Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Curr Radiopharm ; 15(2): 141-147, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34636317

RESUMO

BACKGROUND AND OBJECTIVE: Herniarin is a simple coumarin that is found naturally in some plant species. In this study, we aimed to evaluate the protective effect of herniarin against ionizing radiation-induced genotoxicity and cytotoxicity in human peripheral blood lymphocytes. METHODS: Herniarin was added to human lymphocytes before irradiation with a dose of 2 Gy of Xrays. The antagonistic potential of herniarin against radiation was measured by MTT [3-(4,5- dimethyl-2-thiazolyl)-2,5-diphenyl-2H tetrazolium bromide] assay, micronucleus assay, flow cytometry, and reactive oxygen species (ROS) level analysis. RESULTS: The maximum survival of lymphocytes against radiation was observed at a concentration of 50 µM of herniarin and a treatment time of 1 h. Pretreatment with 50 µM herniarin significantly decreased the micronuclei frequency, the percentage of apoptotic lymphocytes, and the ROS level in irradiated human lymphocytes. Moreover, 50 µM herniarin significantly increased the cytokinesis blocked proliferation index in irradiated lymphocytes. CONCLUSION: Herniarin could reduce radiation-induced cytotoxicity and genotoxicity in human lymphocytes. To complete the results of this study, it is suggested that in the future, more preclinical studies with larger samples or animal models be performed on herniarin.


Assuntos
Protetores contra Radiação , Células Cultivadas , Dano ao DNA , Raios gama , Humanos , Linfócitos , Radiação Ionizante , Protetores contra Radiação/farmacologia , Compostos Radiofarmacêuticos/farmacologia , Espécies Reativas de Oxigênio/farmacologia , Umbeliferonas
2.
Radiat Prot Dosimetry ; 190(2): 217-225, 2020 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-32696972

RESUMO

This paper presents the results of the evaluation of the uncertainty in measurement of the personal dose equivalent, Hp(10), at nine individual monitoring services (IMSs) in Asia and the Pacific region. Different types of passive dosemeters were type-tested according to the International Electrotechnical Commission 62387 requirements. The uncertainty in measurement was calculated using the Guide to the Expression of Uncertainty in Measurement approach. Expanded uncertainties ranged between 24 and 86% (average = 38%) for Hp(10) values around 1 mSv and between 14 and 40% (average = 27%) for doses around the annual dose limit, Hp(10) = 20 mSv. The expanded uncertainties were lower than the 1.5 factor in either direction proposed by the International Commission on Radiological Protection for doses near the relevant dose limits. This indicates an acceptable level of uncertainty for all participating IMSs. Uncertainty evaluation will help the IMSs to acknowledge the accuracy of their measurements.


Assuntos
Exposição Ocupacional , Monitoramento de Radiação , Ásia , Exposição Ocupacional/análise , Doses de Radiação , Incerteza
3.
Radiat Prot Dosimetry ; 187(4): 418-425, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-31605130

RESUMO

An intercomparison exercise (IC) on whole body dosemeters to determine the quantity personal dose equivalent Hp (10) in photon radiation fields was jointly organised and conducted by the International Atomic Energy Agency (IAEA) and the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) for individual monitoring services (IMS) in Asia and the Pacific region. This was arranged to help the IMS in the region to achieve a more accurate dosimetry service and to improve their performance. Twenty-four IMS participated in this IC. Four sets of dosemeters were irradiated using X-ray and gamma radiation qualities at 0° and 20° angle of incidence, respectively. All the IMS provided results that were within the acceptable limits defined by the IAEA. However, only a minority of participants reported confidence intervals that included the reference dose, for each exposure scenario. For few systems, the overall performance could be significantly improved by reviewing calibration procedures.


Assuntos
Exposição Ocupacional/análise , Fótons , Dosímetros de Radiação/normas , Monitoramento de Radiação/normas , Proteção Radiológica/normas , Contagem Corporal Total/normas , Ásia , Austrália , Humanos , Energia Nuclear , Exposição Ocupacional/prevenção & controle , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...