Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Eur Radiol Exp ; 8(1): 72, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38740707

RESUMO

Overall quality of radiomics research has been reported as low in literature, which constitutes a major challenge to improve. Consistent, transparent, and accurate reporting is critical, which can be accomplished with systematic use of reporting guidelines. The CheckList for EvaluAtion of Radiomics research (CLEAR) was previously developed to assist authors in reporting their radiomic research and to assist reviewers in their evaluation. To take full advantage of CLEAR, further explanation and elaboration of each item, as well as literature examples, may be useful. The main goal of this work, Explanation and Elaboration with Examples for CLEAR (CLEAR-E3), is to improve CLEAR's usability and dissemination. In this international collaborative effort, members of the European Society of Medical Imaging Informatics-Radiomics Auditing Group searched radiomics literature to identify representative reporting examples for each CLEAR item. At least two examples, demonstrating optimal reporting, were presented for each item. All examples were selected from open-access articles, allowing users to easily consult the corresponding full-text articles. In addition to these, each CLEAR item's explanation was further expanded and elaborated. For easier access, the resulting document is available at https://radiomic.github.io/CLEAR-E3/ . As a complementary effort to CLEAR, we anticipate that this initiative will assist authors in reporting their radiomics research with greater ease and transparency, as well as editors and reviewers in reviewing manuscripts.Relevance statement Along with the original CLEAR checklist, CLEAR-E3 is expected to provide a more in-depth understanding of the CLEAR items, as well as concrete examples for reporting and evaluating radiomic research.Key points• As a complementary effort to CLEAR, this international collaborative effort aims to assist authors in reporting their radiomics research, as well as editors and reviewers in reviewing radiomics manuscripts.• Based on positive examples from the literature selected by the EuSoMII Radiomics Auditing Group, each CLEAR item explanation was further elaborated in CLEAR-E3.• The resulting explanation and elaboration document with examples can be accessed at  https://radiomic.github.io/CLEAR-E3/ .


Assuntos
Lista de Checagem , Humanos , Europa (Continente) , Radiologia/normas , Diagnóstico por Imagem/normas , Radiômica
3.
Insights Imaging ; 15(1): 92, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38530547

RESUMO

OBJECTIVES: To collect real-world data about the knowledge and self-perception of young radiologists concerning the use of contrast media (CM) and the management of adverse drug reactions (ADR). METHODS: A survey (29 questions) was distributed to residents and board-certified radiologists younger than 40 years to investigate the current international situation in young radiology community regarding CM and ADRs. Descriptive statistics analysis was performed. RESULTS: Out of 454 respondents from 48 countries (mean age: 31.7 ± 4 years, range 25-39), 271 (59.7%) were radiology residents and 183 (40.3%) were board-certified radiologists. The majority (349, 76.5%) felt they were adequately informed regarding the use of CM. However, only 141 (31.1%) received specific training on the use of CM and 82 (18.1%) about management ADR during their residency. Although 266 (58.6%) knew safety protocols for handling ADR, 69.6% (316) lacked confidence in their ability to manage CM-induced ADRs and 95.8% (435) expressed a desire to enhance their understanding of CM use and handling of CM-induced ADRs. Nearly 300 respondents (297; 65.4%) were aware of the benefits of contrast-enhanced ultrasound, but 249 (54.8%) of participants did not perform it. The preferred CM injection strategy in CT parenchymal examination and CT angiography examination was based on patient's lean body weight in 318 (70.0%) and 160 (35.2%), a predeterminate fixed amount in 79 (17.4%) and 116 (25.6%), iodine delivery rate in 26 (5.7%) and 122 (26.9%), and scan time in 31 (6.8%) and 56 (12.3%), respectively. CONCLUSION: Training in CM use and management ADR should be implemented in the training of radiology residents. CRITICAL RELEVANCE STATEMENT: We highlight the need for improvement in the education of young radiologists regarding contrast media; more attention from residency programs and scientific societies should be focused on training about contrast media use and the management of adverse drug reactions. KEY POINTS: • This survey investigated training of young radiologists about use of contrast media and management adverse reactions. • Most young radiologists claimed they did not receive dedicated training. • An extreme heterogeneity of responses was observed about contrast media indications/contraindications and injection strategy.

5.
Eur Radiol ; 2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38308012

RESUMO

OBJECTIVES: To evaluate the methodological quality and diagnostic accuracy of MRI-based radiomic studies predicting O6-methylguanine-DNA methyltransferase (MGMT) promoter methylation status in gliomas. METHODS: PubMed Medline, EMBASE, and Web of Science were searched to identify MRI-based radiomic studies on MGMT methylation in gliomas published until December 31, 2022. Three raters evaluated the study methodological quality with Radiomics Quality Score (RQS, 16 components) and Transparent Reporting of a Multivariable Prediction Model for Individual Prognosis Or Diagnosis (TRIPOD, 22 items) scales. Risk of bias and applicability concerns were assessed with QUADAS-2 tool. A meta-analysis was performed to estimate the pooled area under the curve (AUC) and to assess inter-study heterogeneity. RESULTS: We included 26 studies, published from 2016. The median RQS total score was 8 out of 36 (22%, range 8-44%). Thirteen studies performed external validation. All studies reported AUC or accuracy, but only 4 (15%) performed calibration and decision curve analysis. No studies performed phantom analysis, cost-effectiveness analysis, and prospective validation. The overall TRIPOD adherence score was between 50% and 70% in 16 studies and below 50% in 10 studies. The pooled AUC was 0.78 (95% CI, 0.73-0.83, I2 = 94.1%) with a high inter-study heterogeneity. Studies with external validation and including only WHO-grade IV gliomas had significantly lower AUC values (0.65; 95% CI, 0.57-0.73, p < 0.01). CONCLUSIONS: Study RQS and adherence to TRIPOD guidelines was generally low. Radiomic prediction of MGMT methylation status showed great heterogeneity of results and lower performances in grade IV gliomas, which hinders its current implementation in clinical practice. CLINICAL RELEVANCE STATEMENT: MGMT promoter methylation status appears to be variably correlated with MRI radiomic features; radiomic models are not sufficiently robust to be integrated into clinical practice to accurately predict MGMT promoter methylation status in patients with glioma before surgery. KEY POINTS: • Adherence to the indications of TRIPOD guidelines was generally low, as was RQS total score. • MGMT promoter methylation status prediction with MRI radiomic features provided heterogeneous diagnostic accuracy results across studies. • Studies that included grade IV glioma only and performed external validation had significantly lower diagnostic accuracy than others.

6.
Eur Radiol ; 2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38180530

RESUMO

OBJECTIVE: To evaluate the use of reporting checklists and quality scoring tools for self-reporting purposes in radiomics literature. METHODS: Literature search was conducted in PubMed (date, April 23, 2023). The radiomics literature was sampled at random after a sample size calculation with a priori power analysis. A systematic assessment for self-reporting, including the use of documentation such as completed checklists or quality scoring tools, was conducted in original research papers. These eligible papers underwent independent evaluation by a panel of nine readers, with three readers assigned to each paper. Automatic annotation was used to assist in this process. Then, a detailed item-by-item confirmation analysis was carried out on papers with checklist documentation, with independent evaluation of two readers. RESULTS: The sample size calculation yielded 117 papers. Most of the included papers were retrospective (94%; 110/117), single-center (68%; 80/117), based on their private data (89%; 104/117), and lacked external validation (79%; 93/117). Only seven papers (6%) had at least one self-reported document (Radiomics Quality Score (RQS), Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD), or Checklist for Artificial Intelligence in Medical Imaging (CLAIM)), with a statistically significant binomial test (p < 0.001). Median rate of confirmed items for all three documents was 81% (interquartile range, 6). For quality scoring tools, documented scores were higher than suggested scores, with a mean difference of - 7.2 (standard deviation, 6.8). CONCLUSION: Radiomic publications often lack self-reported checklists or quality scoring tools. Even when such documents are provided, it is essential to be cautious, as the accuracy of the reported items or scores may be questionable. CLINICAL RELEVANCE STATEMENT: Current state of radiomic literature reveals a notable absence of self-reporting with documentation and inaccurate reporting practices. This critical observation may serve as a catalyst for motivating the radiomics community to adopt and utilize such tools appropriately, thereby fostering rigor, transparency, and reproducibility of their research, moving the field forward. KEY POINTS: • In radiomics literature, there has been a notable absence of self-reporting with documentation. • Even if such documents are provided, it is critical to exercise caution because the accuracy of the reported items or scores may be questionable. • Radiomics community needs to be motivated to adopt and appropriately utilize the reporting checklists and quality scoring tools.

8.
Insights Imaging ; 15(1): 8, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38228979

RESUMO

PURPOSE: To propose a new quality scoring tool, METhodological RadiomICs Score (METRICS), to assess and improve research quality of radiomics studies. METHODS: We conducted an online modified Delphi study with a group of international experts. It was performed in three consecutive stages: Stage#1, item preparation; Stage#2, panel discussion among EuSoMII Auditing Group members to identify the items to be voted; and Stage#3, four rounds of the modified Delphi exercise by panelists to determine the items eligible for the METRICS and their weights. The consensus threshold was 75%. Based on the median ranks derived from expert panel opinion and their rank-sum based conversion to importance scores, the category and item weights were calculated. RESULT: In total, 59 panelists from 19 countries participated in selection and ranking of the items and categories. Final METRICS tool included 30 items within 9 categories. According to their weights, the categories were in descending order of importance: study design, imaging data, image processing and feature extraction, metrics and comparison, testing, feature processing, preparation for modeling, segmentation, and open science. A web application and a repository were developed to streamline the calculation of the METRICS score and to collect feedback from the radiomics community. CONCLUSION: In this work, we developed a scoring tool for assessing the methodological quality of the radiomics research, with a large international panel and a modified Delphi protocol. With its conditional format to cover methodological variations, it provides a well-constructed framework for the key methodological concepts to assess the quality of radiomic research papers. CRITICAL RELEVANCE STATEMENT: A quality assessment tool, METhodological RadiomICs Score (METRICS), is made available by a large group of international domain experts, with transparent methodology, aiming at evaluating and improving research quality in radiomics and machine learning. KEY POINTS: • A methodological scoring tool, METRICS, was developed for assessing the quality of radiomics research, with a large international expert panel and a modified Delphi protocol. • The proposed scoring tool presents expert opinion-based importance weights of categories and items with a transparent methodology for the first time. • METRICS accounts for varying use cases, from handcrafted radiomics to entirely deep learning-based pipelines. • A web application has been developed to help with the calculation of the METRICS score ( https://metricsscore.github.io/metrics/METRICS.html ) and a repository created to collect feedback from the radiomics community ( https://github.com/metricsscore/metrics ).

9.
Eur Radiol ; 34(4): 2805-2815, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37740080

RESUMO

OBJECTIVE: To evaluate the usage of a well-known and widely adopted checklist, Checklist for Artificial Intelligence in Medical imaging (CLAIM), for self-reporting through a systematic analysis of its citations. METHODS: Google Scholar, Web of Science, and Scopus were used to search for citations (date, 29 April 2023). CLAIM's use for self-reporting with proof (i.e., filled-out checklist) and other potential use cases were systematically assessed in research papers. Eligible papers were evaluated independently by two readers, with the help of automatic annotation. Item-by-item confirmation analysis on papers with checklist proof was subsequently performed. RESULTS: A total of 391 unique citations were identified from three databases. Of the 118 papers included in this study, 12 (10%) provided a proof of self-reported CLAIM checklist. More than half (70; 59%) only mentioned some sort of adherence to CLAIM without providing any proof in the form of a checklist. Approximately one-third (36; 31%) cited the CLAIM for reasons unrelated to their reporting or methodological adherence. Overall, the claims on 57 to 93% of the items per publication were confirmed in the item-by-item analysis, with a mean and standard deviation of 81% and 10%, respectively. CONCLUSION: Only a small proportion of the publications used CLAIM as checklist and supplied filled-out documentation; however, the self-reported checklists may contain errors and should be approached cautiously. We hope that this systematic citation analysis would motivate artificial intelligence community about the importance of proper self-reporting, and encourage researchers, journals, editors, and reviewers to take action to ensure the proper usage of checklists. CLINICAL RELEVANCE STATEMENT: Only a small percentage of the publications used CLAIM for self-reporting with proof (i.e., filled-out checklist). However, the filled-out checklist proofs may contain errors, e.g., false claims of adherence, and should be approached cautiously. These may indicate inappropriate usage of checklists and necessitate further action by authorities. KEY POINTS: • Of 118 eligible papers, only 12 (10%) followed the CLAIM checklist for self-reporting with proof (i.e., filled-out checklist). More than half (70; 59%) only mentioned some kind of adherence without providing any proof. • Overall, claims on 57 to 93% of the items were valid in item-by-item confirmation analysis, with a mean and standard deviation of 81% and 10%, respectively. • Even with the checklist proof, the items declared may contain errors and should be approached cautiously.


Assuntos
Inteligência Artificial , Lista de Checagem , Humanos , Diagnóstico por Imagem , Radiografia
10.
Diagn Interv Radiol ; 30(2): 80-90, 2024 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-37789676

RESUMO

With the advent of large language models (LLMs), the artificial intelligence revolution in medicine and radiology is now more tangible than ever. Every day, an increasingly large number of articles are published that utilize LLMs in radiology. To adopt and safely implement this new technology in the field, radiologists should be familiar with its key concepts, understand at least the technical basics, and be aware of the potential risks and ethical considerations that come with it. In this review article, the authors provide an overview of the LLMs that might be relevant to the radiology community and include a brief discussion of their short history, technical basics, ChatGPT, prompt engineering, potential applications in medicine and radiology, advantages, disadvantages and risks, ethical and regulatory considerations, and future directions.


Assuntos
Inteligência Artificial , Radiologia , Humanos , Radiografia , Radiologistas , Idioma
11.
Eur Radiol ; 34(4): 2791-2804, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37733025

RESUMO

OBJECTIVES: To investigate the intra- and inter-rater reliability of the total radiomics quality score (RQS) and the reproducibility of individual RQS items' score in a large multireader study. METHODS: Nine raters with different backgrounds were randomly assigned to three groups based on their proficiency with RQS utilization: Groups 1 and 2 represented the inter-rater reliability groups with or without prior training in RQS, respectively; group 3 represented the intra-rater reliability group. Thirty-three original research papers on radiomics were evaluated by raters of groups 1 and 2. Of the 33 papers, 17 were evaluated twice with an interval of 1 month by raters of group 3. Intraclass coefficient (ICC) for continuous variables, and Fleiss' and Cohen's kappa (k) statistics for categorical variables were used. RESULTS: The inter-rater reliability was poor to moderate for total RQS (ICC 0.30-055, p < 0.001) and very low to good for item's reproducibility (k - 0.12 to 0.75) within groups 1 and 2 for both inexperienced and experienced raters. The intra-rater reliability for total RQS was moderate for the less experienced rater (ICC 0.522, p = 0.009), whereas experienced raters showed excellent intra-rater reliability (ICC 0.91-0.99, p < 0.001) between the first and second read. Intra-rater reliability on RQS items' score reproducibility was higher and most of the items had moderate to good intra-rater reliability (k - 0.40 to 1). CONCLUSIONS: Reproducibility of the total RQS and the score of individual RQS items is low. There is a need for a robust and reproducible assessment method to assess the quality of radiomics research. CLINICAL RELEVANCE STATEMENT: There is a need for reproducible scoring systems to improve quality of radiomics research and consecutively close the translational gap between research and clinical implementation. KEY POINTS: • Radiomics quality score has been widely used for the evaluation of radiomics studies. • Although the intra-rater reliability was moderate to excellent, intra- and inter-rater reliability of total score and point-by-point scores were low with radiomics quality score. • A robust, easy-to-use scoring system is needed for the evaluation of radiomics research.


Assuntos
Radiômica , Leitura , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes
12.
Eur Radiol ; 34(1): 436-443, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37572188

RESUMO

OBJECTIVES: To investigate the model-, code-, and data-sharing practices in the current radiomics research landscape and to introduce a radiomics research database. METHODS: A total of 1254 articles published between January 1, 2021, and December 31, 2022, in leading radiology journals (European Radiology, European Journal of Radiology, Radiology, Radiology: Artificial Intelligence, Radiology: Cardiothoracic Imaging, Radiology: Imaging Cancer) were retrospectively screened, and 257 original research articles were included in this study. The categorical variables were compared using Fisher's exact tests or chi-square test and numerical variables using Student's t test with relation to the year of publication. RESULTS: Half of the articles (128 of 257) shared the model by either including the final model formula or reporting the coefficients of selected radiomics features. A total of 73 (28%) models were validated on an external independent dataset. Only 16 (6%) articles shared the data or used publicly available open datasets. Similarly, only 20 (7%) of the articles shared the code. A total of 7 (3%) articles both shared code and data. All collected data in this study is presented in a radiomics research database (RadBase) and could be accessed at https://github.com/EuSoMII/RadBase . CONCLUSION: According to the results of this study, the majority of published radiomics models were not technically reproducible since they shared neither model nor code and data. There is still room for improvement in carrying out reproducible and open research in the field of radiomics. CLINICAL RELEVANCE STATEMENT: To date, the reproducibility of radiomics research and open science practices within the radiomics research community are still very low. Ensuring reproducible radiomics research with model-, code-, and data-sharing practices will facilitate faster clinical translation. KEY POINTS: • There is a discrepancy between the number of published radiomics papers and the clinical implementation of these published radiomics models. • The main obstacle to clinical implementation is the lack of model-, code-, and data-sharing practices. • In order to translate radiomics research into clinical practice, the radiomics research community should adopt open science practices.


Assuntos
Inteligência Artificial , Radiômica , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Radiografia
13.
Radiol Artif Intell ; 5(5): e220292, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37795138

RESUMO

Purpose: To predict the corresponding age of myelin maturation from brain MRI scans in infants and young children by using a deep learning algorithm and to build upon previously published models. Materials and Methods: Brain MRI scans acquired between January 1, 2011, and March 17, 2021, in our institution in patients aged 0-3 years were retrospectively retrieved from the archive. An ensemble of two-dimensional (2D) and three-dimensional (3D) convolutional neural network models was trained and internally validated in 710 patients to predict myelin maturation age on the basis of radiologist-generated labels. The model ensemble was tested on an internal dataset of 123 patients and two external datasets of 226 (0-25 months of age) and 383 (0-2 months of age) healthy children and infants, respectively. Mean absolute error (MAE) and Pearson correlation coefficients were used to assess model performance. Results: The 2D, 3D, and 2D-plus-3D ensemble models showed MAE values of 1.43, 2.55, and 1.77 months, respectively, on the internal test set, values of 2.26, 2.27, and 1.22 months on the first external test set, and values of 0.44, 0.27, and 0.31 months on the second external test set. The ensemble model outperformed the previous state-of-the-art model on the same external test set (MAE = 1.22 vs 2.09 months). Conclusion: The proposed deep learning model accurately predicted myelin maturation age using pediatric brain MRI scans and may help reduce the time needed to complete this task, as well as interobserver variability in radiologist predictions.Keywords: Pediatrics, MR Imaging, CNS, Brain/Brain Stem, Convolutional Neural Network (CNN), Artificial Intelligence, Pediatric Imaging, Myelin Maturation, Brain MRI, Neuroradiology Supplemental material is available for this article. © RSNA, 2023.

15.
Eur Radiol ; 33(3): 1884-1894, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36282312

RESUMO

OBJECTIVE: The main aim of the present systematic review was a comprehensive overview of the Radiomics Quality Score (RQS)-based systematic reviews to highlight common issues and challenges of radiomics research application and evaluate the relationship between RQS and review features. METHODS: The literature search was performed on multiple medical literature archives according to PRISMA guidelines for systematic reviews that reported radiomic quality assessment through the RQS. Reported scores were converted to a 0-100% scale. The Mann-Whitney and Kruskal-Wallis tests were used to compare RQS scores and review features. RESULTS: The literature research yielded 345 articles, from which 44 systematic reviews were finally included in the analysis. Overall, the median of RQS was 21.00% (IQR = 11.50). No significant differences of RQS were observed in subgroup analyses according to targets (oncological/not oncological target, neuroradiology/body imaging focus and one imaging technique/more than one imaging technique, characterization/prognosis/detection/other). CONCLUSIONS: Our review did not reveal a significant difference of quality of radiomic articles reported in systematic reviews, divided in different subgroups. Furthermore, low overall methodological quality of radiomics research was found independent of specific application domains. While the RQS can serve as a reference tool to improve future study designs, future research should also be aimed at improving its reliability and developing new tools to meet an ever-evolving research space. KEY POINTS: • Radiomics is a promising high-throughput method that may generate novel imaging biomarkers to improve clinical decision-making process, but it is an inherently complex analysis and often lacks reproducibility and generalizability. • The Radiomics Quality Score serves a necessary role as the de facto reference tool for assessing radiomics studies. • External auditing of radiomics studies, in addition to the standard peer-review process, is valuable to highlight common limitations and provide insights to improve future study designs and practical applicability of the radiomics models.


Assuntos
Diagnóstico por Imagem , Humanos , Reprodutibilidade dos Testes , Prognóstico , Biomarcadores
16.
J Cardiovasc Magn Reson ; 23(1): 133, 2021 11 11.
Artigo em Inglês | MEDLINE | ID: mdl-34758821

RESUMO

BACKGROUND: Artificial intelligence can assist in cardiac image interpretation. Here, we achieved a substantial reduction in time required to read a cardiovascular magnetic resonance (CMR) study to estimate left atrial volume without compromising accuracy or reliability. Rather than deploying a fully automatic black-box, we propose to incorporate the automated LA volumetry into a human-centric interactive image-analysis process. METHODS AND RESULTS: Atri-U, an automated data analysis pipeline for long-axis cardiac cine images, computes the atrial volume by: (i) detecting the end-systolic frame, (ii) outlining the endocardial borders of the LA, (iii) localizing the mitral annular hinge points and constructing the longitudinal atrial diameters, equivalent to the usual workup done by clinicians. In every step human interaction is possible, such that the results provided by the algorithm can be accepted, corrected, or re-done from scratch. Atri-U was trained and evaluated retrospectively on a sample of 300 patients and then applied to a consecutive clinical sample of 150 patients with various heart conditions. The agreement of the indexed LA volume between Atri-U and two experts was similar to the inter-rater agreement between clinicians (average overestimation of 0.8 mL/m2 with upper and lower limits of agreement of - 7.5 and 5.8 mL/m2, respectively). An expert cardiologist blinded to the origin of the annotations rated the outputs produced by Atri-U as acceptable in 97% of cases for step (i), 94% for step (ii) and 95% for step (iii), which was slightly lower than the acceptance rate of the outputs produced by a human expert radiologist in the same cases (92%, 100% and 100%, respectively). The assistance of Atri-U lead to an expected reduction in reading time of 66%-from 105 to 34 s, in our in-house clinical setting. CONCLUSIONS: Our proposal enables automated calculation of the maximum LA volume approaching human accuracy and precision. The optional user interaction is possible at each processing step. As such, the assisted process sped up the routine CMR workflow by providing accurate, precise, and validated measurement results.


Assuntos
Inteligência Artificial , Imagem Cinética por Ressonância Magnética , Átrios do Coração/diagnóstico por imagem , Humanos , Interpretação de Imagem Assistida por Computador , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos
17.
Front Neurol ; 12: 630435, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33935939

RESUMO

Background: Muscles from patients with cerebral palsy (CP) are often spastic and form contractures that limit the range of motion. Injections of botulinum toxin A (BTX) into the calf muscles are an important treatment for functional equinus; however, improvement in gait function is not always achieved. BTX is also used to test muscle weakening for risk evaluation of muscle lengthening surgery. Our aim was to assess the effect of BTX over time on calf muscle properties in pediatric CP patients with MRI. Material and Methods: Six toe-walking CP patients (mean age 11.6 years) with indication for lengthening surgery were prospectively enrolled and received BTX injections into the gastrocnemius and soleus muscles. MRI scans at 3T of the lower legs and clinical examinations were performed pre-BTX, 6 weeks (6w), and 12 weeks (12w) post-BTX. A fat-suppressed 2D multi-spin-echo sequence was used to acquire T2 maps and for segmentation. Fat fraction maps were calculated from 3D multi-echo Dixon images. Diffusion tensor imaging (DTI) with a 2D echo-planar imaging (EPI) sequence yielded maps of the mean apparent diffusion coefficient (ADC) and of the fractional anisotropy (FA). Hyperintense regions of interest (ROIs) on the T2-weighted (T2w) images at 6w were segmented in treated muscles. Mean values of T2, fat fraction, ADC, and FA were calculated in hyperintense ROIs and in reference ROIs in non-treated muscles. Results: Hyperintensity on T2w scans and increased T2 (group mean ± standard deviation: 35 ± 1 ms pre-BTX, 45 ± 2 ms at 6w, and 44 ± 2 ms at 12w) were observed in all patients at the injection sites. The T2 increase was spatially limited to parts of the injected muscles. FA increased (0.30 ± 0.03 pre-BTX, 0.34 ± 0.02 at 6w, and 0.36 ± 0.03 at 12w) while ADC did not change in hyperintense ROIs, indicating a BTX-induced increase in extracellular space and a simultaneous decrease of muscle fiber diameter. Fat fraction showed a trend for increase at 12w. Mean values in reference ROIs remained unchanged. Conclusion: MRI showed limited spatial distribution of the BTX-induced effects in pediatric CP patients. It could be a promising non-invasive tool for future studies to test BTX treatment protocols.

18.
Front Neurol ; 12: 633808, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33828520

RESUMO

Background: Cerebral palsy (CP) is the most common cause of physical disability in childhood. Muscle pathologies occur due to spasticity and contractures; therefore, diagnostic imaging to detect pathologies is often required. Imaging has been used to assess torsion or estimate muscle volume, but additional methods for characterizing muscle composition have not thoroughly been investigated. MRI fat fraction (FF) measurement can quantify muscle fat and is often a part of standard imaging in neuromuscular dystrophies. To date, FF has been used to quantify muscle fat and assess function in CP. In this study, we aimed to utilize a radiomics and FF analysis along with the combination of both methods to differentiate affected muscles from healthy ones. Materials and Methods: A total of 9 patients (age range 8-15 years) with CP and 12 healthy controls (age range 9-16 years) were prospectively enrolled (2018-2020) after ethics committee approval. Multi-echo Dixon acquisition of the calf muscles was used for FF calculation. The images of the second echo (TE = 2.87 ms) were used for feature extraction from the soleus, gastrocnemius medialis, and gastrocnemius lateralis muscles. The least absolute shrinkage and selection operator (LASSO) regression was employed for feature selection. RM, FF model (FFM), and combined model (CM) were built for each calf muscle. The receiver operating characteristic (ROC) curve and their respective area under the curve (AUC) values were used to evaluate model performance. Results: In total, the affected legs of 9 CP patients and the dominant legs of 12 healthy controls were analyzed. The performance of RM for soleus, gastrocnemius medialis, and gastrocnemius lateralis (AUC 0.92, 0.92, 0.82, respectively) was better than the FFM (AUC 0.88, 0.85, 0.69, respectively). The combination of both models always had a better performance than RM or FFM (AUC 0.95, 0.93, 0.83). FF was higher in the patient group (FFS 9.1%, FFGM 8.5%, and FFGL 10.2%) than control group (FFS 3.3%, FFGM 4.1%, FFGL 6.6%). Conclusion: The combination of MRI quantitative fat fraction analysis and texture analysis of muscles is a promising tool to evaluate muscle pathologies due to CP in a non-invasive manner.

19.
Diagn Interv Radiol ; 26(5): 504-511, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32755879

RESUMO

Artificial intelligence (AI) has great potential to accelerate scientific discovery in medicine and to transform healthcare. In radiology, AI is about to enter into clinical practice and has a wide range of applications covering the whole diagnostic workflow. However, AI applications are not smooth sailing. It is crucial to understand the potential risks and hazards that come with this new technology. We have to implement AI in the best possible way to reflect the time-honored ethical and legal standards while ensuring the adequate protection of patient interests. These issues are discussed under the light of core biomedical ethics principles and principles for AI-specific ethical challenges while giving an overview of the statements that were proposed for the ethics of AI applications in radiology.


Assuntos
Inteligência Artificial , Radiologia , Humanos , Radiografia , Fluxo de Trabalho
20.
Eur Radiol ; 30(1): 652-662, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31410603

RESUMO

OBJECTIVE: To compare the robustness of native T1 mapping using mean and median pixel-wise quantification methods. METHODS: Fifty-seven consecutive patients without overt signs of heart failure were examined in clinical routine for suspicion of cardiomyopathy. MRI included the acquisition of native T1 maps by a motion-corrected modified Look-Locker inversion recovery sequence at 1.5 T. Heart function status according to four established volumetric left ventricular (LV) cardio MRI parameter thresholds was used for retrospective separation into subgroups of normal (n = 26) or abnormal heart function (n = 31). Statistical normality of pixel-wise T1 was tested on each myocardial segment and mean and median segmental T1 values were assessed. RESULTS: Segments with normally distributed pixel-wise T1 (57/58%) showed no difference between mean and median quantification in either patient group, while differences were highly significant (p < 0.001) for the respective 43/42% non-normally distributed segments. Heart function differentiation between two patient groups was significant in 14 myocardial segments (p < 0.001-0.040) by median quantification compared with six (p < 0.001-0.042) by using the mean. The differences by median quantification were observed between the native T1 values of the three coronary artery territories of normal heart function patients (p = 0.023) and insignificantly in the abnormal patients (p = 0.053). CONCLUSION: Median quantification increases the robustness of myocardial native T1 definition, regardless of statistical normality of the data. Compared with the currently prevailing method of mean quantification, differentiation between LV segments and coronary artery territories is better and allows for earlier detection of heart function impairment. KEY POINTS: • Median pixel-wise quantification of native T1 maps is robust and can be applied regardless of the statistical distribution of data points. • Median quantification is more sensitive to early heart function abnormality compared with mean quantification. • The new method yields significant native T1 value differentiation between the three coronary artery territories.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Coração/diagnóstico por imagem , Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...