1.
Crit Rev Clin Lab Sci ; : 1-23, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38361287

RESUMO

Extracellular vesicles (EVs) are nano-sized particles secreted by most cells. They transport different types of biomolecules (nucleic acids, proteins, and lipids) characteristic of their tissue or cellular origin that can mediate long-distance intercellular communication. In the case of cancer, EVs participate in tumor progression by modifying the tumor microenvironment, favoring immune tolerance and metastasis development. Consequently, EVs have great potential in liquid biopsy for cancer diagnosis, prognosis and follow-up. In addition, EVs could have a role in cancer treatment as a targeted drug delivery system. The intense research in the EV field has resulted in hundreds of patents and the creation of biomedical companies. However, methodological issues and heterogeneity in EV composition have hampered the advancement of EV validation trials and the development of EV-based diagnostic and therapeutic products. Consequently, only a few EV biomarkers have moved from research to clinical laboratories, such as the ExoDx Prostate IntelliScore (EPI) test, a CLIA/FDA-approved EV prostate cancer diagnostic test. In addition, the number of large-scale multicenter studies that would clearly define biomarker performance is limited. In this review, we will critically describe the different types of EVs, the methods for their enrichment and characterization, and their biological role in cancer. Then, we will specially focus on the parameters to be considered for the translation of EV biology to the clinic laboratory, the advances already made in the field of EVs related to cancer diagnosis and treatment, and the issues still pending to be solved before EVs could be used as a routine tool in oncology.

2.
Clin Chim Acta ; 548: 117502, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37516333

RESUMO

BACKGROUND AND AIMS: Patients' response to treatment in differentiated thyroid cancer (DTC) is classified according to serum thyroglobulin concentrations (Tg), usually using the American Thyroid Association guidelines and considering potential interfering anti-thyroglobulin antibodies (Ab-Tg). We aim to evaluate the clinical implications of changing Tg and Ab-Tg quantification method. MATERIAL AND METHODS: Tg and Ab-Tg were quantified in 82 serum samples (60 from DTC patients) by Elecsys and Access immunoassays. RESULTS: Elecsys immunoassay rendered higher values of Tg than Access: mean bias 5.03 ng/mL (95%CI:-14.14-24.21). In DTC patients, there was an almost perfect agreement for response classification (kappa index = 0.833). Discrepancies appeared in patients with undetermined response, with a more tendency to subclassification with Access. Ab-Tg showed a poor correlation (r = 0.5394). When Elecsys cut-off was reduced to 43 IU/mL, agreement for positive/negative classification improved from a kappa index of 0.607 to 0.650. Prospective study with personalized follow-up showed that only 6.3% of Tg results required an analytical confirmation, being confirmed 93% of them. CONCLUSIONS: Despite the biases observed, clinical impact of an analytical change is minimal in patients' management. However, cautious and personalized follow-up period after the change is still mandatory, especially in patients with Tg levels between 0.2 and 1 ng/mL.


Assuntos
Neoplasias da Glândula Tireoide , Humanos , Seguimentos , Estudos Prospectivos , Neoplasias da Glândula Tireoide/diagnóstico , Autoanticorpos
3.
Clin Chim Acta ; 543: 117303, 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36948237

RESUMO

AIMS: Characterization of PSA in extracellular microvesicles (EVs) and its reactivity to commercial methods. MATERIALS AND METHODS: EVs derived from serum of 47 prostate cancer (PCa) patients, 27 benign prostatic hyperplasia (BPH) patients and 42 healthy controls were analyzed. EVs isolation and quantification of PSA immunoreactive to total (ev-T-PSA) or free (ev-F-PSA) PSA immunoassays, were performed using commercial assays. PSA in CD81+ or CD63+ EVs was determined directly in serum by an immunocapture-ELISA (IC-ELISA). RESULTS: Ev-T-PSA immunoreactive to Elecsys assay was detected in all samples. Median T-PSA ev/srm ratio was 2.20 % (Q1-Q3: 0.80-4.00 %), although in some samples this ratio reached 59 %. T-PSA ev/srm ratio was higher in those samples with serum T-PSA below 4 µg/L than in those exceeding that cut-off (p < 0.001). T-PSA ev/srm ratio was lower in PCa patients compared to healthy controls and BPH patients (p < 0.001). Elecsys immunoassays detected higher concentrations of ev-T-PSA and ev-F-PSA than Immulite (p < 0.001). PSA was detected by IC-ELISA more intensely in CD81+ EVs than in CD63+ EVs, and ev-T-PSA correlated with PSA+ CD63+ (p < 0.001) but not with PSA+ CD81+. CONCLUSION: EVs-bound PSA is another form of circulating PSA whose measurement could be easily performed in clinical laboratories by automated immunoassays.


Assuntos
Micropartículas Derivadas de Células , Hiperplasia Prostática , Neoplasias da Próstata , Masculino , Humanos , Hiperplasia Prostática/diagnóstico , Antígeno Prostático Específico , Neoplasias da Próstata/diagnóstico , Imunoensaio
5.
J Cancer Res Ther ; 18(4): 1183-1185, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36149184

RESUMO

The incidence of autoimmune thyroid disorders is higher among women with breast cancer (BC) than in other solid malignancies, while it has not a prognostic impact. Trastuzumab (T) is a humanized monoclonal antibody approved for human epidermal growth factor receptor 2 (HER2)-positive BC in the neoadjuvant, adjuvant, and metastatic scenarios. Since 2014, subcutaneous (SC) T has been employed with the same efficacy as the intravenous formulation together with an easier way of administration. To date, autoimmune thyroiditis has been linked rarely to the use of intravenous T, and no cases have been related to the SC presentation. We report two cases of HER2-positive early BC patients who developed hypothyroidism during maintenance therapy with SC T that required levothyroxine supplementation. SC T includes recombinant human hyaluronidase to facilitate tissue penetration of the drug. This enzyme may alter the thyroid gland stroma and facilitate the development of thyroid disorders. Thyroid function tests are recommended in patients on SC T.


Assuntos
Antineoplásicos Imunológicos , Neoplasias da Mama , Glândula Tireoide , Trastuzumab , Antineoplásicos Imunológicos/efeitos adversos , Antineoplásicos Imunológicos/uso terapêutico , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Feminino , Humanos , Hialuronoglucosaminidase/uso terapêutico , Injeções Subcutâneas , Receptor ErbB-2/metabolismo , Glândula Tireoide/patologia , Tiroxina/uso terapêutico , Trastuzumab/efeitos adversos , Trastuzumab/uso terapêutico
6.
Sci Rep ; 12(1): 9752, 2022 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-35697832

RESUMO

Breath tests used to evaluate carbohydrates malabsorption require baseline H2 and CH4 levels as low as possible. Test cancellation is recommended when exceeding certain cut-offs (H2 ≥ 20 ppm and CH4 ≥ 10 ppm). Although following preparation protocols, many patients have baseline levels above those cut-offs. We investigated if light walking can reduce baseline H2 and CH4 levels. We retrospectively analyzed baseline H2 and CH4 levels from 1552 breath tests. Baseline levels (B1), especially in H2, were lower when obtained at later hours of the day. In those with baseline levels above cut-off, re-sampling (B2) after light walking for one hour, decreased H2 levels 8 ppm (Q1-Q3: 1-18 ppm), and 2 ppm (Q1-Q3: 0-3 ppm) for CH4. Consequently, 40% of tests with elevated B1 levels, presented B2 levels below mentioned cut-offs. Ten percent of tests considered negative when using B1 for calculations, turned positive when using B2 instead. All positive tests when using B1 values, remained elevated when using B2. Re-sampling after light walking for one hour could allow test performance in those with previous elevated baseline levels, avoiding diagnosis delays. Using the second sample for delta calculations identifies positive patients for malabsorption that would have been considered negative.


Assuntos
Hidrogênio , Síndromes de Malabsorção , Testes Respiratórios/métodos , Carboidratos , Humanos , Estudos Retrospectivos
7.
Clin Chem Lab Med ; 60(7): 1003-1010, 2022 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-35470640

RESUMO

OBJECTIVES: Retrospective studies frequently assume analytes long-term stability at ultra-low temperatures. However, these storage conditions, common among biobanks and research, may increase the preanalytical variability, adding a potential uncertainty to the measurements. This study is aimed to evaluate long-term storage stability of different analytes at <-70 °C and to assess its impact on the reference change value formula. METHODS: Twenty-one analytes commonly measured in clinical laboratories were quantified in 60 serum samples. Samples were immediately aliquoted and frozen at <-70 °C, and reanalyzed after 11 ± 3.9 years of storage. A change in concentration after storage was considered relevant if the percent deviation from the baseline measurement was significant and higher than the analytical performance specifications. RESULTS: Preanalytical variability (CVP) due to storage, determined by the percentage deviation, showed a noticeable dispersion. Changes were relevant for alanine aminotransferase, creatinine, glucose, magnesium, potassium, sodium, total bilirubin and urate. No significant differences were found in aspartate aminotransferase, calcium, carcinoembryonic antigen, cholesterol, C-reactive protein, direct bilirubin, free thryroxine, gamma-glutamyltransferase, lactate dehydrogenase, prostate-specific antigen, triglycerides, thyrotropin, and urea. As nonnegligible, CVP must remain included in reference change value formula, which was modified to consider whether one or two samples were frozen. CONCLUSIONS: After long-term storage at ultra-low temperatures, there was a significant variation in some analytes that should be considered. We propose that reference change value formula should include the CVP when analyzing samples stored in these conditions.


Assuntos
Bilirrubina , Coleta de Amostras Sanguíneas , Humanos , Masculino , Estudos Retrospectivos , Temperatura , Fatores de Tempo
8.
Front Cell Dev Biol ; 10: 1055288, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36726591

RESUMO

Metastatic melanoma presents, in many cases, oncogenic mutations in BRAF, a MAPK involved in proliferation of tumour cells. BRAF inhibitors, used as therapy in patients with these mutations, often lead to tumour resistance and, thus, the use of MEK inhibitors was introduced in clinics. BRAFi/MEKi, a combination that has modestly increased overall survival in patients, has been proven to differentially affect immune ligands, such as NKG2D-ligands, in drug-sensitive vs. drug-resistant cells. However, the fact that NKG2D-ligands can be released as soluble molecules or in extracellular vesicles represents an additional level of complexity that has not been explored. Here we demonstrate that inhibition of MAPK using MEKi, and the combination of BRAFi with MEKi in vitro, modulates NKG2D-ligands in BRAF-mutant and WT melanoma cells, together with other NK activating ligands. These observations reinforce a role of the immune system in the generation of resistance to directed therapies and support the potential benefit of MAPK inhibition in combination with immunotherapies. Both soluble and EV-associated NKG2D-ligands, generally decreased in BRAF-mutant melanoma cell supernatants after MAPKi in vitro, replicating cell surface expression. Because potential NKG2D-ligand fluctuation during MAPKi treatment could have different consequences for the immune response, a pilot study to measure NKG2D-ligand variation in plasma or serum from metastatic melanoma patients, at different time points during MAPKi treatment, was performed. Not all NKG2D-ligands were equally detected. Further, EV detection did not parallel soluble protein. Altogether, our data confirm the heterogeneity between melanoma lesions, and suggest testing several NKG2D-ligands and other melanoma antigens in serum, both as soluble or vesicle-released proteins, to help classifying immune competence of patients.

9.
Cancers (Basel) ; 13(17)2021 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-34503141

RESUMO

Lung cancer is a leading cause of cancer-related death worldwide and in most cases, diagnosis is reached when the tumor has already spread and prognosis is quite poor. For that reason, the research for new biomarkers that could improve early diagnosis and its management is essential. Exosomes are microvesicles actively secreted by cells, especially by tumor cells, hauling molecules that mimic molecules of the producing cells. There are multiple methods for exosome isolation and analysis, although not standardized, and cancer exosomes from biological fluids are especially difficult to study. Exosomes' cargo proteins, RNA, and DNA participate in the communication between cells, favoring lung cancer development by delivering signals for growth, metastasis, epithelial mesenchymal transition, angiogenesis, immunosuppression and even drug resistance. Exosome analysis can be useful as a type of liquid biopsy in the diagnosis, prognosis and follow-up of lung cancer. In this review, we will discuss recent advances in the role of exosomes in lung cancer and their utility as liquid biopsy, with special attention to isolating methods.

10.
Mol Ther Nucleic Acids ; 25: 207-219, 2021 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-34458006

RESUMO

Variegate porphyria (VP) results from haploinsufficiency of protoporphyrinogen oxidase (PPOX), the seventh enzyme in the heme synthesis pathway. There is no VP model that recapitulates the clinical manifestations of acute attacks. Combined administrations of 2-allyl-2-isopropylacetamide and rifampicin in rabbits halved hepatic PPOX activity, resulting in increased accumulation of a potentially neurotoxic heme precursor, lipid peroxidation, inflammation, and hepatocyte cytoplasmic stress. Rabbits also showed hypertension, motor impairment, reduced activity of critical mitochondrial hemoprotein functions, and altered glucose homeostasis. Hemin treatment only resulted in a slight drop in heme precursor accumulation but further increased hepatic heme catabolism, inflammation, and cytoplasmic stress. Hemin replenishment did protect against hypertension, but it failed to restore action potentials in the sciatic nerve or glucose homeostasis. Systemic porphobilinogen deaminase (PBGD) mRNA administration increased hepatic PBGD activity, the third enzyme of the pathway, and rapidly normalized serum and urine porphyrin precursor levels. All features studied were improved, including those related to critical hemoprotein functions. In conclusion, the VP model recapitulates the biochemical characteristics and some clinical manifestations associated with severe acute attacks in humans. Systemic PBGD mRNA provided successful protection against the acute attack, indicating that PBGD, and not PPOX, was the critical enzyme for hepatic heme synthesis in VP rabbits.

11.
Cytokine ; 141: 155471, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33607398

RESUMO

BACKGROUND: Myeloid-derived suppressor cells (MDSCs) are relevant in prostate cancer microenvironment collaborating in tumor development. The main tumor marker used in this disease, prostate-specific antigen (PSA), does not provide information related to this tumor microenvironment. Cancer cells secrete exosomes carrying bioactive molecules contributing to MDSCs recruitment and induction. The aim of this study was to characterize the perioperative changes of exosomal cytokines relevant in MDSCs recruitment induced by prostatectomy in prostate cancer patients. METHODS: Blood was drawn from 26 early-stage prostate cancer patients before and after radical prostatectomy and from 16 healthy volunteers. Serum exosomes were separated by precipitation. Cytokines related with MDSC cell recruitment and activation CCL2, CXCL2, CXCL5, CXCL8, CXCL12, MIF, S100A9 and TGF-ß were measured in serum and serum-derived exosomes using immunometric assays. RESULTS: All cytokines were detected both in serum and exosomes, except for CXCL12, which was detected only in serum. Exosomes were enriched specially in MIF, TGF-ß and CXCL2. Presurgical MIF levels in exosomes correlated negatively with serum PSA. Also, presurgical TGF-ß decreased both in serum and exosomes as Gleason score rises. Patients presurgical exosomes had increased CCL2, CXCL5 and TGF-ß levels than exosomes from healthy controls. These differences were not observed when cytokines were analyzed in serum, except for TGF-ß. Cytokine levels of CCL2, CXCL5 decreased in patients' postsurgical exosomes, while TGF-ß further increased. On the contrary, S100A9 levels were lower in patients presurgical exosomes but increased after radical prostatectomy. CONCLUSIONS: Blood exosomal content in cytokines constitute an attractive source to evaluate MDSCs immunomodulators providing additional information related to tumor microenvironment in prostate cancer.


Assuntos
Quimiocinas/imunologia , Exossomos/imunologia , Células Supressoras Mieloides/imunologia , Proteínas de Neoplasias/imunologia , Prostatectomia , Neoplasias da Próstata , Microambiente Tumoral/imunologia , Adulto , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Período Perioperatório , Neoplasias da Próstata/imunologia , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia
12.
Clin Chem Lab Med ; 58(8): 1341-1348, 2020 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-32623849

RESUMO

Background Genomic alterations studies in cell-free DNA (cfDNA) have increasing clinical use in oncology. Next-generation sequencing (NGS) technology provides the most complete mutational analysis, but nowadays limited data are available related to the comparison of results reported by different platforms. Here we compare two NGS panels for cfDNA: Oncomine™ Pan-Cancer Cell-Free Assay (Thermo Fisher Scientific), suitable for clinical laboratories, and Guardant360® (GuardantHealth), with more genes targeted but only available in an outsourcing laboratory. Methods Peripheral blood was obtained from 16 advanced cancer patients in which Guardant360® (G360) was requested as part of their clinical assistance. Blood samples were sent to be analyzed with G360 panel, and an additional blood sample was drawn to obtain and analyze cfDNA with Oncomine™ Pan-Cancer (OM) panel in an Ion GeneStudio S5™ System. Results cfDNA analysis globally rendered 101 mutations. Regarding the 55/101 mutations claimed to be included by manufacturers in both panels, 17 mutations were reported only by G360, 10 only by OM and 28 by both. In those coincident cases, there was a high correlation between the variant allele fractions (VAFs) calculated with each panel (r = 0.979, p < 0.01). Regarding the six actionable mutations with an FDA-approved therapy reported by G360, one was missed with OM. Also, 12 mutations with clinical trials available were reported by G360 but not by OM. Conclusions In summary, G360 and OM can produce different mutational profile in the same sample, even in genes included in both panels, which is especially important if these mutations are potentially druggable.


Assuntos
Ácidos Nucleicos Livres/genética , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Mutação , Neoplasias/genética , Humanos
13.
Adv Lab Med ; 1(4): 20200102, 2020 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37360621

RESUMO

Objectives: Lactose malabsorption is generally assessed by hydrogen breath testing (HBT). However, this test is not recommended in patients with high baseline hydrogen concentrations (H2B). In addition, breath testing is not recommended in the current situation created by the COVID-19 pandemic, due to the potential infectiveness of the samples. The objective is to assess concordance between HBT and lactose tolerance test (LTT) depending on H2B concentrations. Methods: A total of 430 patients (40 years, Q1-Q3 = 28-54 years; 66.7% women) suspected of lactose malabsorption were included in the study. Breath and heparinized blood samples were collected at baseline and sequentially after the intake of 50 g of lactose, to measure hydrogen in breath and glycemia in blood, respectively. Results: H2B was <10 ppm in 69.5% of subjects; 10-20 ppm in 14.7%; and >20 ppm in 15.8% of subjects. In patients with H2B <20 ppm, concordance between HBT and LTT was moderate and consistently improved when the cut-off in LTT was set at 15 mg/dL. The increase in hydrogen and glucose correlated negatively (r=-0.389; p<0.05). The increase in glycemia during LTT was not influenced by H2B levels obtained in HBT. Conclusions: LTT emerges as an alternative to HBT to assess lactose malabsorption in the presence of high H2B levels or when breath testing is not recommended by the circumstances. The best concordance was obtained when the cut-off for LTT was set at 15 mg/dL.

14.
Adv Lab Med ; 1(1): 20190017, 2020 Mar.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37362557

RESUMO

Background: Thyroglobulin (Tg) is fundamental for differentiated thyroid cancer (DTC) monitoring. Tg detection can be enhanced using recombinant human thyroid-stimulating hormone (TSH) (rhTSH). This study is aimed to evaluate the use of the rhTSH stimulation test when using a high-sensitivity Tg assay. Methods: We retrospectively studied 181 rhTSH tests from 114 patients with DTC and negative for antithyroglobulin antibodies (anti-TgAb). Image studies were performed in all cases. Serum Tg and anti-TgAb were measured using specific immunoassays. Results: rhTSH stimulation in patients with basal serum Tg (b-Tg) concentrations lower than 0.2 ng/mL always resulted in rhTSH-stimulated serum Tg (s-Tg) concentrations lower than 1.0 ng/mL and negative structural disease. In patients with b-Tg concentration between 0.2 and 1.0 ng/mL, s-Tg detected one patient (1/30) who showed biochemical incomplete response. Patients with negative images had lower s-Tg than those with nonspecific or abnormal findings (p<0.05). Receiver operating characteristic curve analysis of the s-Tg to detect altered images showed an area under the curve of 0.763 (p<0.05). With an s-Tg cutoff of 0.85 ng/mL, the sensitivity was 100%, decreasing to 96.15% with an s-Tg cutoff of 2 ng/mL. Conclusions: Patients with DTC with b-Tg concentrations equal or higher than 0.2 ng/mL can benefit from the rhTSH stimulation test.

16.
Clin Chem Lab Med ; 57(10): 1539-1545, 2019 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-30990781

RESUMO

Background Exosomes are nanovesicles released by cells that can be detected in blood. Exosomes contain several molecules, such as cytokines that have potential utility as disease biomarkers. The aim of the present work is to compare six different commercial kits suitable for the clinical laboratory in relation to the efficiency and purity of exosome isolation, and their effect in subsequent cytokines analysis. Methods Serum exosomes were obtained from 10 volunteers using six commercial kits: exoEasy, ExoQuick, Exo-spin, ME kit, ExoQuick Plus and Exo-Flow. Exosome concentrations and size distributions were quantified by nanoparticle tracking analysis. Exosome markers CD63, CD9 and TSG101 were determined by Western blot. ApoB and albumin were measured using nephelometry. S100A9, CXCL5 and CXCL12 were measured using a Luminex assay. Results The concentration of particles obtained between different kits varied by a factor of 100. There was no correlation in particle concentrations extracted between different kits, except between ExoQuick and Exo-Flow. The highest exosome purity was achieved with ExoQuick Plus and exoEasy, while the lowest were achieved with ME and ExoQuick. Albumin was present in all exosome extracts analyzed and ApoB in all except those extracted with Exo-Flow and ME. Cytokine detection varied depending on the purification kit used and there was no correlation in cytokine concentrations between samples obtained with different kits. Conclusions Both the sample and the type of commercial kit used affect the efficiency and purity of exosome isolation. In addition, the exosome purification method deeply affects the capability to detect and quantify cytokines.


Assuntos
Técnicas de Laboratório Clínico/métodos , Citocinas/análise , Exossomos/metabolismo , Biomarcadores , Serviços de Laboratório Clínico/normas , Citocinas/sangue , Exossomos/genética , Humanos , Kit de Reagentes para Diagnóstico/normas
17.
Dis Markers ; 2019: 7954921, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30809319

RESUMO

Epidermal growth factor receptor (EGFR) mutational testing in advanced non-small-cell lung cancer (NSCLC) is usually performed in tumor tissue, although cfDNA (cell-free DNA) could be an alternative. We evaluated EGFR mutations in cfDNA as a complementary tool in patients, who had already known EGFR mutations in tumor tissue and were treated with either EGFR-tyrosine kinase inhibitors (TKIs) or chemotherapy. We obtained plasma samples from 21 advanced NSCLC patients with known EGFR tumor mutations, before and during therapy with EGFR-TKIs and/or chemotherapy. cfDNA was isolated and EGFR mutations were analyzed with the multiple targeted cobas EGFR Mutation Test v2. EGFR mutations were detected at baseline in cfDNA from 57% of patients. The semiquantitative index (SQI) significantly decreased from the baseline (median = 11, IQR = 9.5-13) to the best response (median = 0, IQR = 0-0, p < 0.01), followed by a significant increase at progression (median = 11, IQR = 11-15, p < 0.01) in patients treated with either EGFR-TKIs or chemotherapy. The SQI obtained with the cobas EGFR Mutation Test v2 did not correlate with the concentration in copies/mL determined by droplet digital PCR. Resistance mutation p.T790M was observed at progression in patients with either type of treatment. In conclusion, cfDNA multiple targeted EGFR mutation analysis is useful for treatment monitoring in tissue of EGFR-positive NSCLC patients independently of the drug received.


Assuntos
Biomarcadores Tumorais/genética , Carcinoma Pulmonar de Células não Pequenas/genética , Ácidos Nucleicos Livres/genética , Neoplasias Pulmonares/genética , Mutação , Idoso , Antineoplásicos/uso terapêutico , Biomarcadores Tumorais/sangue , Carcinoma Pulmonar de Células não Pequenas/sangue , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Ácidos Nucleicos Livres/sangue , Receptores ErbB/antagonistas & inibidores , Receptores ErbB/genética , Feminino , Humanos , Neoplasias Pulmonares/sangue , Neoplasias Pulmonares/tratamento farmacológico , Masculino , Pessoa de Meia-Idade , Inibidores de Proteínas Quinases/uso terapêutico
18.
Adv Clin Chem ; 83: 73-119, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29304904

RESUMO

Liquid biopsy refers to the molecular analysis in biological fluids of nucleic acids, subcellular structures, especially exosomes, and, in the context of cancer, circulating tumor cells. In the last 10 years, there has been an intensive research in liquid biopsy to achieve a less invasive and more precise personalized medicine. Molecular assessment of these circulating biomarkers can complement or even surrogate tissue biopsy. Because of this research, liquid biopsy has been introduced in clinical practice, especially in oncology, prenatal screening, and transplantation. Here we review the biology, methodological approaches, and clinical applications of the main biomarkers involved in liquid biopsy.


Assuntos
Pesquisa Biomédica , DNA de Neoplasias/análise , Biópsia Líquida/métodos , Neoplasias/diagnóstico , Células Neoplásicas Circulantes/patologia , Medicina de Precisão , RNA Neoplásico/análise , Humanos
19.
Clin Chim Acta ; 454: 28-32, 2016 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-26724367

RESUMO

BACKGROUND: Malignant melanoma is an aggressive cancer with an increasing incidence. Exosomes are actively secreted microvesicles, whose characteristics reflect those of the cell they are originated in. The aim of this study was to identify and evaluate the presence of the melanoma biomarkers MIA, S100B and tyrosinase-related protein 2 (TYRP2) in exosomes and their potential clinical utility. METHODS: Serum samples were obtained from stage IV melanoma patients, melanoma-free patients and healthy controls. Exosomes were precipitated and TYRP2, MIA and S100B concentrations were quantified in serum, exosomes, and exosome-free serum. RESULTS: Both MIA and S100B were detected in exosomes and correlated significantly with serum concentrations (S100B: r=0.968; MIA: r=0.799; p<0.001). MIA and S100B concentrations in exosomes were significantly higher in melanoma patients than in healthy controls and disease-free patients. However, TYRP2 concentrations in exosomes did not differ between these three groups. ROC curves analysis rendered AUCs for MIA of 0.883 (p<0.01) and of 0.840 for S100B (p<0.01). Patients with exosome MIA concentration higher than 2.5 µg/L showed shorter median survival related to those with lower level (4 versus 11 months; p<0.05). CONCLUSIONS: MIA and S100B can be detected in exosomes from melanoma patients and their quantification presents diagnostic and prognostic utility.


Assuntos
Biomarcadores Tumorais/sangue , Exossomos/química , Proteínas da Matriz Extracelular/sangue , Oxirredutases Intramoleculares/sangue , Melanoma/sangue , Melanoma/diagnóstico , Proteínas de Neoplasias/sangue , Subunidade beta da Proteína Ligante de Cálcio S100/sangue , Adulto , Linhagem Celular Tumoral , Humanos , Masculino , Melanoma/patologia , Pessoa de Meia-Idade , Estadiamento de Neoplasias
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...