Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 641(1-2): 110-6, 2009 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-19393374

RESUMO

An automated thermal desorption-gas chromatography-mass spectrometry method for the determination of triazin herbicides in aqueous solution with excellent sensitivity was developed. The method is based on the use of stir bar sorptive extraction. The main parameters such as extraction time, sample volume, the addition of salt and organic modifiers, desorption temperature, desorption flow and desorption time which affect the efficiency of the proposed methodology are fully discussed. The proposed method is sensitive and shows a good linearity within a range of 10-10000 ng L(-1) with correlation coefficients higher than 0.998. Quantitation limits are, in all cases, below the limits accepted by European legislation for human waters consumption and ranging between 11.3 ng L(-1) and 0.7 ng L(-1). The repetitivity, expressed as a relative standard deviation, has values of lower than 8% for all analytes. Using this method, determination of 10 triazines in underground water samples was successfully performed. The average concentrations obtained in the analysis of the spiked samples at two different levels of concentration correspond to mean recoveries ranging from 94.4+/-5.1% to 106.0+/-6.3% for a significance level of 0.05.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Resíduos de Praguicidas/análise , Triazinas/análise , Poluentes Químicos da Água/análise , Adsorção , Fracionamento Químico/métodos , Temperatura Alta , Resíduos de Praguicidas/isolamento & purificação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Triazinas/isolamento & purificação , Poluentes Químicos da Água/isolamento & purificação
2.
J Chromatogr Sci ; 42(2): 74-9, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15023259

RESUMO

Experimental design methodologies are applied to the development of a capillary zone electrophoretic method for the separation of the angiotensin-converting enzyme inhibitor enalapril and its derivative enalaprilat and the diuretics xipamide and hydrochlorothiazide. The effects of pH, buffer concentration, proportion of boric acid in the mixed boric acid-potassium dihydrogen phosphate background electrolyte, temperature, applied voltage, and percentage of organic modifier are studied. Critical factors are identified in a screening design (a 2(6-2) fractional factorial design), and afterwards, optimal conditions for the separation are reached by means of an optimization design (a 2(2) + 2 x 2 + k central composite design). The studied response is the resolution between peaks. The four studied compounds can be separated in less than 3.5 min using an electrolyte of 20mM boric acid-potassium dihydrogen phosphate (75:25, v/v) with 5% MeOH adjusted to pH 8.0 with KOH, at a potential of 30 kV. The detection wavelength and temperature are 206 nm and 35 degrees C, respectively.


Assuntos
Inibidores da Enzima Conversora de Angiotensina/análise , Anti-Hipertensivos/análise , Diuréticos/análise , Eletroforese Capilar/métodos , Enalapril/análise , Enalaprilato/análise , Hidroclorotiazida/análise , Xipamida/análise
3.
J Chromatogr A ; 949(1-2): 91-7, 2002 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-11999762

RESUMO

A simple capillary zone electrophoretic method with UV detection has been developed for the quantitative determination of the beta-adrenoreceptor antagonists (beta-blockers) oxprenolol and timolol in human urine, preceded by a solid-phase extraction step. The electrophoretic separation was performed on a 78 cm x 75 microm I.D. fused-silica capillary (effective capillary length: 70 cm). The electrolyte consisted of a Na2B4O7-H3BO3 (50 mM), pH 9. The introduction of the sample was made hydrostatically for 20 s and the running voltage 25 kV at the injector end of the capillary. Photometric detection was used at a wavelength of 229 nm for oxprenolol and 280 nm for timolol. Under these conditions oxprenolol migrated at 4.76+/-0.05 min and timolol at 4.97+/-0.05 min. The solid-phase extraction methods were optimised for each beta-blocker and provided recoveries of 72.8% for timolol and 94.52% for oxprenolol. Good resolution from the endogenous compounds present in the urine matrix were achieved for both compounds. The method was applied to the determination of both beta-blockers in pharmaceutical formulations and urine samples obtained from hypertensive patients after the ingestion of a therapeutic dose (in a 24-h time interval after the ingestion). The quantitative results were compared with results previously obtained at our laboratories by HPLC and were found to be in good agreement. Good reproducibility, linearity, accuracy and quantitation limits (in urine) of 0.19 microg/ml for timolol and 0.20 microg/ml for oxprenolol were obtained, allowing the method to be applied to pharmacokinetic studies of these compounds.


Assuntos
Antagonistas Adrenérgicos beta/urina , Anti-Hipertensivos/urina , Eletroforese Capilar/métodos , Oxprenolol/urina , Timolol/urina , Antagonistas Adrenérgicos beta/farmacocinética , Anti-Hipertensivos/farmacocinética , Humanos , Oxprenolol/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrofotometria Ultravioleta , Timolol/farmacocinética
4.
J Chromatogr A ; 916(1-2): 279-88, 2001 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-11382302

RESUMO

A capillary zone electrophoresis method has been developed for the quantitation of antihypertensive drug cilazapril and its active metabolite cilazaprilat in pharmaceuticals and urine. The separation of the compounds was performed in a fused-silica capillary filled with the running electrolyte, which consisted of a 60 mM borate buffer solution at pH 9.5. Under the optimized experimental conditions, the separation took less than 5 min. The analysis of urine samples required a previous solid-phase extraction step using C8 cartridges. The method was successfully applied to the determination of the drug and its metabolite in urine samples obtained from three hypertensive patients (detection limits of 115 ng ml(-1) for cilazaprilat and 125 ng ml(-1) for cilazapril) and to pharmaceutical dosage forms. The method was validated in terms of reproducibility, linearity and accuracy.


Assuntos
Inibidores da Enzima Conversora de Angiotensina/análise , Cilazapril/análise , Eletroforese Capilar/métodos , Preparações Farmacêuticas/química , Inibidores da Enzima Conversora de Angiotensina/urina , Cilazapril/urina , Humanos , Hipertensão/urina , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...