporary, percutaneous assist device support to improve the underlying heart disease and reverse the catabolic state. We retrospectively reviewed patients from January 2017 to January 2022. All patients who received Impella support (5.0 or 5.5, Abiomed) before D-LVAD implantation were screened. Those who met the criteria for cardiac cachexia were included. Patient demographics, nutritional and biochemical markers, and survival data were collected. A total of 14 patients were included. The majority of patients were male (85.7%) with ischemic cardiomyopathy (64.3%). Caloric intake, physical strength, and ambulation improved. Prealbumin levels improved from a median of 13.7-18.0 mg/dl ( p < 0.006) while on Impella 5.0 or 5.5 support. All patients survived to discharge and the 6 month follow-up. In conclusion, use of the Impella device improves cardiogenic shock symptoms and, consequently, may improve cachexia status prior to D-LVAD implantation.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Masculino , Feminino , Estudos Retrospectivos , Caquexia/etiologia , Resultado do Tratamento , Choque Cardiogênico , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia
8.
ASAIO J ; 69(2): e93-e95, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36648364

RESUMO

In patients undergoing aortic valve surgery, preoperative reduced left ventricular ejection fraction is not uncommon and is associated with poor outcomes. Mechanical circulatory support (MCS) may be preemptively used in patients presenting with high periprocedural risk. The Impella 5.5 is a percutaneous left ventricular assist device that has been increasingly used in various cardiac surgeries. In this article, we present a step-by-step guide, safeguards, and pitfalls on how to replace the aortic valve and preserve this transaortic MCS device for postoperative support in patients with concomitant aortic valve pathology and left ventricular dysfunction.


Assuntos
Estenose da Valva Aórtica , Coração Auxiliar , Humanos , Valva Aórtica/cirurgia , Volume Sistólico , Função Ventricular Esquerda , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
9.
J Heart Lung Transplant ; 42(5): 645-650, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36641296

RESUMO

BACKGROUND: Delayed sternal closure may be required after left ventricular assist device (LVAD) implantation due to coagulopathy or hemodynamic instability. There is conflicting data regarding infection risk. METHODS: We performed a single-center, retrospective analysis of patients who received their first LVAD between May 2012 and January 2021. Patients were divided into delayed sternal closure (DSC) and primary sternal closure (PSC) groups. We used chi-squared or Fisher Exact tests, as appropriate, to compare the incidence of postoperative LVAD-related infections (mediastinal/sternal wound) and LVAD-specific infections (driveline and pump pocket) after definitive chest closure between these two groups. RESULTS: A total of 327 patients met eligibility criteria, including 127 (39%) patients that underwent DSC and 200 (61%) patients that had a PSC. Demographic and clinical characteristics were similar except for an overrepresentation of men (87% vs. 75%, p = .016), Interagency Registry of Mechanically Assisted Circulatory Support class I-II patients (89% vs 66%, p < .001), patients with a previous sternotomy (43% vs 13%, p < .001), and patients with chronic kidney disease (55% vs 43%, p = .030) in the DSC group. The median DSC time was 24 (IQR: 24-48) hours. The incidence of LVAD-related mediastinal/sternal wound infection was similar between the DSC and PSC groups (4.7% vs 3.0%, p = .419). There was no difference between DSC and PSC groups in the incidence of driveline infection (6.3% vs 9%, p = .411) and pump pocket infection (1.6% vs 1.5%, p =.901), respectively. CONCLUSIONS: DSC does not seem to increase the incidence of LVAD-related or LVAD-specific infection rates in heart failure patients undergoing device implantation surgery.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Masculino , Humanos , Estudos Retrospectivos , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/epidemiologia , Esternotomia/efeitos adversos , Complicações Pós-Operatórias , Resultado do Tratamento
10.
Protein J ; 42(2): 96-103, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36538202

RESUMO

Acetylcholinesterase (AChE, E.C. 3.1.1.7) termed as the true cholinesterase functions to end cholinergic transmission at synapses. Due to its diverse expression in non-neural tissues such as erythrocytes and bones along with its various molecular forms, researchers seek a non-classical role for this protein. Here, the inhibitory action of unsaturated 18 carbon fatty acids linoleic acid and alpha-linolenic acid and 20 carbon fatty acid arachidonic acid on AChE were investigated. Enzyme activity was measured in kinetic assay method according to Ellman assay utilizing acetylthiocholine. Analysis of the activity data revealed that among the fatty acids examined the IC50 values differed according to the length of the fatty acid and the number of the double bonds. Arachidonic acid, a 20-carbon fatty acid with 4 unsaturated bonds (20:4 n-6, cis 5,8,11,14) displayed an IC50 value of 2.78 µM and Ki value of 396.35 µM. Linoleic acid, an essential 18-carbon fatty acid (18:2 n-6, cis 9,12) had an IC50 value of 7.95 µM and Ki value of 8027.55 µM. The IC50 value of alpha-linolenic acid, 18-carbon fatty acid (18:3 n-3, cis-9,12,15) was found as 179.11 µM. Analysis of the data fit the inhibition mechanism for linoleic, alpha-linolenic and arachidonic acid as mixed-type; non-competitive. Molecular docking complied with these results yielding the best score for arachidonic acid. The alkenyl chain of the fatty acids predictably reached to the catalytic site while the carboxylate strongly interacted with the peripheric anionic site.


Assuntos
Acetilcolinesterase , Ácido Linoleico , Humanos , Ácido Linoleico/farmacologia , Ácido Linoleico/química , Ácido Linoleico/metabolismo , Ácido alfa-Linolênico/farmacologia , Ácido alfa-Linolênico/metabolismo , Simulação de Acoplamento Molecular , Ácidos Graxos Insaturados/metabolismo , Ácidos Graxos , Ácidos Araquidônicos , Carbono
11.
Perfusion ; 38(6): 1196-1202, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-35766358

RESUMO

INTRODUCTION: Advanced age is a known risk factor for poor outcomes after veno-arterial extracorporeal membrane oxygenation (V-A ECMO) for cardiac support. The use of ECMO support in patients over the age of 80 is controversial, and sometimes its use is contraindicated. We aimed to assess the use of ECMO in octogenarian patients to determine survival and complication rates. METHODS: A single-center, retrospective analysis was completed at a large, urban academic medical center. Patients requiring V-A ECMO support between December of 2012 and November of 2019 were included as long as the patient was at least 80 years of age at the time of cannulation. Post cardiotomy shock patients were excluded. RESULTS: A total of 46 patients met eligibility criteria; all received V-A ECMO support. Overall, the majority of patients (71.7%; 33/46) survived to decannulation, and 43.5% (20/46) survived to discharge. Patients who were previously rescued from percutaneous interventions tend to have a better survival than other patients (p = .06). The most common complications were renal and hemorrhagic. CONCLUSIONS: We demonstrated that advanced age alone should not disqualify patients from cannulating and supporting with V-A ECMO.


Assuntos
Oxigenação por Membrana Extracorpórea , Idoso de 80 Anos ou mais , Humanos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Estudos Retrospectivos , Octogenários , Fatores de Risco , Alta do Paciente
13.
Tex Heart Inst J ; 49(6)2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36450144

RESUMO

Minimally invasive aortic valve replacement through a right thoracotomy is frequently performed in patients with aortic valve disease. The Cor-Knot Device (LSI Solutions) is an automated fastener that secures valve sutures. This case report is for a patient who developed postcardiotomy shock during a minimally invasive aortic valve surgery. The patient was found to have an aortic root dissection involving 90% of the aortic root circumference, including bilateral coronary ostia. The autopsy revealed that the aortic damage could be explained by a direct aortic intimal tear from the distal tip of the device shaft. The device was most likely not in perfect apposition to the sewing ring because of the restricted angle and space between the ribs.


Assuntos
Dissecção Aórtica , Humanos , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/etiologia , Dissecção Aórtica/cirurgia , Aorta , Coração , Toracotomia , Suturas
14.
Innovations (Phila) ; 17(5): 377-381, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36189791

RESUMO

Acute decompensated refractory cardiogenic shock is an emergency in which the prompt instauration of mechanical circulatory support improves outcomes. The typical, initial approach for device delivery is via femoral vessels due to easy access and safety. If longer support is needed, the femoral access will severely impair the patient's mobility and can also limit the amount of support given as the new-generation devices are too large for direct arterial insertion. Upper-body arterial conduits (UBACs) are used for the delivery of larger, percutaneous ventricular assist devices (pVADs). The Impella 5.5 (Abiomed, Danvers, MA, USA) is a pVAD that can be deployed through a UBAC by either axillary/subclavian access or a transaortic approach. The latter approach is typically used in cases of postcardiotomy shock, in which the ascending aorta is already exposed through a full sternotomy. However, in some cases, the axillary artery is not suitable due to size (<6 mm in diameter), and a smaller pVAD is delivered into the heart. To avoid providing suboptimal support, we present an alternative, minimally invasive approach in which the larger device is delivered through the ascending aorta. This article summarizes the details of this approach through a mini upper partial sternotomy and reviews the relevant technical considerations.


Assuntos
Artéria Axilar , Coração Auxiliar , Humanos , Artéria Axilar/cirurgia , Esternotomia , Choque Cardiogênico/cirurgia , Resultado do Tratamento
15.
Heart Surg Forum ; 25(4): E525-E529, 2022 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-36052919

RESUMO

BACKGROUND: An inter-institutional collaboration between a quaternary hospital (QH) with a high volume of cardiac surgery and a community-based, tertiary hospital (TH) with a newly established cardiac surgery program was established. METHODS: We retrospectively reviewed data of patients admitted to the TH between September 2015 and June 2017 for cardiac surgery. The decision to transfer a patient to the QH was based on a Society of Thoracic Surgeon-Predicted Risk of Mortality (STS-PROM) score of ≥ 3%, the potential need for hemodialysis, and other risk factors. The same team of surgeons performed operations at both hospitals. We analyzed the perioperative outcomes of the patients and the referral pattern. RESULTS: A total of 116 patients met eligibility criteria; 105 underwent surgery at the TH, while 11 were transferred to the QH. Among the 11 patients transferred to the QH, eight had a score of  3% (median = 8.2 [IQR 5.7-25.0]). The patients transferred to the QH prior to surgery had a significantly higher STS-PROM score (P = ≤ .001). Overall, the mortality of patients who underwent surgery at the TH was 0.9% (1/105); while surgeries at the QH had a mortality rate of 0% (0/11). CONCLUSION: The collaborative effort between high-volume cardiac surgery programs and emerging community-based hospitals showed acceptable outcomes in perioperative cardiac surgical mortality. Elevated STS-PROM scores (>3%), previous sternotomy and anticipation of coagulopathy, and low left ventricular ejection fraction or dilated ventricles are factors that influenced the need to transfer from a TH to QH.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Função Ventricular Esquerda , Humanos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Volume Sistólico , Centros de Atenção Terciária , Resultado do Tratamento
16.
JTCVS Tech ; 14: 96-98, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35967202

RESUMO

Objectives: Implantation and use of vagus nerve stimulation (VNS) systems is a proven treatment strategy for epilepsy and depression, and extensive research regarding vagal control of the heart has led to the idea of VNS as a potential adjunct treatment for heart failure with reduced ejection fraction (HFrEF). We describe our experience with the implantation of an investigational VNS system to manage patients living with HFrEF. Methods: As part of the ongoing ANTHEM-HFrEF (Autonomic Regulation Therapy to Enhance Myocardial Function and Reduce Progression of Heart Failure with Reduced Ejection Fraction) Pivotal Study, a 67-year-old male patient with a history of ischemic cardiomyopathy was randomized to implantation of the VITARIA System (LivaNova Inc). The electrical lead requires no mapping for placement around the vagus nerve. The surgical procedure was completed uneventfully under general anesthesia, and the device was activated in the operating room after surgery. Results: Following successful implantation and activation of the VNS system, the patient was discharged to home on the same day. Conclusions: Current, ongoing studies, such as the ANTHEM-HFrEF Pivotal Study, are designed to determine the long-term effects of VNS on heart failure symptoms, hospitalization rates, and survival. The VNS-implantation procedure was straightforward.

17.
ASAIO J ; 68(12): e251-e255, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-35348311

RESUMO

The Impella CP (Abiomed Inc., Danvers, MA) is widely used in cardiac catheterization laboratories for patients presenting with cardiogenic shock, but it is also known to cause significant hemolysis. The risk of hemolysis can be reduced by properly positioning the device, ensuring an adequate volume status, and using full anticoagulation strategies; however, in some cases hemolysis persists. We present a case series of eight patients that were diagnosed with cardiogenic shock, underwent Impella CP placement, and then suffered from refractory hemolysis which was treated by upgrading the Impella device to the 5.0 or 5.5 version. Fifty percent (4/8) of the patients in this series were already receiving continuous renal replacement therapy, and the levels of plasma free hemoglobin (pFHb) and lactate dehydrogenase continued to increase after the implantation of the Impella CP. The median time between Impella CP placement and the diagnosis of refractory hemolysis was 16.5 hours (interquartile range [IQR], 8.0-26.0). The median time between the diagnosis of hemolysis to Impella upgrade was 6.0 hours (IQR, 4.0-7.0). A total of 87.5% (7/8) of patients experienced a drop in pFHb to below 40 mg/dl at 72 hours post-Impella upgrade, and they were discharged without any further need of dialysis. One patient expired due to irreversible multiple organ failure. We propose that early identification of hemolysis by close monitoring of pFHb and upgrading to the Impella 5.5 reduces hemolysis, prevents further kidney damage, and significantly improves clinical outcomes.


Assuntos
Coração Auxiliar , Choque Cardiogênico , Humanos , Choque Cardiogênico/cirurgia , Coração Auxiliar/efeitos adversos , Hemólise , Estudos Retrospectivos , Resultado do Tratamento
18.
ASAIO J ; 68(7): e113-e115, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-34593680

RESUMO

For the first time, we present a novel technique that enables the exchange of the Impella CP (Abiomed Inc., Danvers, Massachusetts, USA) to the Impella 5.5 (Abiomed Inc.) with no interruption of mechanical support in patients with minimal left ventricular reserve. Specifically, the aortic valve is crossed with the Impella 5.5 whereas the Impella CP is still functioning within the left ventricle. The Impella 5.5 is then initiated, and the Impella CP is weaned. Finally, the Impella CP is pulled out into the descending aorta. This exchange provides continuous support with no hemodynamic disarrangement.


Assuntos
Estenose da Valva Aórtica , Coração Auxiliar , Valva Aórtica , Ventrículos do Coração , Hemodinâmica , Humanos
19.
ASAIO J ; 68(8): e139-e141, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34799527

RESUMO

After demonstrated myocardial recovery in patients with durable left ventricular assist device (LVAD) support, the device may occasionally be explanted. A 38-year-old female with nonischemic cardiomyopathy underwent implantation of an LVAD as a bridge-to-transplant therapy. After one year, the patient demonstrated sufficient myocardial recovery allowing the LVAD to be explanted. A Teflon felt strip plug was created and placed within the apical sewing ring to occlude the opening into the left ventricle. Eleven years later, the patient presented with recurrence of severe heart failure. Due to morbid obesity, the patient was not a heart transplant candidate. Therefore, a second LVAD was implanted with a concomitant gastric sleeve procedure. When the plug was surgically removed from the sewing ring, no thrombus was observed; however, the ventricular surface was completely endothelialized. The patient recovered without any complications, was discharged from the hospital, and is currently listed for a heart transplant. This case demonstrates remission from heart failure lasting for more than a decade. If a second LVAD is needed due to exacerbation of severe heart failure, it can be safely introduced through the previous sewing ring after removing the Teflon plug.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Adulto , Remoção de Dispositivo , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia , Humanos , Politetrafluoretileno , Estudos Retrospectivos , Resultado do Tratamento
20.
Front Cardiovasc Med ; 9: 1072890, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36712267

RESUMO

Background: Carcinoid heart disease (CnHD) is a frequent cause of morbidity and mortality in patients with neuroendocrine tumors and carcinoid syndrome. Although valve replacement surgery appears to decrease all-cause mortality in patients with advanced CnHD, few studies have investigated the outcomes of patients after valve replacement. Methods: We conducted a multi-institution retrospective registry of patients who received both tricuspid and pulmonic bioprosthetic valve (TV/PV) replacements for advanced CnHD from November 2005 to March 2021. Patients were followed post-operatively with echocardiographic studies every 3 months. Carcinoid valvular heart disease scores were used to monitor valve degeneration. Neuroendocrine tumor treatment, their administration times, and associations with echocardiographic findings were recorded. Results: Of 87 patients with CnHD, 22 patients underwent simultaneous surgical TV and PV replacement. In 6 patients (27.3%), increased PV Vmax was the first echocardiographic manifestation of valve degeneration in the setting of occult neurohormonal release. Post-operative telotristat ethyl and peptide receptor radionuclide therapy appeared to stabilize PV Vmax. The PV Vmax showed consistent elevation in the entire patient population when compared to baseline, while bioprosthetic TV echocardiographic parameters were relatively unchanged throughout. Post-operative warfarin therapy did not affect the rate of PV degeneration, and no major bleeding was recorded during or after post-operative anticoagulation therapy. Conclusion: Bioprosthetic valve degeneration is common in CnHD. Monitoring with echocardiographic studies every 3 months, focusing on PV velocities, could identify patients with occult disease that very likely promotes valve degeneration. Novel neuroendocrine tumor therapies may have a beneficial impact on valve degeneration.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...