Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 24(9 Pt 1): 1369-76, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11584459

RESUMO

The QRS widening by ventricular conventional pacing impairs the systolic and diastolic functions and increases mitral regurgitation. The aim of this study was to compare conventional pacing to an alternative stimulation mode with a narrower QRS using two leads in the RV. Thirty-nine (25 men, 14 women; mean age 60.1 +/- 15.1 years) dilated cardiomyopathy patients (Chagas' disease [n = 17], coronariopathy [n = 9], AV ablation for tachycardiomyopathy [n = 3], and other [n = 10]) with cardiac failure (NYHA 3.1 +/- 0.8), pacemaker indication, and chronic AV block (22 AF) had endocardial pacemaker implantations (27 Biotronik, 12 Guidant). Two RV leads (one septal, one conventional [RV apex] were connected, respectively, to the atrial and ventricular pacemaker plugs. After clinical stabilization they were studied under three stimulation modes in the same session: AAI (septal), VVI (conventional), and ventricular endocardial right bifocal stimulation (VERBS) (DDT/DVI/DDD = AV interval = 15/10 ms). In comparison to conventional pacing, VERBS increased ejection fraction (0.124), cardiac output (19.5%), and peak filling rate (31.0%), and decreased QRS duration (24.7%), left atrium area (11.9%), mitral regurgitation area (32.3%), the diastolic transmitral flow (E/A relation) (19.3%), and the propagation flow time (18.0%) from the mitral valve to the left ventricular apex (tE_col), (P < 0.05). The quality-of-life showed an impressive score reduction of 50.4%. The septal stimulation alone showed a less expressive benefit. In severe dilated cardiomyopathy with classic pacemaker indication, VERBS showed significantly better performance than the septal or the conventional stimulation alone. There was a good systolic and a remarkable diastolic improvement causing an important reduction in the quality-of-life score.


Assuntos
Cardiomiopatia Dilatada/terapia , Eletrodos Implantados , Endocárdio/fisiopatologia , Insuficiência Cardíaca/terapia , Marca-Passo Artificial , Adulto , Idoso , Idoso de 80 Anos ou mais , Cardiomiopatia Dilatada/fisiopatologia , Ecocardiografia , Feminino , Seguimentos , Átrios do Coração/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/terapia , Qualidade de Vida , Volume Sistólico/fisiologia
2.
Arq Bras Cardiol ; 73(6): 485-98, 1999 Dec.
Artigo em Inglês, Português | MEDLINE | ID: mdl-10904269

RESUMO

OBJECTIVE: To describe a new more efficient method of endocardial cardiac stimulation, which produces a narrower QRS without using the coronary sinus or cardiac veins. METHODS: We studied 5 patients with severe dilated cardiomyopathy, chronic atrial fibrillation and AV block, who underwent definitive endocardial pacemaker implantation, with 2 leads, in the RV, one in the apex and the other in the interventricular septum (sub pulmonary), connected, respectively, to ventricular and atrial bicameral pacemaker outputs. Using Doppler echocardiography, we compared, in the same patient, conventional (VVI), high septal ("AAI") and bifocal ("DDT" with AV interval approximately 0) stimulation. RESULTS: The RV bifocal stimulation had the best results with an increase in ejection fraction and cardiac output and reduction in QRS duration, mitral regurgitation and in the left atrium area (p

Assuntos
Estimulação Cardíaca Artificial/métodos , Cardiomiopatia Dilatada/terapia , Adulto , Idoso , Fibrilação Atrial/terapia , Cardiomiopatia Dilatada/diagnóstico por imagem , Doença Crônica , Eletrodos Implantados , Feminino , Bloqueio Cardíaco/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/terapia , Marca-Passo Artificial , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA