Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
J Digit Imaging ; 35(3): 396-407, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35106674

RESUMO

The benefits of structured reporting (SR) in radiology are well-known and have been widely described. However, there are limitations that must be overcome. Radiologists may be reluctant to change the conventional way of reporting. Error rates could potentially increase if SR is used improperly. Interruption of the visual search pattern by keeping the eyes focused on the report rather than the images may increase reporting time. Templates that include unnecessary or irrelevant information may undermine the consistency of the report. Last, the lack of support for multiple languages may hamper the adaptation of the report to the target audience. This work aims to mitigate these limitations with a web-based structured reporting system based on templates. By including field validators and logical rules, the system avoids reporting mistakes and allows to automatically calculate values and radiological qualitative scores. The system can manage quantitative information from imaging biomarkers, combining this with qualitative radiological information usually present in the structured report. It manages SR templates as plugins (IHE MRRT compliant and compatible with RSNA's Radreport templates), ensures a seamless integration with PACS/RIS systems, and adapts the report to the target audience by means of natural language extracts generated in multiple languages. We describe a use case of SR template for prostate cancer including PI-RADS 2.1 scoring system and imaging biomarkers. For the time being, the system comprises 24 SR templates and provides service in 37 hospitals and healthcare institutions, endorsing the success of this contribution to mitigate some of the limitations of the SR.


Assuntos
Neoplasias da Próstata , Sistemas de Informação em Radiologia , Radiologia , Biomarcadores , Humanos , Imageamento por Ressonância Magnética , Masculino
2.
Clin Radiol ; 75(11): 880.e5-880.e12, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32888653

RESUMO

AIM: To compare the performance of multi-echo chemical-shift-encoded (MECSE) magnetic resonance imaging (MRI) proton density fat fraction (PDFF) estimation, considering three different fat frequency peak combinations, for the quantification of steatosis in patients with non-alcoholic fatty liver disease (NAFLD). MATERIALS AND METHODS: The present study was a prospective cross-sectional research of 121 patients with metabolic syndrome and evidence of hepatic steatosis on ultrasound, who underwent a 3 T MRI examination. All patients were studied with a multifrequency MECSE sequence. The PDFF was calculated using six peaks (MECSEp123456), three peaks (MECSEp456), and a single peak (MECSEp5) model. The two simpler fat peak models were compared to the six peaks model, which was considered the reference standard. Linearity was evaluated using linear regression while agreement was described using Bland-Altman analysis. RESULTS: The mean age was 47 (±9) years and BMI was 29.9 (±2.9) kg/m2. Steatosis distribution was 15%/31%/54% (S1/S2/S3, respectively). Compared to MECSEp123456, both models provided linear PDFF measurements (R2= 0.99 and 0.97, MECSEp456 and MECSEp5 respectively). Regression slope (0.92; p<0.001) and mean Bland-Altman bias (-1.5%; 95% limits of agreement: -3.19%, 0.22%) indicated minimal underestimation by using PDFF-MECSEp456. Nonetheless, mean differences in PDFF estimations varied from -1.5% (MECSEp456,p=0.006) to -2.2% (MECSEp5,p<0.001) when compared to full six fat frequencies model. CONCLUSION: Although simpler spectral fat MECSE analysis shows a linear relationship with the standard six peaks model, their variation in estimated PDFF values introduces a low but clinically significant bias in fat quantification and steatosis grading in NAFLD patients.


Assuntos
Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Tecido Adiposo/diagnóstico por imagem , Tecido Adiposo/patologia , Estudos Transversais , Fígado Gorduroso/diagnóstico por imagem , Fígado Gorduroso/patologia , Feminino , Humanos , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/patologia , Estudos Prospectivos
3.
Abdom Radiol (NY) ; 45(11): 3557-3568, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32857259

RESUMO

Magnetic resonance (MR) identification and grading of subjects with liver fibrosis and inflammation represents a clinical challenge. MR elastography plays a well-defined role in fibrosis estimation, but its use is not widely available in clinical settings. Given that liver MR is becoming the reference standard for fat and iron quantitation, there is a need to clarify whether there is any role for MR imaging in the concomitant evaluation of fibrosis and inflammation in this setting. This review summarizes the diagnostic estimations of different MR imaging parameters obtained from conventional non-contrast-enhanced multiple b values diffusion-weighted acquisitions, variable flip angles T1 relaxation maps and STIR images. Although some derived parameters have shown a significant correlation to histological scores, a small magnitude of effect with wide overlap across severity grades is the rule. Contrary to fat and iron quantification, the low precision and reproducibility of MR imaging metrics limits its clinical relevance in fibrosis and inflammation assessment. In a sequential clinical approach combining different methodologies, MR imaging has no applicability for ruling-out and low accuracy for ruling-in advanced fibrosis. Thereby, MR elastography remains as the only image method with high diagnostic accuracy for the detection of advanced fibrosis. Until date, inflammation remains in a gray zone where biopsy cannot be replaced, and further investigations are needed. The present review offers an in-depth discuss of the MR imaging diagnostic performance for the evaluation of liver fibrosis and inflammation, highlighting the need for scientific improvements.


Assuntos
Técnicas de Imagem por Elasticidade , Cirrose Hepática , Humanos , Inflamação/diagnóstico por imagem , Inflamação/patologia , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes
4.
Radiología (Madr., Ed. impr.) ; 62(3): 222-228, mayo-jun. 2020. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-194220

RESUMO

OBJETIVO: Comparar la esteatosis pancreática y hepática mediante la determinación de la fracción de grasa por densidad protónica (FGDP) por resonancia magnética (RM) en pacientes con enfermedad hepática crónica. MATERIAL Y MÉTODOS: Estudio transversal de 46 pacientes adultos con biopsia hepática por hepatitis viral crónica (n=19) o por enfermedad hepática crónica no alcohólica (EHNA) (n=27). La biopsia de hígado se utilizó como referencia para la gradación de la esteatosis hepática. Todos los pacientes se sometieron a valoración clínica y estudio de RM con una secuencia eco de gradiente codificado por desplazamiento químico con múltiples ecos (MECSE) para la cuantificación de la FGDP en hígado y páncreas. Se utilizó el coeficiente de correlación de Spearman para calcular el grado de asociación entre la FGDP hepática y los grados de esteatosis por biopsia, y entre la FGDP pancreática y la afectación hepática (grados de esteatosis y FGDP). El T-test se realizó para comparar variables continuas/ordinales en los grupos de hepatitis viral crónica y EHNA. Las variables categóricas se evaluaron mediante la prueba de gi. RESULTADOS: Se observó una correlación significativa entre la FGDP hepática y los grados de esteatosis (Rs=0,875, p < 0,001). También se evidenció una correlación positiva entre la FGDP del páncreas y la afectación hepática: grados de esteatosis (Rs=0,573, p < 0,001) y FGDP (Rs=0,536, p < 0,001). En el subgrupo de pacientes con EHNA crónica se mantuvo la correlación positiva significativa entre la FGDP pancreática y hepática (Rs=0,632, p < 0,001) y con la esteatosis hepática (Rs=0,608, p < 0,001). Estas relaciones se perdieron en el subgrupo de pacientes con hepatitis viral. CONCLUSIÓN: El depósito de grasa pancreática se correlaciona con la esteatosis hepática en pacientes con EHNA crónica. Esta relación se pierde en los pacientes con hepatitis viral crónica


AIM: To compare pancreatic and hepatic steatosis quantified by proton density fat fraction (PDFF) on magnetic resonance imaging (MRI) in patients with chronic liver disease. MATERIAL AND METHODS: This cross-sectional study included 46 adult patients who underwent liver biopsy for chronic viral hepatitis (n=19) or other chronic non-alcoholic liver diseases (NALD) (n=27). Liver biopsy was used as the gold standard for diagnosing and grading hepatic steatosis. All patients underwent clinical evaluation and MRI with a multi-echo chemical shift-encoded (MECSE) gradient-echo sequence for liver and pancreas PDFF quantification. We used Spearman's correlation coefficient to determine the degree of association between hepatic PDFF and steatosis grade, and between pancreatic PDFF and steatosis grade and hepatic PDFF. To compare the chronic viral hepatitis group and the NALD group, we used t-tests for continuous or ordinal variables and chi-square tests for categorical variables. RESULTS: Hepatic PDFF measurements correlated with steatosis grades (RS=0.875, p < 0.001). Pancreatic PDFF correlated with hepatic steatosis grades (RS=0.573, p < 0.001) and hepatic PDFF measurements (RS=0.536, p < 0.001). In the subgroup of patients with chronic NALD, the correlations remained significant between pancreatic PDFF and hepatic PDFF (RS=0.632, p < 0.001) and between pancreatic PDFF and liver steatosis (RS=0.608, p < 0.001); however, in the subgroup of patients with viral hepatitis these correlations were no longer significant. CONCLUSION: Pancreatic fat deposition correlates with hepatic steatosis in patients with chronic NALD, but not in those with chronic viral hepatitis


Assuntos
Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Fígado Gorduroso/diagnóstico por imagem , Hepatopatias/diagnóstico por imagem , Espectroscopia de Ressonância Magnética , Imageamento por Ressonância Magnética , Biópsia , Fígado/diagnóstico por imagem , Fígado/patologia , Testes de Função Hepática/métodos
5.
Radiologia (Engl Ed) ; 62(3): 222-228, 2020.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31932016

RESUMO

AIM: To compare pancreatic and hepatic steatosis quantified by proton density fat fraction (PDFF) on magnetic resonance imaging (MRI) in patients with chronic liver disease. MATERIAL AND METHODS: This cross-sectional study included 46 adult patients who underwent liver biopsy for chronic viral hepatitis (n=19) or other chronic non-alcoholic liver diseases (NALD) (n=27). Liver biopsy was used as the gold standard for diagnosing and grading hepatic steatosis. All patients underwent clinical evaluation and MRI with a multi-echo chemical shift-encoded (MECSE) gradient-echo sequence for liver and pancreas PDFF quantification. We used Spearman's correlation coefficient to determine the degree of association between hepatic PDFF and steatosis grade, and between pancreatic PDFF and steatosis grade and hepatic PDFF. To compare the chronic viral hepatitis group and the NALD group, we used t-tests for continuous or ordinal variables and chi-square tests for categorical variables. RESULTS: Hepatic PDFF measurements correlated with steatosis grades (RS=0.875, p<0.001). Pancreatic PDFF correlated with hepatic steatosis grades (RS=0.573, p<0.001) and hepatic PDFF measurements (RS=0.536, p<0.001). In the subgroup of patients with chronic NALD, the correlations remained significant between pancreatic PDFF and hepatic PDFF (RS=0.632, p<0.001) and between pancreatic PDFF and liver steatosis (RS=0.608, p<0.001); however, in the subgroup of patients with viral hepatitis these correlations were no longer significant. CONCLUSION: Pancreatic fat deposition correlates with hepatic steatosis in patients with chronic NALD, but not in those with chronic viral hepatitis.


Assuntos
Fígado Gorduroso/diagnóstico por imagem , Lipomatose/diagnóstico por imagem , Hepatopatias/complicações , Imageamento por Ressonância Magnética/métodos , Pancreatopatias/diagnóstico por imagem , Adulto , Idoso , Biópsia/normas , Distribuição de Qui-Quadrado , Doença Crônica , Estudos Transversais , Fígado Gorduroso/patologia , Feminino , Hepatite Viral Humana/diagnóstico por imagem , Humanos , Lipomatose/patologia , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Pancreatopatias/patologia , Estatísticas não Paramétricas , Adulto Jovem
6.
Clin Radiol ; 75(1): 38-45, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31521323

RESUMO

AIM: To test the diagnostic performance of a deep learning-based system for the detection of clinically significant pulmonary nodules/masses on chest radiographs. MATERIALS AND METHODS: Using a retrospective study of 100 patients (47 with clinically significant pulmonary nodules/masses and 53 control subjects without pulmonary nodules), two radiologists verified clinically significantly pulmonary nodules/masses according to chest computed tomography (CT) findings. A computer-aided diagnosis (CAD) software using a deep-learning approach was used to detect pulmonary nodules/masses to determine the diagnostic performance in four algorithms (heat map, abnormal probability, nodule probability, and mass probability). RESULTS: A total of 100 cases were included in the analysis. Among the four algorithms, mass algorithm could achieve a 76.6% sensitivity (36/47, 11 false negative) and 88.68% specificity (47/53, six false-positive) in the detection of pulmonary nodules/masses at the optimal probability score cut-off of 0.2884. Compared to the other three algorithms, mass probability algorithm had best predictive ability for pulmonary nodule/mass detection at the optimal probability score cut-off of 0.2884 (AUCMass: 0.916 versus AUCHeat map: 0.682, p<0.001; AUCMass: 0.916 versus AUCAbnormal: 0.810, p=0.002; AUCMass: 0.916 versus AUCNodule: 0.813, p=0.014). CONCLUSION: In conclusion, the deep-learning based computer-aided diagnosis system will likely play a vital role in the early detection and diagnosis of pulmonary nodules/masses on chest radiographs. In future applications, these algorithms could support triage workflow via double reading to improve sensitivity and specificity during the diagnostic process.


Assuntos
Aprendizado Profundo , Neoplasias Pulmonares/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Radiografia Torácica/métodos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Diagnóstico por Computador/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Melhoria de Qualidade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Sensibilidade e Especificidade , Software , Taiwan
7.
Diabetes Metab ; 45(5): 473-479, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30660761

RESUMO

AIM: The association of non-alcoholic fatty liver disease (NAFLD) with insulin resistance (IR) is well established, yet little is known of their possible relationship with intrahepatic iron and serum tumour necrosis factor (TNF)-α concentrations in adults without diabetes. Thus, this study looked at the relationship of intrahepatic iron and serum TNF-α with intrahepatic triglycerides and IR in non-diabetic adults. METHODS: In this cross-sectional study of 104 healthy non-diabetic Caucasians, a quantitative magnetic resonance (MR) imaging T2 gradient-echo technique was used to measure hepatic iron, with 1H-MR spectroscopy used to measure hepatic triglycerides. HOMA-IR was calculated to determine IR. RESULTS: The prevalence of hepatic iron overload (HIOL) was 26.6% in individuals with NAFLD vs. 0% in those without. IR was present in 87.5% of subjects with both NAFLD and HIOL, in 45.4% of those with NAFLD but not HIOL, and in 4.5% of those with neither. HOMA-IR was positively correlated with hepatic triglycerides (r = 0.56, P < 0.001) and hepatic iron (r = 0.52, P < 0.001), whereas serum TNF-α concentrations correlated with intrahepatic triglyceride levels (r = 0.28, P < 0.04), but not with intrahepatic iron. Hepatic triglycerides, serum TNF-α and age were the only significant determinants of IR in regression analyses. CONCLUSION: IR is closely associated with intrahepatic triglycerides and, to a lesser extent, intrahepatic iron, with some interplay between them. High serum TNF-α concentrations may contribute to the association between NAFLD and IR, while increased hepatic triglycerides appear to be a determinant of the development of HIOL in non-diabetic subjects without haemochromatosis.


Assuntos
Resistência à Insulina/fisiologia , Ferro/análise , Fígado/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/sangue , Fator de Necrose Tumoral alfa/sangue , Adulto , Fatores Etários , Idoso , Estudos Transversais , Feminino , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Triglicerídeos/sangue
8.
Radiología (Madr., Ed. impr.) ; 60(supl.1): 43-52, mayo 2018. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-175337

RESUMO

En la actualidad, tanto las imágenes como los datos que generan y los informes que se emiten son digitales y constituyen una fuente de datos fiable. Los informes pueden clasificarse, en función de su contenido, formato y tipo de datos, como organizado (texto libre en lenguaje natural), predefinido (con plantillas y guías construidas con campos previamente determinados con lenguaje natural tipo BI-RADS y PI-RADS) y estructurado (con desplegables en forma de preguntas, con diversas posibles respuestas, previamente pactadas en el equipo multidisciplinario, con léxicos estandarizados y estructurado como base de datos, con información trazable y explotable mediante herramientas estadísticas y de minería de datos). Este informe estructurado, compatible con MRRT (Management of Radiology Report Templates), permite incorporar información cuantitativa relacionada con el análisis digital de los datos de las imágenes adquiridas para describir, mediante radiómica (características y parámetros), las propiedades y el comportamiento de los tejidos con exactitud y veracidad. En conclusión, los datos digitales estructurados (imágenes, texto, mediciones, radiómica, biomarcadores de imagen) deben integrarse en un informe informatizado que permita su indexación en grandes repositorios. Estos bancos de datos radiológicos son fundamentales en la medicina personalizada para explotar la información sanitaria, fenotipificar las lesiones y enfermedades, y extraer conclusiones


Nowadays, the images and information generated in imaging tests, as well as the reports that are issued, are digital and represent a reliable source of data. Reports can be classified according to their content and to the type of information they include into three main types: organized (free text in natural language), predefined (with templates and guidelines elaborated with previously determined natural language like that used in BI-RADS and PI-RADS), or structured (with drop-down menus displaying questions with various possible answers that have been agreed on with the rest of the multidisciplinary team, which use standardized lexicons and are structured in the form of a database with data that can be traced and exploited with statistical tools and data mining). The structured report, compatible with Management of Radiology Report Templates (MRRT), makes it possible to incorporate quantitative information related with the digital analysis of the data from the acquired images to accurately and precisely describe the properties and behavior of tissues by means of radiomics (characteristics and parameters). In conclusion, structured digital information (images, text, measurements, radiomic features, and imaging biomarkers) should be integrated into computerized reports so that they can be indexed in large repositories. Radiologic databanks are fundamental for exploiting health information, phenotyping lesions and diseases, and extracting conclusions in personalized medicine


Assuntos
Humanos , Prontuários Médicos/normas , Neoplasias/diagnóstico por imagem , Comunicação em Saúde/métodos , Radiografia/normas , Sistemas de Informação em Radiologia/organização & administração , Medicina de Precisão/tendências , Biomarcadores/análise , Biomarcadores Tumorais/análise , Radiogenética/tendências
9.
Clin Radiol ; 73(2): 215.e1-215.e9, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28863932

RESUMO

AIM: To investigate iron loading within the liver, pancreas, spleen, and bone marrow using magnetic resonance imaging (MRI) transverse relaxation rate (R2*), in patients with diffuse liver diseases; to evaluate the relationships between iron accumulation in these tissue compartments; and to assess the association between tissue iron overload and the pattern of hepatic cellular iron distribution (hepatocytes versus Kupffer cells). MATERIAL AND METHODS: Fifty-six patients with diffuse liver diseases had MRI-derived R2* values, using a multi-echo chemical-shift encoded MRI sequence, of the liver, pancreas, spleen, and vertebral bone marrow. All patients had liver biopsy samples scored for hepatic iron grading (0-4) and iron cellular distribution (within hepatocytes only or within both hepatocytes and Kupffer cells). RESULTS: Liver R2* increased with histological iron grade (RS=0.58, p<0.001) and correlated with spleen (RS=0.71, p<0.001) and bone marrow R2* (RS=0.66, p<0.001), but not with pancreatic R2* (RS=0.22, p=0.096). Splenic and bone marrow R2* values were also correlated (RS=0.72, p<0.001). Patients with iron inside Kupffer cells had the highest R2* in liver, spleen and bone marrow. CONCLUSIONS: Patients with chronic diffuse liver diseases have concomitant hepatic, splenic, and bone marrow iron loading. The highest hepatic iron scores and iron inside Kupffer cells were associated with the highest splenic and bone marrow deposits, suggesting systemic iron accumulation in the mononuclear phagocytic system.


Assuntos
Medula Óssea/metabolismo , Sobrecarga de Ferro , Hepatopatias/metabolismo , Fígado/metabolismo , Imageamento por Ressonância Magnética/métodos , Baço/metabolismo , Medula Óssea/diagnóstico por imagem , Doença Crônica , Estudos de Avaliação como Assunto , Humanos , Ferro/metabolismo , Fígado/diagnóstico por imagem , Hepatopatias/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Pâncreas/metabolismo , Estudos Prospectivos , Baço/diagnóstico por imagem
10.
Int J Obes (Lond) ; 41(11): 1627-1635, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28684860

RESUMO

BACKGROUND/OBJECTIVES: Growing evidence implicates neuroinflammation in the pathogenesis of diet-induced obesity and cognitive dysfunction in rodent models. Obesity is associated with reduced white matter integrity and cognitive decline. Circulating lipopolysaccharide binding protein (LBP) concentration is known to be increased in patients with obesity. Here, we aimed to evaluate whether circulating LBP is associated longitudinally with white matter structure and cognitive performance according to obesity status. SUBJECTS/METHODS: This longitudinal study analyzed circulating LBP (ELISA), DTI-metrics (axial diffusivity (L1), fractional anisotropy (FA) and radial diffusivity (RD)) in specific regions of the white matter of 24 consecutive middle-aged obese subjects (13 women) and 20 healthy volunteers (10 women) at baseline and two years later. Digit Span Test (DST) was used as a measure of working memory/short-term verbal memory. RESULTS: Circulating LBP concentration was associated with FA and L1 values of several white matter regions both at baseline and follow-up. The associations remained significant after controlling for age, BMI, fat mass and plasma high sensitivity C-reactive protein. Importantly, the increase in LBP over time impacted negatively on FA and L1 values and on DST performance. CONCLUSIONS: Circulating LBP associates with brain white matter integrity and working memory/short-term verbal memory in both obese and non-obese subjects.


Assuntos
Proteínas de Fase Aguda/metabolismo , Proteína C-Reativa/metabolismo , Proteínas de Transporte/metabolismo , Disfunção Cognitiva/fisiopatologia , Inflamação/fisiopatologia , Glicoproteínas de Membrana/metabolismo , Obesidade/fisiopatologia , Substância Branca/patologia , Adulto , Biomarcadores/metabolismo , Índice de Massa Corporal , Disfunção Cognitiva/etiologia , Disfunção Cognitiva/metabolismo , Imagem de Tensor de Difusão , Feminino , Humanos , Inflamação/complicações , Inflamação/metabolismo , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos , Obesidade/complicações , Obesidade/metabolismo , Valor Preditivo dos Testes
11.
Phys Med Biol ; 62(2): 652-668, 2017 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-28033121

RESUMO

A major source of error in quantitative PET/CT scans of lung cancer tumors is respiratory motion. Regarding the variability of PET texture features (TF), the impact of respiratory motion has not been properly studied with experimental phantoms. The primary aim of this work was to evaluate the current use of PET texture analysis for heterogeneity characterization in lesions affected by respiratory motion. Twenty-eight heterogeneous lesions were simulated by a mixture of alginate and 18 F-fluoro-2-deoxy-D-glucose (FDG). Sixteen respiratory patterns were applied. Firstly, the TF response for different heterogeneous phantoms and its robustness with respect to the segmentation method were calculated. Secondly, the variability for TF derived from PET image with (gated, G-) and without (ungated, U-) motion compensation was analyzed. Finally, TF complementarity was assessed. In the comparison of TF derived from the ideal contour with respect to TF derived from 40%-threshold and adaptive-threshold PET contours, 7/8 TF showed strong linear correlation (LC) (p < 0.001, r > 0.75), despite a significant volume underestimation. Independence of lesion movement (LC in 100% of the combined pairs of movements, p < 0.05) was obtained for 1/8 TF with U-image (width of the volume-activity histogram, WH) and 4/8 TF with G-image (WH and energy (ENG), local-homogeneity (LH) and entropy (ENT), derived from the co-ocurrence matrix). Their variability in terms of the coefficient of variance ([Formula: see text]) resulted in [Formula: see text](WH) = 0.18 on the U-image and [Formula: see text](WH) = 0.24, [Formula: see text](ENG) = 0.15, [Formula: see text](LH) = 0.07 and [Formula: see text](ENT) = 0.06 on the G-image. Apart from WH (r > 0.9, p < 0.001), not one of these TF has shown LC with C max. Complementarity was observed for the TF pairs: ENG-LH, CONT (contrast)-ENT and LH-ENT. In conclusion, the effect of respiratory motion should be taken into account when the heterogeneity of lung cancer is quantified on PET/CT images. Despite inaccurate volume delineation, TF derived from 40% and COA contours could be reliable for their prognostic use. The TF that exhibited simultaneous added value and independence of lesion movement were ENG and ENT computed from the G-image. Their use is therefore recommended for heterogeneity quantification of lesions affected by respiratory motion.


Assuntos
Fluordesoxiglucose F18/metabolismo , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Movimento , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos , Humanos , Neoplasias Pulmonares/metabolismo , Respiração
13.
Neurología (Barc., Ed. impr.) ; 29(2): 68-75, mar. 2014. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-119448

RESUMO

Objetivos: El objetivo de este estudio es valorar si la RM en contraste de fase es una herramienta útil en el diagnóstico de la hidrocefalia a presión normal (HPN), así como su diferenciación con otras afecciones neurológicas muy similares clínicamente. Métodos: Se incluyó a un total de 108 sujetos, de los cuales 61 eran sujetos sanos control, y 47 pacientes; 19 de ellos fueron clasificados en el grupo de pacientes con enfermedad cerebrovascular isquémica (ECI) y 28 pacientes dentro del grupo de HPN. A todos los pacientes se les realizó una RM en contraste de fase con cuantificación de parámetros de flujo y velocidad de LCR en el acueducto de Silvio. Se evaluó la capacidad de clasificación de los parámetros individualmente y combinándolos mediante análisis discriminantes. Resultados: Los parámetros de velocidad máxima diastólica, flujo promedio y volumen por ciclo mostraron diferencias estadísticamente significativas para separar a los pacientes con HPN y con ECI (p < 0,001). El volumen por ciclo y el flujo promedio no presentaron falsos positivos, con tasas de acierto del 86% y 79%, respectivamente. El resto de parámetros y la combinación de todos ellos no mejoraron los resultados. Conclusiones: La RM en contraste de fase es una herramienta muy útil para el diagnóstico precoz de los pacientes con HPN. La cuantificación de parámetros de flujo de LCR junto con la valoración del estudio morfológico de la RM convencional permite diferenciar a los pacientes con HPN de los pacientes con ECI


Objectives: The aim of this study is to evaluate the use of phase-contrast MR imaging to diagnose normal pressure hydrocephalus (NPH) and differentiate it from other neurological disorders with similar clinical symptoms. Methods: The study included 108 subjects, of whom 61 were healthy controls and 47, patients; in the patient group, 19 had cerebrovascular disease (CVD) and 28 had NPH. All patients underwent a phase-contrast MRI study and several CSF flow and velocity parameters were measured at the aqueduct of Sylvius. Discriminant analyses were performed to evaluate the classification capacity of both individual parameters and the combination of different parameters. Results: Maximum diastolic velocity, mean flow, and stroke volume showed statistically significant differences that could be used to distinguish between NPH and CVD patients (P<.001). Stroke volume and mean flow showed no false positive results and successful classification rates of 86% and 79%, respectively. No other parameters or combination produced better results. Conclusions: Phase-contrast MR imaging is a useful tool for the early diagnosis of patients with NPH. CSF flow quantitative parameters, along with morphological features in a conventional MR study, enable us to differentiate between NPH and CVD patients


Assuntos
Humanos , Líquido Cefalorraquidiano , Hidrocefalia de Pressão Normal/diagnóstico , Aqueduto do Mesencéfalo/fisiopatologia , Pressão do Líquido Cefalorraquidiano , Espectroscopia de Ressonância Magnética , Derivações do Líquido Cefalorraquidiano
14.
Radiología (Madr., Ed. impr.) ; 56(1): 27-34, ene.-feb. 2014. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-118517

RESUMO

Objetivo. En este trabajo se analizan en un modelo animal la reproducibilidad y la exactitud de ciertos biomarcadores de imagen de calidad ósea utilizando como patrón de referencia la microtomografía computarizada (mTC). Material y métodos. Se estudiaron con RM y mTC 5 metáfisis tibiales de oveja. Las imágenes de RM (3 Tesla) se adquirieron con una secuencia eco de gradiente potenciada en T1 y una resolución espacial isotrópica de 180 mm. Las imágenes de mTC se adquirieron en un escáner con una resolución espacial de 7,5 mm en vóxeles isotrópicos. En la preparación de las imágenes se aplicaron algoritmos de ecualización, interpolación y umbralización. En el análisis cuantitativo se calculó el porcentaje de volumen de hueso (BV/TV), el grosor trabecular (Tb.Th), la separación trabecular (Tb.Sp), el índice trabecular (Tb.N), la dimensión fractal en 2 D (D2D) y 3 D (D3D) y el módulo elástico en las 3 direcciones del espacio (Ex, Ey y Ez). Resultados. La cuantificación morfométrica y mecánica del hueso esponjoso con la RM fue muy reproducible, con porcentajes de variación por debajo del 9% para todos los parámetros. Su exactitud con respecto a la mTC fue alta, con errores inferiores al 15% para BV/TV, D2D, D3D y Eappx, Eappy y Eappz. Conclusiones. Los resultados experimentales en animales confirman que los parámetros de BV/TV, D2D, D3D y Eappx, Eappy y Eappz obtenidos a partir de RM tienen una excelente reproducibilidad y precisión, y pueden emplearse como biomarcadores de imagen de la calidad del hueso trabecular (AU)


Objective: We used an animal model to analyze the reproducibility and accuracy of certain biomarkers of bone image quality in comparison to a gold standard of computed microtomography (mCT). Material and methods: We used magnetic resonance (MR) imaging and mCT to study the metaphyses of 5 sheep tibiae. The MR images (3 Teslas) were acquired with a T1-weighted gradient echo sequence and an isotropic spatial resolution of 180 mm. The mCT images were acquired using a scanner with a spatial resolution of 7.5 mm isotropic voxels. In the preparation of the images, we applied equalization, interpolation, and thresholding algorithms. In the quantitative analysis, we calculated the percentage of bone volume (BV/TV), the trabecular thickness (Tb.Th), the trabecular separation (Tb.Sp), the trabecular index (Tb.N), the 2 D fractal dimension (D2D), the 3 D fractal dimension (D3D), and the elastic module in the three spatial directions (Ex, Ey and Ez). Results: The morphometric and mechanical quantification of trabecular bone by MR was very reproducible, with percentages of variation below 9% for all the parameters. Its accuracy compared to the gold standard (mCT) was high, with errors less than 15% for BV/TV, D2D, D3D, and Eappx, Eappy and Eappz. Conclusions: Our experimental results in animals confirm that the parameters of BV/TV, D2D, D3D, and Eappx, Eappy and Eappz obtained by MR have excellent reproducibility and accuracy and can be used as imaging biomarkers for the quality of trabecular bone (AU)


Assuntos
Animais , Masculino , Feminino , Malha Trabecular/fisiopatologia , Malha Trabecular , Biomarcadores/análise , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Osteoporose , Reprodutibilidade dos Testes , Tíbia , Ovinos
15.
Neurologia ; 29(2): 68-75, 2014 Mar.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-23643684

RESUMO

OBJECTIVES: The aim of this study is to evaluate the use of phase-contrast MR imaging to diagnose normal pressure hydrocephalus (NPH) and differentiate it from other neurological disorders with similar clinical symptoms. METHODS: The study included 108 subjects, of whom 61 were healthy controls and 47, patients; in the patient group, 19 had cerebrovascular disease (CVD) and 28 had NPH. All patients underwent a phase-contrast MRI study and several CSF flow and velocity parameters were measured at the aqueduct of Sylvius. Discriminant analyses were performed to evaluate the classification capacity of both individual parameters and the combination of different parameters. RESULTS: Maximum diastolic velocity, mean flow, and stroke volume showed statistically significant differences that could be used to distinguish between NPH and CVD patients (P<.001). Stroke volume and mean flow showed no false positive results and successful classification rates of 86% and 79%, respectively. No other parameters or combination produced better results. CONCLUSIONS: Phase-contrast MR imaging is a useful tool for the early diagnosis of patients with NPH. CSF flow quantitative parameters, along with morphological features in a conventional MR study, enable us to differentiate between NPH and CVD patients.


Assuntos
Líquido Cefalorraquidiano , Hidrocefalia de Pressão Normal/líquido cefalorraquidiano , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Hidrocefalia de Pressão Normal/fisiopatologia , Masculino , Pessoa de Meia-Idade , Adulto Jovem
16.
Radiologia ; 56(1): 27-34, 2014.
Artigo em Espanhol | MEDLINE | ID: mdl-24094441

RESUMO

OBJECTIVE: We used an animal model to analyze the reproducibility and accuracy of certain biomarkers of bone image quality in comparison to a gold standard of computed microtomography (µCT). MATERIAL AND METHODS: We used magnetic resonance (MR) imaging and µCT to study the metaphyses of 5 sheep tibiae. The MR images (3 Teslas) were acquired with a T1-weighted gradient echo sequence and an isotropic spatial resolution of 180µm. The µCT images were acquired using a scanner with a spatial resolution of 7.5µm isotropic voxels. In the preparation of the images, we applied equalization, interpolation, and thresholding algorithms. In the quantitative analysis, we calculated the percentage of bone volume (BV/TV), the trabecular thickness (Tb.Th), the trabecular separation (Tb.Sp), the trabecular index (Tb.N), the 2D fractal dimension (D(2D)), the 3D fractal dimension (D(3D)), and the elastic module in the three spatial directions (Ex, Ey and Ez). RESULTS: The morphometric and mechanical quantification of trabecular bone by MR was very reproducible, with percentages of variation below 9% for all the parameters. Its accuracy compared to the gold standard (µCT) was high, with errors less than 15% for BV/TV, D(2D), D(3D), and E(app)x, E(app)y and E(app)z. CONCLUSIONS: Our experimental results in animals confirm that the parameters of BV/TV, D(2D), D(3D), and E(app)x, E(app)y and E(app)z obtained by MR have excellent reproducibility and accuracy and can be used as imaging biomarkers for the quality of trabecular bone.


Assuntos
Osso e Ossos/anatomia & histologia , Imageamento por Ressonância Magnética , Animais , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Ovinos
17.
Radiología (Madr., Ed. impr.) ; 55(3): 188-194, mayo-jun. 2013.
Artigo em Espanhol | IBECS | ID: ibc-112243

RESUMO

Los biomarcadores de imagen describen características objetivas que están relacionadas con procesos biológicos normales, enfermedades, o la respuesta al tratamiento. Permiten a los radiólogos incorporar datos de estructura, función y componentes tisulares a sus informes. Con el fin de aprovechar al máximo las ventajas de la cuantificación de imagen médica se plantea un procedimiento para integrar los biomarcadores de imagen, acercando el nuevo paradigma de medicina personalizada al flujo de trabajo radiológico. Así, los resultados de cuantificación pueden complementar el diagnóstico radiológico tradicional, mejorando su precisión y la evaluación de la eficacia de los tratamientos. Un informe radiológico más personalizado, estandarizado y estructurado debe implementar los análisis cuantitativos como una buena alternativa complementaria al informe radiológico cualitativo convencional en casos previamente seleccionados (AU)


Imaging biomarkers describe objective characteristics that are related to normal biological processes, diseases, or the response to treatment. They enable radiologists to incorporate into their reports data about structure, function, and tissue components. With the aim of taking maximum advantage of the quantification of medical images, we present a procedure to integrate imaging biomarkers into radiological reports, bringing the new paradigm of personal medicine closer to radiological workflow. In this manner, the results of quantification can complement traditional radiological diagnosis, improving accuracy and the evaluation of the efficacy of treatments. A more personalized, standardized, structured radiological report should include quantitative analyses to complement conventional qualitative reporting in selected cases (AU)


Assuntos
Humanos , Masculino , Feminino , Biomarcadores/análise , Adenoma , Relatório de Pesquisa/legislação & jurisprudência , Relatório de Pesquisa/normas , Relatório de Pesquisa/tendências , 25783/métodos , Punho , Radiologia/educação , Radiologia/estatística & dados numéricos
18.
Radiología (Madr., Ed. impr.) ; 55(2): 99-106, mar.-abr. 2013.
Artigo em Espanhol | IBECS | ID: ibc-110290

RESUMO

La RM es una potente herramienta de diagnóstico por imagen cuyo uso ha aumentado significativamente en los hospitales de todo el mundo. Debido a sus particularidades técnicas, para poder utilizarla sin peligro es necesario que todo el personal relacionado con ella conozca adecuadamente su funcionamiento y los aspectos relacionados con la seguridad. La Directiva de Agentes Físicos (EMF) 2004/40/CE supone una amenaza para el desarrollo clínico y la labor asistencial de la RM. El esfuerzo de la Alliance for MRI supuso una ampliación en el plazo de decisión del Parlamento Europeo hasta abril de 2012, que se extendió finalmente a octubre de 2013. El propósito de este trabajo es definir y proponer un conjunto de reglas prácticas para garantizar la protección de los trabajadores involucrados con la RM. Pretende también servir de posicionamiento frente a los planteamientos de la Directiva de la UE (2004/40/CE) (AU)


MRI is a powerful diagnostic imaging tool and its use has increased significantly in hospitals all over the world. Due to the technical particularities of MRI, all staff members dealing with the scanner need to have adequate knowledge of how it works and of aspects related to safety. The European parliament and council's directive on minimum health and safety requirements for workers dealing with electromagnetic fields (EMF) 2004/40/CE represents a threat to the clinical development and healthcare use of MRI. The efforts of the Alliance for MRI led to a postponement of the European parliament's decision, first until April 2012 and finally until October 2013. The purpose of this article is to define and propose a set of practical rules to ensure the protection of workers involved with MRI scanners. It also aims to define our position with respect to UE directive (2004/40/CE) (AU)


Assuntos
Humanos , Masculino , Feminino , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética/métodos , Medidas de Segurança/normas , Medidas de Segurança , Radiação Eletromagnética , Medidas de Segurança/organização & administração , Medidas de Segurança/tendências , Diagnóstico por Imagem/métodos , Diagnóstico por Imagem , Radiologia/legislação & jurisprudência , Radiologia
19.
Radiologia ; 55(3): 188-94, 2013.
Artigo em Espanhol | MEDLINE | ID: mdl-23352320

RESUMO

Imaging biomarkers describe objective characteristics that are related to normal biological processes, diseases, or the response to treatment. They enable radiologists to incorporate into their reports data about structure, function, and tissue components. With the aim of taking maximum advantage of the quantification of medical images, we present a procedure to integrate imaging biomarkers into radiological reports, bringing the new paradigm of personal medicine closer to radiological workflow. In this manner, the results of quantification can complement traditional radiological diagnosis, improving accuracy and the evaluation of the efficacy of treatments. A more personalized, standardized, structured radiological report should include quantitative analyses to complement conventional qualitative reporting in selected cases.


Assuntos
Biomarcadores , Prontuários Médicos , Radiografia , Humanos
20.
Radiologia ; 55(2): 99-106, 2013.
Artigo em Espanhol | MEDLINE | ID: mdl-23332580

RESUMO

MRI is a powerful diagnostic imaging tool and its use has increased significantly in hospitals all over the world. Due to the technical particularities of MRI, all staff members dealing with the scanner need to have adequate knowledge of how it works and of aspects related to safety. The European parliament and council's directive on minimum health and safety requirements for workers dealing with electromagnetic fields (EMF) 2004/40/CE represents a threat to the clinical development and healthcare use of MRI. The efforts of the Alliance for MRI led to a postponement of the European parliament's decision, first until April 2012 and finally until October 2013. The purpose of this article is to define and propose a set of practical rules to ensure the protection of workers involved with MRI scanners. It also aims to define our position with respect to UE directive (2004/40/CE).


Assuntos
Imageamento por Ressonância Magnética/normas , Segurança do Paciente , Pessoal de Saúde , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...