1.
Med Phys ; 39(7Part2): 4625, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28516558

RESUMO

INTRODUCTION: An online Magnetic Resonance guided Radiation Therapy (MRgRT) system is under development. The system is comprised of an MRI with the capability of travel between and into HDR brachytherapy and external beam radiation therapy vaults. The system will provide on-line MR images immediately prior to radiation therapy. The MR images will be registered to a planning image and used for image guidance. With the intention of system safety we have performed a failure modes and effects analysis. METHODS: A process tree of the facility function was developed. Using the process tree as well as an initial design of the facility as guidelines possible failure modes were identified, for each of these failure modes root causes were identified. For each possible failure the assignment of severity, detectability and occurrence scores was performed. Finally suggestions were developed to reduce the possibility of an event. RESULTS/DISCUSSION: The process tree consists of nine main inputs and each of these main inputs consisted of 5 - 10 sub inputs and tertiary inputs were also defined. The process tree ensures that the overall safety of the system has been considered. Several possible failure modes were identified and were relevant to the design, construction, commissioning and operating phases of the facility. The utility of the analysis can be seen in that it has spawned projects prior to installation and has lead to suggestions in the design of the facility.

2.
Phys Med Biol ; 51(12): 3251-67, 2006 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-16757875

RESUMO

We present treatment planning methods based on four-dimensional computed tomography (4D-CT) to incorporate tumour motion using (1) a static field and (2) a dynamic field. Static 4D fields are determined to include the target in all breathing phases, whereas dynamic 4D fields are determined to follow the shape of the tumour assessed from 4D-CT images with a dynamic weighting factor. The weighting factor selection depends on the reliability of patient breathing and limitations of the delivery system. The static 4D method is compared with our standard protocol for gross tumour volume (GTV) coverage, mean lung dose and V20. It was found that the GTV delineated on helical CT without incorporating breathing motion does not adequately represent the target compared to the GTV delineated from 4D-CT. Dosimetric analysis indicates that the static 4D-CT based technique results in a reduction of the mean lung dose compared with the standard protocol. Measurements on a moving phantom and simulations indicated that 4D radiotherapy (4D-RT) synchronized with respiration-induced motion further reduces mean lung dose and V20, and may allow safe application of dose escalation and CRT/IMRT. The motions of the chest cavity, tumour and thoracic structures of 24 lung cancer patients are also analysed.


Assuntos
Imageamento Tridimensional/métodos , Neoplasias Pulmonares/radioterapia , Movimento , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Tomografia Computadorizada por Raios X/métodos , Artefatos , Carga Corporal (Radioterapia) , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Imagens de Fantasmas , Radiometria/métodos , Dosagem Radioterapêutica , Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/instrumentação
3.
Radiother Oncol ; 61(2): 127-33, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11690677

RESUMO

PURPOSE: To evaluate treatment errors from set-up and inter-fraction prostatic motion with port films and implanted prostate fiducial markers during conformal radiotherapy for localized prostate cancer. METHODS: Errors from isocentre positioning and inter-fraction prostate motion were investigated in 13 men treated with escalated dose conformal radiotherapy for localized prostate cancer. To limit the effect of inter-fraction prostate motion, patients were planned and treated with an empty rectum and a comfortably full bladder, and were instructed regarding dietary management, fluid intake and laxative use. Field placement was determined and corrected with daily on-line portal imaging. A lateral portal film was taken three times weekly over the course of therapy. From these films, random and systematic placement errors were measured by matching corresponding bony landmarks to the simulator film. Superior-inferior and anterior-posterior prostate motion was measured from the displacement of three gold pins implanted into the prostate before planning. A planning target volume (PTV) was derived to account for the measured prostate motion and field placement errors. RESULTS: From 272 port films the random and systematic isocentre positioning error was 2.2 mm (range 0.2-7.3 mm) and 1.4 mm (range 0.2-3.3 mm), respectively. Prostate motion was largest at the base compared to the apex. Base: anterior, standard deviation (SD) 2.9 mm; superior, SD 2.1 mm. Apex: anterior, SD 2.1 mm; superior, SD 2.1 mm. The margin of PTV required to give a 99% probability of the gland remaining within the 95% isodose line during the course of therapy is superior 5.8 mm, and inferior 5.6 mm. In the anterior and posterior direction, this margin is 7.2 mm at the base, 6.5 mm at the mid-gland and 6.0 mm at the apex. CONCLUSIONS: Systematic set-up errors were small using real-time isocentre placement corrections. Patient instruction to help control variation in bladder and rectal distension during therapy may explain the observed small SD for prostate motion in this group of patients. Inter-fraction prostate motion remained the largest source of treatment error, and observed motion was greatest at the gland base. In the absence of real-time pre-treatment imaging of prostate position, sequential portal films of implanted prostatic markers should improve quality assurance by confirming organ position within the treatment field over the course of therapy.


Assuntos
Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional , Humanos , Masculino
4.
Int J Radiat Oncol Biol Phys ; 49(3): 869-84, 2001 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-11172971

RESUMO

PURPOSE: To use portal imaging to measure daily on-line setup error and off-line prostatic motion in patients treated with conformal radiotherapy to determine an optimum planning target volume (PTV) margin incorporating both setup error and organ motion. RESULTS: A total of 2549 portal images from 33 patients were acquired over the course of the study. Of these patients, 23 were analyzed for setup errors while the remaining 10 were analyzed for prostatic motion. Setup errors were characterized by standard deviations of 1.8 mm in the anterior-posterior (AP) direction and 1.4 mm in the superior-inferior (SI) direction. Displacements due to prostatic motion, with standard deviations of 5.8 mm AP and 3.3 mm SI, were found to be more significant than setup errors. CONCLUSIONS: Taking into account both setup errors and target organ motion, optimum PTV margins to ensure 95% coverage are 10.0 mm AP and 5.9 mm SI. The portal imaging protocol established in this study allows radiation therapists to accept or adjust a treatment setup based upon daily on-line image matching results. The successful localization of radiopaque fiducial markers on a significant number of portal images acquired in the study gives hope that more accurate on-line targeting verification may soon be possible through the visualization of the prostate itself as opposed to the surrounding bony structures of the pelvis.


Assuntos
Carcinoma/radioterapia , Movimento , Neoplasias da Próstata/radioterapia , Radioterapia Conformacional/métodos , Carcinoma/diagnóstico por imagem , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Radiografia , Dosagem Radioterapêutica , Reprodutibilidade dos Testes
5.
Radiother Oncol ; 47(3): 277-84, 1998 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9681891

RESUMO

BACKGROUND AND PURPOSE: It is necessary to include the entire prostate in the high dose treatment volume when planning radical radiation for patients with prostate cancer. We prospectively compared magnetic resonance imaging (MRI) to computed tomography (CT) and urethrography as means of localizing the prostatic apex. MATERIALS AND METHODS: Thirty patients with clinically localized prostate cancer had a sagittal T2-weighted MRI scan and a conventional axial CT scan performed in the treatment position prior to the start of radiotherapy. Twenty of these patients had a static retrograde urethrogram performed at simulation. The position of the MRI and CT apices were localized independently by two radiation oncologists. In addition, the MRI apex was localized independently by a diagnostic radiologist. The urethrogram apex, defined as the tip of the urethral contrast cone, was easily identified and was therefore localized by only one observer. RESULTS: There was good interobserver agreement in the position of the MRI apex. Interobserver agreement was significantly better with MRI than with CT. There were no systematic differences in the position of the MRI and CT apices. However, the MRI apex was located significantly above and behind the urethrogram apex. There was poor correlation between MRI and CT and between MRI and urethrogram in the height of the apex above the ischial tuberosities. There was 83% agreement between MRI and CT and 80% agreement between MRI and urethrogram in the identification of patients with a low-lying apex. The apex, as determined by MRI, was <2 cm above the ischial tuberosities and therefore potentially under-treated in 17% of the patients. CONCLUSIONS: MRI is superior to CT and urethrography for localization of the prostatic apex. All patients undergoing radiotherapy for prostate cancer should have localization of the apex using MRI or a technique of equal precision to assure adequate dose delivery to the entire prostate and to minimize the unnecessary irradiation of normal tissues.


Assuntos
Adenocarcinoma/diagnóstico , Imageamento por Ressonância Magnética , Próstata/patologia , Neoplasias da Próstata/diagnóstico , Tomografia Computadorizada por Raios X , Urografia , Adenocarcinoma/radioterapia , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Reprodutibilidade dos Testes , Glândulas Seminais/diagnóstico por imagem , Glândulas Seminais/patologia , Uretra/diagnóstico por imagem
6.
Med Phys ; 22(10): 1675-83, 1995 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8551994

RESUMO

A common problem with low-energy electron beams (< 15 MeV) is their low surface dose when the incident electrons are monodirectional. This makes it difficult to deliver a uniform dose to tumor with any precision, limiting the clinical usefulness of such beams. A practical method is presented for greatly increasing the tissue depth enclosed by the 95% isodose region, while delivering the entire dose in a single uninterrupted treatment. Beam modification is achieved by placing a wire mesh of high atomic number (Z) on the treatment surface throughout the treatment. Electron beams of energies 6, 9, and 13 MeV are modified to produce a near uniform dose from the surface to the original depth of maximum, approximately doubling the depth enclosed by the 95% isodose. These beams have a step-function-like depth dose and can be arranged to deliver a constant dose to tumor located at varying depths while simultaneously sparing deeper tissues which are also located at varying depths. A single mesh design was found to be suitable for all energies.


Assuntos
Neoplasias/radioterapia , Imagens de Fantasmas , Radioterapia/instrumentação , Elétrons , Humanos , Matemática , Radioterapia/métodos , Dosagem Radioterapêutica