Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Australas Emerg Care ; 25(4): 273-282, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35123929

RESUMO

OBJECTIVE: To identify barriers to, describe the development of and evaluate the implementation of a behavioural theory informed strategy to improve staff personal protective equipment (PPE) compliance during COVID-19 in a regional Australian Emergency Department. METHODS: Barriers to PPE use were identified through staff consultation then categorised using the Theoretical Domains Framework. The Behaviour Change Wheel was used to develop a strategy to address the barriers to PPE compliance. The strategy was refined and endorsed by the site COVID taskforce. Data were collected through direct observation. Descriptive statistics were used to summarise PPE compliance and inductive content analysis for free text data of staff behaviours. RESULTS: 73 barriers were identified, mapped to 9 intervention functions and 42 behaviour change techniques. The predominant mechanisms were: (1) Executive communication reinforcing policy and consequences; (2) implementation of a PPE Marshal; (3) face to face reinforcement / modeling; (4) environmental restructuring including electronic medical record modifications. The PPE Marshal observed 281 PPE activities. PPE compliance varied between 47.9% (Buddy check) and 91.8% (Bare below elbow). The PPE Marshal intervened on 121 occasions, predominantly through buddying, explaining and demonstrating correct PPE use, most frequently with medical staff (72%). CONCLUSION: We describe an evidence-based process to overcome barriers to PPE compliance that maximize safe work practice in a time critical situation. Staff require enabling, access to equipment and reinforcement to use PPE correctly.


Assuntos
COVID-19 , Equipamento de Proteção Individual , Austrália , COVID-19/prevenção & controle , Serviço Hospitalar de Emergência , Humanos , Encaminhamento e Consulta
2.
Biosensors (Basel) ; 10(11)2020 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-33114106

RESUMO

Antibiotic resistance has been cited by the World Health Organisation (WHO) as one of the greatest threats to public health. Mitigating the spread of antibiotic resistance requires a multipronged approach with possible interventions including faster diagnostic testing and enhanced antibiotic stewardship. This study employs a low-cost diagnostic sensor test to rapidly pinpoint the correct antibiotic for treatment of infection. The sensor comprises a screen-printed gold electrode, modified with an antibiotic-seeded hydrogel to monitor bacterial growth. Electrochemical growth profiles of the common microorganism, Escherichia coli (E. coli) (ATCC 25922) were measured in the presence and absence of the antibiotic streptomycin. Results show a clear distinction between the E. coli growth profiles depending on whether streptomycin is present, in a timeframe of ≈2.5 h (p < 0.05), significantly quicker than the current gold standard of culture-based antimicrobial susceptibility testing. These results demonstrate a clear pathway to a low cost, phenotypic and reproducible antibiotic susceptibility testing technology for the rapid detection of E. coli within clinically relevant concentration ranges for conditions such as urinary tract infections.


Assuntos
Técnicas Biossensoriais , Eletrodos , Escherichia coli , Testes de Sensibilidade Microbiana/métodos , Antibacterianos , Resistência Microbiana a Medicamentos , Infecções por Escherichia coli , Humanos
3.
Biosens Bioelectron ; 145: 111696, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31542679

RESUMO

Antimicrobial resistance (AMR) is an issue of upmost global importance, with an annually increasing mortality rate and growing economic burden. Poor antimicrobial stewardship has resulted in an abundance and diverse range of antimicrobial resistance mechanisms. To tackle AMR effectively, better diagnostic tests must be developed in order to improve antibiotic stewardship and reduce the emergence of antibiotic resistant organisms. This study employs a low-cost, commercially available screen printed electrode modified with an agarose-based hydrogel deposit to monitor bacterial growth using the techniques of electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV) giving rise to a new approach to measuring susceptibility. Susceptible and drug resistant Staphylococcus aureus strains were deposited onto agarose gel modified electrodes which contained clinically important antibiotics to establish growth profiles for each bacterial strain and monitor the influence of the antibiotic on bacterial growth. The results show that S. aureus is able to grow on electrodes modified with gel containing no antibiotic, but is inhibited when the gel modified electrode is seeded with antibiotic. Conversely, methicillin-resistant S. aureus (MRSA; the drug resistant strain) is able to grow on gel modified electrodes containing clinically relevant concentrations of antibiotic. Results show rapid growth profiles, with possible time to results for antibiotic susceptibility <45 min, a significant improvement on the current gold standards of at least 1-2 days.


Assuntos
Técnicas Biossensoriais , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Infecções Estafilocócicas/diagnóstico , Antibacterianos/uso terapêutico , Eletrodos , Humanos , Testes de Sensibilidade Microbiana , Infecções Estafilocócicas/tratamento farmacológico , Infecções Estafilocócicas/microbiologia
4.
Biosens Bioelectron ; 126: 806-814, 2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30602262

RESUMO

This paper outlines a simple label-free sensor system for the sensitive, real time measurement of an important protein biomarker of sepsis, using a novel microelectrode integrated onto a needle shaped substrate. Sepsis is a life threatening condition with a high mortality rate, which is characterised by dysregulation of the immune response following infection, leading to organ failure and cardiovascular collapse if untreated. Currently, sepsis testing is typically carried out by taking blood samples which are sent to a central laboratory for processing. Analysis times can be between 12 and 72 h making it notoriously difficult to diagnose and treat patients in a timely manner. The pathobiology of sepsis is becoming increasingly well understood and clinically relevant biomarkers are emerging, which could be used in conjunction with a biosensor to support real time diagnosis of sepsis. In this context, microelectrodes have the analytical advantages of reduced iR drop, enhanced signal to noise ratio, simplified quantification and the ability to measure in hydrodynamic situations, such as the bloodstream. In this study, arrays of eight (r = 25 µm) microelectrodes were fabricated onto needle shaped silicon substrates and electrochemically characterised in order to confirm successful sensor production and to verify whether the observed behaviour agreed with established theory. After this, the electrodes were functionalised with an antibody for interleukin-6 (IL-6) which is a protein involved in the immune response to infection and whose levels in the blood increase during progression of sepsis. The results show that IL-6 is detectable at physiologically relevant levels (pg/mL) with incubation times as short as 2.5 min. Electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV) measurements were taken and DPV was concluded to be the more suitable form of measurement. In contrast to the accepted view for macro electrodes that the impedance increases upon antigen bind, we report herein a decrease in the micro electrode impedance upon binding. The small size of the fabricated devices and their needle shape make them ideal for either point of care testing or insertion into blood vessels for continuous sepsis monitoring.


Assuntos
Técnicas Eletroquímicas/instrumentação , Interleucina-6/análise , Sepse/diagnóstico , Biomarcadores/análise , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Espectroscopia Dielétrica , Técnicas Eletroquímicas/métodos , Ouro/química , Humanos , Microeletrodos , Silício/química
5.
Crit Care ; 15(6): R296, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22177541

RESUMO

INTRODUCTION: Fluid strategies may impact on patient outcomes in major elective surgery. We aimed to study the effectiveness and cost-effectiveness of pre-operative fluid loading in high-risk surgical patients undergoing major elective surgery. METHODS: This was a pragmatic, non-blinded, multi-centre, randomised, controlled trial. We sought to recruit 128 consecutive high-risk surgical patients undergoing major abdominal surgery. The patients underwent pre-operative fluid loading with 25 ml/kg of Ringer's solution in the six hours before surgery. The control group had no pre-operative fluid loading. The primary outcome was the number of hospital days after surgery with cost-effectiveness as a secondary outcome. RESULTS: A total of 111 patients were recruited within the study time frame in agreement with the funder. The median pre-operative fluid loading volume was 1,875 ml (IQR 1,375 to 2,025) in the fluid group compared to 0 (IQR 0 to 0) in controls with days in hospital after surgery 12.2 (SD 11.5) days compared to 17.4 (SD 20.0) and an adjusted mean difference of 5.5 days (median 2.2 days; 95% CI -0.44 to 11.44; P = 0.07). There was a reduction in adverse events in the fluid intervention group (P = 0.048) and no increase in fluid based complications. The intervention was less costly and more effective (adjusted average cost saving: £2,047; adjusted average gain in benefit: 0.0431 quality adjusted life year (QALY)) and has a high probability of being cost-effective. CONCLUSIONS: Pre-operative intravenous fluid loading leads to a non-significant reduction in hospital length of stay after high-risk major surgery and is likely to be cost-effective. Confirmatory work is required to determine whether these effects are reproducible, and to confirm whether this simple intervention could allow more cost-effective delivery of care. TRIAL REGISTRATION: Prospective Clinical Trials, ISRCTN32188676.


Assuntos
Procedimentos Cirúrgicos Eletivos/métodos , Hidratação/métodos , Cuidados Pré-Operatórios/métodos , Idoso , Idoso de 80 Anos ou mais , Análise Custo-Benefício , Procedimentos Cirúrgicos Eletivos/economia , Feminino , Hidratação/economia , Humanos , Soluções Isotônicas/economia , Soluções Isotônicas/uso terapêutico , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios/economia , Solução de Ringer , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA