Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
1.
Circulation ; 149(14): e1028-e1050, 2024 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-38415358

RESUMO

A major focus of academia, industry, and global governmental agencies is to develop and apply artificial intelligence and other advanced analytical tools to transform health care delivery. The American Heart Association supports the creation of tools and services that would further the science and practice of precision medicine by enabling more precise approaches to cardiovascular and stroke research, prevention, and care of individuals and populations. Nevertheless, several challenges exist, and few artificial intelligence tools have been shown to improve cardiovascular and stroke care sufficiently to be widely adopted. This scientific statement outlines the current state of the art on the use of artificial intelligence algorithms and data science in the diagnosis, classification, and treatment of cardiovascular disease. It also sets out to advance this mission, focusing on how digital tools and, in particular, artificial intelligence may provide clinical and mechanistic insights, address bias in clinical studies, and facilitate education and implementation science to improve cardiovascular and stroke outcomes. Last, a key objective of this scientific statement is to further the field by identifying best practices, gaps, and challenges for interested stakeholders.


Assuntos
Doenças Cardiovasculares , Cardiopatias , Acidente Vascular Cerebral , Estados Unidos , Humanos , Inteligência Artificial , American Heart Association , Doenças Cardiovasculares/terapia , Doenças Cardiovasculares/prevenção & controle , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/prevenção & controle
2.
Heart Rhythm O2 ; 4(11): 715-722, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38034889

RESUMO

Background: Continuous electrocardiographic (ECG) monitoring is used to identify ventricular tachycardia (VT), but false alarms occur frequently. Objective: The purpose of this study was to assess the rate of 30-day in-hospital mortality associated with VT alerts generated from bedside ECG monitors to those from a new algorithm among intensive care unit (ICU) patients. Methods: We conducted a retrospective cohort study in consecutive adult ICU patients at an urban academic medical center and compared current bedside monitor VT alerts, VT alerts from a new-unannotated algorithm, and true-annotated VT. We used survival analysis to explore the association between VT alerts and mortality. Results: We included 5679 ICU admissions (mean age 58 ± 17 years; 48% women), 503 (8.9%) experienced 30-day in-hospital mortality. A total of 30.1% had at least 1 current bedside monitor VT alert, 14.3% had a new-unannotated algorithm VT alert, and 11.6% had true-annotated VT. Bedside monitor VT alert was not associated with increased rate of 30-day mortality (adjusted hazard ratio [aHR] 1.06; 95% confidence interval [CI] 0.88-1.27), but there was an association for VT alerts from our new-unannotated algorithm (aHR 1.38; 95% CI 1.12-1.69) and true-annotated VT(aHR 1.39; 95% CI 1.12-1.73). Conclusion: Unannotated and annotated-true VT were associated with increased rate of 30-day in-hospital mortality, whereas current bedside monitor VT was not. Our new algorithm may accurately identify high-risk VT; however, prospective validation is needed.

6.
Nat Med ; 29(7): 1804-1813, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37386246

RESUMO

Patients with occlusion myocardial infarction (OMI) and no ST-elevation on presenting electrocardiogram (ECG) are increasing in numbers. These patients have a poor prognosis and would benefit from immediate reperfusion therapy, but, currently, there are no accurate tools to identify them during initial triage. Here we report, to our knowledge, the first observational cohort study to develop machine learning models for the ECG diagnosis of OMI. Using 7,313 consecutive patients from multiple clinical sites, we derived and externally validated an intelligent model that outperformed practicing clinicians and other widely used commercial interpretation systems, substantially boosting both precision and sensitivity. Our derived OMI risk score provided enhanced rule-in and rule-out accuracy relevant to routine care, and, when combined with the clinical judgment of trained emergency personnel, it helped correctly reclassify one in three patients with chest pain. ECG features driving our models were validated by clinical experts, providing plausible mechanistic links to myocardial injury.


Assuntos
Serviço Hospitalar de Emergência , Infarto do Miocárdio , Humanos , Fatores de Tempo , Infarto do Miocárdio/diagnóstico , Eletrocardiografia , Medição de Risco
7.
Heart Lung ; 61: 107-113, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37247537

RESUMO

BACKGROUND: Patients with known heart failure (HF) present to emergency departments (ED) with a plethora of symptoms. Although symptom clusters have been suggested as prognostic features, accurately triaging HF patients is a longstanding challenge. OBJECTIVES: We sought to use machine learning to identify subtle phenotypes of patient symptoms and evaluate their diagnostic and prognostic value among HF patients seeking emergency care. METHODS: This was a secondary analysis of a prospective cohort study of consecutive patients seen in the ED for chest pain or equivalent symptoms. Independent reviewers extracted clinical data from charts, including nine categories of subjective symptoms reported during initial evaluation. The diagnostic outcome was acute HF exacerbation and prognostic outcome was 30-day major adverse cardiac events (MACE). Outcomes were adjudicated by two independent reviewers. K-means clustering was used to derive latent patient symptom clusters, and their associations with outcomes were assessed using multivariate logistic regression. RESULTS: Sample included 438 patients (age 65±14 years; 45% female, 49% Black, 18% HF exacerbation, 32% MACE). K-means clustering identified three presentation phenotypes: patients with dyspnea only (Cluster A, 40%); patients with indigestion, with or without dyspnea (Cluster B, 23%); patients with neither dyspnea nor indigestion (Cluster C, 37%). Compared to Cluster C, indigestion was a significant predictor of acute HF exacerbation (OR=1.8, 95%CI=1.0-3.4) and 30-day MACE (OR=1.8, 95%CI=1.0-3.1), independent of age, sex, race, and other comorbidities. CONCLUSION: Indigestion symptoms in patients with known HF signify excess risk of adverse events, suggesting that these patients should be triaged as high-risk during initial ED evaluation.


Assuntos
Dispepsia , Insuficiência Cardíaca , Humanos , Feminino , Masculino , Estudos Prospectivos , Síndrome , Aprendizado de Máquina não Supervisionado , Dispepsia/complicações , Serviço Hospitalar de Emergência , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/diagnóstico , Dispneia/etiologia , Dispneia/diagnóstico
9.
Ann Emerg Med ; 81(1): 57-69, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36253296

RESUMO

STUDY OBJECTIVE: Ischemic electrocardiogram (ECG) changes are subtle and transient in patients with suspected non-ST-segment elevation (NSTE)-acute coronary syndrome. However, the out-of-hospital ECG is not routinely used during subsequent evaluation at the emergency department. Therefore, we sought to compare the diagnostic performance of out-of-hospital and ED ECG and evaluate the incremental gain of artificial intelligence-augmented ECG analysis. METHODS: This prospective observational cohort study recruited patients with out-of-hospital chest pain. We retrieved out-of-hospital-ECG obtained by paramedics in the field and the first ED ECG obtained by nurses during inhospital evaluation. Two independent and blinded reviewers interpreted ECG dyads in mixed order per practice recommendations. Using 179 morphological ECG features, we trained, cross-validated, and tested a random forest classifier to augment non ST-elevation acute coronary syndrome (NSTE-ACS) diagnosis. RESULTS: Our sample included 2,122 patients (age 59 [16]; 53% women; 44% Black, 13.5% confirmed acute coronary syndrome). The rate of diagnostic ST elevation and ST depression were 5.9% and 16.2% on out-of-hospital-ECG and 6.1% and 12.4% on ED ECG, with ∼40% of changes seen on out-of-hospital-ECG persisting and ∼60% resolving. Using expert interpretation of out-of-hospital-ECG alone gave poor baseline performance with area under the receiver operating characteristic (AUC), sensitivity, and negative predictive values of 0.69, 0.50, and 0.92. Using expert interpretation of serial ECG changes enhanced this performance (AUC 0.80, sensitivity 0.61, and specificity 0.93). Interestingly, augmenting the out-of-hospital-ECG alone with artificial intelligence algorithms boosted its performance (AUC 0.83, sensitivity 0.75, and specificity 0.95), yielding a net reclassification improvement of 29.5% against expert ECG interpretation. CONCLUSION: In this study, 60% of diagnostic ST changes resolved prior to hospital arrival, making the ED ECG suboptimal for the inhospital evaluation of NSTE-ACS. Using serial ECG changes or incorporating artificial intelligence-augmented analyses would allow correctly reclassifying one in 4 patients with suspected NSTE-ACS.


Assuntos
Síndrome Coronariana Aguda , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Síndrome Coronariana Aguda/diagnóstico , Inteligência Artificial , Estudos Prospectivos , Eletrocardiografia , Aprendizado de Máquina , Hospitais
11.
J Electrocardiol ; 73: 157-161, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35853754

RESUMO

In this commentary paper, we discuss the use of the electrocardiogram to help clinicians make diagnostic and patient referral decisions in acute care settings. The paper discusses the factors that are likely to contribute to the variability and noise in the clinical decision making process for catheterization lab activation. These factors include the variable competence in reading ECGs, the intra/inter rater reliability, the lack of standard ECG training, the various ECG machine and filter settings, cognitive biases (such as automation bias which is the tendency to agree with the computer-aided diagnosis or AI diagnosis), the order of the information being received, tiredness or decision fatigue as well as ECG artefacts such as the signal noise or lead misplacement. We also discuss potential research questions and tools that could be used to mitigate this 'noise' and improve the quality of ECG based decision making.


Assuntos
Diagnóstico por Computador , Eletrocardiografia , Tomada de Decisão Clínica , Tomada de Decisões , Humanos , Reprodutibilidade dos Testes
13.
Heart Rhythm ; 19(7): 1192-1201, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35276320

RESUMO

The electrocardiogram (ECG) records the electrical activity in the heart in real time, providing an important opportunity to detecting various cardiac pathologies. The 12-lead ECG currently serves as the "standard" ECG acquisition technique for diagnostic purposes for many cardiac pathologies other than arrhythmias. However, the technical aspects of acquiring a 12-lead ECG are not easy. and its usage currently is restricted to trained medical personnel, which limits the scope of its usefulness. Remote and wearable ECG devices have attempted to bridge this gap by enabling patients to take their own ECG using a simplified method at the expense of a reduced number of leads, usually a single-lead ECG. In this review, we summarize the studies that investigated the use of remote ECG devices and their clinical utility in diagnosing cardiac pathologies. Eligible studies discussed Food and Drug Administration-cleared, commercially available devices that were validated in an adult population. We summarize technical logistics of signal quality and device reliability, dimensional and functional features, and diagnostic value. Our synthesis shows that reduced-set ECG wearables have huge potential for long-term monitoring, particularly if paired with real-time notification techniques. Such capabilities make them primarily useful for abnormal rhythm detection, and there is sufficient evidence that a remote ECG device can be superior to the traditional 12-lead ECG in diagnosing specific arrhythmias such as atrial fibrillation. However, this review identifies important challenges faced by this technology and highlights the limited availability of clinical research examining their usefulness.


Assuntos
Fibrilação Atrial , Dispositivos Eletrônicos Vestíveis , Adulto , Fibrilação Atrial/diagnóstico , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial/métodos , Humanos , Reprodutibilidade dos Testes
15.
Eur Heart J Digit Health ; 3(2): 125-140, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36713011

RESUMO

Developing functional machine learning (ML)-based models to address unmet clinical needs requires unique considerations for optimal clinical utility. Recent debates about the rigours, transparency, explainability, and reproducibility of ML models, terms which are defined in this article, have raised concerns about their clinical utility and suitability for integration in current evidence-based practice paradigms. This featured article focuses on increasing the literacy of ML among clinicians by providing them with the knowledge and tools needed to understand and critically appraise clinical studies focused on ML. A checklist is provided for evaluating the rigour and reproducibility of the four ML building blocks: data curation, feature engineering, model development, and clinical deployment. Checklists like this are important for quality assurance and to ensure that ML studies are rigourously and confidently reviewed by clinicians and are guided by domain knowledge of the setting in which the findings will be applied. Bridging the gap between clinicians, healthcare scientists, and ML engineers can address many shortcomings and pitfalls of ML-based solutions and their potential deployment at the bedside.

17.
Cardiol Young ; 31(11): 1770-1780, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34725005

RESUMO

Machine learning uses historical data to make predictions about new data. It has been frequently applied in healthcare to optimise diagnostic classification through discovery of hidden patterns in data that may not be obvious to clinicians. Congenital Heart Defect (CHD) machine learning research entails one of the most promising clinical applications, in which timely and accurate diagnosis is essential. The objective of this scoping review is to summarise the application and clinical utility of machine learning techniques used in paediatric cardiology research, specifically focusing on approaches aiming to optimise diagnosis and assessment of underlying CHD. Out of 50 full-text articles identified between 2015 and 2021, 40% focused on optimising the diagnosis and assessment of CHD. Deep learning and support vector machine were the most commonly used algorithms, accounting for an overall diagnostic accuracy > 0.80. Clinical applications primarily focused on the classification of auscultatory heart sounds, transthoracic echocardiograms, and cardiac MRIs. The range of these applications and directions of future research are discussed in this scoping review.


Assuntos
Cardiopatias Congênitas , Aprendizado de Máquina , Algoritmos , Criança , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Máquina de Vetores de Suporte
18.
J Electrocardiol ; 69S: 7-11, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34548191

RESUMO

Automated interpretation of the 12-lead ECG has remained an underpinning interest in decades of research that has seen a diversity of computing applications in cardiology. The application of computers in cardiology began in the 1960s with early research focusing on the conversion of analogue ECG signals (voltages) to digital samples. Alongside this, software techniques that automated the extraction of wave measurements and provided basic diagnostic statements, began to emerge. In the years since then there have been many significant milestones which include the widespread commercialisation of 12-lead ECG interpretation software, associated clinical utility and the development of the related regulatory frameworks to promote standardised development. In the past few years, the research community has seen a significant rejuvenation in the development of ECG interpretation programs. This is evident in the research literature where a large number of studies have emerged tackling a variety of automated ECG interpretation problems. This is largely due to two factors. Specifically, the technical advances, both software and hardware, that have facilitated the broad adoption of modern artificial intelligence (AI) techniques, and, the increasing availability of large datasets that support modern AI approaches. In this article we provide a very high-level overview of the operation of and approach to the development of early 12-lead ECG interpretation programs and we contrast this to the approaches that are now seen in emerging AI approaches. Our overview is mainly focused on highlighting differences in how input data are handled prior to generation of the diagnostic statement.


Assuntos
Cardiologia , Aprendizado Profundo , Algoritmos , Inteligência Artificial , Eletrocardiografia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...