Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Graefes Arch Clin Exp Ophthalmol ; 259(1): 181-189, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32845373

RESUMO

PURPOSE: Evaluate short-term intraoperator reproducibility of ultrasonographic measurements of choroidal nevi using 10- and 20-MHz probes, and the efficacy of the high-frequency probes for the diagnosis of choroidal nevi. METHODS: Diameters and thicknesses of choroidal nevi were measured using a 10-MHz probe and a high-frequency long focal length 20-MHz probe (Quantel Medical™). The first part of the study evaluated intraoperator reproducibility of measurements of choroidal nevi with 10- and 20-MHz probes and the second part of the study allowed the comparisons of the measurements of largest tumor diameter (LDT) of choroidal nevi of 40 patients between the 10- and 20-MHz probes. The two-way random average agreement intraclass correlation coefficients (ICC), Bland-Altman plot, and a paired t test were used. RESULTS: The intraoperator reproducibility of choroidal nevi measurements with 10- and 20-MHz probes was excellent (ICC > 0.9, n = 20). Four flat nevi, not detectable at 10 MHz, could be located with the high-frequency probe (p = 0.12). There was no significant difference in thickness or LTD measurements between the 10- and 20-MHz probes (n = 31). Both techniques showed an excellent agreement (ICC > 0.8) for thickness and LTD measurements. All the choroidal nevi that were not measurable with the 10-MHz probe (n = 7) were measured with the 20-MHz probe. CONCLUSION: The high-frequency 20-MHz probe allows additional detection and measurements of flat choroidal nevi. When detectable, the ultrasonographic measurements of thickness and diameter of choroidal nevi are similar with both the 10- and the 20-MHz probes.


Assuntos
Neoplasias da Coroide , Nevo , Neoplasias Cutâneas , Neoplasias da Coroide/diagnóstico por imagem , Humanos , Nevo/diagnóstico por imagem , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica , Ultrassonografia
2.
Retina ; 33(10): 2039-48, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23492949

RESUMO

PURPOSE: To compare the anatomical and functional results of primary rhegmatogenous retinal detachment in highly myopic phakic or pseudophakic eyes. METHODS: This prospective 2-center study included 191 consecutive eyes (151 phakic and 40 pseudophakic eyes) from a prospective cohort of 835 patients (IRB #5891, between 2004 and 2008). Baseline and follow-up data were systematically recorded at presentation, 1 month, and 6 months or more after surgery. On final examination, two groups were considered based on the need for one or more surgeries to achieve retinal reapplication. End points were primary reattachment rate at the 6-month visit, final anatomical success rate, postoperative visual acuity, and intraoperative and postoperative complications. RESULTS: Pseudophakic eyes differed from phakic eyes in age (60.8 ± 10.4 vs. 49.9 ± 12.3, P < 0.001), smaller pupil dilation (8.0 ± 1.5 vs. 8.5 ± 1.2 mm, P = 0.02), fewer retinal tears seen preoperatively (1.5 ± 1.6 vs. 2.2 ± 2.2, P = 0.06), more frequent use of pars plana vitrectomy (80% vs. 28.5%, P < 0.001), and higher single reattachment rate (92.5% vs. 80.7%). Visual acuity was greater than or equal to 20/40 in 54% of cases with single retinal detachment surgery and 44% of cases with multiple surgeries. Multiple logistic regression analysis showed that only 3 independent variables were significantly predictive of good final visual acuity (20/40): initial visual acuity (<20/400, odds ratio = 0.19; 95% confidence interval, 0.07-0.51; P = 0.002), axial length (odds ratio = 0.57; 95% confidence interval, 0.44-0.75, P < 0.001), and pars plana vitrectomy (odds ratio = 0.33; 95% confidence interval, 0.15-0.71, P = 0.004). CONCLUSION: This prospective study showed similar baseline retinal detachment characteristics of high myopic phakic or pseudophakic eyes, suggesting that high myopia was the main pathogenic factor in both groups. Although high myopic eye presents anatomical characteristics that could favor surgical morbidity, these recent prospective data show that high myopic eyes exhibit functional and anatomical prognosis close to that described in emmetropic eyes.


Assuntos
Cristalino/fisiologia , Miopia Degenerativa/complicações , Pseudofacia/complicações , Descolamento Retiniano/etiologia , Vitrectomia , Crioterapia , Feminino , Humanos , Complicações Intraoperatórias , Fotocoagulação a Laser , Masculino , Pessoa de Meia-Idade , Miopia Degenerativa/fisiopatologia , Complicações Pós-Operatórias , Estudos Prospectivos , Pseudofacia/fisiopatologia , Descolamento Retiniano/fisiopatologia , Descolamento Retiniano/cirurgia , Recurvamento da Esclera , Acuidade Visual/fisiologia
3.
Graefes Arch Clin Exp Ophthalmol ; 249(10): 1459-68, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21499771

RESUMO

PURPOSE: To compare the safety and efficacy of 20- and 23-gauge pars plana vitrectomy (PPV) for the management of primary rhegmatogenous retinal detachment (RD) with proliferative vitreoretinopathy (PVR) grade B or less. METHODS: This comparative nested case-control study included 35 consecutive 23-gauge transconjunctival PPV cases matched (1:1) with 35 cases of 20-gauge PPV (from a prospective cohort of 1,150 patients) for the baseline visual acuity (VA), axial length, lens and macular status, the location and number of breaks, and PVR grade. All patients had complete PPV, cryotherapy, fluid-gas exchange, and a minimum follow-up of 6 months. The exclusion criteria were eyes with previous vitreoretinal surgery, combined vitrectomy and cataract surgery, RD secondary to trauma or macular hole, diabetic retinopathy, aphakic eyes, giant tears, or posteriorly located breaks precluding treatment using transconjunctival cryotherapy. RESULTS: Baseline examination disclosed pseudophakia in 77.1%, high myopia in 11.4%, 2.7 ± 2.2 retinal breaks/eye, attached macula in 37.1%, and PVR grade B in 24.3% of the cases. The mean operative time and intraoperative complication rate (11.4%) were similar in both groups. In the 23-G group, we noted three cases of iatrogenic retinal tears and one case of choroidal detachment secondary to a dislodgment of the infusion line. Suturing the sclerotomy sites or the conjunctiva was required in 5.7 and 51% of the eyes, respectively. The single reattachment rate was similar in both groups, 74.3% in the 20-G group, and 80% in the 23-G group. The final anatomical success rate was 97% in the two groups. Mean preoperative VA of 1.2 ± 0.9 logMAR improved similarly in both groups to 0.4 ± 0.4 at the 6-month visit. A final vision of 20/40 or better was achieved similarly in 62.9% of the eyes in the 20-G group and 60% in the 23-G group. CONCLUSIONS: Twenty-three-gauge PPV provides anatomical and visual results similar to the 20-G technique for the management of uncomplicated rhegmatogenous RD.


Assuntos
Agulhas , Descolamento Retiniano/cirurgia , Vitrectomia/instrumentação , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Descolamento Retiniano/complicações , Descolamento Retiniano/fisiopatologia , Estudos Retrospectivos , Técnicas de Sutura , Fatores de Tempo , Resultado do Tratamento , Acuidade Visual , Vitreorretinopatia Proliferativa/complicações , Vitreorretinopatia Proliferativa/fisiopatologia , Vitreorretinopatia Proliferativa/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...